OMRON CP1H-XA40DR-A-EDU

CPU Unit with Built-in Analog I/O, Ieșire releu, Educational Training Version CP1H-XA40DR-A-EDU: OMRON Sysmac-CP1H compact PLC CPU with built-in analog I/O, ieșire releu, for educational laboratory training. Its commercial counterpart is CP1H-XA40DR-A. The suffix-EDU stands for Education version. Hardware is identical, firmware and licensing are oriented for teaching scenarios. Model Number Decoding Segment Description CP1H ...

  • Detalii despre produs

Unitate CPU with Built-in Analog I/O, Ieșire releu, Educational Training Version

CP1H-XA40DR-A-EDU: OMRON Sysmac-CP1H compact PLC CPU with built-in analog I/O, ieșire releu, for educational laboratory training. Its commercial counterpart is CP1H-XA40DR-A. The suffix-EDU stands for Education version. Hardware is identical, firmware and licensing are oriented for teaching scenarios.

  1. Model Number Decoding
SegmentDescriere
CP1HSysmac‑CP1H series compact PLC
XCPU with on‑board analog input & ieșire
OAC power supply: 100‑240V AC
40Total de puncte I/O: 40 (24 intrări,16 iesiri)
DRD = DC input; R = Relay contact output
-OAC power variant
‑EDUEducational training unit. Supplied for school labs only. No industrial‑grade warranty. Pin‑out and I/O specifications are fully identical to CP1H‑XA40DR‑A
  1. Specificații hardware de bază
  2. I/O digitală

Intrare digitală: 24 puncte, DC24V

Ieșire digitală: 16 puncte, ieșire releu (2A per point for resistive load)

On-board Analog I/O (no extra expansion module required)

Intrări analogice: 4 canale, 0-10V /4-20 mA

Analog Outputs: 2 canale, 0-10V

  1. Alimentare electrică: AC 100-240V
  2. Capacitatea programului: 20K pași; Data memory: 32K cuvinte
  3. Contor de mare viteză: 4-axă, 100 kHz; Ieșire impuls: 4-axă,100 kHz (supports servo positioning)
  4. Porturi de comunicație: Peripheral port (RS232) + USB programming port; expandable with RS485 and CP1W modules
  5. Capacitate de extindere: Max.7 units of CP1W expansion modules; compatible with CP1W analog, digital-I/O and temperature modules

⚠️ Notes for-EDU version

  1. Designed for laboratory training. OMRON does not provide industrial-site warranty. Use standard commercial model CP1H-XA40DR-A for industrial projects.
  2. Programs, CX-Programmer / CX-One software, wiring and expansion modules are fully interchangeable between EDU and commercial units; user programs can be directly downloaded to either unit.
  3. Compatibilitate software

Programming software: CX-Programmer (within CX-One software suite)

Not compatible with Sysmac-Studio: CP1H belongs to traditional CP-series, not the NJ/NX platform.

  1. Easily-confused Model Comparison
  2. CP1H-XA40DT-A-EDU: Ieșire tranzistor. Superior high-speed pulse performance, direct-drive for servo drives.
  3. CP1H-XA40DR-A-EDU: Ieșire releu. Suitable for contactors and indicator lamps. Limited relay mechanical life; not for high-frequency pulse switching.
  4. CP1H-Y20DT-D: DC power supply variant, no built-in analog I/O.
  5. Opțiuni de înlocuire

OMRON upgrade alternative: CP2E-N40DR-A (no on-board analog; add CP1W-MAD42 analog module separately)

Domestic compatible alternatives: Inovance H1U/H2U series, Xinje XD-series PLC.

  1. Inspection Checklist for Used / Training-grade-EDU Hardware
  2. Inspect relay outputs for contact burning or adhesion.
  3. Mandatory testing of built-in analog input & ieșire.
  4. Verify USB programming port and RS232 peripheral port communication.

4.-EDU units are not eligible for OMRON industrial warranty claims; for laboratory-use only.

OMRON CP1H-XA40DR-A-EDU

Hardware 100% equivalent to CP1H-XA40DR-A.-EDU = Educational training variant. Differences are limited to warranty and sales channel. I/O mapping, analog functions, communication and programs are fully interoperable.

  1. CIO I/O Memory Assignment (-EDU exactly the same)

I/O digitală

TipCanalBițiObservații
Intrare digitalăCIO 00000.00‑00.1112 points DC24V input
Intrare digitalăCIO 00101.00‑01.1112 points DC24V input; total 24 intrări
Ieșire digitalăCIO 100100.00‑100.078‑point relay output
Ieșire digitalăCIO 101101.00‑101.078‑point relay output; total 16 iesiri

Nota: DR relay-output models do NOT support hardware high-speed pulse output. Pulse positioning function is only available for DT transistor-output variants.

