Cod de comandă: 3AUA0000058188
Starea ciclului de viață: Învechit (Classic Maintenance Phase). Spare parts available, long lead-time for new stock; upgrade to ACS380 series is recommended.
- Type Code Decoding
ACS355-03E-07A3-4
| Domeniu | Descriere |
| ACS355 | ABB Machinery Conduce Serie |
| 3 | Three‑phase AC power supply input |
| E | Built‑in 50Hz EMC RFI filter |
| 07A3 | Continuous rated output current 7.3 O |
| 4 | Clasa de tensiune: 380‑480 VAC three‑phase |
- Core electrică & Specificatii mecanice
| Articol | Parametru |
| Typical motor power rating | 3.0 kW (400 V three‑phase) |
| Rated output current I₂N | 7.3 O |
| Input power supply | Three‑phase 380‑480 V ±10%, 48-63Hz |
| Protecție la intrare | IP20 (cabinet‑mount installation) |
| Dimensiunea cadrului | R1 |
| Frecvența de ieșire | 0‑600 Hz, vector / control V/F |
| Capacitate de supraîncărcare | 150% I₂N for 1 min per every 10 min; 180% I₂N peak for 2 s at start‑up |
| Frecvența de comutare | 4 kHz (implicit); adjustable from 4 kHz to 16 kHz |
| Built‑in functions | STO Safe Torque‑Off, integrated brake chopper, 8‑step sequence programming, FlashDrop fast parameter download |
| Dimensiuni de gabarit (L×A×D) | 70 mm × 239 mm ×161 mm |
| Greutate netă | 1.8 kg |
| Standard delivery scope | Control panel NOT included; panel must be ordered separately |
- Hardware Interface & I/O nativ
- Intrări digitale: 6 DIN; Ieșire digitală: 1 DO; Ieșire releu:1 Releu
- Intrări analogice:2 AI; Ieșire analogică:1 LA
- Native RS-485 (Modbus RTU); supports plug-in fieldbus option modules
- Dual-channel hardware STO safety terminals (compliant with machinery safety standards)
- Power terminals: L1/L2/L3 power input; U/V/W motor output; BR+ BR-brake resistor terminals; PE protective earth
⚠️ Brake resistor NOT supplied as standard; brake resistor is an external optional accessory.
- Lista de ambalare
✅ Items included in standard package:
- 1 × ACS355-03E-07A3-4 main unit
- I/O control terminal blocks, power terminals, mounting screw kit
- Paper-format installation manual & quick-start guide
- Paper mounting cutout template
❌ NOT included in standard delivery; trebuie comandat separat:
Control panels: ACS-CP-A (Advanced panel J400), ACS-CP-C (Basic panel J404)
Fieldbus modules: FPBA-01 (Profibus-DP), FENA-01 (EtherNet/IP / PROFINET), FMBA-01 (Modbus RTU), etc.
I/O expansion module MREL-01; encoder interface module MTAC-01
External brake resistor, panel extension cable, FlashDrop tool
- Compatible Replacement & Soluții de upgrade
Original model is obsolete; two selection scenarios below:
Opţiune 1: Upgrade to ABB ACS380-04-09A5-4 (3 kW,9.5 O)
Avantaje: New-generation machinery drive, funcții îmbunătățite, hardware STO supported, parameter migration tool available
⚠️ Notice: Terminal layout and cabinet mounting cutouts are NOT fully compatible. Cabinet modification is required. I/O definitions differ. Direct plug-and-play replacement is impossible. Rewiring, parameter conversion and commissioning are mandatory.
Opţiune 2: Spare-part stock of original ACS355-03E-07A3-4
Avantaje: Montaj identic, wiring and parameters; direct drop-in replacement
Dezavantaje: Limited stock, high unit price, long lead-time; classified as obsolete legacy spare-part stock.
- Scenarii tipice de aplicare
OEM machinery supporting: transportoare, utilaje de ambalare, textile equipment, woodworking machines, food-beverage processing equipment, small-size pumps & fani, simple lifting mechanisms and general-purpose variable-speed applications.
- Note de selecție & Application Boundary Conditions
- Temperatura mediului ambiant: Full-rating operation from 0 °C to +40 °C; derating required above 40 °C. Condensation, corrosive gas and heavy dust are prohibited. IP20 rating permits cabinet-only installation; direct field exposure is forbidden.
- This unit is factory-fitted with EMC filter. If input line reactor is added, ensure proper filter earthing.
- For heavy-duty cycles with frequent shock loading, select according to actual motor operating current instead of nominal power rating. If actual motor current exceeds 7.3 A, select the next higher drive frame size.
- Brake chopper is built-in; brake resistor must be externally fitted. Select brake resistor strictly per manual specifications. Never short-circuit BR terminals.
- For valid STO safety function in production operation, both STO channels shall be wired; single-channel short-circuit is prohibited.
