LS ELECTRIC (formerly LG Industrial Systems), K120SE series economical CPU modul, sfârşitul vieţii, only stock & second-hand spare parts available on the market.
✅ Model Definition
K7M: MASTER-K120S CPU series
DR: D = DC24V Input, R = Relay Output
14: Total I/O points =14 (8 Intrări + 6 Ieșiri)
UE: K120SE economical version (Compare with standard U series, program memory: 2K pași)
📋 Core Specifications
| Articol | Parametru |
| Alimentare electrică | AC85~264V wide range, commonly AC220V |
| Intrare digitală | 8 puncte DC24V, compatibil cu chiuveta/sursa; Input filter 0~1000ms configurable, default 10ms; Adresa: P000~P007 |
| Ieșire digitală | 6-point relay contact output; Single contact rating: AC250V / DC110V, resistive load 2A; Adresa: P040~P045 |
| Memoria programului | 2K steps for UE economical model; K7M-DR14U standard version:7K pași |
| Viteza de execuție | Instrucțiune de bază: 0.4s per step |
| Contor de mare viteză | 4 canale; single-phase max.100kHz, two-phase 50kHz; supports 10s pulse capture (2 puncte) |
| Porturi de comunicație | Built-in RS232C + RS485; connect HMI, host PC, multi-PLC 1:N network |
| Păstrarea datelor | Supercondensator, no battery; data retention approx. 20 days at ambient temperature |
| Expansiune | Compatible with G7E digital modules, G7F analog modules (AD/DA/PT100) |
| Programming Language | Ladder Diagram LD, Software de programare: KGLWIN |
🧩 Typical Application Scenarios
Small standalone machine control: transportoare, small presses, mașini de ambalare, simple HVAC, flameproof mining switches, control cabinet accessories. Suitable for digital logic plus limited high-speed counting.
Relay output cannot generate pulse for positioning (DT/DRT transistor model required for positioning)
⚠️ Important Notes
- Relay output limitation: Mechanical contact, not suitable for frequent on/off operations; max ~1200 switching cycles/hour, frequent operation accelerates contact burnout.
- Discontinued model: Not recommended for new projects. For replacement maintenance, verify program capacity first (UE=2K steps, standard DR14U=7K; program exceeding 2K cannot be downloaded directly).
- Comunicare: RS485 uses LS proprietary Cnet protocol, compatible with SCADA & touchscreen.
- Built-in DC24V sensor supply: The PLC provides 24VDC for sensors, limited capacity.
📌 K120SE Series Lineup
K7M-DR10UE: 6DI+4DO
K7M-DR14UE: 8DI+6DO
K7M-DR20UE:12D+8C
K7M-DR30UE:18DI+12DO
🔁 Alternative Selection
Înlocuire casnică: Inovance H1U-0806MR, Xinje XC2-08R-E;
LS upgraded platform: XBC series (XBC-DR14E)
🛠 Common Troubleshooting
- PWR lamp off: AC power supply, blown internal 2A time-delay fuse
- RUN lamp off: program error, STOP mode via switch/host PC, watchdog overflow
- Nicio acțiune de ieșire: aged/burned relay contact (common on second-hand units), broken COM wiring
- Eșec de comunicare: RS232/485 wiring polarity, station number, baud rate, terminating resistor
Software de programare pentru LS K7M-DR14UE (MASTER-K120S)
✅ Official programming software: KGLWIN
XG5000 mentioned before is for XGB/XGT series, not compatible with K120S K7M, do not install the wrong software.
Version Info
Common stable release: KGLWIN 3.62, also 3.5, 3.7 available. Originally designed for Win98/XP. Win10/Win11 requires compatibility mode.
Languages: Ladder LD, Instruction List IL
Funcții: Program edit, monitor online, I/O force, upload/download, comment, diagnosticarea defecțiunii
Handheld programmer: KLD-150S (old portable unit for field commissioning)
Online Connection Method
Built-in RS232C programming port on PLC:
- Moştenire: PC DB9 serial direct cable
- Modern PCs without native serial port: USB to RS232 adapter (CH340/PL2303 chip), select corresponding COM port inside KGLWIN
Nota: Install driver for USB-serial adapter. Parametri de comunicare: 9600 baud, nici o paritate, 8 biți de date,1 oprește puțin.
Software Comparison Table
| Seria PLC | Software de programare |
| MASTER-K (K120S/K80S, K7M) | KGLWIN |
| GLOFA-GM | GMWIN |
| XGB / XGT (XBC, XGK etc.) | XG5000 |
Common Pitfalls
- XG5000 cannot recognize K7M-DR14UE. Use XBC series if new replacement required.
- Running KGLWIN on Win10/11: XP compatibility mode + run as administrator.
- Eșec de comunicare: Check USB-serial driver, COM port number, baud rate, RS232 wiring.
Supported Operating Systems for KGLWIN (for K7M K120S PLC)
Officially supported OS (per manual): Windows 95, Windows 98, Windows 2000, Windows XP (32-pic)
✅ Practical field operation (not official native support, run via compatibility mode)
- Windows7 (32bit /64bit) : Most stable modern OS, preferred for industrial commissioning
- Windows10 (64pic) : Require XP compatibility mode + run as administrator. USB-RS232 driver is the main issue. LTSC version performs better than home edition.
