Ventilator cu filtru Schneider NSYCVF165M230PF

Model Code Definition Breakdown of NSYCVF165M230PF Code Segment Meaning Description NSY Product series prefix General mark for Schneider ClimaSys cabinet cooling products CV Sub-series ClimaSys CV series standard cabinet filter fan F Product type Fan 165 Air flow rate Rated airflow 165m鲁/h at 50Hz, 193m鲁/h at 60Hz M Mounting type Side mounting on cabinet 230 ...

  • Detalii despre produs

Definiția codului modelului

Breakdown of NSYCVF165M230PF

Segment de codSensDescriere
NSYProduct series prefixGeneral mark for Schneider ClimaSys cabinet cooling products
CVSub-serieClimaSys CV series standard cabinet filter fan
FTip de produsVentilator
165Air flow rateRated airflow 165m鲁/h at 50Hz, 193m鲁/h at 60Hz
MTip de montareSide mounting on cabinet
230Tensiune nominală230V și
PProtection configurationEquipped with pre-filter
FAir outlet configurationFitted with front grille
  1. Parametrii de specificație de bază
CategorieTechnical IndexObservații
Parametrii de bază
Tip de produsCabinet Filter FanClimaSys CV series, IP54 protection
Air Flow165m³/h (50Hz) / 193m³/h (60Hz)Measured with standard G2 filter
Gama de tensiune175~253V ACCompatible with most 230V power grids worldwide
Tensiune nominală230V 50/60HzDual frequency compatibility
Parametrii electrici
Putere16.3W (50Hz) / 14.3W (60Hz)High energy efficiency
Actual0.12O (50Hz) / 0.94O (60Hz)Low power consumption design
ConexiuneFaston terminal + power cableInstalare ușoară
Physical Parameters
External Dimension268×248×104mmHeight×Width×Depth
Cutout Size223×223mmStandard cabinet mounting hole
MaterialAir outlet grille: ASA+PC thermoplasticAnti-aging, grey RAL 7035
Greutate1.14kgStable installation, low resonance
Parametri de performanță
Clasa de protectieIP54Dustproof and splashproof, suitable for outdoor cabinets
Bearing TypeBall bearingDurată lungă de viață, zgomot redus
Noise Level50~51dBQuiet operation, applicable near office areas
Max Static Pressure50Pa (0m³/h)Resists certain air resistance
Parametrii de mediu
Temperatura de operare-20℃~60℃Gamă largă de temperatură pentru medii dure
Temperatura de depozitare-40℃~70℃Reliable transportation and storage
CertificareREACH, RoHSCompliant with environmental standards
  1. Lista completă a modelelor din seria
ModelAir Flow(m³/h)VoltajConfigurareCutout Size(mm)External Size(mm)
NSYCVF38M230PF39230V șiGrille + Filter117×117137×137×85
NSYCVF54M230PF54230V șiGrille + Filter148×148170×170×92
NSYCVF85M230PF85230V șiGrille + Filter170×170190×190×95
NSYCVF165M115PF165/193115V șiGrille + Filter223×223268×248×104
NSYCVF165M230PF165/193230V șiGrille + Filter223×223268×248×104
NSYCVF165M24DPF165/19324În DCGrille + Filter223×223268×248×104
NSYCVF300M230PF300/350230V șiGrille + Filter262×262300×300×110
NSYCVF550M230PF550/650230V șiGrille + Filter336×336380×380×120
NSYCVF850M230PF838/980230V șiGrille + Filter400×400450×450×130
NSYCVF850M400PF838/980400V șiGrille + Filter400×400450×450×130
  1. Cross-brand Replacement Comparison
MarcaModelAir Flow(m³/h)VoltajClasa de protectieCutout Size(mm)Replacement Advantages
Rittal323920074/87230V șiIP54148×148Tool-free quick installation
Rittal3241700160/190230V șiIP54223×223High-efficiency energy saving series
StegoFK 66230165/193230V șiIP54223×223Integrated temperature control, intelligent start-stop
Pfannenberg1041230160/190230V șiIP54223×223Long filter service life, low maintenance frequency
RS PRO130-853165/193115V șiIP54223×223Eficient din punct de vedere al costurilor, sufficient stock
  1. Depanarea defecțiunilor comune & Întreţinere
Fenomen de eroareCauze posibileInspection StepsMaintenance Solution
Fan not running1. Power disconnected1. Test power voltage1. Reconnect power supply
2. Motor burnout2. Check motor winding resistance2. Replace identical motor
3. Stuck bearing3. Manually rotate fan blade3. Clean and lubricate bearing
4. Control circuit failure4. Inspect loose Faston connector4. Reconnect or replace connector
Reduced airflow1. Clogged filter1. Check filter blockage1. Clean or replace G2 filter
2. Dust accumulated on blades2. Inspect blade cleanliness2. Clean blades with soft brush
3. Subtensiune3. Measure operating voltage3. Adjust voltage to rated value
4. Rotire inversă4. Verify mounting direction4. Reinstall fan outward air discharge
Abnormal noise1. Worn bearing1. Locate noise source1. Replace bearing or whole fan
2. Unbalanced fan blade2. Check blade deformation and attachments2. Correct balance and clear debris
3. Loose mounting3. Tighten mounting screws3. Fasten all screws
4. Vibration resonance4. Observe cabinet vibration4. Add shock pad or adjust position
Protecție la supracurent1. Motor short circuit1. Test insulation resistance1. Replace motor
2. Excessive bearing friction2. Check bearing flexibility2. Lubricate or replace bearing
3. Supratensiune3. Measure operating voltage3. Restore normal voltage
  1. Mediul de aplicare & Cazuri industriale

