ABB F204B63-2CSF204592R1630 - Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Despre Contact |

ABB F204B63-2CSF204592R1630 - Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare

întrerupător de circuit/

ABB F204B63-2CSF204592R1630

This is a ABB F200 Series 4-pole Type B Residual Current Circuit Breaker (RCCB) with a rated current of 63A and a rated residual operating current of 30mA. This model is obsolete. The original manufacturer replacement part number is 2CSF204568R1630 (F204B-63/0.03-4TE). It is designed for industrial applications equipped with frequency converters, UPS and other devices, ...

  • Detalii despre produs

Acesta este un ABB F200 Series 4-pole Type B Întrerupător de curent rezidual (RCCB) with a rated current of 63A and a rated residual operating current of 30mA. This model is obsolete. The original manufacturer replacement part number is 2CSF204568R1630 (F204B-63/0.03-4TE). It is designed for industrial applications equipped with frequency converters, UPS and other devices, and provides protection against smooth DC leakage current.

  1. Codul modelului Explicația
Segmentul de modelDefiniţieDescriere detaliată
F204Model de bazăF200 Series, 4-pole residual current circuit breaker
BResidual Current TypeTip B, capable of detecting AC, pulsating DC and smooth DC residual current (0-1000Hz)
63Curent nominal de funcționare63O, continuous current rating
0.03Curent de funcționare rezidual nominal0.03A = 30mA, high-sensitivity protection against direct human contact
2CSF204592R1630Cod de comandăUnique official ABB identification code for purchasing and traceability
4THETip de montareStandard DIN rail mounting with 4-pole terminals (marked on partial versions)
  1. Specificatii tehnice principale
CategorieDate tehniceObservații
Caracteristici de bază
Tip de produsÎntrerupător de curent rezidual (RCCB)No overload or short-circuit protection; must be used with MCB
SerieSystem pro M compact® F200ABB modular power distribution product line
Polonii4P (L1, L2, L3, N)Protection for 3-phase 4-wire systems
Tensiune nominală400V și (50/60Hz)Gama de tensiune de operare: 380-415V
Curent nominal (În)63OConform IEC/EN 61008-1
Curent de funcționare rezidual nominal (IΔn)30mAInstantaneous type (no time delay)
Residual Current TypeTip BComprehensive protection against AC, pulsating DC and smooth DC leakage current
Parametri de performanță
Capacitate de rupere (IΔm)3celBreaking capacity under rated conditions
Timp de funcționare≤0.04s @ IΔn=30mAMeets requirements for rapid personal safety protection
Rated Residual Non-operating Current (IΔnr)15mANo tripping below this value to avoid nuisance tripping
Butonul de testareÎncorporatFor regular functional testing
Caracteristici fizice
Dimensiuni (L × H × D)70mm × 85mm × 60mmDesign modular standard, occupies 4 module units
Montare35mm șină DINConform EN 50022
Tip terminalBi-directional cylindrical terminalsFacilitates cable connection and enhances safety
GreutateAproximativ. 360gWeight per unit
Mediu & Certificari
Temperatura de operare-25°C ~ +55°CPerformance may be affected beyond this range
Temperatura de depozitare-40°C ~ +85°C
Umiditate5% ~ 95% (necondens)
Protecție la intrareIP20Rezistent la degete, not suitable for outdoor use
CertificariIEC/EN 61008-1, IEC/EN 61008-2-1Certificat CE, complies with international safety standards
Starea ciclului de viață
StareÎnvechitStock still available via some distributors
Discontinued DateJun-24Official record
  1. Lista completă a modelelor (F204 Type B)
ModelCod de comandăCurent nominalRated Residual CurrentCaracteristici
F204 B-25/0.032CSF204592R125025O30mA4-pole Type B, basic model
F204 B-40/0.032CSF204592R140040O30mA4-pole Type B, medium current
F204 B-63/0.032CSF204592R163063O30mA4-pole Type B, standard industrial model
F204 B-63/0.12CSF204592R263063O100mA4-pole Type B, higher sensitivity
F204 B-63/0.32CSF204592R363063O300mA4-pole Type B, protectia echipamentului
F204 B-63/0.52CSF204592R463063O500mA4-pole Type B, system protection
F204 B-80/0.032CSF204592R180080O30mA4-pole Type B, curent mare
F204 B-100/0.032CSF204592R1100100O30mA4-pole Type B, extra high current
F204 B-125/0.032CSF204592R1125125O30mA4-pole Type B, maximum current
F204 B-63/0.03-4TE2CSF204568R163063O30mAReplacement model, 4-pole Type B, standard terminals
  1. Soluții de înlocuire & Echivalente între mărci

4.1 Original Manufacturer Replacements

Model originalModel de înlocuireMotivul înlocuiriiCompatibilitate
F204 B-63/0.03 (2CSF204592R1630)F204 B-63/0.03-4TE (2CSF204568R1630)Product upgrade with optimized terminal designComplet compatibil, înlocuire directă
DDA204 B-63/0.03 AP-R (2CSB204592R1630)FI-Block series, integrated designIdentical mounting dimensions and functions

4.2 Cross-Brand Compatible Replacements

MarcaModelTechnical Matching RateObservații
SchneideriC60H RCCB 4P 63A 30mA Type B95%Dimensionally compatible, performanță echivalentă
Siemens5SU1356-6KK6390%Slight difference in tripping characteristics
Legrand4102 63 03 B90%Different wiring terminals
Chint (China)NXBLE-400/4P 63A 30mA Type B85%Cost-effective with complete certifications
  1. Medii de aplicație & Cazuri tipice

5.1 Aplicații recomandate

Sisteme de automatizare industriale: Frequency converters, servo drives, PLC cabinets; protects against smooth DC leakage current.

