Comanda nr.: 6ES7193-6AR00-0AA0
Desemnare: SIMATIC ET200SP Bus Adapter BA 2×RJ45
Descriere: Dedicated bus adapter for ET200SP IM155-6 PN interface module, equipped with 2-channel RJ45 PROFINET ports.
⚠️ Common Misconception: It is NOT a BaseUnit. BaseUnits share the same 6ES7193 prefix but carry 6BPxx type codes. This unit is a communication bus adapter, plugged onto the rear of the IM155-6 interface module.
Defalcarea codului de model
6ES7: SIMATIC S7 automation product
193: ET200SP accessories (bus adapters / base units)
6: ET200SP platform
AR00: BA 2×RJ45 dual RJ45 bus adapter
0AA0: Versiune standard & ambalaj
Specificații tehnice cheie
| Articol | Parametru |
| Interfețe | 2 × RJ45 (PROFINET) |
| Communication Speed | 10/100 Mbps, PROFINET RT / IRT |
| Cable Type | Industrial CAT5e cable; max. 100 m per segment |
| Supported Topologies | Line topology, MRP media redundant ring |
| Dimensiuni | W 20 mm × H 69.5 mm × D 59 mm |
| Greutate | ≈ 46 g |
| Clasa de protectie | IP20 (numai pentru instalarea dulapului) |
| Temperatura de operare (Montaj orizontal) | -30 ℃ ~ +60 ℃ |
| Temperatura de operare (Vertical Mount) | -30 ℃ ~ +50 ℃ |
| Max. Altitudine de instalare | 5000 m (derating cerut mai sus 2000 m) |
| Origine | Germania |
Compatible Interface Modules
Fits all IM 155-6 PN series interface modules:
6ES7155-6AU01-0BN0 IM155-6 PN ST
6ES7155-6AU00-0DN0 IM155-6 PN HS
6ES7155-6AA01-0BN0 IM155-6 PN HF
Aplicații tipice
- Line Daisy-Chain Connection: Port 1 receives signal from PLC, Port 2 cascades to the next ET200SP station.
- PROFINET MRP Ring Network: Form closed redundant ring with dual-port devices at both ends.
- Comparison with alternative ET200SP bus adapters
| Comanda nr. | Tip de interfață | Aplicație |
| 6ES7193-6AR00-0AA0 | 2×RJ45 | Widely used for cascading & ring topology |
| 6ES7193-6AF00-0AA0 | 1×RJ45 | Single port for end stations without further cascading |
| 6ES7193-6AP00-0AA0 | 2×FC quick connect | For PROFINET FC field cables |
| 6ES7193-6AG00-0AA0 | 2×LC fiber optic | Long-distance fiber communication |
Selecţie & Ghid de instalare
- IM155-6 PN module must be fitted with a bus adapter; the bare module cannot accept network cables directly.
- MRP redundant ring requires 6AR00 dual RJ45 version. Single-port 6AF00 cannot support ring topology.
- It is recommended to use Siemens industrial green PROFINET cables and industrial shielded RJ45 plugs.
- The module shall only be mounted on DIN35 rail inside control cabinets; outdoor installation is prohibited.
Common Troubleshooting Tips
Intermittent communication: Check shielding grounding of RJ45 connectors and ensure all 8 cable cores are terminated.
Failure to establish MRP ring: Confirm MRP is activated in TIA Portal and all ring nodes use dual-port bus adapters.
Memento de distincție: 6ES7193-6BPxx = IO module base unit, cannot be used for network connection.
Application Scenarios for 6ES7193-6AR00-0AA0 (BA 2×RJ45)
Caracteristica de bază: Dual RJ45 bus adapter dedicated to ET200SP IM155-6 PN with integrated two-port switch. Supports PROFINET daisy-chain wiring and MRP redundant ring, eliminating extra external switches and enabling multiple remote IO stations deployed sequentially along one cable route.
> Referinţă: Single-port 6AF00 is adopted for isolated end stations; 6AR00 is selected when cascading or ring redundancy is required.
- Scenarios Classified by Network Topology (Most Widely Used in Engineering)
(1) Daisy-Chain Topology (Highest Consumption)
✅ Suitable Conditions: Equipment arranged linearly along production lines, buget limitat, no network redundancy requirement
Layout: PLC switch → ET200SP (Port1 IN, Port2 OUT) → next ET200SP → …
Avantaje: Greatly reduce cable routing between control cabinets; no additional industrial switches needed.