On-board Analog I/O Address (XA-specific hardware)

CanalFuncţie
200 CHIntrare analogică 0
201 CHIntrare analogică 1
202 CHIntrare analogică 2
203 CHIntrare analogică 3
210 CHIeșire analogică 0
211 CHIeșire analogică 1

Analog range options: 0-10V, 1-5V,-10-10V,4-20 mA. Power-cycle the PLC after parameter configuration for settings to take effect.

  1. Terminal & Ghid de cablare

2.1 Terminale de alimentare

L1 / L2(N): AC100-240V, 50/60 Hz

GR: Pământ protector, must be grounded

24V OUT: Auxiliary 24 VDC output from PLC (300 mA max) for sensor power; do not overload.

2.2 Intrare digitală (Sinking / Sourcing selectable)

COM: Input common terminal. Sinking input: connect COM to 0 V; Sourcing input: connect COM to 24 V.

Input terminals: 00-23 for DC24V signals.

2.3 Ieșire releu

Independent common-COM terminals for output groups. Max. 2 A per point for resistive loads. Free-wheeling diodes are recommended for inductive loads.

Avoid frequent ON/OFF switching; relay contacts have finite mechanical service life.

2.4 On-board Analog Wiring

4 × AI, 2 × AO. DIP-switch per AI channel: OFF = voltage input; ON = current input.

  1. Tensiune de intrare: Signal positive → VIN, signal negative → COM
  2. Intrare curentă (4-20 mA): Set DIP-switch ON, short-circuit VIN and IIN, feed signal to IIN, signal negative → COM
  3. Ieșire analogică (voltage-only): VOUT to load positive, COM to load negative. On-board AO supports voltage output only, no current output capability.

⚠️ Route analog cables separately, keep clear of power cables to minimize electromagnetic interference.

  1. Side-by-side Comparison: CP1H-XA40DR-A vs CP1H-XA40DR-A-EDU
ArticolCP1H‑XA40DR‑A (Industrial Version)CP1H‑XA40DR‑A‑EDU (Educational Version)
PCB hardware, I/O, analog circuits, firmwareIdenticIdentic
Programming softwareCX‑ProgrammerCX‑Programmer, programs fully transferable
Module de expansiuneAll CP1W compatibleAll CP1W compatible
Official WarrantyFull industrial warrantyNo industrial warranty; laboratory‑application only
Sales ChannelIndustrial automation channelEducational‑lab project channel
Nameplate MarkingCP1H‑XA40DR‑A‑EDU suffix printed on nameplate
Industrial‑site Deployment✅ Recomandat❌ Not advised for industrial field use

-Many-EDU units circulate in second-hand markets. Hardware may function properly, yet OMRON will reject warranty service requests.

  1. HS-Code Reference (Customs Declaration)

Commodity: Controler logic programabil (PLC)

Cod HS: 84714100 (Complete-system programmable controller)

For reference only. Confirm HS classification with your customs broker before actual declaration.

  1. Acceptance Test Procedure for Second-hand-EDU Training Units
  2. Power-on test: Apply AC100-240V. POWER LED lights normally, no error alarms. Check backup-battery condition; low battery will cause program loss.
  3. Digital Input test: Feed 24 VDC signal to every input point, monitor CIO0 & CIO1 bits via CX-Programmer to verify full response.
  4. Relay Output test: Force-ON CIO100 / CIO101 bits point-by-point; measure contact continuity; check for burned or stuck contacts.
  5. USB programming port: Verify program upload / download with CX-Programmer.
  6. RS232 peripheral port: Validate serial communication.
  7. Mandatory analog-I/O testing:

Modul de tensiune: Inject 0-10 V reference signal to each AI channel, monitor CH200-203 values.

AO test: Assign values to CH210 & CH211, measure output voltage at VOUT terminals.

Switch to current-input mode, validate 4-20 mA acquisition.

  1. Expansion bus test: Mount one CP1W expansion unit and confirm bus communication.
  2. Sourcing-Alternative Quick Reference
  3. OMRON upgrade replacement: CP2E-N40DR-A, no native analog; add CP1W-MAD42 analog module.
  4. Transistor-output variant for motion control: CP1H-XA40DT-A-EDU
  5. Alternative interne: Inovance H2U-40DR, Xinje XD3-40R-E
  6. Software & Documentare

Programming Tool: CX-Programmer (CX-One4.x); Sysmac-Studio is not supported.

Manual reference document No.: W450 (CP1H Operation Manual).