Relé de segurança Wieland SNA-4053-K-A - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

Relé de segurança Wieland SNA-4053-K-A - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

elétrica/

Relé de segurança Wieland SNA-4053-K-A

SNA: Safety switch monitoring series (for monitoring emergency stop, safety gates, cortinas de luz de segurança) 4053: Specification code K: Pluggable screw terminals A: Supply voltage AC/DC 24 V Suffix differentiation for the series: A = AC/DC 24 V; C = Push-in spring terminals; KM = Automatic reset; KE = Special version Core Specifications & Classificações de segurança ...

  • Detalhes do produto

SNA: Safety switch monitoring series (for monitoring emergency stop, safety gates, cortinas de luz de segurança)

4053: Código de especificação

K: Pluggable screw terminals

UM: Supply voltage AC/DC 24 V

Suffix differentiation for the series:

A = AC/DC 24 V; C = Push-in spring terminals; KM = Automatic reset; KE = Special version

  1. Especificações principais & Classificações de segurança
  2. Certificações de segurança

PL e / Categoria 4 (EM ISO 13849-1)

SIL CL3 (EM 62061)

  1. Configuração de contato

3 safety normally open contacts (13-14 / 23-24 / 33-34)

1 normally closed signal contact (41-42)

  1. Dados elétricos

Fornecer: 24 V CA/CC

Continuous rated current Ith: 8 UM

AC-15: 230 V / 5 UM; DC-13: 24 V / 5 UM

Montagem: DE 35 trilho mm; Largura 22.5 milímetros

  1. Input Functions

Dual-channel safety circuit (S11/S12, S21/S22)

Supports cross-channel short-circuit monitoring

Reinicialização manual (with reset monitoring)

Adequado para: Botões de parada de emergência, safety gate switches, magnetic safety switches, cortinas de luz de segurança

  1. Typical Wiring Logic
  2. A1(+), A2(-): 24 Fonte de alimentação V
  3. S11-S12, S21-S22: Dual-channel safety devices (normally closed signal)
  4. S33-S34: Reset terminals (connect external normally open reset button; shorted = automatic reset)
  5. 13-14 / 23-24 / 33-34: Safety outputs (for controlling main contactors)
  6. 41-42: Normally closed fault feedback signal
  7. Model Correction & Referência Alternativa

⚠️ The most frequently confused model on the market: SNA4043K-A (4043, easily mistaken for 4053)

⚠️ Important Verification Conclusion

SNA4053K-A is NOT an official standard model in Wieland catalogues, it is highly likely a transcription error:

  1. Most common miswriting: SNA4043K-A (Número da peça. R1.188.1810.0)

Reinicialização automática, no reset monitoring; dual-channel with short-circuit monitoring

  1. Alternative similar model: SNA4063K-A

Reinicialização manual (with reset monitoring) — this is the core difference from SNA4043

Model rules:

SNA4043K-A: Reinicialização automática

SNA4063K-A: Reinicialização manual (reset button monitoring)

Both models share identical contact configuration, safety rating and dimensions; only reset logic differs.

Quick Selection Comparison Table

ModeloManufacturer Part No.Tensão de alimentaçãoModo de reinicializaçãoTipo de terminal
SNA4043K‑AR1.188.1810.0CA/CC 24 VReinicialização automáticaPluggable screw K
SNA4063K‑AR1.188.1870.0CA/CC 24 VReinicialização manual (with reset monitoring)Pluggable screw K

Recommended Actions

  1. Verify the printed model on the physical nameplate of the unit;
  2. Confirm site requirements: Reset monitoring required or not

Emergency stop circuits generally require manual reset (SNA4063K-A)

Safety light curtain applications may adopt automatic reset (SNA4043K-A)

Application Scenarios of Wieland SNA Series Relés de segurança (SNA4043 / SNA4063)

This series achieves PL e / Cat.4 / SIL3 with dual-channel monitoring, primarily deployed for safety circuits on machine tools and automated production lines. Content is divided into supported safety signal types, industry applications, and key selection differentiation.

  1. Supported Safety Input Signals (Hardware Utilization)
  2. Botões de parada de emergência (dual normally closed contacts)

Most common application: Machine main emergency stop and zone emergency stop circuits.

Standard requirement: Emergency stop circuits prefer SNA4063K-A (manual reset with monitoring).

  1. Safety gate switches / Magnetic safety sensors

Interlock for protective doors, maintenance doors and perimeter fencing; power circuit cutout upon door opening.

  1. Safety light curtains

Hazard zone intrusion protection for presses, conveyor lines and robot stations.

Light curtain solutions commonly use SNA4043K-A (reinicialização automática).