Dezavantaje: All downstream stations will go offline if the middle link is broken.
Typical Sites:
Linii de ambalare, linii de transport, linii de role, linii de sortare
Linked machine tool production lines, utilaje pentru prelucrarea lemnului, plastic extrusion lines
Distributed IO along AGV guide tracks
Multi-cabinet connection for medium & small complete machines (main cabinet → multiple workstation sub-cabinets)
(2) MRP Media Redundant Ring (Preferred for High-Reliability Applications)
✅ Suitable Conditions: Unplanned production shutdown is unacceptable; automatic recovery upon single cable breakage
Layout: All ET200SP stations form a closed loop, MRP enabled in TIA Portal. Communication path switches automatically if one cable fails to maintain continuous production.
Typical Sites:
Sudare auto, coating and final assembly conveyor lines
Depozite automatizate, stacker crane logistics systems
Continuous production lines in food & pharmaceutical industries
Stații de epurare, pump station group process control
(3) Hybrid Topology (Daisy-Chain + Star)
ET200SP stations along each production line are connected in daisy chain, and the terminal of each line is connected to the central switch. Balances convenient wiring and centralized management.
- Industry-Specific Application Cases
🔹 Automotive Manufacturing (Aplicația cea mai comună)
- Welding workshop: Distributed signal collection for body fixtures, welding guns and sensors; linear daisy-chain layout on long conveyors; MRP rings deployed at critical sections.
- Coating lines: Remote IO deployed along electrophoresis, drying and conveyor chains.
- Final assembly lines: IO for tightening tools, stoppers and photoelectric sensors arranged along assembly lines.
🔹 Logistics & Automatizarea depozitelor
Automated stereoscopic warehouses, sorting conveyors, sortare cu centuri încrucișate
Mass distributed workstation IO arranged along roller conveyors; MRP rings adopted on key logistics trunk lines to avoid full sorting line shutdown caused by cable faults.
🔹 Packaging, Cauciuc & Plastic, Mașini de imprimat (Mainstream for OEM Machine Builders)
Multi-unit complete equipment: Extrudere, film blowing lines, filling lines, linii de ambalare din carton
Equipment consists of main cabinet plus several independent workstation sub-cabinets connected via daisy chain to save wiring.
> OEM Selection Tip: Use 6AR00 for cascading multiple ET200SP inside one machine; adopt 6AF00 for the last end station to cut costs.
🔹 Food & Industria farmaceutică
Continuous processes including filling, sterilization and packaging; distributed control cabinets in clean areas.
MRP ring topology is generally recommended for continuous production to avoid material scrapping caused by network failures.
🔹 Water Treatment, Municipal Pump Stations & Environmental Projects
Aeration tanks, valve wells and chemical dosing systems in wastewater plants; pump stations distributed along pipelines.
Daisy-chain network for long-distance distributed IO; MRP redundancy enabled for critical processes.
🔹 Machine Tools & Prelucrarea metalelor
Flexible production lines, roboți portal, linked machine tools; peripheral IO for clamping, cooling and loading/unloading signal acquisition.
🔹 New Energy Industry
Battery PACK production lines, PV module assembly lines with massive distributed workstation IO.
- Ghid de selecție: When to Choose 6AR00 / Alternative
✅ Prefer 6ES7193-6AR00-0AA0
- ≥2 ET200SP stations on one link requiring cascading
- PROFINET MRP redundant ring to be implemented
- Spațiu limitat pentru cabinet; no room for additional SCALANCE switches
- Production lines arranged linearly with remote IO placed sequentially along conveyors
❌ Nerecomandat (Choose 6ES7193-6AF00 Single RJ45 Instead)
- The ET200SP is the last end station without further cascading
- All stations connect to the switch via independent star cables, no daisy-chain layout
- On-Site Installation Precautions
- IP20 rating for indoor cabinet use only; fully enclosed protective cabinets are mandatory for outdoor or humid environments.
- MRP ring requirement: All nodes in the ring must use dual-port 6AR00; single-port 6AF00 cannot be mixed in the ring.
- Limit cascading quantity to ≤8~10 stations per daisy-chain link to avoid excessive communication latency.
- For transmission distance over 100 m or heavy electromagnetic interference, switch to fiber adapter 6ES7193-6AG00-0AA0.