Schneider CVS Series MCCB (Molded Case Circuit Breaker)
Model Explanation: MCCB‑CVS160F‑3P‑125A
MCCB: Molded Case Circuit Breaker
CVS: Schneider CVS Series MCCB
160: Frame rating current 160A
F: Breaking capacity class, Type F: 36kA@400VAC
3P: 3 postes (three‑phase three‑wire)
125UM: Rated operational current 125A
Parâmetros Básicos
Type: Molded Case Circuit Breaker
Série: CVS
Frame current: 160UM
Corrente nominal: 125UM
Poloneses: 3P
Capacidade de ruptura: 36o
Application: Three‑phase power distribution protection
Below are the key engineering data for Schneider MCCB‑CVS160F‑3P‑125A (Order No. LV516332) for direct selection, panel layout and replacement.
- Dimensões (Fixed Mounted Type)
| Dimension | Value | Notas |
| Largura (C) | 90milímetros | Standard 3P width |
| Altura (H) | 185milímetros | Including handle |
| Profundidade (D) | 105milímetros | Excl. terminais; aprox.. 120mm incl. terminais |
| Mounting hole spacing | 75mm*150mm | 4*M6 mounting holes |
| Degree of protection | IP40 | Complies with IEC 60529 |
- Connection Method
- Padrão: Front connection, padrão, no extra accessories required
- Opcional:
Rear connection: requires dedicated rear connection base
Plug‑in connection: requires plug‑in base for quick replacement
- Connection Specifications:
Copper bar: máx.. 120mm² (recommended)
Cable: máx.. 150mm² (copper), cable lugs recommended
Rated torque: M10 bolt, 25N·m
- Recommended Replacement Models
3.1 Schneider Direct Replacements
| Série | Modelo | Características | Compatibilidade |
| CVS Original | CVS160F TM125D 3P3D (LV516332) | Identical, direct replacement | Fully compatible |
| NSX (Premium) | NSX160F TM125D 3P3D (LV430632) | Higher breaking capacity (70kA@400V), optional electronic trip | Mesmas dimensões, enhanced functions |
| EZD (Economic) | EZD160E TMD125 3P | Lower cost, 25kA@400V | Mesmas dimensões, lower breaking capacity |
3.2 Other Brands
| Marca | Modelo | Matching Parameters |
| ABB | Tmax T2N160 TMD125 3P | Frame 160A, In 125A, 36o |
| Siemens | 3VL1716‑1DD33‑0AA0 | Frame 160A, In 125A, 36o |
| Chint | NXM‑160S/3300 125A | Frame 160A, In 125A, 36o |
- Additional Notes
- Trip unit: TM‑D thermal‑magnetic, adjustable overload (87.5–125A), fixed short‑circuit (≈10In)
- Capacidade de ruptura: 36kA@400VAC, complies with IEC 60947‑2
- Mounting: Fixed (padrão), plug‑in (opcional), withdrawable (opcional)
Complete List of Equivalent Replacements for Schneider MCCB‑CVS160F‑3P‑125A
All below match key parameters: frame 160A, In 125A, 3P, 36kA@400V, thermal‑magnetic trip, suitable for direct engineering replacement.
- Schneider Direct Replacements (Seamless Compatibility)
| Série | Modelo | Order No. | Características | Compatibilidade |
| CVS Original | CVS160F TM125D 3P3D | LV516332 | Identical, direct replacement | 100% compatible |
| NSX Premium | NSX160F TM125D 3P3D | LV430632 | 70kA@400V, optional electronic trip | Mesmas dimensões |
| EZD Economic | EZD160E TMD125 3P | LV510332 | Cost‑effective, 25kA@400V | Mesmas dimensões |
- International Brand Equivalents
ABB
| Série | Modelo | Parâmetros principais | Características |
| 3VL | 3VL1716‑1DD33‑0AA0 | 160Um quadro, 125UM, 36o | Projeto modular |
| 3VT | 3VT8116‑1AA03‑0AA0 | Thermal‑magnetic, 36o, 3P | Economic, reliable |
Siemens
| Série | Modelo | Parâmetros principais | Características |
| 3VL | 3VL1716‑1DD33‑0AA0 | 160Um quadro, 125UM, 36o | Projeto modular |
| 3VT | 3VT8116‑1AA03‑0AA0 | Thermal‑magnetic, 36o, 3P | Economic, reliable |
Eaton Moeller
| Série | Modelo | Parâmetros principais | Características |
| NZM | NZM2‑160 TM125 3P | 160Um quadro, 125UM, 36o | High reliability for industry |
- Chinese Domestic Brands (Cost‑Effective)
Chint
| Série | Modelo | Parâmetros principais | Características |
| NXM | NXM‑160S/3300 125A | 160UM, 125UM, 36o | High cost‑performance |
| CDM6i | CDM6i‑160M/3300B 125A | Thermal‑magnetic, 36o, fixed | Smart options available |
Delicioso
| Série | Modelo | Parâmetros principais | Características |
| CDM3 | CDM3‑160S/3300 125A | 160UM, 125UM, 36o | Stable performance |
| CDM1 | CDM1‑160L/3300 125A | Thermal‑magnetic, 36o, 3P | Proven classic |
TENGEN
| Série | Modelo | Parâmetros principais | Características |
| TGM1 | TGM1‑160L/3300 125A | 160UM, 125UM, 36o | Reliable domestic choice |
- Key Selection Criteria
4.1 Core Parameter Matching Table
| Item | Original Requirement | Replacement Must Meet |
| Frame current | 160UM | 160UM |
| Corrente nominal | 125UM | 125UM |
| Poloneses | 3P | 3P |
| Capacidade de ruptura | 36kA@400V | ≥ 36kA@400V |
| Tipo de viagem | Thermal‑magnetic (TM‑D) | Thermal‑magnetic (TMD/TMF) |
| Mounting | Fixed | Fixed (or with adapter) |
| Connection | Front | Front (or with adapter) |
4.2 Notas de substituição
- Dimensões: Most replacements: W90mm × H185mm × D105mm, direct fit
- Trip characteristics: Overload 87.5–125A, short‑circuit ≈10In must match
- Accessories: Check compatibility for auxiliary contacts, undervoltage release, etc..
- Certification: CEI / GB certified
- Recommended Solutions
| Application | Recommended Model | Reason |
| Original replacement | Schneider CVS160F TM125D 3P3D | Identical, zero risk |
| Performance upgrade | ABB T2N160 TMD125 3P or Siemens 3VL1716‑1DD33‑0AA0 | International brand, reliable |
| Cost control | Chint NXM‑160S/3300 125A or Delixi CDM3‑160S/3300 125A | Cost‑effective, good local support |
Contator,disjuntor,inversor solar,medidor elétrico,baterias solares