  • Detalhes do produto

Visão geral do produto

Schneider SR2A201BD is a compact smart relay (programmable logic controller) from the Zelio Logic SR2 series, used for the management, controle remoto, and monitoring of simple automation systems. It is an upgraded replacement for the SR1‑A201BD, offering enhanced functions. Suitable for industrial and commercial applications, it is an ideal alternative to traditional relay logic control and dedicated control cards.

  1. Resumo dos parâmetros principais
Categoria de parâmetroEspecificações detalhadas
Informações básicas• Type: Compact smart relay
• Series: Zelio Logic SR2
• Model: SR2A201BD
• Supply voltage: 24 CCV
• Mostrar: With LCD (no clock function)
• Programming software: Zelio Soft 2
Configuração de E/S• Total I/O points: 20
• Digital inputs: 12 (EN/IEC 61131‑2 type 1)
• Analog inputs: 2 (tipo universal)
• Digital outputs: 8 (saída de relé)
• Output form: 4 contatos de mudança (4PDT‑NO, NC)
Características Elétricas• Input current: máx.. 4 mA
• Counting frequency: 1 kHz (discrete inputs)
• Relay output rating: ≥10 mA @ 12V; 1.5UM (CA‑12), 0.9UM (CA‑15) at 230V rated
• Mechanical life: 10,000,000 ciclos (saída de relé)
• Electrical life: 500,000 ciclos
• Power consumption: 6 C (without extension modules)
• Reverse polarity protection: Sim
Desempenho• Program capacity: Ladder ≤120 lines, FBD ≤200 lines
• Cycle time: 6–90 ms
• Backup time: 10 anos (a 25°C)
• Clock drift: 6 s/month (25°C), 12 min/year (0–55°C)
• Impulse withstand voltage: 4 kV (EN/IEC 60947‑1)
Condições ambientais• Temperatura operacional: -20°C ~ 55 °C
• Protection rating: IP20 (frente)
• Montagem: Trilho DIN
  1. Dimensões & Physical Features

Dimensões: Standard DIN‑rail mount, width approx. 70 milímetros, height approx. 90 milímetros, depth approx. 60 milímetros (subject to official data)

Peso: aprox.. 0.38 kg

Terminais: Screw‑clamp terminals, reliable connection, fácil manutenção

Mounting recommendation: 15 mm standard galvanized steel DIN rail (por exemplo, Schneider AM1DE200)

  1. Substituição & Compatibilidade
  2. Substituição direta: SR1‑A201BD (descontinuado)
  3. Same‑series replacements / upgrades:

SR2A201FU: 24CCV, 20E/S, with display, no clock (functionally identical, minor differences possible)

SR2A201E: 24CCV, 20E/S, sem exibição, no clock

SR2B201BD: 24CCV, 20E/S, with display, with real‑time clock

  1. Cross‑series compatibility: Can be used with SR3 series extension modules to expand I/O and functions.
  2. Acessórios recomendados
Tipo de acessórioModeloDescrição
Programming cableSR2‑USB01USB programming cable (3 eu), connects PC to smart relay
Software de programaçãoZelio Soft 2Official software, supports Ladder (LD) and FBD
Extension modulesSR3XT seriesExpand I/O: digital, analógico, comunicação
Mounting accessory15 mm trilho DINStandard mounting rail, Schneider AM1DE200 recommended
ProteçãoCapa protetora contra poeiraProtects front interface and display
  1. Aplicativos

Automação industrial: Pequenas linhas de produção, manuseio de materiais, máquinas de embalagem

Edifícios comerciais: Controle de iluminação, Controle de climatização, controle de acesso

