Siemens 6EP1437-2BA10 Industrial Power Supply

Siemens 6EP1437-2BA10 SITOP POWER 40 Three-Phase Industrial Power Supply

  1. Detalhamento do código do modelo

6EP1437-2BA10

6EP: Standard industrial power supply series of SITOP

1437: High-power three-phase AC model, 40A output platform

2: Basic standard version (without redundant diagnostic interface)

BA: Montagem em trilho DIN, 24Saída VCC

10: 3-phase 400–500V input, 40UM / 960W output specification

  1. Parâmetros elétricos principais

Lado de entrada (3-Phase Industrial Grid)

Input format: 3×400~500V AC, 3-phase 5-wire L1/L2/L3/PE

Freqüência: 50/60Hz

Voltage dip tolerance: Minimum 340V for 2 seconds without output collapse

Wire gauge for input terminals: 0.5~4mm² solid/stranded copper wire

Output Side (Standard Industrial 24VDC)

Rated output: 24CCV / 40UM, total power 960W

Adjustable output voltage range: 22.8~26.4V (tweaked via potentiometer at bottom)

Ondulação & barulho: Ripple <150mVpp, peak noise <240mVpp

Output terminals: Dual groups of +/terminals for parallel connection; wire gauge 0.5~10mm²

Parallel expansion: Two identical units can be directly paralleled for max. 80Uma saída

Funções de proteção (Full-condition Protection)

  1. Proteção contra curto-circuito: Automatic hiccup current limiting, auto-recovery after fault clearance
  2. Proteção contra sobretensão (OVP): Output cut-off when voltage >27V
  3. Proteção contra sobrecarga (OLP): Current limiting at 120% corrente nominal
  4. Over-temperature Protection (OTP): Shutdown on overheat, auto-restart after cooling down
  5. Protection against input phase loss, surge and industrial EMC interference

III. Mecânico & Especificações Ambientais

Montagem: Vertical installation on standard 35mm DIN rail

Dimensões gerais (L × A × P): 160 × 125 × 121 milímetros

Peso líquido: Aprox.. 2.0 kg

Classe de proteção: IP20 (for cabinet installation only)

Temperatura operacional: 0~+55°C (full power derating required above 55°C)

Armazenar / temperatura de transporte: -25℃~+85℃

Umidade: 5%~95%RH, sem condensação

Certificações: CE, UL, GL marine certification; compliant with EN61010, EN61000 industrial EMC standards

  1. Comparison Table of Same-Series 3-Phase Power Supplies
Número do pedido.Entrada24V OutputPoderPosicionamento
6EP1436-2BA103AC 400–500V20UM480CMedium-capacity 3-phase power supply
6EP1437-2BA103AC 400–500V40UM960CHigh-power standard 3-phase power supply
6EP1437-3BA003AC 400–500V40UM960CEquipped with relay signal output (fault contacts 13/14)
  1. Definição de terminal
  2. Input terminals: L1, L2, L3, Educação Física (3 fases + protective earth)
  3. Output terminals: Dual sets of +24V, 0V (parallel for current sharing)
  4. Voltage trimming potentiometer: Located at bottom; adjust with flat screwdriver
  5. Luz indicadora: Solid green = normal output; desligado / flashing = fault (perda de fase, curto-circuito, superaquecimento)
  6. Cenários típicos de aplicação
  7. Large PLC control cabinets (S7-1500/400, full-station power supply for ET200SP distributed I/O)
  8. Multi-axis servo systems, inverter control stations, estações de trabalho robóticas
  9. Embalagem, triagem logística, automotive welding & assembly production lines
  10. Tratamento de água, energia eólica, metalurgia, cement and other high-power industrial control equipment
  11. Centralized 24V power supply scenarios requiring 3-phase industrial incoming power and high current loads

VII. Substituição & Capacity Expansion Solutions

  1. Upgraded same-spec model: 6EP1437-3BA00 (with fault relay contacts for PLC diagnostic connection)
  2. Capacity expansion: Parallel two 6EP1437-2BA10 units for max. 80UM / 1920W output
  3. Downsized alternative: 6EP1436-2BA10 (20UM / 480C) for half-load applications

VIII. Installation Prohibitions & Guia de solução de problemas

Forbidden Operations (Critical Restrictions)

  1. Horizontal or upside-down mounting is strictly prohibited; blocked cooling air duct triggers rapid over-temperature protection
  2. Long-term power-on with direct output short circuit will cause continuous hiccup power derating
  3. Long-term operation with missing input phase accelerates aging of internal power components
  4. Do not install alongside high-power inverters without partition plates to avoid EMC interference

Common Fault Matrix

FenómenoCausa raizContramedidas
Green light off, no 24V output3-phase power loss, disjuntor desarmou, internal overheatingCheck 3-phase incoming voltage; power off and cool down then restart; clean dust in air duct
Green light flashing, output voltage dropOutput overload / curto-circuitoDisconnect loads and locate short circuit by segmentation; limit total load within 40A
Output voltage below 23V under loadUndersized cables causing excessive voltage dropThicken 24V main cables; add auxiliary power supplies nearby
Frequent over-temperature shutdownAmbient temp >55℃, clogged air duct, fully enclosed cabinetInstall cabinet cooling fan, lower ambient temperature, reserve ≥50mm top & bottom ventilation clearance

Official Overall Dimensions of Siemens 6EP1437-2BA10 (SITOP POWER 40 3-Phase 40A Power Supply)

  1. Overall Unit Dimensions (L × A × P, unidade: milímetros)

160 × 125 × 121 milímetros

Largura (horizontal along DIN rail): 160 milímetros

Altura (vertical cooling air flow direction): 125 milímetros

Profundidade (cabinet depth direction): 121 milímetros

Peso líquido: Aprox.. 2.0 kg

  1. Dimension Differentiation of Confusable Same-Series Models (Avoid Errors in Procurement & Cabinet Layout)
Número do pedido.EspecificaçãoL × A × P (milímetros)Peso
6EP1436-2BA103-phase 20A90 × 125 × 1201.6 kg
6EP1437-2BA103-phase 40A (without fault contacts)160 × 125 × 1212.0 kg
6EP1437-3BA003-phase 40A (with fault relay)160 × 125 × 1212.0 kg
6EP1437-2BA20 (New PSU300S Series)New generation 40A145 × 145 × 1503.1 kg
  1. Cabinet Installation Clearance Requirements
  2. Mounting rail: Standard 35mm TH35 DIN rail, instalação vertical (terminals downward)
  3. Principal & bottom ventilation clearance: Reserve at least 40mm for heat dissipation; derating mandatory if ambient temp exceeds 55℃
  4. Side-by-side mounting: Units of same model can be tightly arranged without extra spacing

Nota Suplementar

Dimensions such as 250×180×92 and 145×145×150 shown on some foreign websites belong to the new PSU300S model 6EP1437-2BA20, which is incompatible with the legacy 6EP1437-2BA10. Cabinet cutout and DIN rail layout cannot be shared between them.

Anterior:

Deixe uma resposta

Deixe um recado