Siemens 3VA1180-3EF32-0AA0 MCCB

3VA1 series MCCB, 3 postes, frame current 160A, rated current 80A, breaking capacity 25kA@415V (Type N), thermal-magnetic trip unit TM240, adjustable overload protection 56–80A, adjustable short-circuit protection 5–10×In, fixed mounting, front connection. Model Code Explanation Code Segment Description 3VA1 Product series: 3VA1 series MCCB (thermal‑magnetic trip, standard application) 180 Frame current: 160UM (IEC Frame 160) ...

  • Detalhes do produto

3VA1 series MCCB, 3 postes, frame current 160A, rated current 80A, breaking capacity 25kA@415V (Type N), thermal-magnetic trip unit TM240, adjustable overload protection 56–80A, adjustable short-circuit protection 5–10×In, fixed mounting, front connection.

  1. Explicação do código do modelo
Segmento de códigoDescrição
3VA1Série de produtos: 3VA1 series MCCB (thermal‑magnetic trip, standard application)
180Frame current: 160UM (IEC Frame 160)
3Número de pólos: 3 postes
EFTipo de viagem: TM240 thermal‑magnetic trip unit, ATAM adjustable overload and short‑circuit protection
32Configuração de acessórios: standard version with nut mounting kit
0AA0Special function: no diagnostic function (0AB0 = with diagnostic function)
  1. Detailed Technical Parameters
Categoria de parâmetroValor
Especificações básicas
Product typeDisjuntor em caixa moldada (MCCB), SENTRON series
Tensão operacional nominal (main circuit)AC 690V, DC 250V
Tensão nominal de isolamento1000V CA/CC
Frame current (IEC Frame)160UM
Corrente nominal (Em)80UM
Número de pólos3 postes
Características de proteção
Tipo de viagemThermal‑magnetic (TM240), ATAM
Proteção contra sobrecarga (E)Ajustável, 56–80A
Short‑circuit protection (Ii)Ajustável, 5–10×In
Ultimate breaking capacity (UTI)25kA @ 415V (Type N)
Service breaking capacity (CIs)50% de UTI (12.5kA @ 415V)
Mecânico & Instalação
Tipo de montagemMontagem fixa
Connection typeConexão frontal, screw-type flat terminals
Operating typeManual operation
Ingress protectionIP40 (front)
Temperatura ambiente-25°C a +70°C (derating required at high temperatures)
Mechanical endurance10,000 operações (padrão)
Electrical endurance1,000 operações (at rated current)
  1. Condições ambientais & Aplicações Típicas
  2. Condições ambientais

Low-voltage distribution systems in industrial plants, commercial buildings and infrastructure

Temperatura ambiente: -25°C a +70°C (derating according to curve in high-temperature environments)

Altitude: ≤ 2000m (derating above this altitude)

Grau de poluição: 2 (standard industrial environment)

  1. Aplicações Típicas

Distribution line protection (cables, transformadores, generators)

Motor control circuit protection (used with contactors)

Protection of low-voltage loads such as lighting and air conditioning

Main or branch protection in distribution boards and switchgear

  1. Modelos Alternativos & Series Equivalents
  2. Siemens Same-Series Alternatives
ModeloPrincipal diferençaAplicativo
3VA1180-3ED32-0AA0Fixed overload protection (80UM), FTFMSimple applications without adjustable overload
3VA1180-5EF32-0AA0Breaking capacity 55kA (Type M)Systems with high short‑circuit current
3VA1180-6EF32-0AA0Breaking capacity 70kA (Type H)Industrial environments with high short‑circuit stress
3VA1180-3EF42-0AA04‑pole designThree‑phase four‑wire systems
  1. Cross-Brand Alternatives
MarcaModelo de substituiçãoCompatibilidade
SchneiderNSX100N TMD 80 3PAlto (25o, thermal‑magnetic trip)
ABBT1N160 TMD 80/800 FF 3PAlto (160Um quadro, 80A rated)
ChintNZM1-160H/3P 80AMédio (domestic equivalent, similar performance)
DeliciosoCW3-160N/3P 80AMédio (domestic alternative, econômico)
  1. Pedido & Notas de instalação
  2. Official order number: 3VA1180-3EF32-0AA0
  3. Installation precautions

Sufficient heat dissipation space must be reserved (≥10mm clearance)

Torque de aperto: M6 screws 10Nm, M8 screws 20Nm

Seção transversal do condutor: máx.. 17×6.5mm (copper bar) or 35mm² (cable)

  1. Compatibilidade de acessórios

Can be fitted with auxiliary contacts, contatos de alarme, viagem de manobra, liberação de subtensão

Supports extended rotary handles, door-coupled operating mechanisms

  1. Key Advantages
  2. Reliable protection: Thermal-magnetic trip provides dual overload and short-circuit protection, with adjustable ranges for various loads
  3. Flexible installation: Fixed mounting with front connection, compatible with standard switchgear and distribution boards
  4. Robust design: IP40 protection, 10,000 operações mecânicas, suitable for long-term industrial use
  5. Brand assurance: Siemens SENTRON series, compatível com IEC/EN 60947-2

Siemens MCCB Model List

  1. Core Series & Naming Rules

1.1 Main Product Series

Siemens MCCBs mainly include the 3VA series (nova geração) and 3VL/3VT series (legacy). The 3VA series covers frame currents from 100A to 1600A, divided into 3VA1 (viagem termomagnética) and 3VA2 (viagem eletrônica) sub-series.