  1. Two-hand control devices

For stamping and riveting equipment, preventing single-hand access to hazardous zones.

  1. Safety mats, safety bumpers

Perimeter intrusion detection around robot cells, automatic doors and lifting platforms.

  1. Major Industry & Equipment Applications

(1) Indústria de máquinas-ferramenta

Tornos CNC, machining centres, moedores, punching machines, máquinas de dobra

Aplicativo: Protective door interlock, circuitos de parada de emergência, safety light curtain protection

(2) Automated Production & Equipamento de embalagem

Máquinas de embalagem, palletizers, linhas transportadoras, sorting equipment, labellers

Robot workstations, gantry robot safety fence interlock

(3) Borracha & Indústria de Plásticos

Injection moulding machines, extrusoras, blow moulding equipment: Safety gates, parada de emergência, cortinas de luz de segurança

(4) Logística & Warehousing Equipment

Automated warehouses, lifts, shuttles, sorting lines

Lifting platforms, dock leveller safety interlocks

(5) Nova Energia & Equipamento de bateria de lítio

Cell assembly machines, electrolyte filling machines, sealing equipment, test tooling

Wieland products are widely adopted on export machinery to meet EU CE Machinery Directive requirements

(6) Carpintaria & Máquinas de impressão

Panel saws, máquinas de corte, printing presses, die-cutting machine safety protection

(7) General Custom Automation

Custom test fixtures and assembly machines; deployed as core safety logic unit to cut off main contactors and servo power circuits.

  1. Critical Application Selection Comparison
ModeloModo de reinicializaçãoAplicação Típica
SNA4043K‑AReinicialização automáticaSafety light curtains, safety bumpers; system enables restart automatically after obstacle removal
SNA4063K‑AReinicialização manual (with reset monitoring)Botões de parada de emergência, safety gate switches. Manual reset operation is mandatory before machine restart (required by machinery safety standards)

⚠️ SNA-4053-K-A is not an official Wieland standard model. It is almost certainly a nameplate transcription error; physical unit will be one of the two above variants.

  1. Limitações & Aplicativos inadequados
  2. Cannot directly drive high-power loads; safety contacts are intended to control contactor coils, not motors directly
  3. Not suitable for solenoid valves or high-frequency switching loads
  4. Cannot satisfy safety requirements higher than PL e / Cat.4 (this series already reaches Cat.4 maximum rating)

Selection Guidelines for Wieland SNA / SNO Safety Relays

Based on the SNA4043 / SNA4063 platform covered above; structured criteria ready for engineering proposals and procurement checks.

Etapa 1: Confirm Required Safety Rating (Mandatory Priority)

Compatível com ISO 13849-1 / EM 62061

  1. PL & Categoria

PL e / Cat.4: Highest rating. For high-risk stations including robots, stamping, injection moulding, machine tools and lithium battery equipment (supported by all mainstream SNA variants)

PL-d / Cat.3: Low-risk general automation and conveyor lines

  1. SIL Level

SIL 3 corresponds to PL e; preferred for machinery exported to EU

✅ Selection Rule: Do NOT downgrade safety rating for high-risk equipment.

Etapa 2: Determine Safety Input Channel Configuration (Dual Channel Is Standard)

Channel Modes

Dual-channel monitoring with cross short-circuit detection: Industry standard, fitted across all SNA variants. Compatible with dual normally closed safety devices (Parada de emergência, safety gates, cortinas de luz)

Single channel: Only permitted for low-risk scenarios; available on selected SNO variants. NOT allowed for high-risk machinery.

Compatible Sensor Types

Emergency stop switches, mechanical safety gates: Dual normally closed (NC)

Magnetic safety switches, cortinas de luz de segurança: NC duplo / OSSD signals

⚠️ Two types of safety light curtains:

① OSSD solid-state output → Requires relay model supporting OSSD input

② Light curtain with relay converted contact output → Compatible with standard SNA4043 / SNA4063

Etapa 3: Modo de reinicialização (Most Common Source of Wrong Selection!)

Reset TypeExemplo de modeloAplicativoCompliance Note
Reinicialização automáticaSNA4043K‑ASafety light curtains, safety bumpers, safety mats; system ready after obstacle clearedFORBIDDEN for emergency stop and safety gate circuits
Redefinição manual (with reset line monitoring)SNA4063K‑ABotões de parada de emergência, machine protective safety gates; manual reset push required before restartMandatory recommendation per machinery safety standards; preferred for most complete machinery

Key Distinction:

Monitored reset detects open or short circuits on reset wiring and triggers safety lockout for superior safety. Simple unmonitored manual reset should be avoided on new projects.

