Schneider Electric EA9RN2C1030C - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

Schneider Electric EA9RN2C1030C - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

disjuntor/

Schneider Electric EA9RN2C1030C

2-Pole Type A Residual Current Operated Circuit Breaker (RCBO) from the Easy9 series, factory-assembled integrated design, fornecendo proteção tripla contra sobrecarga, short-circuit and earth leakage Key Parameters: Rated current 10A, C-curve tripping characteristic (5–10×In), rated residual operating current 30mA, capacidade de interrupção 6kA, rated voltage 230/400V AC Applications: Low-voltage final distribution in residential and commercial buildings; ...

  • Detalhes do produto

2-Pole Type A Disjuntor Operado por Corrente Residual (RCBO) from the Easy9 series, factory-assembled integrated design, fornecendo proteção tripla contra sobrecarga, short-circuit and earth leakage

Parâmetros principais: Rated current 10A, C-curve tripping characteristic (5–10×In), rated residual operating current 30mA, capacidade de interrupção 6kA, rated voltage 230/400V AC

Aplicativos: Low-voltage final distribution in residential and commercial buildings; especially suitable for loads sensitive to pulsating DC earth leakage (por exemplo, electronic equipment, lighting systems)

Certificações & Ambiente: Complies with GB 16917 / CEI 601009, CCC certified, Green Premium product, meets RoHS / REACH requirements

  1. Model Number Breakdown
SegmentDescrição
EA9RNEasy9 series, electronic RCBO (factory‑preassembled)
22‑Pole (2P) proteção
CC‑curve tripping characteristic (for general lighting and distribution)
10Rated current 10A
30Rated residual operating current 30mA
CType A earth leakage protection (detects AC + pulsating DC leakage)
  1. Complete Technical Data
CategoriaEspecificações
Elétrica• Rated voltage: 230/400V e
• Rated frequency: 50/60Hz
• Rated current (Em): 10UM
• Tripping characteristic: C‑curve (5–10×In)
• Rated residual operating current (IΔn): 30mA
• Residual current type: Type A
• Breaking capacity (Icn): 6o
• Rated short‑time withstand current (Icw): 1kA/1s
Mecânico & Environmental• Mechanical endurance: 20,000 operações
• Electrical endurance: 4,000 operações
• Mounting: 35mm trilho DIN
• Operating temperature: ‑25°C to +60°C
• Storage temperature: ‑40°C to +80°C
• Ingress protection: IP20
Características• Integrated design eliminates assembly errors
• Combined overload, short‑circuit and earth‑leakage protection
• Isolation function for safe maintenance
• Eco‑friendly, mercury‑free, sustainable packaging
  1. Principais recursos & Benefits
  2. Type A earth leakage protection: Compared with Type AC, detects pulsating DC leakage, ideal for modern electronic loads
  3. Factory-preassembled design: Breaker and leakage module assembled at factory to avoid on-site misassembly hazards
  4. Econômico: Easy9 series optimized for residential / commercial final distribution, balancing performance and cost
  5. Safe and reliable: Complies with international and national standards; 6kA breaking capacity handles common short-circuit faults
  6. Eco-certified: Green Premium product compliant with major global environmental regulations
  7. Aplicativos & Installation Recommendations

Aplicações Típicas:

Protection for residential lighting and socket circuits

Power distribution in small commercial buildings

Power supply for leakage-sensitive electronic equipment

Final distribution in offices, shops and similar premises

Notas de instalação:

Mount on standard 35mm DIN rail

Ensure load current does not exceed rated 10A

Suitable for TT, TN-S, TN-C-S earthing systems

Use appropriate cable cross-section (recommended ≥1.5mm² copper conductor)

  1. Modelos Alternativos & Ordering Information

Full factory model: EA9RN2C1030CA (standard version)

Same-series alternatives:

1P+N version: EA9RN1C1030C

3P / 4P versions: EA9RN3C1030C / EA9RN4C1030C

Different ratings: EA9RN2C1630C (16UM), EA9RN2C2030C (20UM), etc..

Chinese brand equivalents: CHINT NXBLE-32 2P C10 30mA; DELIXI DZ47LE-32 2P C10 30mA

  1. Seleção & Safety Warnings
  2. 30mA residual protection is intended for personal shock protection, not equipment protection (higher IΔn required)
  3. C-curve suits general loads; for motors and inductive loads, D-curve devices are recommended
  4. Test the earth leakage function regularly after installation (using the test button)
  5. Operating temperature range: -25°C a +60°C; avoid installation in extreme environments

International Brand Equivalents & Full EA9RN Series List

Below are international brand replacements and full series order codes for EA9RN2C1030C (2P C10A 30mA Type A RCBO) for substitution and inventory management.

  1. International Brand Cross-Reference
MarcaSérieModeloParâmetros principaisQuebrando CapacidadeCódigo do pedido
ABBDS200DS202C M C10 A302P, C10A, 30mA, Type A6o2CSR272140R1104
ABBDS200 APRDS202CMA‑C10/0.03A2P, C10A, 30mA, Type A10oDS202CMA‑C10/0.03A
Siemens5SU95SU9326‑1CN102P, C10A, 30mA, Type A6o5SU9326‑1CN10
LegrandRX3RX3M2C10A302P, C10A, 30mA, Type A6oRX3M2C10A30
Eaton MoellerxEffectFRBDM‑C10/2/003‑G/A2P, C10A, 30mA, Type A6oFRBDM‑C10/2/003‑G/A
EatonPKZPKPM2‑10/2/C/003‑A2P, C10A, 30mA, Type A6oPKPM2‑10/2/C/003‑A
  1. Full Schneider EA9RN Series Model List (Standard Order Codes)

EA9RN series are factory-integrated RCBOs in the Easy9 range, with combinations of poles (1P+N / 2P / 3P / 4P), Curva C, corrente nominal (6A-63A), residual current (30mA / 100mA), Type A.

