Leuze CML720i-T05-240.A-M12 - Contactor,întrerupător de circuit,senzor,Codificator,PLC,Convertor

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Despre Contact |

 Leuze CML720i-T05-240.A-M12 - Contactor,întrerupător de circuit,senzor,Codificator,PLC,Convertor

electric/

Leuze CML720i-T05-240.A-M12

Articol nr.: 50119370|Measuring light curtain transmitter (transmitter only, must be used with paired receiver) ✅ Model Code Explanation Field Description CML720i CML series measuring light curtain; 720i general-purpose measuring light curtain T Transmitter; R = Receiver 5 Beam pitch 5 mm 240 Effective measuring height 240 mm A A = Axial M12 connector (straight outlet); R = ...

  • Detalii despre produs

Articol nr.: 50119370|Measuring light curtain transmitter (transmitter only, must be used with paired receiver)

✅ Model Code Explanation

DomeniuDescriere
CML720iCML series measuring light curtain; 720i general-purpose measuring light curtain
TTransmitter; R = Receiver
5Beam pitch 5 mm
240Effective measuring height 240 mm
OA = Axial M12 connector (straight outlet); R = Rear outlet
M12conector M12, 5-pin A-coded

📌 Key Technical Specifications

Principiu: Infrared through-beam measuring light curtain, NOT safety light curtain. Used for dimension inspection, object contour detection, numărând, material level monitoring and other measurement applications

Effective measuring range: 240 mm, total 48 beams, beam pitch: 5 mm

Minimum detectable object diameter: 10 mm

Interval de operare: 0.1~3.5 m (guaranteed range)

Alimentare electrică: DC 18~30V, reverse polarity & protectie la scurtcircuit

Cycle response time: 1.84 Domnișoară

Sursa de lumina: Infrared LED 940nm

Clasa de protectie: IP65

Temperatura mediului ambiant: Operating -30℃ ~ +60℃; Storage -40℃ ~ +70℃

Locuințe: Aluminum alloy profile, supplied with 2 BT-NC mounting sliders

Dimensiunea de ansamblu: W29 × D35.4 × L315 mm

🔌 Electrical Interface (M12 5-pin male A-coded)

PinDefiniţie
1FE Shield
2V+ Power Positive
3GND Power Ground
4RS485 Tx+
5RS485 Tx-

The transmitter only emits infrared beams. All communication and signal output are implemented on the receiver side. Optional receiver interfaces: CANopen / Profinet / IO-Link / Ieșire analogică

🧩 Matching Receiver Selection (Aceeași specificație: 240mm, 5mm beam pitch)

CML720i-R05-240.A/CN-M12: CANopen bus

CML720i-R05-240.A/PB-M12: Profibus

CML720i-R05-240.A/PN-M12: Profinet

CML720i-R05-240.A/CV-M12: Analog voltage / current output

📋 Typical Applications

Înălţime / width measurement of objects on conveyor lines

Missing part inspection & contour detection for cartons

Material counting, gap detection

Transparent object detection (CML720i supports transparent part recognition)

Triere, ambalaj, dimension inspection for timber & boards

⚠️ Important Distinction

  1. CML720i = Measuring light curtain, no safety certification. Cannot be used for personnel safety protection; Safety light curtain series: MLC.
  2. Complete system = Transmitter (T) + Receptor (R) paired. Transmitter alone cannot work.
  3. Sprijină 3 scanning modes: Parallel beam / Slanted beam / Cross beam, configurable via receiver.

HS Code Reference

90314990 (Optical measuring sensor / photoelectric detection device)

Ghid de depanare

  1. Power ON, transmitter green LED steady ON: Normal; Intermitent: Synchronization error (transmitter-receiver out of sync, defecțiune de cablare)
  2. Niciun semnal: Check parallel installation of transmitter & receptor, operating distance ≤3.5m, no strong direct light on lens
  3. Inaccurate measurement: Curățați lentila, verify beam mode setting, eliminate reflection interference

✅ Matching Receiver for CML720i-T05-240.A-M12 (Item No.50119370)

Model rule: CML720i-R05-240.A/xx-M12

R=Receiver; 05=5mm beam pitch; 240mm measuring height; A=Axial M12 straight connector; /xx = Interface suffix

Complete Receiver ModelItem No.Tip de interfață
CML720i-R05-240.A/CN-M1250119608CANopen
CML720i-R05-240.A/PN-M1250131878Profinet
CML720i-R05-240.A/PB-M1250119609Profibus
CML720i-R05-240.A/CV-M1250119610Analogic (Voltaj / Actual)
CML720i-R05-240.A/L-M1250119606IO-Link

Note de selecție

  1. Transmitter and receiver must be fully matched: 5mm beam pitch, 240mm measuring height, A-type axial M12 connector consistent with transmitter. Only receiver adds interface suffix /xx
  2. Transmitter only carries power & sync lines; All measurement output and bus communication are integrated in receiver
  3. Identical mechanical dimensions: W29 × D35.4 × L315 mm, supplied with 2 BT-NC mounting sliders

Cable Information

Sync cable between transmitter & receptor: M12 5-core, connects Transmitter ↔ Receiver

Receiver connects to PLC via separate bus / analog cable

Full Wiring for Slogan CML720i (4 Interface Versions)

General architecture: Receiver X1 (8-pin M12 A-coded) main port: Alimentare electrică + IO + sync line to transmitter; Transmitter X3 fixed as 5-pin M12 A-coded.

