Schneider RE48ATM12MW Time Delay Relay Installation Manual Full Product Name: Harmony RE48A Series Electronic On-Delay Time Relay Model: RE48ATM12MW (8-pin, 2 contacte de schimbare, 24~240V AC/DC, On-Delay only) Nota: This manual is compiled based on Schneider official datasheet, available for on-site installation, commissioning and document filing. Table of Contents RE48ATM12MW RE48A: Harmony RE48A series, 48×48mm panel-mount ...

  • Detalii despre produs

Schneider RE48ATM12MW Time Delay Relay Installation Manual

Numele complet al produsului: Harmony RE48A Series Electronic On-Delay Time Relay

Model: RE48ATM12MW (8-pin, 2 contacte de schimbare, 24~240V AC/DC, On-Delay only)

Nota: This manual is compiled based on Schneider official datasheet, available for on-site installation, commissioning and document filing.

Cuprins

RE48ATM12MW

RE48A: Harmony RE48A series, 48×48mm panel-mount electronic time delay relay

T: La întârziere (single function, power-on delay only)

M: Wide supply voltage 24…240V AC/DC

12: 2 contacte de schimbare (2C/O)

W: 8-pin plug-in socket interface

Core Definition: Single-function On-Delay Relay. It cannot be switched to off-delay, pulse or flashing modes.

  1. Main Electrical Specifications
ArticolCaietul de sarcini
Function ModeLa întârziere (Mode A)
Tensiune de alimentare24~240V AC/DC Universal (AC & DC compatible)
Ieșire de contact2 seturi de contacte cu comutare (2C/O, DPDT), AgNi cadmium-free contacts
Rated Contact Current5O / 250V și (AC-12); 1.5Și AC-15; 2A/30V DC-13
Adjustable Delay Range0.02s ~ 300h, selectable front panel ranges:
0.02–1.2s / 0.05-3s / 0.2–12s / 0.5–30s / 2–120s / 5-300 de ani
0.2–12min / 0.5–30min / 2–120min /5–300min
0.2–12h / 0.5–30h / 2–120h /5–300h
Precizie de repetare±0.2% of full scale
Consumul de energie0.5W(24V) ~ 1.7W(240V)
Rezistenta mecanica30 milioane de operațiuni; Rezistenta electrica (5A resistive load): 100,000 operațiuni
Protecție la intrareFront face IP50, housing IP40
Decupaj panouStandard 48×48mm instrument cutout
Interfață8-pin circular socket
Greutate netăAproximativ. 140g
  1. Operating Logic (La întârziere)
  2. Power applied to A1/A2 → timing starts;
  3. Before timing elapses: contacts remain in initial state;
  4. When preset delay expires: both sets of changeover contacts operate simultaneously;

⚠️ Important: Front panel DIP selector

Poziţie 1: Both outputs timed

Poziţie 2: One timed output, the other instantaneous upon power-up

  1. Power removal resets the relay; timing restarts after re-energization.
  2. Matching Sockets & Accesorii

Socket is NOT supplied with relay and must be ordered separately:

  1. DIN rail mounting socket: RUZC2M (8-pin screw terminal, most common)
  2. PCB mounting socket: RE48ASOC8SOLD

Accesorii optionale:

RE48ASETCOV: Setting protective cover (prevents unauthorized adjustment)

RE48AIPCOV: IP64 dust & waterproof front cover

  1. 8-Pin Terminal Definition (RUZC2M Socket)

2, 7: A1, A2 Coil Power Terminals

1-3-4: 1st changeover contact set

8-5-6: 2nd changeover contact set

  1. Procedura de configurare
  2. Toggle front panel time base selector (s/min/h)
  3. Select range limit via rotary knob (de ex. 30s range)
  4. Rotate pointer knob to set target delay
  5. Select operating mode: Dual timed outputs / One timed + one instantaneous output
  6. Alternative Replacement Models

Înlocuire directă

  1. RE48AMH13MW (8-pin, multi-function version). Supports on-delay, pulse timing and more. Fully interchangeable with the same socket.

