Bently Nevada 3500/42M-A09-B00 Proximitor/Seismic Monitor (Dynamic Data Acquisition Module)
Marca: Bently Nevada (Baker Hughes), part of the 3500 Series TSI Machinery Protection System. Official Name: Proximitor/Seismic Monitor. Base Order Part Number: 143694-01. It is a 4-channel programmable card supporting both protection alarming and dynamic waveform acquisition, serving as the core monitoring card for steam turbine units.
- Codul modelului Explicația: 3500/42M-A09-B00
3500: 3500 TSI Machinery Protection System
/42M: 4-channel Proximitor/Seismic Monitor card. Sufixul “M” means dynamic waveform acquisition is supported. The legacy 3500/42 does not support dynamic data acquisition.
A09: Segment A = Sensor Input Option. 09 = Supports both Proximitor (Eddy Current) and Seismic sensors (velocity / accelerare).
B00: Segment B = Certification Option. 00 = Without CSA NRTL/C certification; B01 is the version with CSA certification.
Distinction Notes
A01: Eddy current input only; A02: Seismic sensor input only; A09 hybrid type can connect to 3300XL eddy current probes for shaft vibration / axial displacement measurement, and also piezoelectric velocity sensors for bearing housing vibration measurement.
3500/40M: Speed and keyphase only; 3500/45: Temperature card; 3500/42M is the primary monitoring card for vibration and displacement.
- Specificații tehnice de bază
| Articol | Caietul de sarcini |
| Numărul de canale | 4 independent channels. Channels are configured in pairs (1&2 as one group, 3&4 as another group). Each group can be set for one measurement type. |
| Sensor Input (A09) | Eddy current Proximitor (3300XL series) + Seismic sensors (velocity / accelerare) |
| Measurable Parameters | Radial shaft vibration, axial thrust displacement, differential expansion, eccentricity, REBAM, bearing housing velocity/acceleration, shaft absolute vibration, CAA (Circular Acceptance Area) |
| Signal Frequency Range | Eddy current: 10Hz~10kHz; Seismic:1Hz~10kHz |
| Static Measurement Accuracy | ±0,5% FS; Dynamic waveform acquisition for System1 spectrum analysis |
| Configurare alarmă | Alert warning available per channel; Each group supports 2 Danger trip setpoints to drive hardwired protection relays via 3500/33 card |
| Temperatura de operare | -30℃ ~ +65℃ (inside cabinet) |
| Consumul de energie | Max 10W, powered by rack backplane |
| Indicatori | Bine, TX/RX backplane communication LEDs, independent status LED for each of 4 canale |
| SIL | The complete system meets SIL2 (subject to full loop assessment); Compliant with API670 machinery protection standard |
| Instalare | Full-height card, fits any monitoring slot in 3500 rack; interschimbabil la cald (interlock must be removed before operation) |
III. Funcții de bază
- Paired channel configuration: Channels 1&2 can be configured for shaft vibration while channels 3&4 for bearing housing vibration. The same card can mix eddy current and seismic sensors.
- Static protection measurement: Calculate vibration amplitude and displacement values in real time, compare with setpoints to trigger Alert / Danger alarms, and send signals to 3500/33 relay card for hardwired unit trip protection.
- Dynamic waveform acquisition (core feature of M version): Capture raw vibration waveforms, 1X/2X amplitude and phase, upload to System1 for spectrum and orbit analysis to diagnose faults such as rotor unbalance, misalignment and rub.
- Sensor self-diagnosis: Detect probe open circuit, short circuit and excessive gap deviation; sensor faults are directly logged into rack event history.
- REBAM® Bearing Condition Monitoring: Bently patented algorithm to evaluate bearing oil film stability.
- Event logging: Alarms and sensor faults are recorded with timestamps, which can be uploaded to DCS through 3500/92 communication gateway card.
