3M 7622PST-G2 15kV 3-Core Cold Shrink Indoor Termination - Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи

Вичат: +86-13184948252 WhatsApp: 0086-13811255435 Электронная почта: kent@bestcontactor.com

О Контакт |

3M 7622PST-G2 15kV 3-Core Cold Shrink Indoor Termination - Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи

НовостиТорговые новости

3M 7622PST-G2 15kV 3-Core Cold Shrink Indoor Termination

3M 7622PST-G2 15kV 3-Core Cold Shrink Indoor Termination (Cable Terminal)

3M 7622PST-G2 15kV 3-Core Cold Shrink Indoor Termination (Cable Terminal)

  1. Model Segment Interpretation
SegmentЗначениеПримечания
7622Код серии продукта3M QTIII 3rd generation cold shrink technology, 8.7/15kV 3-core indoor termination series
PSTStructural type codePre-expanded Silicone Termination, integrated stress control design
G2Specification adaptation codeSuitable for 3×70~3×120 mm² cable conductor, insulation outer diameter 16.0~28.0 mm
Implied ParameterVoltage level / Installation environment8.7/15кВ (15kV system), indoor type (without rain shed), QTIII 3rd generation technology

 

  1. Core Specification Parameters

Электрические параметры

ПараметрЦенитьОписание
Номинальное напряжение8.7/15 кВ (Макс 20 кВ)Suitable for medium voltage power system, соответствует МЭК 60502 стандартный
Maximum System Voltage17.5 кВMeets Class 1 termination requirements of IEEE 48-1990 стандартный
Applicable Cable TypeWire shield / Tape shield XLPE/EPR insulated power cableDedicated for polymer insulated cables; not applicable to oil-impregnated paper insulated cables
Insulation Outer Diameter Range16.0–28.0 mmTypical insulation outer diameter for 3×70 mm² cable (приблизительно. 18–22 mm)
Power Frequency Withstand Voltage45 кВ / 1 минFactory test standard to ensure insulation reliability
Partial Discharge≤5 pCQTIII 3rd generation technology, better performance than QTII series (≤10 pC)
Switch Impulse Withstand Voltage95 кВSatisfies system overvoltage protection requirements

Механический & Параметры окружающей среды

ПараметрЦенитьОписание
Изоляционный материалHigh dielectric constant creepage-resistant silicone rubberPermanent radial pressure, excellent weather resistance and aging resistance
Защита от проникновенияIP68Fully dustproof and waterproof, suitable for humid indoor environments
Рабочая температура-40℃ ~ +90℃Широкий температурный диапазон, adapts to extreme climatic conditions
Механический срок службы≥30 yearsMaintenance-free design with long service life
Способ установкиCold shrink type (no heating tools required)Automatically shrinks by pulling out the support core rope for easy installation
МассаПриблизительно. 0.8 kg/setComplete with all components, convenient for on-site installation
ЦветЧерныйStandard industrial color, stain-resistant

Applicable Cable Parameters

ПараметрОбласть примененияПримечания
Сечение проводника3×70–120 mm²Suitable for mainstream medium voltage distribution cable cross-sections
Conductor MaterialМедь / AluminumCompatible with two mainstream conductor materials, no special model required
Insulation Thickness8–12 mmStandard insulation thickness for 15kV cables
Shield TypeBraided copper wire shield / Wrapped copper tape shieldCompatible with two common shielding structures
Overall Cable Outer Diameter35–50 ммTypical outer diameter range for 3-core cables
  1. Accessory List
Название аксессуараКоличествоЦель
QTIII Cold Shrink Termination Body (with integrated stress control)3 pcsProvide insulation and stress control, grease-free design
Cold Shrink Branch Seal Sleeve1 pcSeal cable branch to prevent moisture ingress
Constant Force Spring Grounding Device3 pcsShield layer grounding connection, no welding or copper binding wire required
Copper Mesh Grounding Wire3 pcsShield layer grounding connection to ensure reliable grounding
Phase Color Marker (Yellow/Green/Red)3 наборыPhase identification, compliant with power safety regulations
Cleaning Kit (CC-2)1 setPre-clean cable surface to remove oil stains and impurities
Sealing Strip6 pcsSeal termination top and cable branch to enhance waterproof performance
Installation Instruction Manual1 copyDetailed illustrated installation guidance
Support Core Rope Pulling Tool1 pcAssist steady rope pulling during installation to avoid termination distortion
  1. Competitor & Межбрендовое сравнение
БрендМодельОсновное отличиеСценарий применения
Original 3M7622-S-4Outdoor type with rain shed, 15кВ, 3×70–120 mm²Outdoor medium voltage distribution equipment connection
Original 3M5601PST-G-CNQTII 2nd generation, 15кВ, 3×35–70 mm²Indoor power distribution, budget-limited projects
АББCold Shrink Termination SeriesSimilar structure, slightly higher price, same applicable rangePower system supporting, brand preference
ШнайдерCold Shrink Termination SeriesDifferent stress control design, slight difference in installation stepsIndustrial automation system supporting
Domestic AlternativeChangyuan CYLS-15/3.1Price about 1/2–2/3 of 3M, performance meets national standardsBudget-sensitive projects, non-critical circuits
Domestic AlternativeWalen WRS-15/3.1Высокая стоимость исполнения, same applicable rangeGeneral distribution projects, bulk procurement
  1. Рекомендации по выбору & Решения по замене