- Important Maintenance Guidelines
Service life of R1-frame cooling fan: aproximativ. 3 years; fan replacement is recommended upon expiry.
Retorque power terminals every 6 years.
Annual functional verification test for STO safety function is recommended.
Application Fields of ABB ACS355-03E-07A3-4 (3 kW) Frecvenţă Converter
This is a compact OEM-oriented vector drive with IP20 cabinet-mount rating. It comes with built-in STO Safe Torque-Off, integrated EMC filter and built-in brake chopper. It targets general-purpose variable-speed control for small-to-medium-power stand-alone OEM machinery, and is not intended for heavy-duty continuous high-power drive cycles.
- Ambalare & Material-Handling Industry
Transportoare cu bandă, transportoare cu role, transportoare cu lanț, echipamente de sortare
Wrapping machines, case sealers, strapping machines, auxiliary palletizing mechanisms
Caracteristici: Frequent start-stop cycles, smooth speed regulation; STO safety function supports machine safety protection.
- Utilaje pentru prelucrarea lemnului
Wood cutting machines, șlefuitoare, multi-axis milling machines, saws
Material feed mechanisms for wood processing
Puncte forte: 0-600 Hz high-frequency output for high-speed spindles; on-board 8-step sequence programming reduces external PLC hardware requirement.
- Utilaje textile
Small-scale spinning & weaving auxiliary feeders, winding machines, sizing-machine auxiliary drives
Requirements: Cuplu stabil la viteză mică, tension-control capability; suitable for light-to-medium-duty winding tasks.
- Mâncare & Beverage Processing Equipment
Small mixing-tank drives, conveyor chains, filling-lines, labellers, mașini de sortat
Nota: The drive must be installed inside electrical cabinets. Direct exposure to wash-down / humid environments is not allowed; proper cabinet environmental protection is required.
- Pompe & Fani (HVAC & Tratarea apei)
Process circulation pumps, water-supply pumps, small centrifugal fans, ventilatoare de evacuare
Remarcă: Pumps and fans belong to quadratic-torque loads. This drive is applicable; cu toate acestea, dedicated fan-pump drives are preferred for large-capacity energy-saving projects.
- Materiale plastice & Rubber Machinery Auxiliary Equipment
Feeder units, benzi transportoare, small extruder auxiliaries, take-up & pay-off mechanisms
⚠️ NOT recommended for main injection-molding pump drives: Severe shock-loading exceeds the drive’s overload margin.
- Manipularea materialelor & Light Lifting Equipment
Light-duty elevators, auxiliary travelling mechanisms for small hoists, small lifting platforms
❗Critical boundary condition: For lifting applications, external brake resistor must be fitted and brake chopper enabled. Operation without brake resistor for lowering loads is strictly forbidden.
- General-Purpose Machine-Tools & Small Processing Equipment
Small grinders, feed drives, small spindle drives.
❌ Non-applicable Conditions (Capcanele de selecție)
- Outdoor direct installation (IP20; cabinet-mount only).
- Direct exposure to corrosive atmosphere, heavy conductive dust, condensation or moisture.
- Heavy-shock high-duty-cycle main drives (de ex. main injection-molding pumps, large winches).
- Field wall-mount installation requiring IP54 / IP65 high-protection rating.
Unit Application Matching Key Points
ACS355-03E-07A3-4 (3 kW /7.3 A) is intended for continuous rated load ≤3 kW motors. 150% overload for 1 min is specified for standard OEM machinery. For applications with frequent shock overload, select one power frame higher.
Full Detailed Parameters of ABB ACS355-03E-07A3-4
Cod de comandă: 3AUA0000058188; Frame size R1; Învechit, spare-part maintenance supply only.
- Type-code Explanation
| Segment de cod | Sens |
| ACS355 | ABB OEM Machinery Drive Series |
| 3 | Three‑phase AC power input |
| E | Built‑in C3‑class EMC RFI filter |
| 07A3 | Continuous output rated current 7.3 A |
| 4 | Voltage rating: 380‑480 V three‑phase |
- Main Electrical Ratings
| Articol | Valoare |
| Typical asynchronous motor power | 3.0 kW @400 V three‑phase |
| Rated output current I₂N | 7.3 O |
| Tensiune de intrare | Three‑phase 380‑480 VAC ±10% |
| Input frequency | 48-63Hz |
| Tensiune de ieșire | 0 ~ supply voltage (trifazat) |
| Gama de frecvență de ieșire | 0‑600 Hz (control vectorial fără senzori) |
| Capacitate de supraîncărcare | 150% I₂N for 1 min per every 10 min; 180% I₂N peak for 2 s on start‑up |
| Frecvența de comutare | Default 4 kHz; optional 4/8/12/16 kHz; derating required at high switching frequencies |
| Control modes | Scalar V/F, vector fără senzori; supports asynchronous & permanent‑magnet motors |
| Built‑in brake chopper ✅ | Standard; brake resistor is external |
| STO Safe Torque‑Off ✅ | Dual‑channel hardware; SIL3 / PL e (ISO 13849‑1) certificat |
| Drive efficiency | Approx.97% under rated load |
| DC bus voltage | 540 Vdc ±15% |
- Specificații terminale I/O
Native I/O fitted; no mandatory expansion card required. Control panel is optional, not factory-supplied.