Diferenţă: ATM = On-Delay only; AMH = Multi-function

Compact Alternative (Integrated DIN rail type, no separate socket)

RE22R2AMU (DIN rail mounted, dimensiune mai mică, not suitable for 48×48 panel cutout installation)

  1. Scenarii tipice de aplicare

Ventilator & pump startup delay, star-delta motor starting delay

Sequential startup of conveyor systems, equipment power-on buffer delay

HVAC system timing control, lighting delayed switch-on

  1. Riscuri & Prohibitions
  2. Do not feed voltage higher than 250V into contact circuits; freewheeling diode recommended for DC inductive loads;
  3. Brief power interruption <10ms will NOT trigger reset; sufficient power-off duration is required for reliable reset;
  4. This model has no external reset terminal. Reset can only be achieved by cutting supply power;
  5. Avoid environments with continuous condensation. Add filtering if installed close to inverters for EMC suppression.
  6. Safety Instructions (Mandatory Reading)
  7. Prezentare generală a produsului & Descrierea modelului
  8. Matching Sockets & Selectarea accesoriilor
  9. Two Installation Methods & Proceduri
  10. Definiția terminalului & Diagrama de cablare standard
  11. Parameter Setting Procedure
  12. Power-on Commissioning Steps
  13. Specificații electrice
  14. Ghid de depanare
  15. Restricții de instalare & Cerințe de mediu
  16. Safety Instructions ⚠️【Important】
  17. Cut off upstream power supply before all installation, wiring and disassembly operations. Live working is forbidden;
  18. Contact circuits must not exceed rated load: 5A/250V AC. Freewheeling diode is recommended for DC inductive loads;
  19. Do not deploy in flammable/explosive environments, locations with continuous condensation or corrosive gas;
  20. No serviceable parts inside the unit. Do not disassemble; replace complete unit upon failure;
  21. Verify supply voltage before installation: 24~240V AC/DC. Voltaj >264V is prohibited;
  22. Tightening torque for socket terminals: 0.8~1,2 N·m. Avoid over-tightening which cracks plastic base.
  23. Prezentare generală a produsului

Funcţie: Single-function On-Delay (Power-On Delay)

Form Factor: 48×48mm panel mount, 8-pin plug-in interface

Alimentare electrică: Wide range 24…240V AC/DC

Ieșire: 2 seturi de contacte cu comutare (2C/O)

Interval de întârziere: 0.02s ~ 300h, time base selectable via front panel switch

Evaluare de protecție: Front IP50, housing IP40

Model Code Recap

RE48A-T-M-12-W

RE48A: 48×48 panel time relay

T: La întârziere (single function)

M: 24~240V AC/DC wide voltage supply

12: 2 contacte de schimbare

W: 8-pin circular plug socket

  1. Matching Socket & Accesorii optionale

Socket is not included with RE48ATM12MW and must be ordered separately

NumeModelAplicație
DIN Rail Mount SocketRUZC2M (8-pin)Control cabinet DIN rail mounting (most widely used for projects)
PCB Solder SocketRE48ASOC8SOLDPCB soldering installation
Parameter Lock CoverRE48ASETCOVPrevent on-site unauthorized time adjustment
IP64 Waterproof Front CoverRE48AIPCOVUpgrade dust & water resistance for operation panels
  1. Two Installation Procedures

Metodă 1: Montare pe șină DIN (RUZC2M Socket)

  1. Align clips of RUZC2M socket onto standard 35mm DIN rail, press down until fully locked;
  2. Loosen socket terminal screws with screwdriver for wiring;
  3. Complete all cable wiring;
  4. Vertically align RE48ATM12MW with 8-pin socket, press evenly until fully seated;

Do not force insertion at an angle to prevent bending of contact pins.

Metodă 2: Control Cabinet Panel Cutout Mounting

  1. Panel cutout dimension: 48⁺⁰·⁶₋₀ mm × 48⁺⁰·⁶₋₀ mm
  2. Applicable panel thickness: 1mm~10mm
  3. Insert relay body from front of panel through cutout;
  4. Fit mounting bracket at rear of panel, tighten fixing screws evenly on both sides;
  5. Connect 8-pin wiring socket from rear side;

Reserve ≥10mm clearance between adjacent devices for heat dissipation.