Transmitter Model: CML720i-T05-240.A-M12 (X3: 5-pin M12)

Receiver X1【8-pin M12 A-coded】(Pin definition identical for all versions!)

✅ Receiver X1 (8-pin M12 A-coded, common for all variants)

PinSemnalObservații
1V+ DC24VPutere pozitivă
2I/O1 (Configurabil)Factory default: Teach input
3GND 0VPower Ground
4C/Q IO-LinkIO-Link communication line (reserved for CV/CN/PN versions)
5I/O2 (Configurabil)Can be set as alarm / status output
6RS485 Tx-Sync signal between transmitter & receptor
7RS485 Tx+Sync signal between transmitter & receptor
8FE/ShieldHousing earth, shield connect to this pin

✅ Transmitter X3 (5-pin M12 A-coded, fixed definition)

PinSemnal
1FE Shield
2V+ 24V
3GND 0V
4RS485 Tx+
5RS485 Tx-

👉 Receiver X1 Pin1,Pin3,Pin6,Pin7 → Connect to Transmitter X3 Pin2,Pin3,Pin4,Pin5. Use Leuze Y-type sync cable, max length 20m.

1️⃣ CML720i-R05-240.A/PN-M12|Profinet Version

Receiver equipped with 3 M12 connectors:

X1: 8-pin (Putere + Sync + IO, see table above)

X2: BUS IN (4-pin M12 D-coded)

X3: BUS OUT (4-pin M12 D-coded)

Profinet D-coded M12 (4-pin):

PinSemnalCuloarea firului
1TD+Galben
2RD+Alb
3TD-Portocale
4RD-Albastru

Wiring Architecture:

DC24V supplied to receiver X1; Sync cable from X1 to transmitter; Profinet bus connects PLC/switch to X2, X3 daisy-chains next PN device; Enable terminator resistor on last station.

Supports PLC reading: Blocked beam number, height value, diagnostic status.

2️⃣ CML720i-R05-240.A/CN-M12|CANopen Version

Receptor: X1 (8-pin, Putere + Sync) + X2 (5-pin M12 A-coded CAN bus)

CAN bus X2 (5-pin M12 A-coded)

PinSemnal
1FE Shield
2NC Not Connected
3CAN GND
4CAN H
5CAN L

Cablaj: X1 power & sync to transmitter; CAN H/CAN L connect to CAN bus; 120Ω terminator resistor required at both ends of bus.

3️⃣ CML720i-R05-240.A/L-M12|IO-Link Version

Receiver only has X1 (8-pin M12 A-coded), no extra bus port. IO-Link multiplexes Pin4 (C/Q) of X1.

Pin1: 24V+

Pin3: 0V

Pin4: C/Q IO-Link communication → Directly connect to PLC IO-Link master port

Pin2/Pin5: Digital IO (Teach, fault output)

Pin6/7: Sync to transmitter

IO-Link master reads measured height and beam data directly, no extra bus cable required.

4️⃣ CML720i-R05-240.A/CV-M12|Analog Version (Voltaj / Actual)

Receiver also only has X1 (8-pin M12 A-coded), analog output on X1 Pin7.

Pin7: Analog OUT Analog Output

Parameter switchable: 0~10V or 4~20mA

Full scale corresponds to measuring height 0~240mm

Pin1/3: 24V Power Supply

Pin6/7: Sync signal to transmitter

Pin2/Pin5: Digital IO (Vina / Teach)

⚠️ Notă: Analog output and RS485 sync share Pin7, internal auto switching. Wiring remains unchanged; voltage/current mode configured via Leuze software.

📌 General Wiring Guidelines

  1. Power supply range DC18~30V, DC24V recommended; Isolated power supply required, shield single-point grounding.
  2. Sync cable (Transmitter ↔ Receiver) max length 20m; Bus cable max 40m, shielded cable mandatory.
  3. Secvența de cablare: Connect shield ground first → Wire all signals → Power ON; Power OFF before disassembly.
  4. IO1 default as Teach input, short to GND to trigger teach routine for zero calibration.
  5. Separate signal cables from power cables to avoid interference from frequency converters.

🧾 Quick Selection Guide

PLC Siemens: Prefer PN Profinet version

Industrial control system with CAN bus: CN CANopen

Compact PLC with IO-Link master: L IO-Link

Legacy equipment requiring analog acquisition: CV 4~20mA / 0~10V

Prev:

Următorul:

Lasă un răspuns