ABB 2UEA001345 Phase Module Kit

АББ 2UEA001345 (ACS 2040-PMK1000) 4kV Phase Module Kit

ABB 2UEA001345 is a dedicated phase module kit for ACS 2040 series 4kV medium-voltage frequency converters. It serves as the core power unit of the ACS2000 medium-voltage drive system, adopting 3-level IGBT topology. It is applicable to 4kV power grid systems with rated power ranging from 300-1000HP (225-750кВт).

Its core strengths include high-reliability design (MTBF>100,000 hours), выходной сигнал с низким уровнем гармоник (compliant with IEEE 519 стандартный), modular structure for easy maintenance and replacement, and wide operating temperature range (-10℃ ~ +40 ℃). It is perfectly suited for general industrial loads such as fans, water pumps and compressors, which can effectively improve system energy efficiency (20%-40% энергосбережение) and reduce maintenance costs.

  1. Пояснение кода модели
РазделКодОпределение
Серия продуктов2UEASeries code for ABB medium-voltage inverter power modules (2UEA=ACS 2040 ряд, 2UEB=ACS 2000 ряд)
Part Number1345Unique identification code of phase module kit, corresponding to model ACS 2040-PMK1000
Применимое напряжение4кВMatches 4000V medium-voltage power grid system
Тип продуктаPMK1000Phase Module Kit, номинальный ток: 1000А
Применимая системаACS 2040Compatible with ABB ACS 2040 series medium-voltage inverters

Номер заказа: 2UEA001345 (Standard single packing)

Matching Model: 2UEA001141 (Complementary phase module of the same series)

  1. Main Technical Specifications
КатегорияЭлементПараметрПримечания
Основная информацияТип продукта4kV Medium Voltage Inverter Phase Module Kit3-level IGBT topology, integrated drive and protection circuits
Applicable InverterACS 2040 Ряд (ACS2000 Platform)Compatible with Frame 1 размер (300-1000HP)
Номинальное напряжение4кВ (4000В)Operating voltage range: 3.6~4.4kV
Номинальный ток1000АMax peak current: 2000А (2 times rated value)
Power DevicesIGBT TypeHigh-voltage IGBT Module1700V/1200A, ABB customized version
Topology3-level NPC (Neutral Point Clamped)Reduce dv/dt and motor insulation stress
Cooling ModeForced Air CoolingBuilt-in cooling fan, redundant design supported
Электрические параметрыInput Frequency50/60Гц, ±5%Compatible with global power grid standards
Switching Frequency2~8kHz (Регулируемый)Balance energy efficiency and noise performance
Потеря мощностиПриблизительно. 1.2kW per moduleUnder typical working conditions
Класс изоляцииOvervoltage Category IV (МЭК 60664)Meet insulation requirements of medium-voltage systems
Mechanical ParametersИзмерение (L×W×H)650×450×320mmStandard Frame 1 размер
Net Weight48.5кгБез упаковки
Класс защитыIP20Suitable for cabinet installation
Функции защитыЗащита от перегрузки по току2000А (2 times rated)Short-circuit response time <10μs
Защита от перенапряжения4.4кВDC bus overvoltage protection
Over-temperature Protection100℃IGBT module overtemperature protection
Защита от пониженного напряжения3.6кВGrid undervoltage protection
Сертификаты & СогласиеCE CertificateДаCompliant with EN 61800-5-1
UL CertificateДаMeet North American medium-voltage equipment standards
IEEE 519 СогласиеДаTotal harmonic distortion <5%
  1. Full Model List of ACS 2040 Series Phase Modules
МодельНомер заказа.Номинальное напряжениеНоминальный токApplicable InverterПримечания
ACS 2040-PMK10002UEA0013454кВ1000АACS 2040 Рамка 1Standard phase module
ACS 2040-PMK10002UEA0011414кВ1000АACS 2040 Рамка 1Complementary phase module
ACS 2040-PMK12002UEA0013464кВ1200АACS 2040 Рамка 1High current version
ACS 2040-PMK8002UEA0013474кВ800АACS 2040 Рамка 1Low current version
ACS 2040-PMK1000-6kV2UEA0013486кВ1000АACS 2040 Рамка 26kV dedicated version
  1. Замена & Equivalent Models

4.1 Internal ABB Replacement

Old ModelNew ModelReplacement Description
ACS 1040-PMK1000ACS 2040-PMK1000 (2UEA001345)Upgraded to 3-level topology, efficiency increased by 2%, harmonic distortion reduced by 30%
ACS 2040-PMK800 (2UEA001347)ACS 2040-PMK1000 (2UEA001345)Higher current model in the same series, wider power coverage

