Schneider GV2P32 Motor Circuit Breaker - Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Despre Contact |

 Schneider GV2P32 Motor Circuit Breaker - Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare

întrerupător de circuit/

Schneider GV2P32 Motor Circuit Breaker

The GV2P32 is a 3-pole thermal-magnetic motor circuit breaker (MPCB) from Schneider TeSys GV2 series. It features an adjustable current setting of 24-32A, compatible with 15kW @ 400V three-phase motors. Providing dual protection against overload and short circuit, with IP20 protection degree, it is widely applied in industrial motor control circuits. Cod model Explicație Cod ...

  • Detalii despre produs

The GV2P32 is a 3-pole thermal-magnetic motor circuit breaker (MPCB) from Schneider TeSys GV2 series. It features an adjustable current setting of 24-32A, compatible with 15kW @ 400V three-phase motors. Providing dual protection against overload and short circuit, with IP20 protection degree, it is widely applied in industrial motor control circuits.

  1. Codul modelului Explicația
Segment de codSensDescriere
GV2Seria de produseTeSys GV2 series motor circuit breakers for motor overload and short-circuit protection
PTip operațiuneRotary knob manual control, imported version (domestic equivalent: GV2PM series)
32Evaluare curentăAdjustable setting range: 24-32O, for motor circuits with rated current up to 32A

Definiție completă a modelului: GV2P32 = Schneider GV2 series, rotary knob type, 32A rated motor circuit breaker

  1. Specificații tehnice de bază
CategorieSpecificațiiObservații
Caracteristici generale
Tip de produs3-pole thermal-magnetic motor circuit breaker (MPCB)Conform IEC 60947-4-1
Interval de curent reglabil24-32O (reglabil)Thermal trip with ambient temperature compensation
Polonii3P (Trifazat)Designed for three-phase motor protection
Modul de operareRotary knob manual controlWith ON/OFF indicator and lockable function
Parametrii electrici
Tensiune nominală de funcționare230-690V și, 50/60HzSuitable for global industrial power grids
Puterea motorului compatibil15kW @ 400/415V, 50/60HzMaximum applicable power under standard operating conditions
Magnetic Trip Threshold12×In = 384A (Instant short-circuit protection)Fast disconnection upon short-circuit faults
Capacitatea de rupere a scurtcircuitului10kA @ 400V, 50HzMeets industrial standard requirements
Tip terminalBorne cu șuruburiApplicable copper wire cross-section: 1.5-25mm²
Fizic & Parametrii de mediu
Grad de protectieIP20Prevents finger access to live parts
Tip de montareSina DIN standard de 35 mmModular installation, economisind spațiu
Dimensiuni (L×A×D)45×85×95mmCompact design for distribution cabinets
Temperatura de operare-25℃ ~ +60℃Gamă largă de temperatură pentru medii industriale
CertificariCCC, UL, CSA, EAC, Marine Classification (DNV, GL, BV), ATEXMultiple certifications for global application
Informații de comandă
Manufacturer Part No.GV2P32Official Schneider model
Cod de comandă standardGV2P32Original imported version
  1. Full GV2P Series Model List
ModelInterval de curent reglabilPuterea motorului compatibil (400V)Curent de declanșare magnetic
GV2P010.16-0.25O0.06kW3.0O
GV2P020.25-0.4O0.12kW4.8O
GV2P030.4-0.63O0.25kW7.6O
GV2P040.63-1O0.37kW12O
GV2P051-1.6O0.75kW19O
GV2P061.6-2.5O1.1kW30O
GV2P072.5-4O1.5kW48O
GV2P084-6.3O3kW76O
GV2P096.3-10O4kW120O
GV2P1010-16O7.5kW190O
GV2P1413-18O11kW216O
GV2P1616-24O11kW288O
GV2P2020-32O15kW384O
GV2P3224-32O15kW384O
GV2P4032-40O18.5kW480O
  1. Modele de înlocuire & Comparația concurenților

4.1 Internal Schneider Replacements

Model originalModel de înlocuireDiferențeleScenarii de aplicare
GV2P32 (Importat)GV2PM32C (Intern)Different origin, minor certification differences; adâncime: 91mm (GV2P: 95mm)Domestic projects, cost-sensitive applications, CCC certification required
GV2P32GV2ME32 (Domestic push-button type)Push-button operation, identical electrical parametersApplications requiring push-button control, buget limitat
GV2P32GV3P32 (Upgraded series)Higher breaking capacity and enhanced functionsEnvironments with high short-circuit risk, advanced protection required

4.2 Comparație între concurenți între mărci

MarcaModelInterval de curentPoloniiMagnetic Trip RatioPrincipalele diferențe
SchneiderGV2P3224-32O3P12×ÎnMultiple certifications including marine approval, IP20
ABBMS325-3224-32O3P12×ÎnCapacitate de rupere: 15cel, larger dimensions
Siemens3RV2031-4KA1024-32O3P13×ÎnOptional electronic trip, pret mai mare
EatonPKZM0-3224-32O3P12×ÎnSpring terminals for easy installation
ChintNM1-63S/330025-32O3P10×ÎnAvantaj de cost, alternativă domestică
  1. Medii de aplicație & Cazuri tipice

