Complete order-part numbers: XCKM102C (Pg11 cable entry)、XCKM102H29 (M20×1.5 cable entry, commonly used in China)
Serie: Telemecanique XC-Standard metal-housing întrerupător de limită, actuator ZCK-D02 steel-roller plunger, întoarcere de primăvară
Codul modelului Explicația
XCKM: M = Zamak zinc-alloy metal housing, modular limit-switch body
102: Blocarea contactului: 1NO+1NC snap-action contacts with forced-opening safety NC contact; supplied with ZCK-D02 roller-plunger actuator
Sufixul C: Pg11 threaded cable entry; Suffix H29: M20×1.5 metric threaded cable entry (mainstream for domestic projects)
Specificații tehnice de bază
| Articol | Parametru |
| Configurare contact | 1 În mod normal, deschis (NO‑13‑14) +1 În mod normal, închis (NC‑21‑22), snap‑action with forced opening |
| Actuator | Top steel‑roller plunger, întoarcere de primăvară, bidirectional side actuation |
| Forța de acționare | Minimum operating force 12 N; Minimum forced‑opening force 36 N |
| Evaluări electrice | AC‑15 240V /3A; DC‑13 250V/0.27A; Max. 500 V |
| Terminale | Borne cu șuruburi, conductor cross‑section 0.34‑1.5 mm² |
| Clasa de protectie | IP66, IK05 |
| Viața mecanică | 20 million operations |
| Temperatura de operare | ‑25℃~+70℃ |
| Dimensiuni generale | 64×64×30 mm, greutate aprox. 0.255 kg |
| Cable Entries | 3 threaded ports; XCKM102C=Pg11; XCKM102H29=M20×1.5 |
Definiția terminalului
13-14: NO Normally-Open
21-22: NC Normally-Closed
⚠️ The NC contact features forced-opening function, designed for safety circuits; do not treat it as an ordinary micro-switch contact.
Aplicații tipice
Machine-tool hard overtravel limit, echipamente transportoare, lifting machinery, position detection for automation equipment. Suitable for dusty and splashing-water environments; metal housing provides impact resistance. Design modular: ZCK-D02 actuator can be replaced separately without changing the whole switch.
Înlocuire & Selecţie
- Original OEM replacement: XCKM102H29 (M20) / XCKM102C (Pg11)
- Domestic compatible alternatives: Metal-housing roller-plunger limit switches; verify: 1NO+1NC snap-action, IP66, mounting hole pitch 64 mm
- Same-series actuator exchange: Retain switch body, fit various ZCK-XX lever-type actuators.
Defecte comune & Depanare
- Niciun semnal: Check roller-plunger jamming / oboseala de primăvară; inspect contact burning; verify screw-terminal tightening torque.
- Semnal instabil: Reserve sufficient mechanical over-travel; avoid over-compressing plunger; actuating speed ≤0.5 m/s.
- Water ingress damage: Match cable gland to entry thread; do not force Pg11 gland onto M20 port.
Nota: XCKM102 consists of body plus actuator. Confirm cable-entry thread when ordering; XCKM102H29 is preferred for most Chinese field installations.
Application Scenarios of Schneider XCKM102 Steel-Roller-Plunger Limit Switch
Key features: Top steel-roller plunger, bidirectional side actuation, automatic spring return, 1NO+1NC snap-action contacts, forced-opening safety NC contact, IP66 metal housing. Designed for lateral cam-dog actuation, for position confirmation, hard overtravel limiting and safety interlocking.
- Machine-Tool Equipment
- Mașini-unelte CNC, mașini de frezat, strunguri, polizoare: Positive/negative hard overtravel protection for slides / work-tables to prevent collision; tool-change position feedback, tailstock position check, pallet clamping confirmation.
- Injection-molding machines, die-casting machines: Mold open-close position detection, mechanical safety-gate interlock; ejector-stroke limit.
- Press equipment: Slide travel limit, guard-door interlock; NC contact wired into safety circuit.
✅ Selection hint: Plunger requires lateral cam actuation. Cam-dog surface shall be smooth to prevent heavy impact damage to roller.
- Material-Handling & Echipamente de transport
- Belt, roller, transportoare cu lanț: Pallet/bin stop-position signal, limita de sfârșit de călătorie, stop-dog position feedback; sorting-mechanism position signal.