1.2 3VA Series Naming Rule (Exemplo: 3VA1180-3EF32-0AA0)

SegmentCódigoSignificado
13VA1Série: 3VA1 = thermal‑magnetic, 3VA2 = electronic trip
2180Frame current: 100=100A, 160=160A, 250=250A, 400=400A, 630=630A
33Poloneses: 1=1P, 2=2P, 3=3P, 4=4P
4EFViagem + capacidade de interrupção: E=25kA, F=36kA, G=50kA, H=70kA, J=85kA; E=fixed thermal‑magnetic, F=adjustable thermal‑magnetic
532Accessory: 3=standard, 4=with auxiliary contact, 5=with shunt trip
60AA0Special function: 0AA0=no diagnostics, 0AB0=with diagnostics
  1. Complete Model List-3VA1 Series (Thermal-Magnetic TM Trip)

2.1 100A Frame (3VA1100)

ModeloCorrente nominalPolonesesTrip UnitQuebrando Capacidade
3VA1100-3EE32-0AA063UM3PTM220 (fixo)25kA@415V
3VA1100-3EF32-0AA063UM3PTM240 (ajustável)25kA@415V
3VA1100-4EE32-0AA063UM4PTM220 (fixo)25kA@415V
3VA1100-5EF32-0AA080UM3PTM240 (ajustável)36kA@415V

2.2 160A Frame (3VA1160/3VA1180)

ModeloCorrente nominalPolonesesTrip UnitQuebrando Capacidade
3VA1180-3EE32-0AA080UM3PTM220 (fixo)25kA@415V
3VA1180-3EF32-0AA080UM3PTM240 (adjustable 56–80A)25kA@415V
3VA1180-4EF32-0AA080UM4PTM240 (ajustável)25kA@415V
3VA1180-5EF32-0AA080UM3PTM240 (ajustável)36kA@415V
3VA1180-6EF32-0AA080UM3PTM240 (ajustável)50kA@415V
3VA1160-3EF32-0AA063UM3PTM240 (ajustável)25kA@415V

2.3 250A Frame (3VA1250)

ModeloCorrente nominalPolonesesTrip UnitQuebrando Capacidade
3VA1250-3EE32-0AA0160UM3PTM220 (fixo)25kA@415V
3VA1250-3EF32-0AA0160UM3PTM240 (adjustable 112–160A)25kA@415V
3VA1250-4EF32-0AA0160UM4PTM240 (ajustável)25kA@415V
3VA1250-5EF32-0AA0200UM3PTM240 (ajustável)36kA@415V

2.4 400A Frame (3VA1400)

ModeloCorrente nominalPolonesesTrip UnitQuebrando Capacidade
3VA1400-3EE32-0AA0250UM3PTM220 (fixo)25kA@415V
3VA1400-3EF32-0AA0250UM3PTM240 (adjustable 175–250A)25kA@415V
3VA1400-4EF32-0AA0250UM4PTM240 (ajustável)25kA@415V
3VA1400-6EF32-0AA0315UM3PTM240 (ajustável)50kA@415V

2.5 630A Frame (3VA1630)

ModeloCorrente nominalPolonesesTrip UnitQuebrando Capacidade
3VA1630-3EE32-0AA0400UM3PTM220 (fixo)25kA@415V
3VA1630-3EF32-0AA0400UM3PTM240 (adjustable 280–400A)25kA@415V
3VA1630-4EF32-0AA0400UM4PTM240 (ajustável)25kA@415V
3VA1630-7EF32-0AA0500UM3PTM240 (ajustável)70kA@415V
  1. Typical Models-3VA2 Series (Electronic ETU Trip)
ModeloQuadro atualCorrente nominalPolonesesTrip UnitQuebrando Capacidade
3VA2180-3MF32-0AA0160UM80UM3PETU200 (ajustável)25kA@415V
3VA2250-3MF32-0AA0250UM160UM3PETU200 (ajustável)25kA@415V
3VA2400-3MF32-0AA0400UM250UM3PETU200 (ajustável)25kA@415V
3VA2630-3MF32-0AA0630UM400UM3PETU200 (ajustável)25kA@415V
3VA2630-6MF32-0AA0630UM500UM3PETU200 (ajustável)50kA@415V
  1. Popular Models-Legacy Series (3VL/3VT)
SérieModeloQuadro atualCorrente nominalPolonesesQuebrando Capacidade
3VL3VL1701-1DD33-0AA0160UM80UM3P25kA@415V
3VL3VL2701-1DD33-0AA0250UM160UM3P25kA@415V
3VL3VL3701-1DD33-0AA0400UM250UM3P25kA@415V
3VT3VT8106-1AA03-0AA0160UM63UM3P25kA@415V
3VT3VT8207-1AA03-0AA0250UM100UM3P25kA@415V
  1. Selection Parameter Reference Table
Quadro atualFaixa atual nominalClasse de Capacidade de QuebraTipo de viagemTypical Application
100UM16–100A25–85kATM220/TM240Lighting, motores pequenos
160UM16–160A25–85kATM220/TM240Branch distribution, medium motors
250UM100–250A25–85kATM240Main distribution, large motors
400UM250–400A25–85kATM240/ETU200Main switch in distribution panels
630UM400–630A25–85kATM240/ETU200Substations, main factory distribution
  1. Pedido & Purchasing Tips
  2. Complete model: Provide full model code as shown (por exemplo, 3VA1180-3EF32-0AA0), including all six segments
  3. Accessory options: Contatos auxiliares (-4XX), shunt trips (-5XX), liberações de subtensão (-6XX), etc..
  4. Tipo de montagem: Fixed by default; specify plug-in type if required (-XX4X)
  5. Authorized channels: Purchase through Siemens authorized distributors or industrial platforms to ensure genuine products and warranty