Infraestrutura: Controle da bomba, compressor management, wastewater treatment

Outros: Máquinas de venda automática, lift control, agricultural automation

  1. Programação & Solução de problemas

Programming Features

Supports Ladder Diagram (LD) and Function Block Diagram (DCT) per IEC 61131‑3

Built‑in EEPROM: program and data retained for 10 years after power loss

Program memory self‑test on power‑up

Falhas Comuns

  1. Falha de energia: Check 24VDC supply and polarity (reverse protected)
  2. Input not responding: Verify signal type/voltage, verifique a fiação
  3. Output not operating: Check load within rating, inspect output contacts
  4. Program lost: Reload via Zelio Soft 2, check backup battery (if fitted)
  5. Exibição anormal: Power cycle, check ambient temperature
  6. Notas de seleção
  7. Confirm supply voltage 24VDC matches field power
  8. E/S: 12 entradas / 8 saídas (incluindo 2 analógico)
  9. Tipo de saída: Relay output suitable for AC/DC loads; observe current limits
  10. Mostrar: LCD aids on‑site commissioning and diagnostics
  11. Relógio: No clock on this model; choose SR2B201BD for timing functions

Complete Guide to Schneider SR2A201BD Replacements

  1. Core Replacement Overview

Schneider SR2A201BD is a compact Zelio Logic SR2 smart relay. Below is a complete list of replacements sorted by type and functional differences for quick selection.

  1. Detailed Replacement List
  2. Substituição Direta (Identical Function)
ModeloEspecificações principaisDifference from SR2A201BD
SR2A201FU24CCV, 20E/S (12DI+2AI+8RO), LCD, no clockFully interchangeable, only batch/process differences
SR1‑A201BD24CCV, 20E/S, with display, no clockPredecessor, descontinuado; SR2A201BD is official upgrade
  1. Same‑Series Functional Replacements
ModeloEspecificações principaisAplicativo
SR2B201BD24CCV, 20E/S, LCD, with RTCFor timing / time control
SR2D201BD24CCV, 20E/S, no LCD, no clockCost‑optimized, no local display
SR2E201BD24CCV, 20E/S (12DI+6AI+8RO), LCD, no clockFor more analog inputs (6 IA)
SR2A201E24CCV, 20E/S, sem exibição, no clockBasic low‑cost version
  1. Tensão / Output Type Replacements
ModeloEspecificações principaisAplicativo
SR2A201BD‑AC100–240VAC, 20E/S, display, no clockFor AC mains supply
SR2A201BD‑DO24CCV, 20E/S (12DI+2AI+8DO transistor)For DC loads, higher switching frequency
  1. Upgrade Replacements (Expanded Functions)
ModeloSériePrincipais melhoriasAplicativo
SR3B261BDSR3 (modular)26I/O base, expandable to 40I/O, clock + displayFor expansion, comunicação, mais E/S
SR3XT seriesSR3Extensions for SR2A201BD: E/S & comunicaçãoUpgrade existing system without replacing main unit
  1. Guia de seleção de substituição
ExigênciaModelo recomendadoKey Reason
Identical functionSR2A201FU100% compatível
Real‑time clockSR2B201BDBuilt‑in RTC
No local displaySR2D201BDMenor custo
More analog inputsSR2E201BD6 AI instead of 2
AC supplySR2A201BD‑ACMatches mains voltage
High‑speed DC outputSR2A201BD‑DOSaída transistorizada
System expansionSR3B261BDModular, expandable I/O & comms
Legacy system repairSR1‑A201BDFor old discontinued SR1 units
  1. Notas de substituição
  2. Software compatibility: All SR2 models work with Zelio Soft 2; programs portable
  3. Compatibilidade de montagem: Standard DIN‑rail, mesmas dimensões (~70×90×60 mm)
  4. Wiring compatibility: Identical terminal layout, no rewiring needed
  5. Function check: Relógio, display, analog input count must match application
  6. Peças de reposição: Prefer SR2A201FU / SR2B201BD for long‑term availability

Schneider SR2A201BD Programming Software

The official programming software for Schneider SR2A201BD is Zelio Soft 2 (latest version: v5.4.2.2). It is a free configuration and programming tool developed by Schneider Electric for Zelio Logic smart relays (SR2 and SR3 series), used for managing, monitoramento, and controlling simple automation systems.

