Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

Schneider Electric BMXAMI0810H - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

medidor de eletricidade/elétrica/

Schneider Electric BMXAMI0810H

(Modicon X80 Platform Hardened 8-channel Isolated High-speed Analog Input Module), including model breakdown, core parameters, interface/configuration, and application scenarios Model and Positioning Model: BMXAMI0810H; belongs to Modicon X80 I/O platform, compatible with Modicon M580, M340 PAC/PLC Suffix H = Hardened type. Compared with the standard BMXAMI0810, it features wider temperature range, higher vibration resistance and ...

  • Detalhes do produto

(Modicon X80 Platform Hardened 8-channel Isolated High-speed Analog Input Module), including model breakdown, core parameters, interface/configuration, e cenários de aplicação

  1. Model and Positioning

Modelo: BMXAMI0810H; belongs to Modicon X80 I/O platform, compatible with Modicon M580, M340 PAC/PLC

Suffix H = Hardened type. Compared with the standard BMXAMI0810, it features wider temperature range, higher vibration resistance and stronger EMI immunity, adequado para ambientes industriais agressivos.

Função: 8-channel fully isolated voltage/current analog input, high-speed conversion, flexible signal type and range configuration via software + DIP switches.

  1. Core Technical Specifications
Categoria de parâmetroDetailed Specifications
Input Channels8 canais, per-channel independent isolation
Signal TypesTensão (±10V, 0–10V, ±5V, 0–5V); Atual (4–20mA, 0–20mA)
Resolução15 bits + bit de sinal (equivalent to 16-bit accuracy)
Velocidade de conversãoHigh-speed mode, short single-channel conversion time, supports synchronous batch acquisition
Accuracy±0.1% of full scale (typical), low drift design
Fonte de energia24V DC, power consumption 1.54W
Temperatura operacionalTipo endurecido: -25°C a +70°C (standard version: 0°C~60°C)
Grau de ProteçãoIP20 (must be installed in control cabinet)
MontagemMontagem em trilho DIN (standard 35mm)
CertificaçõesCE, UL, CSA, ATEX, IECEx (suitable for hazardous areas)
Wiring AccessoriesBMXFTB2800 (screw terminal), BMXFTB2820 (spring terminal), BMXFTW308S/508S flying leads, BMXFTA150/300 (with ABE7 base)
  1. Key Features and Advantages
  2. Full-channel electrical isolation: Effectively suppresses common-mode interference and surges in industrial sites, ensuring stable data acquisition.
  3. Hardened wide-temperature design: Adapts to extreme temperature and vibration environments such as metallurgy, mining, and outdoor cabinets.
  4. High-speed conversion + flexible filtering: Filter parameters can be adjusted via software, balancing dynamic response and data smoothing.
  5. Seamless integration with M580/M340: Unified backplane bus of X80 platform, supports hot-swappable maintenance (system configuration required).
  6. Multiple wiring schemes: Optional terminal blocks / flying leads / base cables to adapt to different cabinet wiring habits.
  7. Cenários típicos de aplicação
  8. Process control: Chemical, petroleum, water treatment; acquisition of pressure, flow, nível, pH value (4–20mA/0–10V transmitter signals).
  9. Metallurgy / Paper making: High-temperature workshops, production line monitoring; wide-temperature tolerance, strong anti-EMI capability.
  10. Energy industry: Wind power, photovoltaic, substations; acquisition of voltage, atual, poder; stable operation in outdoor / box-type substations.
  11. Heavy machinery / Marine: High-vibration, large temperature-fluctuation scenarios such as offshore platforms and port machinery.
  12. Smart manufacturing lines: Equipment status monitoring, sensor data acquisition; works with M580 redundant systems to improve reliability.
  13. Model Differentiation and Alternatives
  14. BMXAMI0810 vs BMXAMI0810H: The former is standard version (0°C~60°C); the latter H-type hardened wide-temperature (-25°C~70°C), with stronger shock and vibration resistance.
  15. Equivalent alternative models:

Siemens: 6ES7531-7KF00-0AB0 (ET 200SP AI module)

ABB: AI890 8-channel isolated analog input

Rockwell: 1756-IF8H (ControlLogix high-temperature analog module)

  1. Selection and Notes
  2. Confirm on-site temperature range: If below 0°C or above 60°C, H-type must be selected.
  3. Confirm wiring method: Terminal blocks suit fixed cabinets; flying leads suit narrow spaces or frequent replacement.
  4. System redundancy requirements: In M580 redundant systems, modules must be configured in pairs with redundant communication enabled.
  5. Grounding and shielding: Full shielding of analog signal cables, single-point grounding to avoid interference.

