Întrerupător Schneider Marine-grade 24338 - Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Despre Contact |

 Întrerupător Schneider Marine-grade 24338 - Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare

întrerupător de circuit/

Întrerupător Schneider Marine-grade 24338

Full Range of Marine Classification Society Certifications: Approved by major global marine classification societies, complying with regulatory requirements for various vessels and offshore engineering equipment. Gamă largă de temperatură de funcționare: -30°C până la +60°C, suitable for extreme temperature variations in marine environments. Model Code Explanation Segment Code Description Product Range C60 Miniature Circuit Breaker of Multi9 series ...

  • Detalii despre produs

Full Range of Marine Classification Society Certifications: Approved by major global marine classification societies, complying with regulatory requirements for various vessels and offshore engineering equipment.

Gamă largă de temperatură de funcționare: -30°C până la +60°C, suitable for extreme temperature variations in marine environments.

  1. Codul modelului Explicația
SegmentCodDescriere
Product RangeC60Întrerupător în miniatură of Multi9 series
Capacitate de rupereNCapacitate de rupere standard (10cel, 400V și)
Numărul de poli2P2 stâlpi (2 protected poles)
Curent nominal20OCurent nominal de funcționare: 20 Amperi
Curba de deplasareCcurba C (Trips at 8~12 times rated current, for combined lighting and motor loads)
Număr de ordine24338Original standard order number of Schneider (equivalent to M9F11220)

Model complet: C60N 2P C20A (Official Standard Model)

Număr de ordine: 24338 (M9F11220)

  1. Specificatii tehnice principale
Categoria parametrilorSpecificații detaliate
Parametrii de bază2-pole miniature circuit breaker, C-type trip curve, rated current 20A
Tensiune nominalăAC: 400V (50/60Hz); DC: 125V
Capacitate de rupere10kA @ 400V AC (conform cu IEC 60947-2)
Trip Characteristiccurba C: 8.2In ±20% (In=20A, tripping range: 164~200A)
Rezistenta mecanica20,000 cicluri de operare
Rezistenta electrica10,000 operating cycles at rated current
Condiții de mediuTemperatură: -30°C ~ +60°C; Umiditate: ≤95% (necondens)
Montare35mm Montare pe șină DIN (conform EN 60715)
Dimensiuni & GreutateÎnălţime: 85mm; Lăţime: 45mm; Adâncime: 60mm; Greutate: aproximativ. 180g
Grad de protectieIP20 (conform cu IEC 60529)
Marine CertificationsCertified by 9 major classification societies including ABS, BV, DNV, GL, LRS, RINA, CCS, KRS
Standard ApprovalsIEC 60947-2, GB 14048.2, CE, CCC, etc.
  1. Marine Features & Scenarii de aplicare

3.1 Core Advantages for Marine Use

Full Marine Classification Certifications: Complies with standards of mainstream global marine classification societies for vessels and offshore facilities.

Adaptare largă la temperatură: Operates stably from -30°C to +60°C to cope with harsh marine temperature conditions.

Vibrație & Rezistenta la socuri: Conform IEC 60068-2-6 (Vibrație) și IEC 60068-2-27 (Şoc), applicable to rough working conditions during vessel navigation.

Corrosion Resistance: Special salt-fog resistant housing material extends service life in marine environments.

3.2 Scenarii aplicabile

Ship Power Systems: Protection for main switchboards, emergency switchboards, lighting and ventilation systems.

Offshore Platforms: Power distribution and protection for drilling platforms, offshore wind farms, FPSO and other facilities.

Marine Auxiliary Equipment: Control circuit protection for pumps, compresoare, fani, navigation equipment, etc.

Yachts & Small Vessels: Meets safety standards for recreational marine craft.

3.3 Scenarii nerecomandate

High Short-circuit Current Environment: Locations with short-circuit current exceeding 10kA (C60H series with 15kA breaking capacity is recommended).

High-voltage DC Systems: DC circuits over 125V (special DC circuit breakers required).

Frequent Cycling Circuits: Operations over 10 cycles per minute (use contactors with protective devices instead).

  1. Înlocuire & Soluții de upgrade

4.1 Original Schneider Replacements

Model originalModel de înlocuireMotivul înlocuiriiCompatibilitate
24338 (C60N 2P C20A)A9F44220 (iC60N 2P C20A)Upgraded Acti9 series, breaking capacity increased to 15kAIdentical mounting dimensions, înlocuire directă
24338 (C60N 2P C20A)M9F11220 (C60N 2P C20A)Official original model, fully identical to 24338100% compatibil
24338 (C60N 2P C20A)C60H 2P C20ABreaking capacity upgraded to 15kA for severe working conditionsIdentical mounting dimensions, enhanced breaking performance