- Windows11 (64pic) : Operable but unstable, occasional crash & serial communication anomaly, not recommended for primary commissioning.
❌ Unsupported
MacOS, Linux (no native release; can run via virtual machine with XP/Win7)
Windows ARM edition (Surface ARM laptops, abnormal execution)
Windows S mode
⚙️ Configuration Steps for Win10/11
- Right-click KGLWIN.exe → Properties → Compatibility
- Verifica: Run this program in compatibility mode for: Windows XP (Service Pack3)
- Verifica: Run this program as an administrator
- Disable antivirus/Defender real-time protection to avoid serial port driver interception
- Communication depends on USB to RS232 (CH340/PL2303). Industrial-grade serial converter is preferred.
💡 Practical Engineering Suggestion
Maintenance for legacy K120S (K7M-DR14UE): Prepare Win7 32-bit industrial PC, highest online success rate.
If only Win10/11 available: Install XP on virtual machine, pass-through USB serial adapter to VM; much more stable than running KGLWIN directly on host OS.
Full Model List for LS MASTER-K120S (K7M) CPU
Series Description:
UE = economical type (2K program steps, putere AC220V). K7M-DR14UE belongs to this group
U = standard type (7K program steps, AC220V)
U/DC = standard type DC24V power supply
DR: Ieșire releu; DT: NPN Transistor Output; DRT: Mixed Relay + Ieșire tranzistor
- UE Economical Series (AC220V, 2K pași)
| Model | I/O totală | Intrare | Ieșire | Tip ieșire |
| K7M-DR10UE | 10 puncte | 6DIN | 4DO | Releu |
| K7M-DR14UE | 14 puncte | 8DIN | 6DO | Releu |
| K7M-DR20UE | 20 puncte | 12DIN | 8DO | Releu |
| K7M-DR30UE | 30 puncte | 18DIN | 12DO | Releu |
- U Standard Series (AC220V,7K pași)
| Model | I/O totală | Intrare | Ieșire | Tip ieșire |
| K7M-DR10U | 10 puncte | 6DIN | 4DO | Releu |
| K7M-DR14U | 14 puncte | 8DIN | 6DO | Releu |
| K7M-DT10U | 10 puncte | 6DIN | 4DO | Tranzistor NPN |
| K7M-DT14U | 14 puncte | 8DIN | 6DO | Tranzistor NPN |
| K7M-DR20U | 20 puncte | 12DIN | 8DO | Releu |
| K7M-DT20U | 20 puncte | 12DIN | 8DO | Tranzistor NPN |
| K7M-DRT20U | 20 puncte | 12DIN | 8DO | 4Relay+4Transistor |
| K7M-DR30U | 30 puncte | 18DIN | 12DO | Releu |
| K7M-DT30U | 30 puncte | 18DIN | 12DO | Tranzistor NPN |
| K7M-DRT30U | 30 puncte | 18DIN | 12DO | 8Relay+4Transistor |
| K7M-DR40U | 40 puncte | 24DIN | 16DO | Releu |
| K7M-DT40U | 40 puncte | 24DIN | 16DO | Tranzistor NPN |
| K7M-DRT40U | 40 puncte | 24DIN | 16DO | 12Relay+4Transistor |
| K7M-DR60U | 60 puncte | 36DIN | 24DO | Releu |
| K7M-DT60U | 60 puncte | 36DIN | 24DO | Tranzistor NPN |
| K7M-DRT60U | 60 puncte | 36DIN | 24DO | 20Relay+4Transistor |
- U/DC Standard DC Power Series (putere DC24V,7K pași)
K7M-DR10U/DC, K7M-DR14U/DC, K7M-DT10U/DC, K7M-DT14U/DC
K7M-DR20U/DC, K7M-DT20U/DC, K7M-DRT20U/DC
K7M-DR30U/DC, K7M-DT30U/DC, K7M-DRT30U/DC
K7M-DR40U/DC, K7M-DT40U/DC, K7M-DRT40U/DC
K7M-DR60U/DC, K7M-DT60U/DC, K7M-DRT60U/DC
- Modele speciale
K7M-EL60A: Elevation dedicated K120S CPU
- K120S Expansion Modules G7E Series (matched with above CPU)
Module digitale
G7E-DR10A (6DI+4DO Relay), G7E-DR20A (12DI+8DO Relay)
G7E-TR10A (10-point transistor output), G7E-RY08A (8-point relay output)
G7E-DC08A (8-point DC input), G7E-DR08A (4DI+4DO Relay)
Module analogice
G7F-AD2A 2-channel AI; G7F-DA2I 2-channel AO; G7F-ADHB 4-channel high-speed AD
G7F-RD2A RTD PT100; G7F-TC2A Thermocouple module
Communication Special Modules
G7L-CUEB, G7L-CUEC C-net communication module
⚠️ Replacement Reminder
- UE economical model only has 2K program steps, cannot directly replace U standard model (7K). Download error occurs when program exceeds 2K steps.
