Banner BT26S Diffuse Fiber Optic Probe - Contactor,întrerupător de circuit,senzor,Codificator,PLC,Convertor

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Despre Contact |

 Banner BT26S Diffuse Fiber Optic Probe - Contactor,întrerupător de circuit,senzor,Codificator,PLC,Convertor

electric/

Banner BT26S Diffuse Fiber Optic Probe

(Banner BT26S, Partea nr.: 17285) Tip de produs: Bifurcated glass fiber, diffuse fiber optic probe (fiber amplifier not included; must be used with Banner fiber amplifier) Model Definition BT: Bifurcated Threaded 26: Lungime 72 inch (1.829 m) S: Stainless steel monocoil armored sheath Core Specifications Item Parameter Sensing Mode Diffuse / Reflective Fiber Material Glass fiber ...

  • Detalii despre produs

(Banner BT26S, Partea nr.: 17285)

Tip de produs: Bifurcated glass fiber, diffuse fiber optic probe (fiber amplifier not included; must be used with Banner fiber amplifier)

Definiția modelului

BT: Bifurcated Threaded

26: Lungime 72 inch (1.829 m)

S: Stainless steel monocoil armored sheath

Specificații de bază

ArticolParametru
Sensing ModeDifuz / Reflective
Fiber MaterialGlass fiber
Fiber Bundle Diameter0.125″ (3.2 mm)
Lungimea totală72 in = 1.829 m
Probe Thread#5/16-24 UNF external thread, brass sensing tip
SheathStainless steel single-coil metal hose
Max Operating Temperature249 ℃ (480 )
Minimum Bend Radius25 mm
Beam DirectionÎn linie, coaxial
Compatible AmplifiersDF-G series, R55FVQ and other Banner fiber amplifiers
Stare produsDiscontinued by manufacturer

Caracteristici structurale

  1. Bifurcated design: One fiber for light emission, one for light reception. Dual fibers integrated inside one armored cable, Y-split tail to connect to fiber amplifier.
  2. Brass threaded sensing tip: Easy threaded mounting, suitable for confined spaces.
  3. Stainless steel corrugated armor: Crush-resistant, abrasion-resistant, works in harsh environments with high temperature, oil mist and dust.
  4. High-temperature glass fiber: Different from plastic fiber; suitable for workpiece detection in ovens, echipamente de tratament termic.

Aplicații tipice

Presence detection of high-temperature workpieces

Liquid level and leakage detection

Small target detection for metallic and non-metallic parts

Compact installation space and heavy vibration equipment

Cuptoare, die casting and heat treatment machinery

Referință de model de înlocuire

BT26S is discontinued. Alternative models from the same series:

  1. BT23S: Straight tip with identical thread specification, lungime 36 inch (0.914 m), short version;
  2. BAT26S: 72 inch, 5/16-24 thread, 90° right-angle beam exit (lateral light emission);
  3. For longer or shorter cable length, refer to BT13S, BAT23S.

Instalare & Ghid de întreținere

  1. Thread mounting: Tighten with 5/16-24 nut. Do not over-torque the fiber root to avoid breakage of glass fiber.
  2. Bending control: Cable routing with bend radius ≥25 mm; sharp bending is prohibited.
  3. End face maintenance: Oil and dust contamination on brass tip will attenuate optical signal. Clean fiber end face with anhydrous ethanol.
  4. Selection reminder: The fiber probe cannot output switching signal independently; fiber amplifier is required for PLC connection.

HS Code Reference

8544700000 (Optical fiber cables)

Sensing Distance of BT26S Diffuse Probe

Notă importantă: BT26S is a passive fiber probe with no fixed detection range. Sensing distance depends on paired fiber amplifier (DF-G1 / DF-G2 / DF-G3), and is heavily affected by reflectivity of target object.

Typical Test Data (Paired with Banner DF-G3 high-power amplifier, white high-reflectivity target)

Reliable operating range: 0~150 mm

Maximum trigger distance: aproximativ. 200 mm

For low-reflectivity black workpiece, effective distance drops significantly, typically 0~50 mm.

Caracteristici cheie

  1. No built-in lens; fiber bundle diameter 3.2 mm with relatively large beam divergence. The farther the distance, the larger the spot and faster optical attenuation.
  2. Banner official datasheet does not specify fixed rated range; only Excess Gain curve is provided. Model selection must refer to excess gain curve instead of fixed range value.
  3. Recommended operating window: 0~100mm. Sufficient excess gain within this range, retains margin under dusty and oily conditions. Margin is very limited beyond 150 mm; signal loss may occur with minor contamination.

Factors Affecting Sensing Distance

Amplifier model: DF-G3 DF-G2 DF-G1 (DF-G3 has highest optical power and longest range)

Target color / reflectivitate: White paper / aluminum plate grey plastic black rubber

Contamination on probe end face, mounting angle and background reflection interference

High-temperature operation: Optical loss increases slightly at 249℃, which shortens effective sensing distance

Recomandare de selecție

Keep detection distance ≤100mm for high-temperature applications; for black workpiece, control within ≤40~50mm.

If longer diffuse sensing range is required, select BT series fiber with focusing lens. BT26S straight tip is optimized for high temperature rather than long-distance detection.

Material Breakdown of Banner BT26S (17285)

  1. Fiber bundle: Optical glass fiber (F2 core, EN1 cladding), multi-strand glass fiber forming bifurcated diffuse fiber bundle.
  2. Threaded sensing tip: Alamă, 5/16-24 UNF external thread, high temperature resistant and convenient for mechanical locking.
  3. Cable armored sheath: 302 stainless steel single-coil metal hose (Banner SteelSkin armor), crush-proof, abrasion-resistant, oil and dust resistant.
  4. Y-bifurcation connector (black plastic tail housing): Molded thermoplastic engineering plastic.
  5. Fiber end bonding: Optical grade epoxy resin (versiune standard; M900 suffix model adopts fused joint without epoxy).

Material Performance Highlights

Glass fiber: Max temperature resistance 249℃, transmits visible and infrared light, ideal for high-temperature applications, superior to plastic fiber.

Brass tip: Good machinability and high thread strength; evaluate compatibility for strong acid and alkali corrosive environments.

302 stainless steel armor: Anti-cut and anti-crush, maintains flexibility to protect internal glass fiber from fracture.

IP Rating Statement for Banner BT26S

Official datasheet does not specify standard IP protection rating. BT26S is a passive fiber assembly without electronic circuitry. IP rating standard applies to sensors with electronic housing, so no IP certification is provided by manufacturer.

Environmental Resistance of Each Component

  1. Brass sensing tip: Resists dust, oil mist and splash water; not suitable for high-pressure wash or long-term immersion. Water or oil contamination on fiber end face directly causes optical signal attenuation.
  2. 302 stainless steel monocoil armor: Strong mechanical protection against compression and abrasion. The gaps between metal coils allow ingress of water and dust, not hermetically sealed waterproof tube.
  3. Y-shaped plastic bifurcation base: Only protects against common dust and splash water; immersion is prohibited.

Distincție importantă (Common Confusion)

BT26S (fiber probe): No IP rating

Matching Banner fiber amplifier (DF-G series): Amplifier housing is IP67 rated; only the electronic amplifier has IP protection grade.

Application Selection Suggestion

✅ Suitable: Uscat / oil mist, dusty environment, occasional splash water, high-temperature equipment (≤249℃)

❌ Not suitable: High-pressure spray cleaning, continuous water immersion, strong corrosion soaking scenarios

Prev:

Următorul:

Lasă un răspuns