Scenarii aplicabile

  1. Automatizare industrială: Cooling for PLC, inverter and servo drive cabinets
  2. Sistem de alimentare: Heat dissipation for outdoor ring main units, box substations and charging pile control boxes
  3. Telecommunication: Ventilation for base station cabinets, optical distribution boxes and data center server cabinets
  4. Tranzit Feroviar: Temperature control for signal boxes and converter cabinets
  5. Energie Nouă: Cooling for photovoltaic inverters and energy storage control cabinets

Non-recommended Scenarios

  1. Corrosive atmosphere such as chemical and marine environment (anti-corrosion model required)
  2. Heavy dust sites like mines and cement plants (extra pre-filter needed)
  3. Submerged or long-term rain exposure (IP54 only splash-proof)
  4. Fully sealed space without air inlet circulation

Typical Cases

Automobile Factory: Installed on welding robot cabinets, failure rate reduced by 70% against high temperature

Power Grid Company: Eliminated switch misoperation, equipment service life extended 3 ori

Centru de date: Hierarchical cooling with air conditioner, energy consumption cut by 20%

  1. Sfaturi de selecție & Avoidance Guide

Quick Calculation Rule

  1. Airflow demand = Cabinet volume × (8~10) m³/h, suitable for 16~20m³ cabinet
  2. Selectarea tensiunii: 230V for general industry, 115V for North America, 24V for DC system
  3. Mounting mark: M=side, MF=top, FB=bottom

Operation Warnings

  1. Inspect and replace G2 filter every 3 months to avoid airflow drop and motor overload
  2. Keep air outlet outward and match air inlet for effective ventilation
  3. Adopt cabinet air conditioner when external temperature is 5℃ higher than internal temperature
  4. Restrict voltage fluctuation within ±10% to guarantee service life
  5. Confirm UL, CE and other certifications for export use
  6. Order Information

Model: NSYCVF165M230PF

Comanda nr.: NSYCVF165M230PF (Global unified)

Package Contents: 1 axial fan motor, 1 cutting template, 1 pre-filter, 1 air outlet grille, 1 power cable, 2 protective grilles

Delivery Lead Time: 3-5 working days for standard stock items