Descrierea modelului: ACS355 machinery drive frequency convertor; 03E = 3-phase input, IP20 enclosure; 07A3 = rated output 7.3 O; 4 = 380–480 V voltage class
Numărul piesei: 3AUA0000058188
✅ Core Electrical Specifications
Putere nominală: 3.0 kW (suprasarcina usoara / taxă standard)
Rated Output Current I₂ₙ: 7.3 O
Intrare: 3-phase 380–480 V ±10%, 48-63 Hz
Ieșire: 0 ~ Uₙ, 0–599 Hz
Enclosure Protection: IP20 (without +B063 or other options)
Dimensiunea cadrului: R0
Răcire: Răcire cu aer
Motor compatibil: 3 Motor asincron trifazat kW
📦 Dimensions & Greutate
Unitate: W70 mm × H239 mm × D161 mm
Greutate netă: 1.8 kg
Packaged Size: 350×220×130 mm, Greutate brută 2.3 kg
🧩 On-board I/O (Standard)
5 Intrări digitale (DIN)
1 Ieșire releu (RO)
2 Intrări analogice (AI, 0-10 V / 4-20 mA)
1 Ieșire analogică (LA, 4-20 mA)
Modbus RTU încorporat (Terminal X1)
Optional plug-in communication adapters: Profibus DP, CANopen, DeviceNet, EtherCAT, etc.
📌 Aplicații tipice
Mașini generale: transportoare, fani, pompe, mixere, small processing machines. Supports standard V/F control and vector control, preset speeds, ramps, multi-set parameter groups.
⚠️ Selectie & Note de înlocuire
- For IP66 version: add suffix +B063. Dimensions and weight differ completely, part number changes.
- Upgrade alternative within ABB portfolio: ACS380. Older ACS350 of the same power can be cross-referenced by current rating.
- Siguranță / întrerupător de circuit: sized per 7.3 A converter standard circuit. Output du/dt reactor is optional.
📎 Common Spare Parts & Accesorii
Control Panels: ACS-CP-A / ACS-CP-D
Input filter, output du/dt filter, braking resistor (braking chopper built-in)
Communication adapters, Module de extindere I/O
ABB ACS355 (ACS355-03E-07A3-4)|Factory Default Parameters for ABB Standard Macro (9902=1)
Nota: Parameters in Group 99 (datele de pe plăcuța motorului) have no fixed default values. Enter data per 3 kW motor nameplate after power-up.
| Parametrul nr. | Nume parametru | Default Value | Observații |
| 9902 | Application Macro Selection | 1 ABB Standard Macro | DI1 start, DI2 direction, AI1 reference; cel mai utilizat |
| 9904 | Motor Control Mode | 3 Scalar (V/F) | Opțional: 1=Vector Speed, 2=Vector Torque |
| 9905 | Motor Rated Voltage | — | Follow nameplate; 380 V for standard 3 motor kW |
| 9906 | Motor Rated Current | — | Typical value for matched motor ≈6.2 A |
| 9907 | Motor Rated Frequency | — | 50 Hz for general asynchronous motors |
| 9908 | Motor Rated Speed | — | 1440 rpm (4-pol) |
| 9909 | Motor Rated Power | — | 3.0 kW |
| 1001 | Ext1 Start/Stop Command | 2 DI1 | DI1 closed = Run |
| 1002 | Ext Direction Command | 3 DI2 | DI2=0 Forward, DI2=1 Reverse |
| 1103 | Ext Reference 1 Selecţie | 1 AI1 | AI1 0–10 V / 4-20 mA |
| 1105 | Ext Reference 1 Maxim | 50.0 Hz | Matches full-scale AI signal |
| 1201 | Constant Speed Selection | 0 Not Selected | Multi-speed via DI combination |
| 1301 | AI1 Minimum | 0.0 V | 0 V corespunde 0 Hz |
| 1302 | AI1 Maximum | 10.0 V | 10 V corespunde 50 Hz |
| 1304 | AI2 Minimum | 0.0 V | AI2 disabled by default |
| 1401 | Relay Output RO1 Source | 0 Ready | Output when drive is ready |
| 1501 | AO1 Signal Source | 102 Frecvența de ieșire | LA: 4–20 mA mapped to 0–50 Hz |
| 1504 | AO1 Minimum Output | 4 mA | |
| 1505 | AO1 Maximum Output | 20 mA | |