- Scenarii tipice de aplicare
Steam turbines, centrifugal compressors, axial fans, motoare mari; TSI systems in thermal power, coal chemical and oil & gas refining industries.
Eddy current channels: Rotor radial vibration, axial displacement, differential expansion
Seismic channels: Bearing housing casing vibration (velocity / accelerare)
- Instalare & Configuration Guidelines
- Cablaj: Eddy current probe extension cable + proximitor. Cable length must be matched (3300XL system uses fixed-length cables, must not be arbitrarily cut). Seismic sensor shielded cable with single-point grounding.
- Configuration Procedure
Connect rack via Rack Configuration software and add 3500/42M card.
Channel grouping: Set channel1/2 to eddy current radial vibration; channel3/4 to seismic velocity.
Set sensor sensitivity, measurement range, Alert warning value and Danger trip setpoint.
Enable dynamic acquisition and configure waveform sampling parameters.
Download configuration to rack; confirm channel OK LED steady on, perform probe gap verification and simulate alarms to test relay operation.
- Punerea în funcțiune: Verify eddy current probe gap voltage (around -10V DC); calibrate seismic sensor sensitivity.
- Common Troubleshooting Checklist
- OK LED flashing: Lipsă / invalid card configuration, re-download rack configuration.
- Channel reports sensor fault: Abnormal proximitor power supply, open/short circuit of cable, worn probe or out-of-range gap; check gap voltage output from proximitor.
- Fluctuating vibration readings: Multi-point grounding of proximitor shield, cable routed near power cables causing interference; loose probe mounting.
- Normal static value but no dynamic waveform in System1: Dynamic acquisition not enabled in configuration, or missing 3500/22M transient interface module.
- Danger alarm fails to trigger relay: Verify alarm voting logic and configuration mapping between 3500/33 relay card.
VII. Comparație de serie & Selectarea modelului
| Model | Tip de intrare | Dynamic Acquisition | Certificare |
| 3500/42M-A09-B00 | Hybrid Eddy Current + Seismic | Sprijinit | No CSA |
| 3500/42M-A09-B01 | Hybrid Eddy Current + Seismic | Sprijinit | With CSA |
| 3500/42M-A01-B00 | Eddy Current Only | Sprijinit | No CSA |
| 3500/42-A01-B00 | Eddy Current Only | No dynamic acquisition | No CSA (moştenire, eliminat treptat) |
Metrix ST5484E-123-434-22 Seismic Velocity Vibration Transmitter
Marca: Metrix (STATELE UNITE ALE AMERICII). ST5484E is an integrated 2-wire loop-powered velocity vibration transmitter. It adopts built-in piezoelectric accelerometer core, integrating circuit and true RMS processing, directly outputs 4–20mA signal for bearing housing casing vibration monitoring. Different from Bently eddy current probes which measure shaft vibration.
- Codul modelului Explicația: ST5484E-123-434-22
Model format: ST5484E AAA BBCC EF
123: Range code, 2.0 in/s (50.8 mm/s RMS), 4mA=0; 20mA=full scale 50.8mm/s
434: Filtra, mounting thread, housing material
4: Filter option
3: Mounting thread 1/4-28 UNF stud mounting
4: 316 carcasa din otel inoxidabil
22: Conexiune electrică + explosion-proof certification
2: 2-terminal block wiring
2: Ex ia IIC T4 intrinsically safe version
Distinction Notes
ST5484E: Casing vibration velocity transmitter; ST5491E with local display; SW5484E with built-in relay vibration switch.