Echipament medical: Operating rooms, ICU devices; provides top-level leakage protection.

Centre de date: UPS systems, server cabinets; prevents nuisance tripping caused by power fluctuation.

Energie regenerabilă: PV inverters, sisteme de stocare a energiei; protects DC side leakage.

Clădiri Comerciale: Kitchen equipment, central air conditioning, elevator control systems; protection for 3-phase loads.

5.2 Aplicații nerecomandate

Pure residential single-phase loads: Type B is overqualified; Type AC is sufficient.

Outdoor humid environments: IP20 rating is inadequate; additional enclosure protection required.

Explosive hazardous areas: Explosion-proof products must be used.

Applications requiring overload/short-circuit protection: This unit only provides leakage protection and shall be used together with MCB.

5.3 Cazuri tipice de aplicare

Caz 1: Automotive Manufacturing Workshop

Echipamente: Robotic welding systems, converter-driven production lines

Issue: Frequent nuisance tripping of conventional Type AC RCCBs affected production.

Soluţie: Install F204 B-63/0.03 to protect against smooth DC leakage generated by converters.

Rezultat: Nuisance tripping rate reduced by 90%, production efficiency improved by 15%.

Caz 2: Hospital Operating Room

Echipamente: Anesthesia machines, patient monitors, surgical lights

Requirements: Highest safety level, zero nuisance tripping and fast response.

Soluţie: Adopt F204 B-63/0.03 combined with S204-B63 MCB.

Rezultat: Complies with medical equipment safety standards and ensures operational safety.

  1. Depanare & Maintenance Manual

6.1 Defecte comune & Soluții

Fenomen de eroareCauze posibilePași de depanare
Deplasări frecvente1. Actual circuit leakage1. Test circuit insulation with megohmmeter after power off
2. DC leakage from loads2. Verify if loads require Type B RCCB
3. Product aging3. Check production date; replace if service life exceeds 10 ani
4. Borne de cablare slăbite4. Retighten wiring terminals
Failure to trip1. Buton de testare deteriorat1. Replace test button assembly
2. Internal trip mechanism fault2. Send for repair or replace the unit
3. Cablaj greșit (neutral wire disconnected)3. Check wiring and ensure neutral wire is properly connected
Cannot be reset1. Mechanical lock failure1. Manually reset after power off; replace if failed
2. Persistent leakage2. Eliminate leakage fault before resetting
3. Temperatura ambientală excesiv de ridicată3. Îmbunătățiți ventilația și reduceți temperatura ambiantă
Indicator luminos stins1. Damaged indicator lamp1. Replace indicator lamp
2. Internal circuit fault2. Send for repair or replace the unit

6.2 Maintenance Procedures

  1. Routine Inspection (Lunar)

Visually inspect for damage or discoloration.

Press test button to confirm normal tripping and reset.

Check terminals for looseness and overheating marks.

  1. Întreținere periodică (Anual)

Clean unit surface with dry soft cloth after power cut.

Check firmness of DIN rail mounting.

Measure insulation resistance (≥1MΩ).

Record test results.

  1. Replacement Cycle

Normal operating conditions: 10 ani

Medii dure (temperatură ridicată / umiditate ridicată): 5~7 years

Frequent tripping conditions: 3~5 years

6.3 Quick Diagnosis Tips

Type B RCCB handles DC leakage well.

Check wiring first for frequent tripping; load type matters most.

Replace unit immediately if test button malfunctions.

Power off and clear faults before resetting.

Replace after 10 years for reliable safety.

  1. Ghid de selecție
  2. Residual Current Type Selection: Choose Type B for systems with converters, UPS or medical devices; Type AC for general lighting and sockets; Type A for pulsating DC loads.
  3. Rated Current Selection: Curent nominal ≥ 1.2 times total load current. 63A is suitable for most industrial control cabinets.
  4. Residual Current Rating Selection: 30mA pentru protectia personala; 100~300mA for equipment protection; 500mA~1A for system protection.
  5. Selectarea stâlpilor: 2P for single-phase systems; 3P for 3-phase 3-wire systems; 4P (with neutral wire) for 3-phase 4-wire systems.
  6. Replacement Principle: Prioritize upgraded models from the same series for obsolete products to guarantee identical dimensions and performance.

Prev:

Lasă un răspuns

Lăsaţi un mesaj