- Platforme de ridicare, palanele, stacker cranes: Upper/lower travel limits, fork extend/retract confirmation; over-travel prevention; NC contact for safety cut-off circuit.
- Depozite automatizate: Rail hard limit for shuttle cars, position confirmation.
- Ambalare & Printing Production Lines
- Mașini de ambalat, case sealers, etichetatoare: Cilindru / slide position detection, mechanism status feedback; roll-holder limit.
- Mașini de imprimat: Paper-pile lifting limit, pusher-mechanism position signal.
- Ridicare & Light Machinery
- Small overhead cranes, electric chain hoists: Trolley travel limit, lifting-tool position sensing (not for main hoist ultimate height limit — heavy-duty lever-head type is recommended for main hoist).
- Robots, gantry axes: Mechanical hard limit (physical backup beyond PLC soft-limit).
- Industrial Doors, Gates & Access Interlocks
- High-speed industrial doors, lifting gates: Full-open / full-closed position feedback; safety interlock.
- Machine-guard access doors, maintenance hatches: Door-closed confirmation interlock; stop equipment when door opens.
- Other Industrial Machinery
Utilaje textile: Slider limit for looms & aparate de cardare
Water-treatment & environmental equipment: Poartă / baffle position detection
Liniile de asamblare: Fixture-clamping position confirmation
Operating-Condition Compatibility
✅ Suitable for XCKM102
Lateral cam-dog pushes roller-plunger, linear reciprocating motion
Prăfuit / splashing-water ambient conditions requiring IP66
Safety circuits requiring forced-opening NC contact
Medium actuating force (≥12 N), immune to minor vibration false-triggering
❌ Not Suitable
- Direct vertical impact onto plunger (risk of internal-mechanism damage)
- Large-stroke pivoting actuation (use lever-head models e.g. XCK-M115)
- Repeated high-speed impact; maximum actuating speed ≤0.5 m/s.
Typical Wiring Practices
- Position-reached signal: Use 13-14 (NU). Contact closes when cam compresses plunger; status read by PLC.
- Hard safety-limit: Sârmă 21-22 (NC, forced-opening) in series within motor-control circuit. On over-travel impact, hardware directly cuts power, independent of PLC logic.
Complete Technical Specifications for Schneider XCKM102 Limit Switch
Serie: XC-Standard (Telemecanique); Actuator: ZCK-D02 steel-roller plunger, întoarcere de primăvară, bidirectional side actuation
Order-part variants:
XCKM102C: Pg11 cable entry
XCKM102H29: M20×1.5 metric cable entry (widely used in China)
- Specificatii mecanice
| Articol | Parametru |
| Actuator | Steel‑roller plunger, automatic spring return, bidirectional side actuation |
| Forța de operare minimă | 12 N |
| Minimum Forced‑Opening Force | 36 N (for safety NC contact) |
| Max. Permitted Operating Speed | 0.5 m/s, high‑speed impact not permitted |
| Min. Operating Speed | 0.01 m/min |
| Viața mecanică | 20 million operations |
| Materialul carcasei | Zamak zinc‑alloy |
| Dimensiuni generale | 64 × 64 × 30 mm |
| Greutate netă | 0.255 kg |
| Cable Entries | 3 threaded ports; C‑variant Pg11; H29‑variant M20×1.5 |
| Clasa de protectie | IP66; Impact resistance IK05 |
| Rezistenta la vibratii | 10‑500 Hz, 25 gn |
| Rezistenta la socuri | 50 gn, 11 Domnișoară |
- Specificații electrice
| Articol | Parametru |
| Configurare contact | 1NU(13-14)+1NC(21-22), snap‑action with forced‑opening NC contact |
| Curent termic convențional Ith | 10 A AC |
| AC‑15 Inductive Load | 240 V, 3 O (A300) |
| DC‑13 Inductive Load | 250 V, 0.27 O (Q300) |
| Tensiune nominală de izolație Ui | 500 V (Gradul de poluare 3) |
| Tensiune nominală de rezistență la impuls Uimp | 6 kV |
| Viața electrică (DC-13) | 5 million operations |
| Short‑Circuit Protection | 10 A gG fuse |
| Terminale | Screw‑clamp terminals, conductor: 0.34‑1.5 mm², accept two wires per terminal |
- Condiții de mediu
Temperatura de functionare: -25℃ ~ +70℃
Temperatura de depozitare: -40℃ ~ +70℃
Certificari: CCC, UL508, CSA; complies with IEC 60947-5-1, IEC 60204-1
- Definiția terminalului
13-14: NO Normally-Open (position-reached signal)
21-22: NC Normally-Closed (forced-opening, for hard-safety-limit circuits)
- Key Application Notes
- Designed for lateral cam-dog compression of roller-plunger. Vertical direct impact is not recommended; 30°-angled cam profile is preferred.