  1. 8-Pin Terminal Definition (Standard RUZC2M Socket)
Terminalul nr.Descrierea funcției
2A1 Power Terminal
7A2 Power Terminal
1Common of 1st contact set COM1
3Timed Normally Open NO1 (1st set)
4Timed Normally Closed NC1 (1st set)
8Common of 2nd contact set COM2
6Timed Normally Open NO2 (2nd set)
5Timed Normally Closed NC2 (2nd set)

Front Panel Function Selector Switch

Poziţie 1: Both outputs timed (Implicit din fabrică)

Poziţie 2: One timed output, one instantaneous output upon power-up

Standard Wiring Guide

  1. Power circuit: Control supply connected to 2,7 (A1/A2)

AC supply: L and N can be connected to 2/7 arbitrarily, no polarity

DC supply: Positive/negative polarity interchangeable, universal for AC & DC

  1. Circuit de încărcare:

Terminal comun 1 → Timed NO 3; Terminal comun 8 → Timed NO 6

Operating Logic: Power applied to 2,7 → timing starts; After preset delay, 1-3 închis, 8-6 închis. Relay resets immediately after power cut.

  1. Front Panel Parameter Setting Steps
  2. Energize relay (UP LED indicator lights = standby timing status);
  3. Time base selector: Choose s / min / h (secunde / Minute / Ore);
  4. Rotate adjustment knob to set target delay duration;
  5. Toggle function selector: Dual timed outputs / One timed + one instantaneous output;
  6. Optionally install RE48ASETCOV protective cover to lock parameters.

Available Delay Ranges

0.02–1.2s / 0.05-3s / 0.2–12s / 0.5–30s

2–120s / 5-300 de ani / 0.2–12min / 0.5–30min

2–120min /5–300min /0.2–12h /0.5–30h /2–120h /5–300h

  1. Power-on Commissioning Procedure
  2. Check wiring under power-off condition; confirm no short circuit in power and load circuits;
  3. Switch on power; steady UP LED = timing standby state;
  4. Wait until preset delay expires;
  5. Upon delay completion: Contacts switch state;
  6. Cut power supply to terminals 2,7 for relay reset; timing restarts after re-power;
  7. Perform multiple cycle tests to verify timing accuracy;

Brief power interruption <10ms cannot reset relay. Complete power cut ≥50ms required for reliable reset.

  1. Specificații electrice de bază
ArticolParametru
Supply Range24~240 V AC/DC, 50/60Hz
Evaluarea contactului5A 250V AC-12; 1.5Și AC-15; 2A/30V DC-13
Timing Repeat Accuracy±0.2% full scale
Consumul de energie0.5W~1.7W
Rezistenta mecanica30 milioane de operațiuni; Rezistenta electrica 100,000 operations under resistive load
Temperatura ambiantă de funcționare-20 ℃ ~ +55 ℃, fara condens
Temperatura de depozitare-40 ℃ ~ +70 ℃
  1. Troubleshooting Table
Fenomen de eroareCauze posibileSoluții
UP LED does not light after power-up1. No power on 2/7; 2. Voltage out of range; 3. Poor pin contactCheck supply voltage, re-seat relay unit, measure voltage at socket terminals 2 & 7
Contacts activate immediately after power-up without delayIncorrect DIP switch setting; Model confusion (Do not mix up with multi-function RE48AMH)Verify selector switch position; Confirm model is RE48ATM12MW (On-Delay only)
Contacts fail to switch after delay expiresSarcină supraîncărcată; Contact erosion; Cabluri slăbiteReduceți curentul de sarcină, tighten terminals; Replace relay if contacts are damaged
Inaccurate timing durationWrong time base range; Exces de temperatură ambientalăReselect correct time base; Îmbunătățiți disiparea căldurii
Unintended frequent resetTransient voltage drop or interference on power supplyAdd filtering components to stabilize control circuit supply
  1. Restricții de instalare & Operating Boundaries

❌ Forbidden Operations:

  1. Apply voltage exceeding 250V to contact circuits;
  2. Mount in close proximity to inverters and large contactors (interferențe electromagnetice puternice);
  3. Enclosed installation causing heat accumulation; continuous operation above 55 ℃ temperatura ambiantă;
  4. Pull cables to forcibly unplug relay, resulting in bent socket pins;
  5. Deploy for high-frequency pulse control (accelerates electronic component aging).

✅ Recommendations:

Install surge absorption components in parallel for inductive loads (bobine de contactor); Reserve ventilation space inside control cabinet; Use 0.75~1.5mm² copper cables.

Apendice: Alternative Reference

Direct socket-compatible replacement: RE48AMH13MW (8-pin multi-function model)

Diferenţă: ATM = On-Delay only; AMH supports on-delay, întârziere la oprire, flashing and other modes.