| 2007 | Minimum Frequency | 0.0 Hz | |
| 2008 | Maximum Frequency | 50.0 Hz | |
| 2202 | Timp de accelerare 1 | 5.0 s | |
| 2203 | Timp de decelerare 1 | 5.0 s | |
| 2102 | Stop Mode | 1 Coast Stop | 2=Ramp Stop |
| 2601 | U/F Ratio | 1 Liniar | Squared for fan/pump duty |
| 3017 | Overcurrent Trip Limit | 4×I₂n | |
| 3025 | STO Function | 0 Alarm Only | Setați la 1 triggers fault 0044 |
| 5302 | EFB Station Address | 1 | Modbus RTU Slave Address |
| 5303 | Baud Rate | 9600 | |
| 5304 | Paritate | 0 No Parity, 1 Stop Bit |
ACS355 Fault Code List (English with Troubleshooting Guidance)
| Cod de eroare | Fault Name | Descriere | Depanare comună |
| 1 | Supracurent | Output current exceeds trip threshold | Scurtcircuit motor, deteriorarea cablului, locked load, too short ramp time, incorrect motor data |
| 2 | DC OVERVOLT | DC bus voltage too high | Fast deceleration, regenerative load, high supply voltage, missing braking resistor |
| 3 | DEV OVERTEMP | IGBT module overtemperature | Blocked airflow, failed fan, temperatura ambientala ridicata, suprasarcina, poor cabinet ventilation |
| 4 | SHORT CIRC | Motor-side short circuit | Motor winding short, phase-to-phase short on power cable, shorted output terminals |
| 6 | DC UNDERVOLT | DC bus voltage insufficient | Faza de intrare lipsește, open fuse/contact, voltage dip, undersized supply |
| 9 | MOT OVERTEMP | Estimated motor temperature exceeded | Suprasarcina motorului, răcire slabă, incorrect motor thermal protection settings |
| 16 | EARTH FAULT | Earth leakage on motor/power cable | Damaged cable insulation, motor insulation failure, pătrunderea umezelii |
| 22 | SUPPLY PHASE | Pierderea fazei de intrare / 3-dezechilibru de fază | Blown input fuse, poor contactor contacts, unbalanced 3-phase supply |
| 44 | SAFE TORQUE OFF (STO) | STO safety circuit activated | STO terminals not jumpered, safety loop open, parameter 3025=1 triggers fault |
| 28 | COMM ERROR | Built-in EFB bus communication break | Modbus wiring, rezistor de terminare, aborda conflictul, master offline |
| 35 | AI1 LOSS | AI1 signal below fault threshold | Transmitter wire break, faulty sensor, threshold setting in 3021 |
| 36 | AI2 LOSS | AI2 signal loss | Broken AI2 wiring, emițător defect |
| 41 | ID RUN FAIL | Motor identification run failed | Wrong motor wiring, mismatched power rating, rotor blocat |
| 51 | USER PARAM FAULT | Parameter set corrupted | Restore factory defaults and re-enter motor parameters |
| 71 | FAN FAULT | Cooling fan failure | Fan jammed, fan supply fault |
✅ Reset Methods: Panel RESET, DI reset, communication reset, ciclu de alimentare. Fault history stored in Group 04 parametrii.
Quick Operation
Resetare din fabrică: Parametru 9606, enter RESET. The drive restarts and loads ABB Standard Macro defaults.
Installation Notes for ABB ACS355-03E-07A3-4 (Frame R0, IP20)
This unit is for cabinet installation only. Clasament IP20, not suitable for direct outdoor exposure.
- Montaj mecanic & Disiparea căldurii
- Orientarea montajului: Vertical upright installation is mandatory. Do not invert. Side mounting is permitted for R0 frame but vertical is preferred. Cooling air flows bottom-in, top-out; inverted mounting causes overheating fault 0003.
- Minimum Clearances
Top ≥75 mm, Bottom ≥75 mm; no mandatory side clearance, reserve space for maintenance.
