Schneider RSB2A080U7 Plug-in Interface Relay - Contactor,întrerupător de circuit,senzor,Codificator,PLC,Convertor

Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Despre Contact |

Schneider RSB2A080U7 Plug-in Interface Relay - Contactor,întrerupător de circuit,senzor,Codificator,PLC,Convertor

PLC/

Schneider RSB2A080U7 Plug-in Interface Relay

Serie: Harmony RSB Plug-in Interface Relay (Zelio) | Stare: Obsolete ✅ Model Explanation RSB: RSB series plug-in interface relay 2A: 2 contacte de schimbare (2CO / DPDT, 2NU+2NC) 080: Rated contact current 8A U7: 240bobina V AC, fara LED, no test button 📌 Key Specifications Coil voltage: 240V și (50/60Hz) Contacte: 2 C/O (DPDT), AgNi silver-nickel ...

  • Detalii despre produs

Serie: Harmony RSB Plug-in Interface Releu (Zelio) | Stare: Învechit

✅ Model Explanation

RSB: RSB series plug-in interface relay

2O: 2 contacte de schimbare (2CO / DPDT, 2NU+2NC)

080: Rated contact current 8A

U7: 240bobina V AC, fara LED, nici un buton de testare

📌 Specificații cheie

Tensiunea bobinei: 240V și (50/60Hz)

Contacte: 2 C/O (DPDT), AgNi silver-nickel contacts

Evaluarea contactului: 8A @250VAC / 8A @28VDC

Tensiune maximă de comutare: 250VAC / 300VDC

Rezistenta bobinei: 33kΩ; Coil current approx. 7.3mA

Operate / release time: 20Domnișoară

Temperatura de functionare: -40℃ ~ +70℃

Indicator luminos: Nici unul; Butonul de testare: Nici unul

Montare: Tip de plug-in, used with base

Standarde: IEC61810-1, UL508, CSA, EAC certification

🧩 Matching Bases (8-pin, 2CO)

RSZE08P: Spring-cage terminal base

RSZE1S48M: Screw terminal base (versiunea veche)

🔄 Replacement Recommendations

No direct one-to-one OEM equivalent. Prefer same-spec models within the same series:

  1. RSB2A080M7: 230VAC, 8O, 2CO (most common in domestic market, fara LED, nici un buton de testare)
  2. If LED indicator required: RSB2A080M7S (releu + base assembly)
  3. Alternativă Schneider RXG series: RXG22M7 (230VAC, 8O, 2CO, incompatible base)

Nota: 240VAC and 230VAC are generally compatible under normal grid conditions. Confirm coil specification for voltage-sensitive circuits.

📎 Applications

PLC/controller DO isolation, small contactor coil driving, signal transfer, cabinet interface isolation. Widely used in industrial control, HVAC și mașini de ambalare.

📌 Additional Info

Ambalare: 10 buc per cutie. It is an obsolete spare part, only stock available. Nu este recomandat pentru proiecte noi.

Application Fields of Schneider RSB2A080U7 (240bobina VAC, 2CO, 8A Interface Relay)

Core function: Izolarea semnalului, level conversion and small-load driving inside control cabinets. The 240VAC coil is designed for AC control circuits. Plug-in design facilitates spare parts replacement, în principal pentru modernizarea și întreținerea echipamentelor existente (obsolete model).

  1. Automatizare industrială (Aplicație primară)

PLC digital output isolation: PLC DO drives contactor coils, solenoid valves and indicator lamps to suppress electrical interference and protect PLC modules

Local cabinet control loops, hard-wired logic, signal transfer and passive dry contact expansion

Control panels for machine tools, linii de producție automate, conveyor systems and assembly equipment

  1. HVAC

Auxiliary control for air handling units, fresh air units, damper actuators, water valves and fan start/stop

DDC output isolation for building automation, signal switching for heating and cooling units

  1. Ambalare, Textile & Mașini de imprimat

Auxiliary circuits for packaging machines, mașini de fabricat pungi, textile machines and printing machines; driving small electromagnetic devices, alarm lamps and counters