- DR relay output cannot send pulse for positioning; DT transistor model for pulse output; DRT mixed model handles both switch signal & puls.
- All K120S (K7M) întreruptă. Programming software is KGLWIN, XG5000 not supported.
Engineering Application Cases for K7M-DR14UE
Precondition: Pure digital logic, limited high-speed counting; relay output without high-frequency positioning pulse; program capacity limit 2K steps. Suitable for small standalone machines & legacy equipment retrofit.
Caz 1: Flameproof Distribution Switch Control for Underground Mining (Classic Real Project)
Atribuire I/O: 8DIN: Supraîncărcare, scurgere, door interlock, oprire de urgență, butonul de testare, feedback de stare; 6DO: Close command, trip command, alarma de eroare, run indicator, test output
System Architecture: K7M-DR14UE本体, RS485 upload signal to surface HMI/host, remote collection & alarm for switch status
Logică: Leakage lockout, overload time-delay trip, door interlock (closing prohibited with cabinet open), fault latch; high-speed counter for pulse current signal
Selection reason: AC wide voltage 85~264V, noise immunity input filter; RS485 încorporat, compact size for flameproof enclosure; relay output drives intermediate relay for main circuit
Prescripţie: Only protection logic, no complex calculation, short program well within 2K step limit
Caz 2: Small Belt Conveyor / Assembly Line Standalone Control
Atribuire I/O: DIN: Start button, Stop, oprire de urgență, belt deviation sensor, nivel material, block feedback; DO: Contactor principal, buzzer alarm, run lamp, fault lamp, belt cleaner solenoid valve
Proces: Sequential belt start/stop, delay start/stop, fault shutdown + audible & visual alarm, deviation protection, auto start/stop based on material level; manual / auto mode switch
Accesorii optionale: Touch screen via RS232/485 for fault code viewing; multi-conveyor 1:N interlock via RS485 network
Important: Relay output suitable for contactor coil; Do NOT drive high-power load directly with PLC relay, add intermediate relay for isolation.
Cazul 3: Auxiliary Packaging Machine (Discharging, Material stopper, Cylinder sequence action)
Utilizare: Small packaging auxiliary station, material stopper cylinder, material detection, numărând, auto stop when bin full
DIN: Photoelectric sensor, low material detection, cylinder position magnetic switch, start/reset; DO: Solenoid valve, indicator lamp, alarma
Proces: Material detected → stopper cylinder extend → discharge → delay retract, numărarea produselor finite, auto stop at full bin; high-speed counter for product count
Prescripţie: Cannot control servo/stepper positioning (DR relay no pulse output); replace with DT transistor version if positioning required.
Case4: Small HVAC / Air Handling Unit (Fresh air unit, simple constant temperature cabinet logic)
DIN: Differential pressure switch, freeze protection switch, fan overload, manual-auto selector; DO: Fan contactor, motorized damper, alarma
Soluţie: CPU only for digital interlock; external G7F-RD2A/TC2A analog module for PT100 / thermocouple temperature sampling if PID needed
Logică: Ventilator & damper interlock, freeze protection, differential pressure alarm, fault shutdown; RS485 connect to building SCADA for remote monitoring
Case5: LV Cabinet / Control Cabinet Logic Monitoring Unit (Switchgear status acquisition)
DIN: Circuit breaker on/off feedback, spring charged status, cabinet door limit, fault signal; DO: Close circuit, alarma de eroare, indicator lamp
Funcţie: Switchgear status collection, fault latch, remote upload. Widely used in legacy cabinet retrofit project, low-cost replacement for old relay logic
Avantaj: AC220V power supply taken directly from cabinet control circuit, no extra DC supply required.
Case6: Simple Elevating Platform / Material Hoist (Safety interlock control)
DIN: Upper/lower limit, ultimate limit, oprire de urgență, door interlock, manual button; DO: Up contactor, down contactor, alarma
Proces: Limit protection, emergency stop latch, lifting prohibited with door open; electrical interlock to prevent simultaneous activation of up & down contactor
⚠️Safety Notice: Lifting equipment requires independent safety relay. PLC logic only acts as auxiliary control and cannot serve as sole safety circuit.
K7M-DR14UE Specific Pitfalls & Sfaturi de selecție
- 2K step limitation: Complex process, many comments, multi-sequence steps may exceed capacity and cause download failure. Use K7M-DR14U (7K standard version) for complex projects.
- Ieșire releu: Not suitable for frequent switching; select DT transistor model for high-speed solenoid valves.
- Comunicare: RS485 Cnet protocol for HMI & SCADA; KGLWIN software, XG5000 incompatible.
- Expansiune: Add G7E digital modules, G7F analog modules if insufficient I/O points.
Aplicații nerecomandate
Servo / stepper motor positioning (fără ieșire de impuls)
High-frequency solenoid valves (fast contact wear)
Mass analog signal + heavy PID calculation (easy program overflow under 2K steps)
New greenfield projects (întreruptă, LS XBC series preferred)