Stacked multiple drives: hot exhaust from lower unit must not blow directly onto upper unit. Use baffles, staggered layout or independent air ducts.
- Mounting Options: Screw fixing or 35 mm șină DIN standard. Mounting base must be rigid and flame-retardant. Prevent conductive dust from entering the unit during drilling (risk of short circuit).
- Condiții de mediu
Temperatura mediului ambiant: -10 ~ +50 °C; reduceți mai sus 40 °C. Fara condens, fara glazura.
Altitudine: Full rating ≤1000 m; derate with increasing altitude above 1000 m.
Prohibited environment: conductive dust, gaz corosiv, strong magnetic fields (near contactors / large single-core cables), heavy vibration or shock.
- Siguranţă & Power-off Procedures (Critic)
After disconnection, așteaptă 5 minutes for DC bus capacitors to fully discharge before opening covers, wiring or measuring. Do not touch power terminals or internal PCB when powered.
For permanent magnet motors: motor may generate back EMF when rotating even with supply disconnected. Mechanically lock the shaft before working on motor cables.
Before power-up: Disconnect U2/V2/W2 at the converter, test motor insulation to earth with 1000 V megger. Do not energise if insulation is poor (≥100 MΩ @25°C for ABB motors).
Strictly forbidden: Connect mains supply to U2/V2/W2 output terminals, this will destroy the unit.
- Selectarea cablului, Dirijare & EMC
- Cable Recommendations
Cablu motor: Symmetric shielded VFD cable preferred, reduces bearing currents and EMI. Unshielded standard cables often interfere with sensors and instruments.
Analog signals (AI/Lumea): Double-shielded twisted pair. DI/DO relay signals: shielded twisted pair. Separate power cables and control cables in different trunking, minimum gap ≥20 cm. Cross only at 90° where unavoidable.
Do not mix 24 V low-voltage and 220 V high-voltage circuits inside one cable.
- Shield Grounding Rules
360° shield termination with earthing clamp; avoid pigtail earthing (poor high-frequency EMC performance). Shield of motor cable grounded at both converter and motor ends.
PE conductor must be short, thick and connected reliably to cabinet earth bar.
- IT / Ungrounded Delta System: Remove internal EMC filter earth screw, otherwise earth fault 0016 may occur. Keep screw fitted for standard TN-S systems.
- Output-side Restrictions: Do not connect capacitors or surge suppressors to U2/V2/W2. For long motor cables (>50 m), fit output du/dt reactor to protect motor insulation.
- Cuplul terminalului & STO Safety Circuit
Control terminal tightening torque: 0.4 N·m. Power terminals follow datasheet torque specification.
STO (Oprire sigură a cuplului): Factory fitted with jumper. If STO function is unused, STO terminals must be permanently jumpered. Open STO triggers fault 0044. For safety applications, wire to safety relay contacts.
Rezistenta de franare (BRK+, BRK-): Utilizați cablu ecranat, mount close to drive to minimise lead inductance.
- Input Protection, Legare la pământ & Auxiliary Devices
Fit circuit breaker or fuses on input side, sized for 7.3 O evaluare. Input AC reactor is recommended to reduce harmonic distortion.
Legare la pământ: PE conductors must be home-run separately to earth bar, do not daisy-chain. Never use neutral N as protective earth PE.
Cabinet ventilation: Install cabinet fans to keep internal temperature below 40 °C. Clean filters regularly to prevent blocked cooling paths.
- Pre-power-up Checklist
- Borne de alimentare: U1/V1/W1 supply, U2/V2/W2 motor, BRK+/braking resistor – verify connections.
- Circuite de control: DI/AI/AO, STO jumper, împământarea scutului.
- Insulation test passed, no short circuit or earth leakage.
- Air path unobstructed.
- Motor nameplate data ready; perform motor identification after first power-up.