Schneider Electric BMX Series (Modicon X80)

Lista completa de modelos & Alternative Product Manual

  1. BMX Series Overview and Coding Rules

Schneider BMX Series are core I/O modules of the Modicon X80 platform, compatible with M580, M340 PAC/PLC. They cover digital, analog, comunicação, power supply, motion control and other categories. Suffix H means hardened type (wide temperature -25°C~+70°C, higher vibration & EMI resistance).

Model Coding Rule (BMXABCDEFG)

SegmentSignificadoExemplo
BMXFixed prefix (Modicon X80 series)BMX
UMModule typeD=Digital, A=Analog, N=Communication, C=Power, M=Motion
BSubtypeDI=Digital Input, DO=Digital Output, AI=Analog Input, AO=Analog Output, NO=Ethernet
CDEFChannel count / specification0810=8-channel/standard, 0410=4-channel/high-speed
G/HVersionH=Hardened, Default=Standard (0°C~60°C)
  1. Complete BMX Series Model List (By Type)

2.1 Digital Input Modules (BMXDDI/BMXDAI)

ModeloEspecificaçãoApplicationHardened Version
BMXDDI160216-ch 24V DC, sink, non-isolatedGeneral industrial signal acquisitionBMXDDI1602H
BMXDDI3202K32-ch 24V DC, source, isolatedHigh-density I/O, centralized cabinet acquisitionBMXDDI3202KH
BMXDDI6402K64-ch 24V DC, source, dual 40-pinLarge production lines, robot workstationsBMXDDI6402KH
BMXDAI08148-ch 100-120V AC, isolatedMotor control loops, high-voltage equipment monitoringBMXDAI0814H
BMXDAI160416-ch 100-120V AC, isolatedFactory power systems, HVAC controlBMXDAI1604H

2.2 Digital Output Modules (BMXDDO/BMXDAO)

ModeloEspecificaçãoApplicationHardened Version
BMXDDO160216-ch 24V DC, 0.5UM, non-isolatedSolenoid valves, indicator controlBMXDDO1602H
BMXDDO3202K32-ch 24V DC, 0.5UM, isolatedDistributed control for large equipmentBMXDDO3202KH
BMXDDO6402KC64-ch 24V DC, 0.5UM, dual 40-pinAutomotive production lines, logistics sortingBMXDDO6402KCH
BMXDAO160516-ch 100-240V AC, triacHeating systems, lighting controlBMXDAO1605H
BMXDDO161016-ch 24V DC, 2UM, high-powerSmall motors, valve actuatorsBMXDDO1610H

2.3 Analog Input Modules (BMXAMI/BMXART)

ModeloEspecificaçãoAccuracyHardened Version
BMXAMI04104-ch voltage/current, isolated, high-speed15 bits + bit de sinalBMXAMI0410H
BMXAMI08108-ch voltage/current, isolated, high-speed15 bits + bit de sinalBMXAMI0810H (Popular)
BMXART04144-ch RTD/TC, isolated16-bit, dedicated for temperatureBMXART0414H
BMXART08148-ch RTD/TC, isolated16-bit, temperature patrolBMXART0814H

2.4 Analog Output Modules (BMXAMO)

ModeloEspecificaçãoAccuracyHardened Version
BMXAMO04104-ch voltage/current, isolated, high-speed15 bits + bit de sinalBMXAMO0410H
BMXAMO08028-ch voltage/current, isolated, padrão14 bits + bit de sinalBMXAMO0802H

2.5 Mixed I/O Modules (BMXAMM)

ModeloEspecificaçãoApplication
BMXAMM06004IA + 2AO, mixed analog, isolatedSmall process control, equipment integrated control
BMXAMM10008IA + 2AO, mixed analog, isolatedMedium process monitoring, building automation

2.6 Communication Modules (BMXNOE/BMXNOM/BMXCRA)

ModeloFunçãoInterfaceCompatibilidade
BMXNOE0100Ethernet interface, TCP/IP1×RJ45M340/M580 local
BMXNOM0200Modbus RTU/ASCII Master2×RS485Instrument networking, inverter control
BMXCRA31210PROFIBUS-DP Master1×DP portSiemens interconnection, process control
BMXETH0100Dual Ethernet, redundância2×RJ45M580 redundant systems, critical control