| Tip de semnal | Cantitate & Caietul de sarcini |
| Intrare digitală DI | 6 canale; Compatibil PNP/NPN; 12‑24 VDC; impedance 2.4 kΩ; pulse‑input capable:0‑16 kHz |
| Digital Output DO | 1 channel transistor output; max 30 VDC,100 mA, short‑circuit protected; max pulse‑output frequency 16 kHz |
| Relay Output REL | 1 canal; contact rating max 250 VAC 5 A;30 VDC 0.5 A; AC/DC compatible relay contact |
| Analog Input AI | 2 canale; configurable ‑10~+10 V voltage /‑20~20 mA current; AI1 impedance >312 kΩ (modul de tensiune),100 Oh (modul curent) |
| Analog Output AO | 1 canal;0‑20 mA, max driving load 500 Ω |
| Auxiliary 24 V output | 24 VDC ±10%, max 200 mA; for DI & external sensor power supply |
| On‑board communication | Embedded EFB Modbus‑RTU (RS485); compatible with FPBA‑01, FENA‑01 and other fieldbus option modules |
| Safety terminals | X1C dual‑channel STO hardware safety terminals |
- Mecanic & Outline Data
| Articol | R1 Frame ACS355‑03E‑07A3‑4 |
| Protecție la intrare | IP20 (cabinet‑internal installation); NEMA Open |
| Montare | Montare pe șină DIN / screw‑fixed panel mounting |
| Overall W×H×D | 70 mm ×239 mm ×161 mm (including mounting clips) |
| Greutate netă | 1.8 kg |
| Package dimensions | 220 mm ×130 mm ×350 mm; single‑unit carton |
| Răcire | Integrated axial cooling fan; typical fan service life ~3 years |
- Condiții de mediu
| Articol | Caietul de sarcini |
| Temperatura ambiantă de funcționare | 0 … +40 °C full rating; derating above 40 °C; maximum permissible 50 °C (deratat); icing and condensation prohibited |
| Temperatura de depozitare | ‑40 … +70 °C |
| Altitudine | Full rating up to 1000 m above sea level; derate 1 % per additional 100 m above 1000 m; maximum operating altitude 2000 m |
| Gradul de poluare | Operation class 2C2; direct exposure to conductive dust or corrosive gas is forbidden |
| Vibrație | IEC 60068‑2‑6: 10‑57 Hz amplitude 0.25 mm; 57‑150 Hz 2 g |
| Şoc | Transport:15 g 11 ms; operating:2 g |
- Certificari & Conformitate
CE, UL/cUL, RCM(C-Tick), EAC(GOST-R), RoHS; compliant with Low-Voltage, EMC and Machinery Directives
Funcția de siguranță STO: SIL3 IEC 61508, PL e ISO 13849-1
Built-in E-filter meets C3 industrial-grade EMC requirements
- Built-in Function List
- 8-step on-board sequence programming for reduced external PLC hardware
- FlashDrop fast parameter copy tool support
- Motor thermal-protection, supracurent, supratensiune, subtensiune, earth-fault and output-short-circuit protection
- Stall protection, mechanical-brake control, Regulator PID
- Speed-compensated stop, DC-braking, flux-braking
- Multiple parameter-set switching
- Complete fault-history logging, maintenance counters (fan runtime, power-on hours)
- Power Terminal Definition
| Terminal | Funcţie |
| L1 L2 L3 | Three‑phase AC power input |
| U V W | Three‑phase motor output |
| BR+ BR‑ | Brake‑resistor connection (chopper built‑in; resistor external) |
| PE | Borna de pamant de protectie |
⚠️ Do NOT short-circuit BR+ and BRterminals. Brake resistor must be selected strictly according to manual specifications.
- Option List (Not factory-supplied; comanda separat)
- Control panels: ACS-CP-A advanced panel, ACS-CP-C basic panel
- Fieldbus modules: FPBA-01 Profibus-DP; FENA-01 PROFINET/EtherNet-IP; FMBA-01 Modbus-RTU
- I/O expansion MREL-01; encoder interface MTAC-01
- External brake resistor, panel extension cable, FlashDrop tool
- Application Boundary Notes
- IP20 rating permits cabinet-mount installation only; not suitable for wash-down or humid field environments.
- Lifting-load applications require external brake resistor and activation of built-in brake chopper.
- Current derating is mandatory for ambient temperature 40 °C and altitude 1000 m.
- Legacy obsolete model; spare-part stock availability is limited. Upgrade to ACS380-04-09A5-4 requires cabinet modification and full rewiring.