Etapa 4: Tensão de alimentação

Main Wieland options:

Suffix A = AC/DC 24 V (Automation standard, selected in 90% of projects)

Less common: 110 VAC, 230 VAC — only for legacy retrofits

Exemplo: SNA4063K-A → A = AC/DC 24 Alimentação V

Etapa 5: Tipo de terminal (Identified by Suffix K / C)

K = Pluggable screw terminals

Vantagens: Vibration resistant, ideal for permanent cabinet installation and on-site maintenance (the unit in your photo uses K terminals)

C = Push-in spring terminals

Vantagens: Fast wiring without screwdrivers; use cautiously under heavy vibration

Exemplo: SNA4063K-A

Etapa 6: Output Contact Configuration

Main Safety Outputs (For Power Circuit Cutoff)

SNA4043 / SNA4063: 3 contatos de segurança normalmente abertos

Propósito: Wired in series with main contactor coils for redundant shutdown

Auxiliary Signal Contacts (PLC Feedback)

1 built-in normally closed fault contact

Opens upon safety activation or relay fault; used for alarm indicators and PLC signalling

Nota de seleção: If multiple feedback signals are required, add auxiliary relays. Safety contacts should not be expanded externally.

Contact Load Ratings

AC-15: 230 V / 5 UM

DC-13: 24 V / 5 UM

👉 Never drive motors directly; only control contactor coils!

Etapa 7: Montagem & Especificações Físicas

  1. Montagem: Standard DIN 35 trilho mm
  2. Largura: SNA40xx series 22.5 milímetros, compact design saving cabinet space
  3. Classificação ambiental: IP20 (apenas para instalação em gabinete; not for outdoor direct deployment)

Etapa 8: Differentiate SNA vs SNO Series (Frequent Confusion)

SNA Series: Dual-channel safety monitoring, up to PL e Cat.4; for emergency stop, safety gates, cortinas de luz (your target series)

SNO Series: Predominantly single channel, lower safety rating generally PL d and below; low-cost basic solutions

Common Selection Pitfalls Checklist

  1. ❌ Misapplication: Using automatic reset SNA4043 for emergency stop circuits — violates machinery safety standards, fails third-party audit & Certificação CE
  2. ❌ Transcription error SNA-4053-K-A: No official model; physical unit is either SNA4043 or SNA4063
  3. ❌ Direct drive of solenoid valves or high-power loads with safety contacts → contact burnout and loss of safety function
  4. ❌ Mixing K screw terminals and C spring terminals, leading to mismatch on delivery
  5. ❌ Ignoring reset monitoring requirements → machine fails acceptance testing

Rapid Selection Workflow (For Field Engineers)

  1. Identify safety device: Parada de emergência / safety gate → select SNA4063xx-A (monitored manual reset); Light curtain / safety bumper → SNA4043xx-A (reinicialização automática)
  2. Confirm supply voltage: Default AC/DC24V suffix A
  3. Select terminal type: Permanent cabinet installation → K screw terminal; high volume assembly for fast wiring → C spring terminal
  4. Verify safety rating: High-risk equipment requires PL e / Cat.4 / SIL3
  5. Confirm number of safety contacts sufficient for contactor control

Complete Official Model List of Wieland SNA40xx Safety Relays

Series Profile: safeRELAY SNA40xx dual-channel safety monitoring, PL e / Cat.4 / SIL3, Montagem em trilho DIN;

⚠️ Important Notice: SNA-4053-K-A is NOT an official Wieland model, it is a transcription error. Official core variants are limited to 4043 / 4044 / 4063 / 4064;

Industry standard: Suffix A = AC/DC24 V (automation default). Specify A suffix for new orders.

  1. Regras de nomenclatura de modelo

`SNA 40XX [terminal][Reiniciar]-[Voltage Suffix]`

  1. SNA: Dual-channel safety monitoring base unit
  2. 40XX:

4043: 3 safety NO contacts, reinicialização automática (no reset monitoring)

4044: 4 safety NO contacts, reinicialização automática (no reset monitoring)

4063: 3 safety NO contacts, reinicialização manual (with reset circuit monitoring)

4064: 4 safety NO contacts, reinicialização manual (with reset circuit monitoring)

Last digit 3 = 3 safety NO contacts; Last digit 4 = 4 safety NO contacts

  1. Terminal Code

K: Pluggable screw terminals (most widely used in projects)

C: Pluggable Push-in spring terminals

  1. Extended Reset Suffix (KM/KE)

km: Simple manual reset without monitoring; rarely specified for new projects

  1. Voltage Suffix

UM: CA/CC 24 V (automation standard)

