ABB CA5X-10 Auxiliary Contact Block - Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Despre Contact |

 ABB CA5X-10 Auxiliary Contact Block - Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare

electric/

ABB CA5X-10 Auxiliary Contact Block

Marca: ABB (Elveţia) | Official Part No.: 1SBN019010R1010 The CA5X-10 is a front-mount auxiliary contact extension block specially designed by ABB for AX series contactors. Este dotat cu 1 deschis în mod normal (NU) instantaneous contact. It is mainly used to expand nodes of the contactor control circuit, realizing functions such as operating status feedback, logic ...

  • Detalii despre produs

Marca: ABB (Elveţia) | Official Part No.: 1SBN019010R1010

The CA5X-10 is a front-mount auxiliary contact extension block specially designed by ABB for AX series contactors. Este dotat cu 1 deschis în mod normal (NU) instantaneous contact. It is mainly used to expand nodes of the contactor control circuit, realizing functions such as operating status feedback, logic interlocking, signal transfer and remote start/stop.

This block features a clip-on quick-mount structure for tool-free installation on the front of contactors. It comes with standard screw terminals. Its electrical performance complies with IEC 60947-5-1 and it holds major global certifications including CCC, CE and CB. It is widely applied in industrial scenarios such as low-voltage power distribution, motor control and automation control cabinets.

Codul modelului Explicația

Segment de codDescriere
CAGeneral prefix: Accessory series for contactor auxiliary contacts
5Product specification platform: Auxiliary contacts for 50mm frame size contactors of medium and low power ratings
XSeries indicator: Exclusively for AX series AC contactors and NX series contact relays
-10Codul de configurare a contactului: The first digit stands for the quantity of normally open (NU) contacte, and the second for normally closed (NC) contacte. 10 means 1NO + 0NC

Specificații tehnice de bază

Caracteristici electrice

Curent termic convențional (Ith): 16O (la 40℃, în conformitate cu IEC 60947-5-1)

Tensiune nominală de funcționare: Max. 690V AC/DC for auxiliary circuits

Curent nominal de funcționare (AC-15):

24V/127V: 6O

220V/240V: 4O

380V/440V: 3O

690V: 2O

Curent nominal de funcționare (DC-13):

24V: 6O

110V/125V: 0.55O

220V/250V: 0.3O

Curent de scurtă durată (Icw): 100A for 1 doilea; 140A for 0.1 doilea

Electrical operating frequency: 1200 operațiuni/oră (AC-15); 900 operațiuni/oră (DC-13)

Mechanical operating frequency: Max. 3600 operațiuni/oră

Durata de viata mecanica: ≥ 10 milioane de operațiuni

Mecanic & Parametrii de mediu

Tip de montare: Front clip-on quick installation for contactors

Tip de terminare: Borne cu clemă cu șurub

Recommended tightening torque: 0.6~0.8 N·m

Protecție la intrare: IP20 (terminal side, protection against accidental finger contact)

Temperatura ambiantă de funcționare: -25 ~ +55 ℃

Temperatura de depozitare: -40 ~ +70 ℃

Dimensiuni (L × H × D): 10mm × 47mm × 36mm

Net weight per unit: Aproximativ. 14g

Certificari: CCC, CE, CB; conform cu IEC 60947-5-1

Main Models in the Same Series

All below front-mount auxiliary contacts of CA5X series fit AX series contactors, differing mainly in contact configuration:

Model completConfigurare contactPartea nr.Aplicația principală
CA5X-101NU1SBN019010R1010Single NO contact for basic operating status feedback
CA5X-011NC1SBN019010R1001Single NC contact for safety interlock and stop signal feedback
CA5X-111NU+1NC1SBN019010R10111NO+1NC for general control circuit expansion
CA5X-202NU1SBN019010R1020Dual NO contacts for multi-channel parallel signal output
CA5X-022NC1SBN019010R1002Dual NC contacts for redundant safety circuit design

> Notă importantă: CA5X series is only compatible with AX / NX series contactors. For legacy A/AL/AE series contactors, please use CA5 series auxiliary contacts (de ex. CA5-10). The two series feature incompatible mechanical structures and must not be used interchangeably.

Contactoare compatibili

Main contactors: ABB AX series AC contactors (Gamă completă: AX06 ~ AX150)

relee: ABB NX series contact relays

Stacked installation: Până la 4 pieces of CA5X auxiliary contact blocks can be mounted on the front of one single contactor.

Instalare & Instrucțiuni de cablare

  1. Etape de instalare: Cut off power supply first. Align the auxiliary contact block with the guide grooves on the contactor front, then press down vertically until an audible click indicates full locking. Shake slightly to confirm firm installation. Pentru a elimina, press the release latch on the top and pull upwards.
  2. Definiția terminalului: Terminals marked “3” şi “4” correspond to the two ends of the single NO contact. The contact closes when the contactor is energized and opens when de-energized.
  3. Specificații de cablare: Suitable for solid/stranded wires of 0.5~1.5mm² and flexible wires of 0.5~1.0mm². Tighten screws at 0.6~0.8 N·m to avoid terminal damage or poor contact caused by excessive torque.
  4. Prohibited Operations: Never install or remove the block while powered on. It is designed exclusively for control circuit signals and shall not be connected to main power circuits for load switching. Do not operate continuously beyond rated load.