- Installation-related Fault Quick Reference
0003 Supratemperatură: Blocked airflow, insufficient top/bottom clearance, montaj inversat, high cabinet temperature
0016 Defect de pământ: Împământare incorectă a scutului, EMC screw not removed for IT system, damaged/wet motor cable
0044 STO Fault: STO terminals not jumpered, safety loop open
Fluctuating AI signals: Mixed power/control wiring, poor shield grounding, non-twisted analog cable
ABB ACS355 Model & Part Number List|03E 3-phase 380–480 V, IP20, Filtru EMC încorporat, Versiune standard
Descrierea modelului:
03 = 3-phase input; E = EMC filter enabled (50 Hz); trailing 4 = 380~480 V; +B063 = IP66 high protection variant (comandă separată)
Part Number format: 3AUA00000XXXXX (ABB part number, used for purchasing, quotation and customs declaration)
Frame sizes: R0/R1/R3/R4; built-in braking chopper and STO.
| Model | Rated Power kW | Output Current I₂N(O) | Cadru | ABB Part Number (3AUA) |
| ACS355-03E-01A2-4 | 0.37 | 1.2 | R0 | 3AUA0000058186 |
| ACS355-03E-01A9-4 | 0.55 | 1.9 | R0 | 3AUA0000058243 |
| ACS355-03E-02A4-4 | 0.75 | 2.4 | R0 | 3AUA0000058187 |
| ACS355-03E-03A3-4 | 1.1 | 3.3 | R1 | 3AUA0000058184 |
| ACS355-03E-04A1-4 | 1.5 | 4.1 | R1 | 3AUA0000058185 |
| ACS355-03E-05A6-4 | 2.2 | 5.6 | R1 | 3AUA0000058189 |
| ACS355-03E-07A3-4 | 3 | 7.3 | R0 | 3AUA0000058188 |
| ACS355-03E-08A8-4 | 4 | 8.8 | R1 | 3AUA0000058190 |
| ACS355-03E-12A5-4 | 5.5 | 12.5 | R3 | 3AUA0000058191 |
| ACS355-03E-15A6-4 | 7.5 | 15.6 | R3 | 3AUA0000058192 |
| ACS355-03E-23A1-4 | 11 | 23.1 | R3 | 3AUA0000058193 |
| ACS355-03E-31A0-4 | 15 | 31 | R4 | 3AUA0000058195 |
| ACS355-03E-38A0-4 | 18.5 | 38 | R4 | 3AUA0000058194 |
| ACS355-03E-44A0-4 | 22 | 44 | R4 | 3AUA0000058196 |
Supplementary Range: 01E Single-phase 200–240 V, IP20, EMC încorporat
| Model | Putere kW | Current A | Cadru | Numărul piesei |
| ACS355-01E-02A4-2 | 0.37 | 2.4 | R0 | 3AUA0000058174 |
| ACS355-01E-04A7-2 | 0.75 | 4.7 | R1 | 3AUA0000058175 |
| ACS355-01E-06A7-2 | 1.1 | 6.7 | R1 | 3AUA0000058176 |
| ACS355-01E-07A5-2 | 1.5 | 7.5 | R2 | 3AUA0000058177 |
| ACS355-01E-09A8-2 | 2.2 | 9.8 | R2 | 3AUA0000058178 |
Accesorii comune & Part Numbers for ACS355
| Nume accesoriu | Model | Numărul piesei |
| Basic Control Panel | ACS-CP-A | 3AUA0000040901 |
| Panou de control asistent (chinez) | ACS-CP-D | 3AUA0000040902 |
| Profibus DP Adapter | FPBA-01 | 3AUA0000040888 |
| CANopen Adapter | FCAN-01 | 3AUA0000040889 |
| DeviceNet Adapter | FDNA-01 | 3AUA0000040890 |
| EtherCAT Adapter | FECA-01 | 3AUA0000040891 |
Suffix Options (added after model +xxxx)
+B063: IP66 high protection version (for humid, dusty environments)
+N830: Non-coated PCB (standard cabinet version)
+J400: Potentiometer kit
Exemplu: ACS355-03E-07A3-4+B063 (IP66 variant, different part number)
Model Code Guide for Export Selection
03E: 3-fază, EMC filter enabled (mainstream for China market) ✅
03U: 3-fază, EMC filter disabled (60 Hz overseas version)
03X: Export special version, not common locally
01E / 01U: Monofazat 220 V models
Replacement series: ACS380 (noua generatie, successor to ACS355)