Signal switching for local machine control panels

  1. Sisteme electrice de clădire

Group lighting control, fani, ventilatoare de evacuare, electric roller shutters and auxiliary access control outputs

Auxiliary signal and alarm loop switching in low-voltage distribution cabinets and control boxes

  1. Aprovizionare cu apă & Wastewater Treatment

Auxiliary pump control, liquid level signal transfer, dosing equipment and valve bank control loops

Instrument signal isolation to protect transmitters, water quality analyzers and other low-voltage devices

  1. Other Supporting Equipment

Small test equipment, power cabinets, medical auxiliary equipment and warehouse logistics equipment

Export control cabinets for 240VAC grid markets and spare part replacement for overseas legacy machines

✅ Suitable Operating Conditions

Control side: 240VAC AC control circuit; Sarcina maxima: 8O, 250VAC low-power loads

Avantaje: 2 changeover contacts providing NO and NC signals simultaneously; plug-in base for fast maintenance

Limitări: Not suitable for direct driving of high-power motors, high-frequency switching or heavy inductive impulse loads (RC snubber recommended)

❗ Selection Reminder

This model has a 240V AC coil. For new domestic projects with 230VAC supply, RSB2A080M7 is preferred. RSB2A080U7 is mostly used for overseas equipment and legacy unit maintenance replacement.

Replacement List for Schneider RSB2A080U7 (No Exact OEM Equivalent)

Model original: RSB2A080U7|240VAC coil, 2CO, 8O, fara LED, nici un buton de testare, plug-in RSB series, învechit

Compatible bases: RSZE08P (cușcă de primăvară) / RSZE1S48M (borna cu șurub)

  1. Same RSB Series (Direct Base Reuse, Pinout Compatible)
  2. RSB2A080M7 (Top Choice for Maintenance)

Specificații: 230bobina VAC, 2CO, 8O, fara LED, nici un buton de testare

Descriere: 230VAC and 240VAC are generally compatible in most grid environments. Direct plug-in to original base without rewiring, mainstream replacement for domestic maintenance

Diferenţă: Nominal coil voltage 230V vs original 240V; contacte, current rating and pinout are identical

  1. RSB2A080M7S (Asamblare: Releu + Baza)

Supplied with base, suitable for new projects where separate base procurement is not desired

  1. RSB2A080M7PV (LED indicator version)

230VAC, 2CO, 8A with LED indicator; ideal for retrofit requiring visual status check

⚠️ Atenție: If equipment strictly requires 240VAC (overseas grid with tight voltage tolerance), M7 (230V) is not suitable. Cross-brand 240VAC models should be selected instead.

  1. Other Schneider Series (Base Not Interchangeable, Base Must Be Replaced)
  2. RXG22M7

RXG series, 230VAC, 2CO, 8O; plug-in interface relay with similar size and performance

Dezavantaj: Different base model, original base cannot be reused; RXG base required

  1. RXM2AB2P7 (Releu miniatural RXM)

230VAC, 2CO, 8O; widely stocked; different outline and base, suitable for new cabinet layout

  1. Cross-brand Compatible Replacements (For Export/Maintenance, Strict 240VAC Requirement)

Cerințe: 2CO, 8O, 240bobina VAC, 8-pin plug-in

Omron: MY2N-CR 240VAC (8O, DPDT)

Weidmüller: DRM2700240L

Phoenix Contact: REL-IR2 / 240AC

Chint: NXJ-2Z/240VAC

Important: Verify pin assignment before replacement. Pin layout varies between brands; do not plug in blindly.