Troubleshooting Matrix

Fenomen de eroareCauza de bazăSoluții pas cu pas
Contact fails to close when contactor is energizedInstalare necorespunzătoare, contact oxidation or loose wiring1. Reinstall the block after power off and ensure full locking of clips.
2. Retighten terminals and check wire continuity.
3. Operate the contactor repeatedly to polish contacts; replace the block if severely oxidized.
Contact slab & flickering signalsInsufficient screw torque, terminal oxidation or overload1. Retighten terminals to specified torque.
2. Clean contact surfaces to remove oxide layer.
3. Verify load current and ensure compliance with AC-15 / DC-13 ratings.
Contactor jams and cannot pull in after installationMisaligned block, incomplete clip engagement or foreign debris1. Remove and reinstall the block with proper alignment to guide grooves.
2. Clean dust and foreign objects between contactor and block.
3. Inspect for deformation; replace the block if structural damage is found.
Abnormal overheating at terminals during operationLoose connection, insufficient wire gauge or circuit overload1. Reconnect wires and ensure full insertion of conductors into terminals (power off).
2. Confirm wire cross-section matches load current.
3. Check circuit current; prolonged overload operation is forbidden.

Both CA5-10 and CA5X-10 are front-mount auxiliary contacts with 1 contact normal deschis. They share nearly identical electrical parameters but belong to two generations of contactor platforms with completely incompatible mechanical mounting structures, and must never be mixed. CA5-10 matches legacy A series contactors, while CA5X-10 is dedicated to the new AX series.

  1. Full Comparison of Core Parameters
Element de comparațieCA5-10 (For Legacy A Platform)CA5X-10 (For New AX Platform)
Poziționarea produsuluiPrevious-generation general auxiliary contact, pentru întreținere & replacement of existing equipmentNew-generation mainstream model, matched with current AX contactors
Official Part No.1SBN010010R1010 (Domestic code: 10069838)1SBN019010R1010
Contactoare compatibiliA9~A110, AL9~AL40, AE45~AE75, AF50~AF110, N series contact relaysFull AX06~AX150 series, NX series contact relays
Configurare contact1NU (1 instantaneous normally open contact)1NU (1 instantaneous normally open contact)
Curent termic convențional (Ith)16O (40℃, IEC 60947-5-1)16O (40℃, IEC 60947-5-1)
Tensiunea nominală de izolație (Ui)690V AC/DC690V AC/DC
Curent nominal de funcționare (AC-15)24V/127V: 6O; 220V/240V: 4O; 380V/400V: 3O; 690V: 2O24V/127V: 6O; 220V/240V: 4O; 380V/400V: 3O; 690V: 2O
Curent nominal de funcționare (DC-13)24V: 6O; 110V/125V: 0.55O; 220V/250V: 0.3O24V: 6O; 110V/125V: 0.55O; 220V/250V: 0.3O
Curent de scurtă durată (Icw)100O (1s); 140O (0.1s)100O (1s); 140O (0.1s)
Viața mecanică≥ 10 milioane de operațiuni≥ 10 milioane de operațiuni
Mechanical Operating FrequencyMax. 3600 operațiuni/orăMax. 3600 operațiuni/oră
Electrical Operating Frequency (AC-15)Max. 1200 operațiuni/orăMax. 1200 operațiuni/oră
Tip de montareFront clip-on quick installationFront clip-on quick installation
Max. Stacked Quantity per ContactorPână la 4 unitatiPână la 4 unitati
Termination TypeBorne cu clemă cu șurubBorne cu clemă cu șurub
Recommended Tightening Torque0.6~0.8 N·m0.6~0.8 N·m
Dimensiuni (L × H × D)Aproximativ. 9.5mm × 46.8mm × 32.5mmAproximativ. 10mm × 47mm × 36mm
Greutate netăAproximativ. 14gAproximativ. 14g
Protecție la intrareIP20 (protecție împotriva contactului cu degetele)IP20 (protecție împotriva contactului cu degetele)
Temperatura de operare-25 ~ +55 ℃-25 ~ +55 ℃
CertificariCE, CCC, CB, conform cu IEC 60947-5-1CE, CCC, CB, conform cu IEC 60947-5-1
  1. Key Differences Analysis

2.1 Fundamental Difference: Non-interchangeable Mechanical Interface

The two models are similar in appearance and overall size, but differ in clip grooves and linkage structures, which are designed for dedicated contactor housings respectively:

Clips of CA5-10 fit exclusive grooves on A series contactors.

Clips of CA5X-10 match the new interface of AX series contactors.

Forced assembly will lead to loose clips, out-of-sync contacts and contactor jamming, and may even damage internal mechanisms. This is strictly prohibited in selection and application.

2.2 Product Generation & Supply Positioning

CA5-10: Mature legacy product, mainly used for maintenance and replacement of existing A series contactors. Not recommended for new projects.

CA5X-10: Current flagship product of ABB, supporting AX series contactors (successor of legacy A series). It features stable stock and comprehensive technical support.

2.3 Identical Electrical Performance & Compatible Circuit Design

They adopt the same technical platform for contact materials, arc extinguishing structures and electrical parameters. Load capacity and service life are equivalent under the same utilization category. Control circuit design and wiring rules can be fully followed between each other.

  1. Selecţie & Recomandări de înlocuire
  2. Maintenance of Existing Equipment: If the original contactors are A/AL/AE/AF series, select CA5-10 exclusively. CA5X-10 cannot be used as a replacement.
  3. New Project Design: Prioritize the combination of AX series contactors + CA5X series auxiliary contacts. This is ABB’s mainstream solution with reliable long-term supply and after-sales service.
  4. Contact Configuration Expansion: Both series provide multiple contact types such as CA5X-01/11/20/02 with consistent naming rules. Select models according to NO/NC requirements of control circuits.

Prev:

Lasă un răspuns