2-Pole Type A Disjuntor Operado por Corrente Residual (RCBO) from the Easy9 series, factory-assembled integrated design, fornecendo proteção tripla contra sobrecarga, short-circuit and earth leakage
Parâmetros principais: Rated current 10A, C-curve tripping characteristic (5–10×In), rated residual operating current 30mA, capacidade de interrupção 6kA, rated voltage 230/400V AC
Aplicativos: Low-voltage final distribution in residential and commercial buildings; especially suitable for loads sensitive to pulsating DC earth leakage (por exemplo, electronic equipment, lighting systems)
Certificações & Ambiente: Complies with GB 16917 / CEI 601009, CCC certified, Green Premium product, meets RoHS / REACH requirements
- Model Number Breakdown
| Segment | Descrição |
| EA9RN | Easy9 series, electronic RCBO (factory‑preassembled) |
| 2 | 2‑Pole (2P) proteção |
| C | C‑curve tripping characteristic (for general lighting and distribution) |
| 10 | Rated current 10A |
| 30 | Rated residual operating current 30mA |
| C | Type A earth leakage protection (detects AC + pulsating DC leakage) |
- Complete Technical Data
| Categoria | Especificações |
| Elétrica | • Rated voltage: 230/400V e |
| • Rated frequency: 50/60Hz | |
| • Rated current (Em): 10UM | |
| • Tripping characteristic: C‑curve (5–10×In) | |
| • Rated residual operating current (IΔn): 30mA | |
| • Residual current type: Type A | |
| • Breaking capacity (Icn): 6o | |
| • Rated short‑time withstand current (Icw): 1kA/1s | |
| Mecânico & Environmental | • Mechanical endurance: 20,000 operações |
| • Electrical endurance: 4,000 operações | |
| • Mounting: 35mm trilho DIN | |
| • Operating temperature: ‑25°C to +60°C | |
| • Storage temperature: ‑40°C to +80°C | |
| • Ingress protection: IP20 | |
| Características | • Integrated design eliminates assembly errors |
| • Combined overload, short‑circuit and earth‑leakage protection | |
| • Isolation function for safe maintenance | |
| • Eco‑friendly, mercury‑free, sustainable packaging |
- Principais recursos & Benefits
- Type A earth leakage protection: Compared with Type AC, detects pulsating DC leakage, ideal for modern electronic loads
- Factory-preassembled design: Breaker and leakage module assembled at factory to avoid on-site misassembly hazards
- Econômico: Easy9 series optimized for residential / commercial final distribution, balancing performance and cost
- Safe and reliable: Complies with international and national standards; 6kA breaking capacity handles common short-circuit faults
- Eco-certified: Green Premium product compliant with major global environmental regulations
- Aplicativos & Installation Recommendations
Aplicações Típicas:
Protection for residential lighting and socket circuits
Power distribution in small commercial buildings
Power supply for leakage-sensitive electronic equipment
Final distribution in offices, shops and similar premises
Notas de instalação:
Mount on standard 35mm DIN rail
Ensure load current does not exceed rated 10A
Suitable for TT, TN-S, TN-C-S earthing systems
Use appropriate cable cross-section (recommended ≥1.5mm² copper conductor)
- Modelos Alternativos & Ordering Information
Full factory model: EA9RN2C1030CA (standard version)
Same-series alternatives:
1P+N version: EA9RN1C1030C
3P / 4P versions: EA9RN3C1030C / EA9RN4C1030C
Different ratings: EA9RN2C1630C (16UM), EA9RN2C2030C (20UM), etc..
Chinese brand equivalents: CHINT NXBLE-32 2P C10 30mA; DELIXI DZ47LE-32 2P C10 30mA
- Seleção & Safety Warnings
- 30mA residual protection is intended for personal shock protection, not equipment protection (higher IΔn required)
- C-curve suits general loads; for motors and inductive loads, D-curve devices are recommended
- Test the earth leakage function regularly after installation (using the test button)
- Operating temperature range: -25°C a +60°C; avoid installation in extreme environments
International Brand Equivalents & Full EA9RN Series List
Below are international brand replacements and full series order codes for EA9RN2C1030C (2P C10A 30mA Type A RCBO) for substitution and inventory management.
- International Brand Cross-Reference
| Marca | Série | Modelo | Parâmetros principais | Quebrando Capacidade | Código do pedido |
| ABB | DS200 | DS202C M C10 A30 | 2P, C10A, 30mA, Type A | 6o | 2CSR272140R1104 |
| ABB | DS200 APR | DS202CMA‑C10/0.03A | 2P, C10A, 30mA, Type A | 10o | DS202CMA‑C10/0.03A |
| Siemens | 5SU9 | 5SU9326‑1CN10 | 2P, C10A, 30mA, Type A | 6o | 5SU9326‑1CN10 |
| Legrand | RX3 | RX3M2C10A30 | 2P, C10A, 30mA, Type A | 6o | RX3M2C10A30 |
| Eaton Moeller | xEffect | FRBDM‑C10/2/003‑G/A | 2P, C10A, 30mA, Type A | 6o | FRBDM‑C10/2/003‑G/A |
| Eaton | PKZ | PKPM2‑10/2/C/003‑A | 2P, C10A, 30mA, Type A | 6o | PKPM2‑10/2/C/003‑A |
- Full Schneider EA9RN Series Model List (Standard Order Codes)
EA9RN series are factory-integrated RCBOs in the Easy9 range, with combinations of poles (1P+N / 2P / 3P / 4P), Curva C, corrente nominal (6A-63A), residual current (30mA / 100mA), Type A.