5.1 Aplicații recomandate

Controlul motorului industrial: Main circuit protection for three-phase motors such as pumps, fani, compresoare și transportoare

Echipament OEM: Supporting machine tools, utilaje de ambalare, printing machines and textile machinery

Sisteme electrice de clădire: Protection for critical motors including air conditioning units, fire water pumps and drainage pumps

Marin & Offshore Engineering: Compliant with marine classification standards for ship power systems

Hazardous Areas: ATEX certified for motor protection in non-explosion-proof zones

5.2 Aplicații nerecomandate

Single-phase Motors: 3-pole design not suitable for single-phase circuit protection

Frequent Start-Stop Operations: Mai mult decât 10 cycles per hour will shorten service life

Altitudine mare (>2000m): Derating required (10% reduction per 1000m rise)

Severe Vibration Environments: Extra reinforcement needed to avoid false tripping

Corrosive Environments: IP20 protection is insufficient; additional enclosure is required

5.3 Cazuri tipice de aplicare

Caz 1: Water Treatment Plant Pump Protection

Echipamente: 3 sets of 15kW submersible three-phase pumps (400V)

Configurare: GV2P32 + LC1D32 Contactor + LRD3322 Thermal Overload Relay (protectie redundanta)

Rezultat: Prevented 3 motor overload faults and 1 short-circuit fault, prelungirea duratei de viață a echipamentelor prin 2 ani

Caz 2: Conveyor System in Automobile Manufacturing Plant

Echipamente: 12 conveyor lines each equipped with 15kW motor

Configurare: GV2P32 linked with Schneider PLC

Caracteristici: Rotary knob enables quick on-site reset and reduces downtime

  1. Depanare & Maintenance Manual

6.1 Defecte comune & Soluții

Fenomen de eroareCauze posibileSoluții
Declanșări termice frecvente1. Suprasarcina motorului1. Check motor load and eliminate mechanical jamming
2. Improper low current setting2. Set current to 1.1 times motor Full Load Current (FLA)
3. Temperatura ambientală excesiv de ridicată3. Îmbunătățiți ventilația și reduceți temperatura ambiantă
4. Loose terminals causing overheating4. Inspect and tighten terminals
Instant magnetic tripping1. Circuit short circuit1. Power off and test circuit insulation
2. Damaged motor winding insulation2. Measure winding resistance and replace faulty motor
3. Arc short circuit inside contactor3. Inspect contactor contacts and replace if necessary
Neînchidere1. Tripping mechanism not reset1. Turn knob to OFF position then re-close
2. Damaged rotary knob2. Check knob linkage and replace damaged parts
3. Internal mechanical failure3. Arrange professional maintenance or replace the breaker
Nicio ieșire după închidere1. Burned internal contacts1. Power off, inspect main contacts and replace defective unit
2. Cablaj incorect2. Verify wiring to ensure correct three-phase connection
3. Faulty tripping mechanism3. Check tripping mechanism and replace if needed

6.2 Maintenance Procedures

  1. Inspecție zilnică (Săptămânal)

Check knob position and status indication

Look for abnormal heat, odor or noise

Confirm all terminals are tightly connected

  1. Întreținere de rutină (Fiecare 6 Luni)

Power off and remove dust with dry compressed air

Inspect main contacts for burning and oxidation

Test tripping function by simulating overload and short circuit conditions

  1. Întreținere anuală

Check lubrication of internal mechanical components

Verify accuracy of current setting

Retighten all electrical connections

6.3 Quick Diagnosis Tips

Thermal trip? Check load and current setting.

Magnetic trip? Locate short circuit and test insulation.

Fail to close? Reset first; replace for mechanical faults.

Fără ieșire? Inspect contacts and wiring.

  1. Selecţie & Ghid de instalare

7.1 Reguli de selecție

Potrivire curentă: Motor FLA must fall within 24-32A; recommended setting: FLA × 1.1

Potrivirea puterii: Standard solution for 15kW @ 400V three-phase motors

Protection Coordination: Use with contactors and fuses to ensure selective protection

Ambient Derating: Derate 1% per ℃ above 40℃

7.2 Note de instalare

Direcția de montare: Instalare verticală (allowable deviation: ±15°) for normal tripping operation

Clearance: Reserve 10mm space on left & right sides, 20mm on top & bottom for heat dissipation

Standard de cablare: Copper wire with cross-section 1.5-25mm²; cuplul de strângere: 6-8Nm

Locking Function: Padlock can be fitted to prevent accidental operation, complying with safety regulations

  1. Production Status & Soluții de upgrade

Current Status of GV2P32: In production, no discontinuation plan (as of June 2026)

Upgrade & Opțiuni de înlocuire:

  1. Upgrade funcțional: GV3P32 (higher breaking capacity and extra protection functions)
  2. Alternativă internă: GV2PM32C (lower cost with equivalent performance)
  3. Intelligent Upgrade: TeSys T series (with communication for remote monitoring)

Prev:

Lasă un răspuns

Lăsaţi un mesaj