  1. Core Software Information
ItemDetalhes
ProgramasZelio Soft 2 (Zelio2)
Versão mais recentev5.4.2.2 (updated July 2022)
DeveloperSchneider Elétrica
TipoFreeware
SOWindows XP/Vista/7/8/10/11 (32/64-pedaço)
Project file.zm2
CaboDedicated USB cable: SR2‑USB01 (3 eu)
  1. Principais recursos
  2. Multi‑language programming

Supports Ladder (LD) and FBD (IEC 61131‑3)

Built‑in function library: logic, timers, contadores, comparators, math

  1. Debug & simulation

Offline simulation without hardware

Online monitoring of I/O, variables, and execution

Breakpoint debugging

  1. Project management

Upload / download programs

Backup de dados; EEPROM retention 10 anos

Auto‑generated documentation

  1. Diagnóstico

E/S, program, and communication fault detection

Status, error codes, event logs

  1. Compatibilidade & Notas de uso
  2. Series compatibility

Full support for SR2 series (SR2A201BD, SR2B201BD, SR2D201BD, etc.) and SR3 modular smart relays

Imports and converts SR1 series (por exemplo, SR1‑A201BD) programs

  1. Connection requirements

Use only SR2‑USB01; standard USB cables not supported

Install driver (included in setup)

Unit must be powered (24CCV) for programming

  1. Limitações

No SFC (Sequential Function Chart) apoiar

Program limits: Ladder ≤120 lines, FBD ≤200 lines

No serial link to HMI (por exemplo, Magelis/Harmony)

  1. Etapas de instalação
  2. Disable antivirus/firewall temporarily
  3. Run installer and follow wizard
  4. Connect SR2‑USB01 and install driver
  5. Launch software, create or open project
  6. Alternativas & Atualizações
AplicativoRecomendaçãoNotas
Temporary programmingZelio Soft 2 online trialLimited functions
Atualização do sistemaSR3 series + Zelio Soft 2More I/O, comunicação, SFC
Advanced applicationsEcoStruxure Machine ExpertLatest Schneider software suite

Complete Model Guide for Schneider Zelio Logic SR2 Series

The Schneider Zelio Logic SR2 series is a product line of compact smart relays, designed specifically for simple automation systems. It offers three fixed I/O configurations: 10/12/20 pontos, with various combinations of power supply, display, clock, and analog inputs to meet different application requirements. Below is a detailed list of all series models classified by function:

  1. Regras de nomenclatura de modelo (Quick Identification)

SR2 [Código de Função] [Pontos de E/S] [Voltage Code]

Código de Função:

UM: With LCD display, no clock

B: With LCD display, with real-time clock

D: No LCD display, no clock

E: With LCD display, more analog inputs, no clock

Pontos de E/S: 10, 12, 20

Voltage Code:

BD: 24 CCV

FU: 100–240 VAC

JD: 12 CCV

  1. Complete Model List for SR2 Series (Classified by I/O Points)
  2. 10 I/O Points Models (6DE + 4RO, no analog input)
ModeloTensão de alimentaçãoMostrarRelógioPrincipais recursosAplicações Típicas
SR2A101BD24 CCVSimNãoTipo básico, with display for easy debuggingSimple control, on-site status monitoring
SR2A101FU100–240 VACSimNãoAC supply version, with displayEdifícios comerciais, AC-powered environments
SR2A101JD12 CCVSimNãoLow-voltage version, with displayVehicle/mobile equipment, 12Alimentação V
SR2B101BD24 CCVSimSimWith real-time clock, time controlSimple systems requiring time control
SR2B101FU100–240 VACSimSimAC + clock + displayCommercial time control (por exemplo, iluminação)
SR2B101JD12 CCVSimSim12V + clock + displayTime control for mobile devices
SR2D101BD24 CCVNãoNãoOtimizado em termos de custos, sem exibiçãoFixed programs, no on-site debugging
SR2D101FU100–240 VACNãoNãoAC + sem exibiçãoLow-cost mass applications
SR2D101JD12 CCVNãoNão12V + sem exibiçãoLow-power simple control
  1. 12 I/O Points Models (8DE + 4RO, basic version with 2AI)
ModeloTensão de alimentaçãoMostrarRelógioEntradas AnalógicasPrincipais recursosAplicações Típicas
SR2A121BD24 CCVSimNão2Standard 12-point, with displayPequeno & medium equipment control
SR2A121FU100–240 VACSimNão2Standard AC versionCommercial automation
SR2A121JD12 CCVSimNão2Standard 12V versionMobile equipment control
SR2B121BD24 CCVSimSim2With clock, 2 IATiming & analog monitoring
SR2B121FU100–240 VACSimSim2AC + clock + 2 IABasic HVAC control
SR2B121JD12 CCVSimSim212V + clock + 2 IAVehicle temperature control
SR2D121BD24 CCVNãoNão2Sem exibição, 2 IAFixed programs + entradas analógicas
SR2D121FU100–240 VACNãoNão2AC + sem exibição + 2 IAMass production equipment
SR2E121BD24 CCVSimNão4Atualizado para 4 IAApplications needing more analog detection
SR2E121FU100–240 VACSimNão4AC + 4 IAEnvironmental monitoring systems
  1. 20 I/O Points Models (12DE + 8RO, standard version with 2AI)
ModeloTensão de alimentaçãoMostrarRelógioEntradas AnalógicasPrincipais recursosAplicações Típicas
SR2A201BD24 CCVSimNão2Standard 20-point, with displayProduction line control, manuseio de materiais
SR2A201FU100–240 VACSimNão2Standard AC versionComplex control in commercial buildings
SR2A201JD12 CCVSimNão2Standard 12V versionLarge mobile equipment
SR2B201BD24 CCVSimSim2With clock, 2 IAComplex control with timing functions
SR2B201FU100–240 VACSimSim2AC + clock + 2 IAAdvanced HVAC control
SR2B201JD12 CCVSimSim212V + clock + 2 IASpecial vehicle control
SR2D201BD24 CCVNãoNão2Sem exibição, 2 IAComplex systems with fixed programs
SR2D201FU100–240 VACNãoNão2AC + sem exibição + 2 IAMass production lines
SR2E201BD24 CCVSimNão6Atualizado para 6 IAControle de processo, multi-parameter monitoring
SR2E201FU100–240 VACSimNão6AC + 6 IAEnvironmental monitoring centers
  1. Modelos Especiais & Acessórios
  2. Special Output Type Models

SR2A201BD-DO: 24 CCV, 20 E/S, with display, no clock, 8 transistor outputs (instead of relay), suitable for high-speed DC loads

SR2B121BD-DO: 24 CCV, 12 E/S, with display and clock, 4 transistor outputs

  1. Extension Module Compatibility

All SR2 series models can work with SR3XT series extension modules to expand I/O points and functions:

SR3XT02BD: 2 digital input extension

SR3XT04BD: 4 digital output extension (relé)

SR3XT02AI: 2 analog input extension

SR3XT01AO: 1 analog output extension

SR3XTCOM: Communication extension module (supports Modbus RTU)

  1. Programação & Acessórios de montagem
Modelo de acessórioDescrição
SR2-USB01Dedicated USB programming cable (3eu), connects PC to SR2 smart relay
Zelio Soft 2Official programming software (latest v5.4.2.2), supports LD and FBD programming
AM1DE20015 mm standard DIN rail for SR2 series mounting
SR2PACKSoftware de programação + USB cable kit, ideal for new users
  1. Selection Quick Reference
ExigênciaRecommended Model SeriesPrincipais fatores de seleção
Minimal system (10 E/S)SR2A101xx / SR2B101xxPower type, clock/display needed
Standard system (12 E/S)SR2A121xx / SR2B121xxAnalog input requirement (2/4 canais)
Sistema complexo (20 E/S)SR2A201xx / SR2B201xxEntrada analógica (2/6 canais), tipo de saída
Timing controlSR2Bxxx seriesMust have real-time clock
No on-site debuggingSR2Dxxx seriesSem exibição, menor custo
Multi-analog detectionSR2Exxx series4 (12 E/S) ou 6 (20 E/S) IA
High-speed DC outputSR2xxx-DO seriesTransistor output instead of relay
Fonte de alimentação CASR2xxxFU seriesUniversal 100–240 VAC
Low-voltage supplySR2xxxJD series12 CCV, suitable for mobile devices

All SR2 series models are compatible with Zelio Soft 2 programming software. Programs can be directly ported between different models in the same series. Mounting dimensions are uniform (aprox.. 70×90×60 mm), facilitating system upgrade and maintenance.