- Specificații tehnice de bază
| Articol | Caietul de sarcini |
| Principiul de măsurare | Piezoelectric acceleration + integrare, outputs vibration velocity RMS value |
| Interval de măsurare | 0~2.0 in/s (0~50.8 mm/s RMS) |
| Semnal de ieșire | 2-wire 4–20mA, loop powered; Metrix patented IPT non-polar wiring |
| Tensiune de alimentare | 11~29.6 VDC (24VDC recommended) |
| Raspuns in frecventa | 2Hz ~ 1kHz, suitable for casing vibration monitoring of pumps, fani, motors and compressors |
| Materialul carcasei | 316 oţel inoxidabil |
| Instalare | 1/4-28 UNF stud, directly fastened onto bearing housing surface |
| Explosion-proof Rating | ATEX/IECEx Ex ia IIC T4 Ga (intrinsec sigur, safety barrier required) |
| Protecție la intrare | IP67 |
| Temperatura de operare | -40℃ ~ +85℃ |
| Izolare | 500Vrms isolation between loop and housing |
| Greutate | Aproximativ. 170g |
| Caracteristici | Factory calibrated, no zero/range potentiometer for field adjustment; 4-wire version optional with raw acceleration dynamic output |
III. Funcții de bază
- Integrated RMS processing: Built-in integration and true RMS circuit, directly output 4-20mA proportional to vibration velocity. Can be connected to DCS/PLC directly without extra proximitor.
- IPT non-polar loop: Wiring without positive/negative polarity distinction to reduce field wiring errors.
- Intrinsically safe explosion protection: Zonă 0 intrinsec sigur, applicable for hazardous areas in chemical and petrochemical industries.
- Optional narrowband filter to suppress high-frequency interference, fit for rolling bearing equipment monitoring.
- Single-direction measurement: Measures along sensor axial direction; align monitoring direction (horizontal / vertical) during installation.
- Scenarii tipice de aplicare
Bearing housing casing vibration monitoring for centrifugal pumps, fani, motoare, gearboxes and small compressors; petrochimic, coal chemical and power plants.
>Comparison with Bently 3500/42M: ST5484E outputs standard 4-20mA to DCS and cannot provide raw dynamic waveform for spectrum analysis. Bently 42M can capture raw waveforms for fault diagnosis.
- Instalare & Ghid de punere în funcțiune
- Instalare: Stud must be tightened on flat metal surface of bearing housing, polish and remove rust on contact surface. Sensor axial direction must align with measured vibration direction. Avoid installation on thin wall or stiffener (resonance interference).
- Cablaj: 2-wire intrinsically safe loop, intrinsically safe safety barrier is mandatory. Shielded cable single-point grounding; do not route together with power cables in the same cable tray.
- Loop calculation: Maximum allowable loop resistance depends on supply voltage. Max loop resistance ≈650Ω under 24VDC supply.
- Calibrare: Full-unit calibration on vibration shaker table. No zero or span adjustment knobs inside sensor; range cannot be modified on site.
- Configurare: Set in DCS: 4mA=0 mm/s, 20mA=50.8 mm/s, configure high vibration alarm and high-high interlock setpoints.
- Common Troubleshooting Checklist
- Fixed 4mA output: Broken loop, faulty safety barrier, loss of sensor power supply; damaged internal sensing element.
- Fixed 20mA output: Short circuit in loop, damaged internal circuit of sensor, vibration exceeds full scale.
- Fluctuating readings: Loose mounting, resonance on contact surface; multi-point grounding of shield; cable interference from inverter power lines.
- Low vibration readings: Wrong installation direction; paint/gasket on contact surface leading to weakened vibration transmission.
VII. Comparație de serie & Selectarea modelului
| Model | Gamă | Cablaj | Rezistent la explozie | Dynamic Output |
| ST5484E-123-434-22 | 50.8mm/s RMS | 2-core terminal | Intrinsically safe Ex ia | Nu (4-20mA only) |
| ST5484E-124 | 125mm/s | Sârmă de plumb | Opțional | Nu |
| ST5484E 4-wire version | On demand | 4-miez | Opțional | With raw acceleration dynamic signal |
| ST5491E | Same as ST5484E | Opțional | Opțional | With local digital display |
Contactor,întrerupător de circuit,senzor,Codificator,PLC,Convertor