Sem sufixo: Fixed screw terminals (legacy models, descontinuado)

  1. Mainstream Models for Domestic Projects (24 V CA/CC)

SNA4043 Series | Reinicialização automática, 3 Safety NO Contacts

Modelo CompletoWieland Part No.Tipo de terminalConfiguração de contatoModo de reinicializaçãoAplicação Típica
SNA4043K‑AR1.188.1810.0Pluggable screw K3 Safety NO + 1 NC Fault ContactReinicialização automática (no reset monitoring)Safety light curtains, safety bumpers, safety mats
SNA4043C‑AR1.188.1940.0Push‑in spring C3 Safety NO + 1 NC Fault ContactReinicialização automática (no reset monitoring)High volume cabinet fast wiring

SNA4044 Series | Reinicialização automática, 4 Safety NO Contacts

Modelo CompletoWieland Part No.Tipo de terminalConfiguração de contatoModo de reinicializaçãoAplicação Típica
SNA4044K‑AR1.188.1860.0Pluggable screw K4 Safety NO + 1 NC Fault ContactReinicialização automática (no reset monitoring)Applications requiring multiple safety cutout circuits, light curtain systems
SNA4044C‑AR1.188.1960.0Push‑in spring C4 Safety NO + 1 NC Fault ContactReinicialização automática (no reset monitoring)Synchronous cutout of multiple contactors

SNA4063 Series | Redefinição manual (Monitorado), 3 Safety NO Contacts【Preferred for Complete Machinery】

Modelo CompletoWieland Part No.Tipo de terminalConfiguração de contatoModo de reinicializaçãoAplicação Típica
SNA4063K‑AR1.188.1440.0Pluggable screw K3 Safety NO + 1 NC Fault ContactManual reset ✅ with reset monitoringBotões de parada de emergência, machine safety gates, CE certified machinery (Mais populares)
SNA4063C‑AR1.188.1950.0Push‑in spring C3 Safety NO + 1 NC Fault ContactManual reset ✅ with reset monitoringExport custom automation, fast cabinet wiring

SNA4064 Series | Redefinição manual (Monitorado), 4 Safety NO Contacts

Modelo CompletoWieland Part No.Tipo de terminalConfiguração de contatoModo de reinicializaçãoAplicação Típica
SNA4064K‑AR1.188.1880.0Pluggable screw K4 Safety NO + 1 NC Fault ContactManual reset ✅ with reset monitoringMulti‑group power circuit cutout, large machine tools
SNA4064C‑AR1.188.1970.0Push‑in spring C4 Safety NO + 1 NC Fault ContactManual reset ✅ with reset monitoringSystems requiring synchronous shutdown of multiple contactors
  1. Legacy Non-Standard Voltage Models (Only For Equipment Replacement, Not Recommended For New Projects)

Fixed non-pluggable screw terminals (no suffix A)

SNA4043K: AC42~48 V / AC115 V / AC230 V

SNA4063K: AC230 V

Observação: All new domestic machinery shall adopt AC/DC24 V models with suffix -A

  1. General Specifications Applicable to All Variants
  2. Classificação de segurança: PL e / Cat.4, SIL 3 (EN ISO13849-1, EN62061)
  3. Contact Ratings: AC-15 230 V/5 A; DC-13 24 V/5 A
  4. Montagem: DE 35 trilho mm; Largura 22.5 milímetros; IP20 (Cabinet installation only)
  5. Características: Dual-channel cross short-circuit monitoring, EDM external device monitoring support, 3 status LED indicators
  6. Fiação: Supports single-channel / dual-channel connection modes
  7. Quick Selection Summary Table
Model GroupModo de reinicializaçãoCompatible Safety DevicesCompliance Restriction
SNA4043 / SNA4044Reinicialização automáticaSafety light curtains, safety bumpers❌ NOT permitted for emergency stop and machine safety gate circuits
SNA4063 / SNA4064Redefinição manual (Monitorado)Emergency stop switches, safety gate switches✅ Compliant with EN60204 machinery safety standards, accepted for CE audits
  1. Procurement Reminders
  2. If customer submits model `SNA-4053-K-A` → Confirm transcription error immediately. Check physical nameplate; the actual unit is almost certainly SNA4063K-A.
  3. Always include complete model + manufacturer part number in BOM to avoid delivery mismatch between K screw terminals and C spring terminals.
  4. Do not interchange automatic reset SNA4043 and monitored manual reset SNA4063; incorrect selection will lead to failed safety acceptance.
  5. Contact count selection: 3 contactors or less → SNA4063; ≥4 contactors requiring synchronous shutdown → select SNA4064.

Anterior:

Deixe uma resposta

Deixe um recado