5.1 Ключевые параметры выбора

Voltage Level Matching: Confirm system voltage is 8.7/15kV; not applicable for systems below 10kV or above 20kV.

Cable Specification Confirmation:

Сечение проводника: Well compatible within 3×70–120 mm² range.

Insulation outer diameter: Must be within 16.0–28.0 mm with tolerance ≤±1mm, ensuring sufficient radial compression of cold shrink termination.

Shield type: Only applicable to wire/tape shielded cables; not for non-shielded or aluminum sheathed cables.

Среда установки:

Indoor application: Select 7622PST-G2 (indoor type), compact structure without rain shed.

Outdoor application: Choose outdoor type 7622-S-4 with UV resistance and weatherability.

Installation Tools: No heating tools required; only basic electrician tools and cleaning supplies, single-person installation available.

5.2 Recommended Replacement Solutions

Сценарий примененияRecommended Replacement ModelПреимущества
Direct replacement with same specification3M 7622PST-G2 (3×70–120 mm² applicable)Original genuine product, полностью совместим, QTIII 3rd generation technology
Small cross-section adaptation3M 7620PST-G1 (3×35–70 mm² applicable)Fits smaller cross-section cables with lower cost
Large cross-section upgrade3M 7624PST-G1 (3×150–240 mm² applicable)Compatible with larger cross-section cables, reserved for future capacity expansion
Outdoor installation3M 7622-S-4Dedicated outdoor type with rain shed, excellent UV resistance
Cost optimizationChangyuan CYLS-15/3.1High-quality domestic alternative, obvious price advantage, performance meets national standards

5.3 Меры предосторожности при установке

  1. Cable Pre-treatment

Thoroughly clean cable surface with 3M CC-2 cleaning kit to remove oil stains and oxide layer.

Keep smooth transition at shield cut-off position to avoid tip discharge; professional tools are recommended.

  1. Installation Procedure

QTIII series: Integrated design without additional stress control mastic required; install branch seal sleeve first, then cold shrink termination body.

Pull the core rope steadily at constant speed to avoid termination distortion and ensure close fitting with cable surface.

  1. Safety Regulations

Installers must hold valid medium voltage cable construction qualification; confirm cable power off and grounding before construction.

Construction site shall be dry and clean; avoid installation in rainy or humid conditions.

  1. Quality Control

Perform insulation resistance test (≥1000 MΩ) and partial discharge test (≤5 pC) after installation.

Record installation date and test data for future maintenance and traceability.

  1. Product Features Summary
  2. QTIII 3rd Generation Technology: Grease-free application, lower partial discharge (≤5 pC), easier installation and higher reliability.
  3. Интегрированный дизайн: Built-in stress control unit effectively reduces partial discharge risk and improves insulation reliability.
  4. Простая установка: Cold shrink technology requires no heating tools; single-person installation saves construction time and cost.
  5. Strong Environmental Adaptability: Operating temperature -40℃~+90℃, IP68 protection grade, suitable for various harsh indoor environments.
  6. Wide Compatibility: Compatible with multiple specifications of XLPE/EPR insulated cables with high versatility, reducing inventory pressure.
  7. Maintenance-free Design: Silicone rubber provides permanent radial pressure without regular inspection, lowering operation and maintenance costs.