1P+N

Corrente nominal30mA (Type A)100mA (Type A)
6UMEA9RN1C0630CAEA9RN1C06100CA
10UMEA9RN1C1030CAEA9RN1C10100CA
16UMEA9RN1C1630CAEA9RN1C16100CA
20UMEA9RN1C2030CAEA9RN1C20100CA
25UMEA9RN1C2530CAEA9RN1C25100CA
32UMEA9RN1C3230CAEA9RN1C32100CA
40UMEA9RN1C4030CAEA9RN1C40100CA
50UMEA9RN1C5030CAEA9RN1C50100CA
63UMEA9RN1C6330CAEA9RN1C63100CA

2P

Corrente nominal30mA (Type A)100mA (Type A)
6UMEA9RN2C0630CAEA9RN2C06100CA
10UMEA9RN2C1030CA (Padrão)EA9RN2C10100CA
16UMEA9RN2C1630CAEA9RN2C16100CA
20UMEA9RN2C2030CAEA9RN2C20100CA
25UMEA9RN2C2530CAEA9RN2C25100CA
32UMEA9RN2C3230CAEA9RN2C32100CA
40UMEA9RN2C4030CAEA9RN2C40100CA
50UMEA9RN2C5030CAEA9RN2C50100CA
63UMEA9RN2C6330CAEA9RN2C63100CA

3P

Corrente nominal30mA (Type A)100mA (Type A)
6UMEA9RN3C0630CAEA9RN3C06100CA
10UMEA9RN3C1030CAEA9RN3C10100CA
63UMEA9RN3C6330CAEA9RN3C63100CA

4P

Corrente nominal30mA (Type A)100mA (Type A)
6UMEA9RN4C0630CAEA9RN4C06100CA
10UMEA9RN4C1030CAEA9RN4C10100CA
63UMEA9RN4C6330CAEA9RN4C63100CA
  1. Special Model Notes
  2. K variant: With overvoltage protection, suffix “K”, por exemplo, EA9RN2C1030CK
  3. Type AC vs Type A:

Tipo AC: Detects only AC earth leakage, marked AC or unmarked

Type A: Detects AC + pulsating DC leakage, marked A or CA

  1. Packing: Padrão 2 pcs/box, 12 pcs/carton (1 pc/box for some high-current models)
  2. Substitution Selection Guidelines
  3. Confirm leakage type: EA9RN2C1030C is Type A; prefer Type A replacements, avoid Type AC (especially for electronic loads)
  4. Verify breaking capacity: Original is 6kA; replacement should meet or exceed this value
  5. Match poles and tripping curve: 2P, Curva C (5–10×In)
  6. Check mounting dimensions: All fit 35mm DIN rail, occupy 2 módulos

Applications of Schneider EA9RN2C1030C

The EA9RN2C1030C is a 2P, C10A, 30mA, Type A integrated earth-leakage circuit breaker designed for residential and commercial final distribution, primarily for personal electric shock protection + overload and short-circuit protection for low-power circuits.

  1. residencial (Mais Comum)
  2. General lighting circuits

Living room, bedroom, study, corridor, balcony lighting for LED panels, downlights, ceiling lights; 10A is fully sufficient.

  1. Low-power socket circuits

Bedside sockets, study sockets, living room auxiliary sockets for table lamps, phone/laptop chargers, fãs, routers.

  1. Small loads in wet areas

Bathroom lighting / ventilation fans, small kitchen appliances (mini rice cookers, eggbeaters, kettles); 30mA provides effective shock protection.

  1. Old residential wiring upgrades

Upgrading existing 10A legacy circuits with modern RCBOs for improved safety.

  1. Office & Small Commercial
  2. Workstation power

Individual desks: PCs, monitors, impressoras, scanners and other light office equipment.

  1. Shop lighting

Main lighting in convenience stores, stationery shops, nail salons, milk tea shops.

  1. Low-voltage equipment power

CCTV cameras, card readers, small switches, wireless APs.

  1. Public area lighting

Corridors, stairwells, building lobbies, partial underground garage lighting.

  1. Light Industrial & Auxiliary Engineering
  2. Control circuit power

Control supplies for small fans, bombas, automation systems.

  1. Temporary power

Construction site dorm lighting, exhibition and event temporary low-voltage distribution.

  1. Small branch circuits in distribution boards

Final sub-circuit protection with combined overload, short-circuit and earth-leakage functions.

  1. Special Applications for Type A Leakage Protection

This device supports Type A earth leakage detection of pulsating DC components, making it superior to standard Type AC for:

LED lighting and electronically ballasted lighting circuits

Switching power supplies, adapters, small variable-frequency devices

Damp environments requiring high sensitivity and reliability

Unsuitable Applications (Important)

High-power loads such as air conditioners, aquecedores elétricos de água, induction cookers, fornos, instantaneous water heaters (easily exceed 10A)

Heavy industrial motors and large machinery

Main circuits requiring 100mA / 300mA equipment-level earth leakage protection

Anterior:

Deixe uma resposta

Deixe um recado