1P+N
| Corrente nominal | 30mA (Type A) | 100mA (Type A) |
| 6UM | EA9RN1C0630CA | EA9RN1C06100CA |
| 10UM | EA9RN1C1030CA | EA9RN1C10100CA |
| 16UM | EA9RN1C1630CA | EA9RN1C16100CA |
| 20UM | EA9RN1C2030CA | EA9RN1C20100CA |
| 25UM | EA9RN1C2530CA | EA9RN1C25100CA |
| 32UM | EA9RN1C3230CA | EA9RN1C32100CA |
| 40UM | EA9RN1C4030CA | EA9RN1C40100CA |
| 50UM | EA9RN1C5030CA | EA9RN1C50100CA |
| 63UM | EA9RN1C6330CA | EA9RN1C63100CA |
2P
| Corrente nominal | 30mA (Type A) | 100mA (Type A) |
| 6UM | EA9RN2C0630CA | EA9RN2C06100CA |
| 10UM | EA9RN2C1030CA (Padrão) | EA9RN2C10100CA |
| 16UM | EA9RN2C1630CA | EA9RN2C16100CA |
| 20UM | EA9RN2C2030CA | EA9RN2C20100CA |
| 25UM | EA9RN2C2530CA | EA9RN2C25100CA |
| 32UM | EA9RN2C3230CA | EA9RN2C32100CA |
| 40UM | EA9RN2C4030CA | EA9RN2C40100CA |
| 50UM | EA9RN2C5030CA | EA9RN2C50100CA |
| 63UM | EA9RN2C6330CA | EA9RN2C63100CA |
3P
| Corrente nominal | 30mA (Type A) | 100mA (Type A) |
| 6UM | EA9RN3C0630CA | EA9RN3C06100CA |
| 10UM | EA9RN3C1030CA | EA9RN3C10100CA |
| … | … | … |
| 63UM | EA9RN3C6330CA | EA9RN3C63100CA |
4P
| Corrente nominal | 30mA (Type A) | 100mA (Type A) |
| 6UM | EA9RN4C0630CA | EA9RN4C06100CA |
| 10UM | EA9RN4C1030CA | EA9RN4C10100CA |
| … | … | … |
| 63UM | EA9RN4C6330CA | EA9RN4C63100CA |
- Special Model Notes
- K variant: With overvoltage protection, suffix “K”, por exemplo, EA9RN2C1030CK
- Type AC vs Type A:
Tipo AC: Detects only AC earth leakage, marked AC or unmarked
Type A: Detects AC + pulsating DC leakage, marked A or CA
- Packing: Padrão 2 pcs/box, 12 pcs/carton (1 pc/box for some high-current models)
- Substitution Selection Guidelines
- Confirm leakage type: EA9RN2C1030C is Type A; prefer Type A replacements, avoid Type AC (especially for electronic loads)
- Verify breaking capacity: Original is 6kA; replacement should meet or exceed this value
- Match poles and tripping curve: 2P, Curva C (5–10×In)
- Check mounting dimensions: All fit 35mm DIN rail, occupy 2 módulos
Applications of Schneider EA9RN2C1030C
The EA9RN2C1030C is a 2P, C10A, 30mA, Type A integrated earth-leakage circuit breaker designed for residential and commercial final distribution, primarily for personal electric shock protection + overload and short-circuit protection for low-power circuits.
- residencial (Mais Comum)
- General lighting circuits
Living room, bedroom, study, corridor, balcony lighting for LED panels, downlights, ceiling lights; 10A is fully sufficient.
- Low-power socket circuits
Bedside sockets, study sockets, living room auxiliary sockets for table lamps, phone/laptop chargers, fãs, routers.
- Small loads in wet areas
Bathroom lighting / ventilation fans, small kitchen appliances (mini rice cookers, eggbeaters, kettles); 30mA provides effective shock protection.
- Old residential wiring upgrades
Upgrading existing 10A legacy circuits with modern RCBOs for improved safety.
- Office & Small Commercial
- Workstation power
Individual desks: PCs, monitors, impressoras, scanners and other light office equipment.
- Shop lighting
Main lighting in convenience stores, stationery shops, nail salons, milk tea shops.
- Low-voltage equipment power
CCTV cameras, card readers, small switches, wireless APs.
- Public area lighting
Corridors, stairwells, building lobbies, partial underground garage lighting.
- Light Industrial & Auxiliary Engineering
- Control circuit power
Control supplies for small fans, bombas, automation systems.
- Temporary power
Construction site dorm lighting, exhibition and event temporary low-voltage distribution.
- Small branch circuits in distribution boards
Final sub-circuit protection with combined overload, short-circuit and earth-leakage functions.
- Special Applications for Type A Leakage Protection
This device supports Type A earth leakage detection of pulsating DC components, making it superior to standard Type AC for:
LED lighting and electronically ballasted lighting circuits
Switching power supplies, adapters, small variable-frequency devices
Damp environments requiring high sensitivity and reliability
Unsuitable Applications (Important)
High-power loads such as air conditioners, aquecedores elétricos de água, induction cookers, fornos, instantaneous water heaters (easily exceed 10A)
Heavy industrial motors and large machinery
Main circuits requiring 100mA / 300mA equipment-level earth leakage protection
Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

















NH42-63-318x560.png)