4.2 Înlocuiri între mărci

MarcaModel de înlocuirePrincipalele diferențeApplicability
ABBS202-C2010kA capacitate de rupere, curba C, 2P 20ASame mounting size, înlocuire directă
Siemens5SY6220-7CC10kA capacitate de rupere, curba C, 2P 20ASlight difference in auxiliary functions, consistent basic protection
ChintDZ47-63 2P C20Domestic alternative with cost advantage, 6kA capacitate de rupereFor non-critical marine equipment
  1. Depanare & Ghid de întreținere

5.1 Diagnosticarea defecțiunilor comune

Fenomen de eroareCauze posibileSoluții
Deplasări frecvente1. Sarcină supraîncărcată; 2. Circuit short circuit; 3. Mismatched trip curve1. Check if load current exceeds rated value; 2. Inspect circuit insulation; 3. Verify suitability of C-curve for the load
Failure to trip1. Damaged tripping mechanism; 2. Current below trip threshold; 3. Cablaj incorect1. Inspect mechanical condition of tripping mechanism; 2. Measure actual operating current; 3. Confirm correct wiring (line in, load out)
Supraîncălzire severă1. Terminale libere; 2. Contacte oxidate; 3. Exces de temperatură ambientală1. Retighten wiring terminals; 2. Curățați contactele; 3. Improve ventilation and heat dissipation
Blocaj mecanic1. Foreign object ingress; 2. Worn operating mechanism; 3. Loose parts caused by vibration1. Power off and remove foreign objects; 2. Inspect operating mechanism; 3. Reinforce mounting fixtures

5.2 Maintenance Recommendations for Marine Environments

Articol de întreținereCicluOperațiunea
Inspecție vizualăLunarCheck for salt-fog corrosion, cracks and loose components
Insulation Resistance TestTrimestrialUse megohmmeter to test insulation resistance (value shall be higher than 1MΩ)
Contactați InspecțiaSemianualCheck contacts for ablation and oxidation; measure contact resistance
Test de funcționareAnualSimulate overload and short circuit to verify normal tripping performance
CuratenieAnualRemove internal dust with dry compressed air; avoid chemical detergents
  1. Ghid de selecție & Conformitatea transportului aerian

Mnemonic for Selection

C60N two-pole, twenty ampere C-curve,

Nine marine approvals, ten kiloamp breaking,

Replace with iC60 for higher capacity,

Safe for marine use, DIN rail mount ready.

Conformitatea transportului aerian

Clasificarea transporturilor: Mărfuri nepericuloase. No built-in lithium batteries or supercapacitors, compliant with IATA regulations.

Packaging Requirement: Individual packaging to prevent damage from vibration during transit. Original moisture-proof packaging is recommended.

Documente de certificare: Carry copies of marine classification certificates for customs and inspection.

Full Specification Comparison Table for Schneider C60 Series Marine Miniature Circuit Breakers

This table provides a detailed comparison of core specifications for C60N / C60H marine series (inclusiv 24338: C60N 2P C20A), covering commonly used pole counts (1P/2P/3P/4P) and current ratings (16A/20A/25A/32A/40A/50A/63A) for bulk selection.

  1. General Specification List (Marine C-curve)
ModelNumăr de ordinePoloniiCurent nominalCapacitate de rupereLăţimeGreutateMarine CertificationsModel de înlocuire (iC60 Series)
C60N 1P C16AM9F111161P16O10cel18mm90g9 Classification SocietiesA9F74116
C60N 1P C20AM9F111201P20O10cel18mm90g9 Classification SocietiesA9F74120
C60N 1P C25AM9F111251P25O10cel18mm90g9 Classification SocietiesA9F74125
C60N 1P C32AM9F111321P32O10cel18mm90g9 Classification SocietiesA9F74132
C60N 2P C16AM9F112162P16O10cel36mm180g9 Classification SocietiesA9F74216
C60N 2P C20A24338 / M9F112202P20O10cel36mm180g9 Classification SocietiesA9F74220
C60N 2P C25AM9F112252P25O10cel36mm180g9 Classification SocietiesA9F74225
C60N 2P C32AM9F112322P32O10cel36mm180g9 Classification SocietiesA9F74232
C60N 3P C16AM9F113163P16O10cel54mm270g9 Classification SocietiesA9F74316
C60N 3P C20AM9F113203P20O10cel54mm270g9 Classification SocietiesA9F74320
C60N 3P C25AM9F113253P25O10cel54mm270g9 Classification SocietiesA9F74325
C60N 3P C32AM9F113323P32O10cel54mm270g9 Classification SocietiesA9F74332
C60N 4P C16AM9F114164P16O10cel72mm360g9 Classification SocietiesA9F74416
C60N 4P C20AM9F114204P20O10cel72mm360g9 Classification SocietiesA9F74420
C60H 2P C20AM9F142202P20O15cel36mm180g9 Classification SocietiesA9F84220
C60H 3P C20AM9F143203P20O15cel54mm270g9 Classification SocietiesA9F84320
  1. Comparison of Breaking Capacity & Trip Characteristics
SerieCapacitate de rupereCurba de deplasareScenarii de aplicareMax Rated CurrentNivelul prețurilor
C60N10kA @ 400V ACB / C / DGeneral ship power systems, combined lighting & sarcinile motorului63OStandard
C60H15kA @ 400V ACB / C / DShip systems with high short-circuit current, de ex. main switchboards63OStandard +15%
iC60N15kA @ 400V ACB / C / DUpgraded replacement for C60N with improved performance63OStandard +20%
iC60H30kA @ 400V ACB / C / DHigh-standard marine systems and offshore platforms63OStandard +30%