4.2 Cross-brand Equivalent Products

БрендЭквивалентная модельПреимущества
СименсSINAMICS GM150 Power ModuleSuperior 3-level topology, lower dv/dt, better motor insulation protection
Шнайдер ЭлектрикAltivar 6100 Medium Voltage ModuleEasier maintenance with modular design, higher MTBF (>100,000 hours)
Mitsubishi ElectricMV-VFD Power ModuleWider applicable voltage range (3.6-4.4кВ), stronger environmental adaptability
  1. Сценарии применения & Industry Cases

5.1 Recommended Applications

Тип приложенияTypical Working ConditionsОсновные преимущества
Industrial FansPower plant induced draft fans, cement plant kiln fans, steel plant dust removal fansWide speed regulation range (0.1-100Гц), 30%-40% энергосбережение
Industrial Water PumpsWater plant high-pressure water supply pumps, mine drainage pumps, petrochemical circulating pumpsSoft start without impact, reduce pipeline stress and extend service life
КомпрессорыВоздушные компрессоры, natural gas compressors, холодильные компрессорыPrecise pressure control, reduce no-load loss and improve energy efficiency
КонвейерыLong-distance mine conveyors, port container conveyorsSmooth speed regulation, avoid material accumulation and mechanical wear
General Industrial EquipmentМиксеры, дробилки, экструдеры, и т. д..Modular design for convenient maintenance, MTBF>100,000 hours

5.2 Not Recommended Usage Scenarios

Explosion-proof areas (non-explosion-proof structure, customized version required)

Морские платформы (additional anti-corrosion treatment needed)

Ultra-high voltage systems above 4.4kV (select 6kV version instead)

Equipment with frequent start-stop operations (more than 10 times per hour, special customized modules recommended)

5.3 Practical Cases

Случай 1: Induced Draft Fan Renovation in Thermal Power Plant

Original system: Fixed-speed motor + baffle adjustment, high energy consumption and severe baffle wear

Renovation solution: ACS 2040 инвертор + 3 sets of 2UEA001345 phase modules (3-фаза)

Effect: Energy consumption reduced by 38%, annual electricity cost saved about 1.8 million RMB, baffle maintenance cycle extended 5 раз

Случай 2: High-pressure Water Supply System for Large Water Plant

Требовать: Constant pressure water supply with large load fluctuation (20%-100%)

Решение: ACS 2040 Рамка 1 (3 pcs 2UEA001345 modules) + PID control system

Effect: Stable pressure deviation within ±0.05MPa, 32% энергосбережение, service life extended by 3 годы

  1. Air Shipment Compliance & Certification Guide

6.1 Shipment Compliance Confirmation

ЭлементСтатусОбъяснение
Built-in Lithium BatteryНетOnly electronic components and IGBT modules equipped
Dangerous Goods ClassificationNon-dangerous goodsCompliant with IATA DGR Class 9, no special shipping restrictions
Transport RestrictionsНиктоCan be shipped as ordinary industrial equipment
Стандарт упаковкиStandard shockproof packageFix IGBT modules firmly to avoid damage during transit
Температурный диапазон-20℃ ~ +50℃Avoid extreme temperature during transportation

6.2 Certification Document Acquisition

CE Certificate: Available for download on official ABB website (Document ID: ACS2000-PHTC01U-EN)

UL Certificate: Apply via ABB global technical support center

Manufacturer Declaration: Including EMC, safety and RoHS compliance statements

  1. Рекомендации по выбору & Quick Rules

Правила выбора

  1. Согласование напряжения: 2UEA001345 for 4kV systems; choose 2UEA001348 for 6kV systems
  2. Текущий выбор: 1000A standard (PMK1000), 800A low current (PMK800), 1200A high current (PMK1200)
  3. Совместимость системы: Only applicable to ACS 2040 ряд (ACS2000 platform) Рамка 1 размер
  4. Quantity Matching: 3 phase modules required for one 3-phase inverter, 1 spare module is recommended
  5. Maintenance Tips: Regularly inspect cooling fans, replace IGBT modules every 5 years to ensure stable insulation performance
  6. Main Accessories & Рекомендуемая конфигурация
Название аксессуараМодельФункция
Блок управленияACS 2040-CUCore control unit matched with phase modules
Охлаждающий вентилятор3HAC031683-001Special cooling fan for phase modules, support redundant operation
Drive Board3HAC031684-001IGBT drive circuit with integrated protection functions
Voltage Sensor3HAC031685-0014kV system voltage monitoring, realize over/under voltage protection
Current Sensor3HAC031686-0011000A current detection, сверхток & защита от короткого замыкания
Installation Kit3HAC031687-001Including fixing bolts, gaskets, insulating sleeves etc.

Предыдущий:

Оставить ответ

Оставить сообщение