  1. Replacement Selection Rules

✅ Domestic legacy equipment maintenance, 220/230V grid: Prioritize RSB2A080M7, reuse existing base with minimal modification

✅ Export equipment, stable 240VAC grid: Prioritize cross-brand 240VAC coil models

✅ Status indication required: RSB2A080M7PV

✅ New projects, no base restriction: RXG22M7 / RXM2AB2P7

  1. Note de risc

Coil voltage is the critical difference: U7=240VAC; M7=230VAC. Do not mix for voltage-sensitive circuits

Contact specs: All adopt AgNi silver-nickel contacts, 8A@250VAC. RC snubber is recommended for inductive loads

All RSB series share the same mechanical and electrical life ratings, differing only in coil voltage and LED option

Full Model List of Schneider Harmony RSB Plug-in Interface Relay (Zelio)

Prezentare generală a seriei: Plug-in interface relay, three contact configurations:

RSB1A120: 1CO, 12O

RSB1A160: 1CO, 16O

RSB2A080: 2CO, 8O (RSB2A080U7 belongs to this subgroup)

Definiția sufixului:

Suffix D = DC coil; Sufix 7 = AC coil (50/60Hz)

PV = with LED indicator + varistor surge protection; S = relay + base assembly

No PV suffix: fara LED, nici un buton de testare; No mechanical test button available for this series

Bases: RSZE08P (spring-cage terminal) / RSZE1S48M (borna cu șurub)

  1. DC Coil Models
Tensiunea bobinei1CO 12A1CO 16A2CO 8A
6În DCRSB1A120RDRSB1A160RDRSB2A080RD
12În DCRSB1A120JDRSB1A160JDRSB2A080JD
24În DCRSB1A120BDRSB1A160BDRSB2A080BD
48În DCRSB1A120EDRSB1A160EDRSB2A080ED
60În DCRSB1A120NDRSB1A160NDRSB2A080ND
110În DCRSB1A120FDRSB1A160FDRSB2A080FD
  1. AC Coil Models (Versiunea de bază, Fara LED)
Tensiunea bobinei1CO 12A1CO 16A2CO 8A
24V șiRSB1A120B7RSB1A160B7RSB2A080B7
48V șiRSB1A120E7RSB1A160E7RSB2A080E7
120V șiRSB1A120F7RSB1A160F7RSB2A080F7
230V șiRSB1A120P7RSB1A160P7RSB2A080P7
230V și (M7 domestic marking)RSB1A120M7RSB1A160M7RSB2A080M7
240V și (Învechit)RSB1A120U7RSB1A160U7RSB2A080U7

III. PV Suffix Models (LED + Protecție la supratensiune, AC)

Tensiunea bobinei1CO 12A1CO 16A2CO 8A
24V șiRSB1A120B7PVRSB1A160B7PVRSB2A080B7PV
120V șiRSB1A120F7PVRSB1A160F7PVRSB2A080F7PV
230V șiRSB1A120P7PVRSB1A160P7PVRSB2A080P7PV
230V AC M7RSB1A120M7PVRSB1A160M7PVRSB2A080M7PV
  1. S Suffix Assembly Models (Releu + Baza, DIN Rail Mount Directly)

Regulă: Add S to the end of base model, de ex. RSB2A080M7S, RSB2A080P7S, RSB1A120B7S

Supplied complete with base, no separate RSZE base purchase required, ideal for fast new project selection

  1. Defalcarea codării modelului (RSB)

RSB + Contact Quantity + O + Curent nominal + Cod de tensiune + Optional PV/S

RSB: Harmony plug-in interface relay

1A = 1CO; 2A = 2CO

120=12A; 160=16A; 080=8A

Last two characters: voltage code

JD=12VDC, BD=24VDC, ED=48VDC, FD=110VDC

B7=24VAC, F7=120VAC, M7=230VAC, P7=230VAC, U7=240VAC (învechit)

PV: Indicator LED + protectie la supratensiune; S: asamblare (releu + baza)

  1. Note importante
  2. RSB2A080U7 / RSB1A120U7 / RSB1A160U7 (240VAC) are all obsolete, only stock spares available. M7/P7 are preferred for new projects
  3. Uniform AgNi silver-nickel contacts, suitable for PLC isolation, HVAC, ambalaj, water treatment and other industrial control circuits
  4. Identical pinout within the same series. Same contact configuration can be swapped on the same base
  5. Durata de viata mecanica: 10,000,000 operațiuni; Durata de viata electrica: 100,000 operațiuni sub sarcină rezistivă

Prev:

Lasă un răspuns

Lăsaţi un mesaj