- Modular construction: ZCK-D02 actuator can be replaced separately without replacing complete switch unit.
- Confirm cable-entry thread at ordering: Prefer XCKM102H29 (M20×1,5) for new-build Chinese projects; XCKM102C for legacy Pg11 installations.
Operating Principle of Schneider XCKM102 Limit Switch
XCKM102 is a modular metal-housing mechanical limit switch, fitted with ZCK-D02 roller-plunger actuator. Principiul de bază: Mechanical force → plunger displacement → internal snap-action contact toggle → automatic spring return; NC contact implements mechanical forced-opening safety feature, compliant with IEC 60947-5-1.
- Mechanical Operating Sequence
- Free state (non-actuated)
Cam-dog does not contact roller-plunger; return spring holds plunger outward at home position.
Stare: 21-22 NC închis; 13-14 NU deschis.
- Actuated state (cam-dog compresses roller)
Moving-machine cam-dog laterally pushes steel roller and compresses plunger inward.
Once plunger travels past operating point, internal snap-action rocker mechanism triggers instantaneous contact state change; transition is abrupt, not gradual.
Snap-action benefit: Reliable make-break independent of cam-dog speed; eliminates contact chatter / bounce.
Actuated status: 21-22 NC deschis; 13-14 NU închis.
- Reset process
Cam-dog moves away, external force removed; return spring pushes plunger back to home position, contacts restore original state.
⚠️ Caution: Designed for lateral compression. Direct vertical pounding on plunger may destroy internal components.
- Forced-Opening Principle for Safety NC Contact 21-22 [Critic]
The 21-22 NC contact is not a standard micro-switch contact; it implements mechanical forced-opening construction:
When plunger is fully depressed, rigid mechanical linkage physically pries the NC contacts apart, not relying only on contact-spring force.
Even in case of contact welding / lipirea, mechanical linkage can forcibly separate contacts to break the circuit.
Prin urmare 21-22 NC is dedicated to hard-safety-limit and safety-interlock circuits, achieving hardware-level power cut-off independent of PLC software logic.
Never use NO contacts for safety circuits; NO contacts have no forced-opening capability.
- Electrical Logic Table
| Switch Status | 13-14 (NO Normally‑Open) | 21-22 (NC Forced‑Opening Normally‑Closed) |
| Non‑actuated (home) | Deschide | Închis |
| Cam‑dog actuated | Închis | Deschide |
| Cam‑dog retracted, reset | Deschide | Închis |
Two Typical Wiring Modes
- Position-feedback signal (PLC digital input): Use 13-14 NU; closure indicates target position reached.
- Hardware hard-overtravel protection: Series-connect 21-22 NC into contactor-control circuit. Overtravel impact opens switch and directly de-energizes control circuit to avoid machine damage.
- Modular Construction Breakdown
XCKM102 consists of three assemblies:
- Actuator: ZCK-D02 (roller-plunger, arc de întoarcere) receives external mechanical input.
- Blocarea contactului: Snap-action rocker-contact assembly performs circuit switching.
- Carcasa metalica: Provides mechanical mounting, environmental protection and wiring terminals.
Damaged actuator can be replaced separately with ZCK-D02; full-switch replacement is unnecessary.
- Fault-Mechanism Analysis
- Signal chatter / flickering: Cam-dog travel insufficient; plunger stays near transition threshold without full over-travel.
- Contacts fail to reset: Plunger jamming; return-spring fatigue or fracture.
- Safety-circuit loss: Mis-application of NO contact for safety function; or contact welding (only NC provides forced-opening anti-weld protection).
Contactor,întrerupător de circuit,senzor,Codificator,PLC,