Trip Curve Description

B-curve: Trips at 3~5 times rated current, for pure resistive loads (iluminat)

curba C: Trips at 8~12 times rated current, for combined lighting and motor loads (cel mai utilizat)

D-curve: Trips at 12~14 times rated current, for inductive loads such as motors and transformers

  1. Detailed Comparison between 24338 (C60N 2P C20A) & Modele comune

3.1 Same Poles, Different Current Ratings (2P)

ModelCurent nominalTrip Current RangeApplicable LoadsDifference vs 24338
C60N 2P C16A16O128~192AIluminat & motor loads below 16A20% lower current, more sensitive protection
C60N 2P C20A (24338)20O164~200ACombined loads below 20AConfigurație standard
C60N 2P C25A25O205~300ACombined loads of 20~25A25% higher current, larger load capacity
C60N 2P C32A32O262~384ACombined loads of 25~32A60% higher current, for higher-power equipment

3.2 Same Current, Different Pole Counts (20O)

ModelPoloniiLăţimeScenarii de aplicareDifference vs 24338
C60N 1P C20A1P18mmSingle-phase lighting & socket circuitsHalf width, only live pole protected
C60N 2P C20A (24338)2P36mmSingle-phase motors & echipamente, line and neutral disconnected simultaneouslyConfigurație standard, protecţie cuprinzătoare
C60N 3P C20A3P54mmMotoare trifazate & echipamente, 380sisteme V50% wider, pentru circuite trifazate
C60N 4P C20A4P72mmThree-phase four-wire systems with neutral protectionDouble width, for circuits requiring neutral pole protection

3.3 Aceeași specificație, Different Breaking Capacity (2P 20A C)

ModelCapacitate de rupereMediul de aplicarePrice DifferenceDifference vs 24338
C60N 2P C20A (24338)10celGeneral ship systemsStandardConfigurație standard
C60H 2P C20A15celSystems with high short-circuit current15%50% capacitate de rupere mai mare
iC60N 2P C20A15celUpgraded replacement solution20%New generation product with longer service life
iC60H 2P C20A30celOffshore engineering platforms30%200% capacitate de rupere mai mare
  1. Selection Reference Table for Marine Applications
Tip de încărcareRecommended Trip CurveRecommended Breaking CapacityRecommended PolesReference Current
Ship Lighting SystemBC60N (10cel)1P / 2P6O / 10O / 16O
Fani & Pump MotorsCC60N (10cel)3P16O / 20O / 25O
Compresoare & Air-conditioning UnitsCC60H (15cel)3P25O / 32O / 40O
Navigation & Echipamente de comunicareBC60N (10cel)1P / 2P6O / 10O
Branches of Main SwitchboardCC60H (15cel)3P / 4P32O / 40O / 50O
Emergency Power SystemDC60H (15cel)3P40O / 50O / 63O
  1. Notes for Bulk Selection
  2. Marine Certifications: All C60 marine models are certified by 9 major classification societies including ABS, BV, DNV, GL, LRS, RINA, CCS and KRS, available for global use.
  3. Compatibilitate de montare

All models adopt 35mm DIN rail mounting (conform EN 60715).

Width varies by pole count: 1P=18mm, 2P=36mm, 3P=54mm, 4P=72mm.

Uniform dimensions: Height 85mm, Depth 60mm.

  1. Replacement Strategy

Short-term replacement: Prioritize identical models from the same series (de ex. 24338 = M9F11220).

Long-term upgrade: Choose iC60N series (de ex. A9F74220 for 24338) with breaking capacity upgraded to 15kA.

Severe working conditions: Select C60H / iC60H series with 15~30kA breaking capacity.

  1. Adaptabilitate la mediu

Temperatura de functionare: -30°C ~ +60°C, suitable for extreme marine environments.

Vibrație & shock resistance: Conform IEC 60068-2-6 și IEC 60068-2-27.

Design rezistent la ceata salina: Special housing material extends service life in marine conditions.

  1. Selection Mnemonic for C60 Marine Series

Marine C60N holds nine approvals,

Two-pole 20A with C-curve set,

iC60 upgrades breaking power,

Match poles and current for your load hour,

Wide temp and anti-vibration, ideal for marine power.

Prev:

Următorul:

Lasă un răspuns

Lăsaţi un mesaj