Supapă de vid Univer AG-3232

The AG-3232 is a 3/2-way normally closed vacuum poppet valve. Adoptă control electric cu solenoid cu funcționare pilot de vid și are G3/4″ dimensiunea portului. Este ideal pentru sistemele de vid care necesită debit mare și frecvență mare a ciclului. Model Code Explanation Breakdown of the AG-3232 model code: Code Meaning Detailed Description AG Series Code AG ...

  • Detalii despre produs

The AG-3232 is a 3/2-way normally closed vacuum poppet valve. Adoptă control electric cu solenoid cu funcționare pilot de vid și are G3/4″ dimensiunea portului. Este ideal pentru sistemele de vid care necesită debit mare și frecvență mare a ciclului.

  1. Codul modelului Explicația

Breakdown of the AG-3232 model code:

CodSensDescriere detaliată
AGCod de serieAG Series Vacuum Poppet Valve. Featuring Univer patented poppet structure, special conceput pentru aplicații cu vid.
3Tip de circuit3-way, 2-position valve
2Modul de controlElectric solenoid with vacuum pilot
3Normal PositionÎn mod normal închis (NC)
2Port SizeG3/4″ (DN20) threaded port
  1. Specificatii tehnice principale
CategorieCaietul de sarciniObservații
Basic Characteristics
Valve TypePoppet ValveExcellent sealing performance for vacuum service
Modul de controlElectric solenoid with vacuum pilotExternal vacuum pilot supply (G1/4port)
Normal PositionÎn mod normal închis (NC)Vacuum port closes when power off or no pilot supply
Circuit Configuration3/2-way1 vacuum port, 1 exhaust port, 1 working port
Port Dimensions
Main Port SizeG3/4″ (DN20)Working port / Vacuum port
Pilot Port SizeG1/4External vacuum pilot supply
Parametri de performanță
Maximum Vacuum759.5 mmHg (0.5 Torr)Aproximativ. -0.1 MPa absolute pressure
Minimum Vacuum150 mmHg (610 Torr)Applicable vacuum range
Temperatura ambiantăMax. +50掳CKeep away from high-temperature environments
Working MediumFiltered air (50渭m), lubricated or non-lubricatedClean and dry air is mandatory
Solenoid Voltage12În DC, 24În DC, 24V și, 110V și, 230V șiMultiple coil options available
Manual Operation2-position screw manual overrideManual state switching available during power failure
Physical Parameters
GreutateAproximativ. 1.13-1.17 kgSlight variations among suppliers
MaterialValve body: Aluminum alloy; Seals: Nitrile Butadiene Rubber (NBR)Configurație standard; Viton seals optional
  1. Comparație între mărci & Alternative interne
MarcaModelFunction Matching RatePreț de referință (EUR)Avantaje
UniverAG-3232100%148-228Original genuine product with patented poppet structure and optimal sealing performance
FESTOVUVS-L30-M32C-MD-G18-F795%280-350Well-known brand with comprehensive supporting services
SMCVV5Q3-30-0690%220-280Fast response and compact structure
AVENTICS581140022090%200-250Good contamination resistance, suitable for harsh working conditions
Alternativă internă (E.MC)VT307-03NC85%80-120Cost-effective and short delivery lead time
Alternativă internă (AIRTAC)3V3-08-NC80%60-90Competitive price, ideal for budget-limited projects

Recomandări de selecție

  1. For precision equipment requiring stable vacuum performance, prioritize the original Univer AG-3232.
  2. For general industrial applications, FESTO or SMC alternatives are recommended for similar performance and extensive service networks.
  3. For cost-sensitive projects, choose domestic alternatives from E.MC or AIRTAC for higher cost performance.
  4. Full Model List of AG Series

The AG series vacuum poppet valves cover port sizes from G1/8to G1 1/2″. Common models are listed below:

ModelPort SizeModul de controlNormal PositionObservații
AG-3001G1/8Solenoid with vacuum pilotNCMini size for low flow applications
AG-3002G1/8Solenoid with vacuum pilotNUNormally open type for continuous vacuum operation
AG-3003G1/4Solenoid with vacuum pilotNCGeneral size for small & medium vacuum cup systems
AG-3004G1/4Solenoid with vacuum pilotNUÎn mod normal deschis, G1/4port
AG-3041G3/4Solenoid with vacuum pilotNUHigh flow normally open type, NO version of AG-3232
AG-3081G1/2Solenoid with vacuum pilotNCMedium flow, G1/2port
AG-3222G1/2Solenoid with vacuum pilotNUMedium flow normally open type
AG-3232G3/4Solenoid with vacuum pilotNCSubject model, high flow normally open type
AG-3303G1Solenoid with vacuum pilotNCExtra high flow for large-scale vacuum systems
AG-3322G1Solenoid with vacuum pilotNUExtra high flow normally open type
AG-3403G1 1/2Solenoid with vacuum pilotNCMax size for heavy industrial vacuum applications
  1. Defecte comune & Depanare
Fenomen de eroareCauze posibileInspection StepsSoluții
Insufficient vacuum1. Aged/damaged seals1. Check seals for cracks or wear1. Replace seals (recomandat fiecare 12 luni)
2. Insufficient pilot pressure2. Measure pilot vacuum (≥150 mmHg required)2. Increase pilot vacuum supply
3. Internal valve leakage3. Conduct valve pressure test3. Repair or replace the valve
Valve fails to operate1. Faulty solenoid coil1. Check coil voltage & rezistenţă (15-25Ω for standard 24V DC coil)1. Replace solenoid coil
2. Manual override not reset2. Confirm manual screw is reset2. Screw back the manual override
3. Blocked pilot pipeline3. Dismantle pipeline and check for foreign matters3. Clean pipeline and install filter
Slow valve operation1. Contaminated working medium1. Check clogged filter1. Replace filter and clean the system
2. Delayed solenoid response2. Test solenoid response time (<50ms required)2. Replace solenoid coil
3. Overloaded vacuum system3. Inspect vacuum system for leakage3. Fix leakage points of vacuum system
Frequent failures1. Temperatura ambientală excesiv de ridicată1. Measure ambient temperature (≤+50°C required)1. Add cooling devices or adopt high-temperature resistant model
2. Excessive oil/water in medium2. Check air treatment unit2. Upgrade air treatment system (add dryer)
3. Incorrect installation direction3. Verify installation against flow arrow3. Reinstall the valve correctly

Maintenance Schedule

Zilnic: Check vacuum level and valve operation regularly.

Trimestrial: Clean filters and inspect seal condition every 3 luni.

Anual: Replace seals and carry out full inspection & maintenance for the valve.

  1. Cazuri de aplicare & Industry Guidelines

6.1 Scenarii tipice de aplicare

Linii de producție automatizate: Vacuum material handling systems for metal sheets, sticlă, plastic parts, etc.

Mașini de ambalare: Vacuum thermoforming machines for food, pharmaceutical and other products.

Semiconductor Equipment: Wafer handling systems requiring high vacuum and high cleanliness.

Woodworking Machinery: Vacuum workholding tables for wood cutting, engraving and processing.

Mașini de imprimat: Paper conveying systems using vacuum adsorption for stable paper feeding.

6.2 Industry Application Cases

Caz 1: Automotive Component Production Line

Aplicație: Engine block handling

Working Condition: Handling cast iron blocks up to 50 kg; Vacuum requirement ≥ -0.08 MPa

Soluţie: AG-3232 equipped with 4 pcs of Φ200 mm vacuum cups, matched with vacuum generator

Outcome: Stable handling without falling risks; production efficiency increased by 30%.

Caz 2: Display Panel Assembly Line

Aplicație: LCD panel handling

Working Condition: High cleanliness required; Vacuum requirement ≥ -0.09 MPa; prevent panel scratches

Soluţie: AG-3232 + soft silicone vacuum cups, matched with oil-free vacuum pump

Outcome: Scratch-free handling with 100% yield rate, compliant with cleanroom standards.

6.3 Ghid de selecție

Port Selection: Choose port size from G1/8to G1 1/2according to required vacuum flow.

Normal Position Selection: NC for intermittent operation; NO for continuous operation.

Control Mode Selection: Solenoid with vacuum pilot for high flow; direct solenoid for low flow.

Vacuum Matching: Ensure system vacuum stays within 150 ~ 759.5 mmHg.

Întreținere regulată: Replace seals periodically and keep air source clean.

  1. Instalare & Operation Precautions
  2. Direcția de instalare: Install the valve strictly in line with the flow direction arrow marked on the body.
  3. Pilot Supply: Maintain stable pilot vacuum pressure; pressure regulator is recommended.
  4. Filtration: Install a 50μm filter at the air inlet to prevent foreign matters from entering the valve.
  5. Electrical Wiring: Wire in accordance with the rated coil voltage to avoid overload or short circuit.
  6. Mediul de operare: Do not use in environments with temperature over +50°C, high humidity or corrosive gas.
  7. Manual Override: Only use manual operation in emergency situations; reset it after use.