2.7 Power Supply Modules (BMXCPS)

ModeloInput / OutputPowerCaracterísticas
BMXCPS2000100-240V AC/DC → 24V DC20CCompact, for M340
BMXCPS3500100-240V AC/DC → 24V DC35CStandard type, for M580
BMXCPS402285-264V AC → 24V DC40CWide input voltage, industrial grid compatible

2.8 Motion Control Modules (BMXMSP)

ModeloFunçãoAxesCompatibilidade
BMXMSP02002-axis PTO + 4DI/2DO auxiliary, 24V DC2 axesStepper/servo control, positioning systems
BMXMSP04004-axis PTO + 8DI/4DO auxiliary, 24V DC4 axesMulti-axis linkage, robot control
  1. BMX Series vs. Other Brands Alternative Models (with Order Numbers)
Schneider ModelSiemens AlternativeOrder NumberKey Matching Points
BMXDDI3202KH6ES7131-6BH01-0BA06ES7131-6BH01-0BA032DI/24V DC, isolated, source
BMXAMI0810H6ES7531-7KF00-0AB06ES7531-7KF00-0AB08AI/isolated/high-speed, 16bit
BMXAMO0410H6ES7532-5HF00-0AB06ES7532-5HF00-0AB04AO/isolated/high-speed, 16bit
BMXCRA312106ES7138-4HA00-0AB06ES7138-4HA00-0AB0PROFIBUS-DP Master, M580 compatible

3.2 ABB Alternatives (AC500/S700 Series)

Schneider ModelABB AlternativeOrder NumberKey Matching Points
BMXDDI1602HAI8103BSE018100R116DI/24V DC, isolated, hardened
BMXAMI0810HAI8903BSE018190R18AI/isolated/wide-temp, 16bit
BMXAMO0410HAO8903BSE018200R14AO/isolated/wide-temp, 16bit
BMXNOE0100CM5793BSE018151R1Ethernet interface, TCP/IP, AC500 compatible

3.3 Rockwell Alternatives (ControlLogix)

Schneider ModelRockwell AlternativeOrder NumberKey Matching Points
BMXDDI3202KH1756-IB321756-IB3232DI/24V DC, source, isolated
BMXAMI0810H1756-IF8H1756-IF8H8AI/isolated/high-temp, 16bit
BMXAMO0410H1756-OF41756-OF44AO/isolated/high-speed, 16bit
BMXCRA312101756-DP11756-DP1PROFIBUS-DP Master, ControlLogix compatible
  1. Key Points for Selection and Replacement

4.1 Core Matching Dimensions (Must Check for Replacement)

DimensionMatching StandardNotas
Channel count / tipoExactly the same (por exemplo, 8AI→8AI, 32DI→32DI)Avoid insufficient or redundant channels
Electrical isolationSame level (per-channel / group isolation)Isolated type is mandatory for industrial sites
Faixa de temperaturaHardened → Hardened (-25°C~+70°C)No downgrading for outdoor / metalurgia / mining
Communication protocolCompatible with original system (por exemplo, PROFINET/Modbus)Bus compatibility test required for non-Schneider modules
Método de montagemSame rail / backplane adaptationSpecial adaptation required for M580 redundant systems

4.2 Replacement Implementation Recommendations

  1. Schneider→Schneider: Prioritize same-series upgrades (por exemplo, BMXAMI0810→BMXAMI0810H). No program modification needed; only firmware version check required.
  2. Cross-brand replacement:

Perform signal compatibility test before replacement (voltage/current range, response time).

In M580 redundant systems, alternative modules must support hot-swap and redundant communication.

Analog modules require accuracy deviation calibration (±0.1% F.S. as industrial standard).

  1. Otimização de custos: Domestic alternatives such as Advantech, NORCO are available, with similar performance and 30%-50% lower price.
  2. Quick Selection Table (Popular Models)
ApplicationPreferred Schneider ModelSiemens AlternativeABB AlternativeRockwell Alternative
Process control (4-20mA acquisition)BMXAMI0810H6ES7531-7KF00-0AB0AI8901756-IF8H
Factory automation (24V DC I/O)BMXDDI3202KH/BMXDDO3202KH6ES7131-6BH01-0BA0 / 6ES7132-6BH01-0BA0AI810/AO8101756-IB32/1756-OB32
Temperature monitoring (TC/RTD)BMXART0814H6ES7531-7PF00-0AB0AI8951756-IT6
Instrument networking (Modbus RTU)BMXNOM02006ES7138-4CA01-0AA0CM5781756-MODULE

Anterior: