Carlo Gavazzi Conductive Level Sensor 481046

Карло Гавацци, VNY 4 NS/NT Conductive Level Sensor (Item No.: 481046)

Карло Гавацци, VNY 4 NS/NT Conductive Level Sensor (Item No.: 481046)

Модельный сегментОписание
VNYСерия продуктов: Conductive level probe; VNY series features threaded connection with PBTP housing and non-insulated electrodes
4Electrode quantity: 4 электроды, supporting multi-level monitoring (Высокий / Середина / Низкий / Ultra-low)
НСElectrode type: Non-Isolated, suitable for general conductive liquid measurement
NTТип подключения: Винтовые клеммы, convenient for field wiring
481046Global unique item / order number, official Carlo Gavazzi part identifier
  1. Full Core Technical Specifications
Категория параметраТехнические характеристикиПримечания
Basic InfoConductive level sensor for multi-point level control of conductive liquidsMust be used with amplifier relays (SV series, S195/196, ELA/ELC/ELD)
Номер заказа.481046 (corresponds to model VNY 4 NS/NT)Order strictly by this part number
ПроизводительКарло ГавацциWell-known brand in industrial automation sensors
Electrode Configuration4 non-insulated electrodes, AISI316 stainless steel (DIN1.4401)Diameter 5mm, standard length 100cm (field-cuttable)
Материал корпусаPBTP engineering plasticCorrosion-resistant for industrial environments
Тип монтажа1 1/2″ pipe thread (ISO 228/1-G1 1/2″)Standard industrial pipeline mounting, fixed with VM15 nut
Connection MethodScrew terminal connection (NT)More suitable for vibrating environments than cable connection, простота обслуживания
Защита от проникновенияIP67Dust-tight and waterproof, submersible in liquid
Рабочая температура0°C ~ 90°C (32°F ~ 194°F)Compatible with most industrial liquid temperature ranges
Температура хранения-25°C ~ 100°C (-13°F ~ 212°F)Adaptable to extreme transportation and storage conditions
Working Pressure10 бар (@ 60°C)Suitable for medium and high-pressure tank applications
Cable SpecificationNo built-in cable (screw terminal type)Customer-supplied cable recommended; shielded cable preferred to reduce interference
СертификатыCE certified (соответствует МЭК 529)Meets EU industrial safety requirements
РазмерыElectrode diameter 5mm, total length approx. 100смElectrode length can be cut on-site according to actual liquid level
МассаПриблизительно. 0.8кгLightweight design for easy installation and maintenance
  1. VNY Series Full Model List
Item No.МодельElectrode QtyElectrode TypeТип подключенияМатериал корпусаMounting ThreadСпециальные возможности
481046VNY 4 NS/NT4Non-Isolated (НС)Screw Terminal (NT)PBTP1 1/2″Multi-level control, general industrial use
481043VNY 1 NS/NT1Non-Isolated (НС)Screw Terminal (NT)PBTP1 1/2″Single-point level detection, экономически эффективный
481044VNY 2 NS/NT2Non-Isolated (НС)Screw Terminal (NT)PBTP1 1/2″Two-point high/low level control
481045VNY 3 NS/NT3Non-Isolated (НС)Screw Terminal (NT)PBTP1 1/2″Three-point high/medium/low level control
481047VNYI 4 IS/NT4Insulated (IS)Screw Terminal (NT)PBTP1 1/2″PE insulated electrodes, anti-clinging liquid interference
481042VNY 1 NS/CB1Non-Isolated (НС)Cable Connection (КБ)PBTP1 1/2″2m fixed cable length, suitable for long-distance installation
  1. Замена & Cross Reference

4.1 Same Brand Direct Replacement

Оригинальная модельЗапасная модельReplacement DescriptionСценарий применения
VNY 4 NS/NT (481046)VNYI 4 IS/NTUpgraded insulated electrodes to avoid false triggering from liquid clingingViscous liquids and wall-adhering media (syrup, lubricating oil)
VNY 4 NS/NT (481046)VNY 4 NS/CBChanged to cable connection for heavy vibration environmentsLevel monitoring for vibrating equipment such as pump sets and compressors
VNY 4 NS/NT (481046)VN 4 NS/CBCable type with PBTP housing and 1 1/2″ threadGeneral industrial environments, better cost performance

4.2 Cross-Brand Equivalent Models

Карло ГавацциШнайдерОмронPepperl+FuchsОсновные различия
VNY 4 NS/NT (481046)XPSAK3711D4CC-4000FTL20-0020Carlo Gavazzi adopts superior AISI316 material with IP67 protection
Schneider higher integration; Omron more cost-competitive
Field-cuttable electrode length for better adaptability
Pepperl+Fuchs suitable for explosion-proof areas; Carlo Gavazzi for general industry
  1. Application Industries & Typical Cases

Recommended Applications

  1. Process Industry: Tank level monitoring in chemical, petrochemical and pharmaceutical industries to prevent overflow and dry running
  2. Еда & Beverage: Raw material and finished tank level control for beer, beverage and dairy production lines
  3. Очистка воды: Level monitoring for sedimentation tanks and reaction tanks in waterworks and wastewater plants
  4. Energy Sector: Level protection for cooling and lubrication systems in power plants and substations
  5. Mechanical Manufacturing: Oil level monitoring for hydraulic and lubrication systems to avoid equipment damage
  6. Marine Industry: Level measurement for ship ballast tanks, fuel tanks and fresh water tanks

 

Типичные случаи применения

  1. Chemical Plant Acid & Alkali Tank Level Control System

Application Goal: Monitor high/low levels of three 100m³ acid and alkali tanks to prevent overflow and pump dry running

Основные преимущества: AISI316 corrosion-resistant electrodes; IP67 suitable for outdoor installation; 4-electrode enables multi-point level monitoring

System Configuration: VNY 4 NS/NT (481046) × 3 + ELA amplifier relay + PLC control system + HMI touch screen

Operation Effect: Level control accuracy ±1cm, false alarm rate reduced by 95%, maintenance cost cut by 60%

 

  1. Automobile Factory Hydraulic Station Oil Level Monitoring System

Application Goal: Monitor oil levels of 5 hydraulic stations to ensure stable operation and prevent oil shortage failure

Основные преимущества: Vibration-resistant screw terminal design; oil-resistant PBTP housing; field-cuttable electrodes adaptable to various tank heights

System Configuration: VNY 4 NS/NT (481046) × 5 + S196 amplifier + indicator light + buzzer

Operation Effect: Equipment failure rate reduced by 40%, maintenance cycle doubled

Not Recommended Applications

Non-conductive liquids: Such as pure oil, alcohol, acetone; not detectable by conductive sensors

High temperature >90°С: Adopt VPP series (up to 100°C) or high-temperature versions

Рабочее давление >10 бар: Special high-pressure level sensor required

Strong corrosive media: Concentrated hydrochloric acid, concentrated sulfuric acid; use VPP series with PVDF electrodes or anti-corrosion coated models

  1. Установка & Wiring Guidelines

Требования к установке

  1. Mounting Position: Install on tank top or side, away from inlet ports and agitators; ensure vertical electrode immersion
  2. Electrode Cutting: Cut electrode length on-site according to actual liquid level; deburr the end after cutting for accuracy
  3. Sealing: Use suitable gaskets (PTFE recommended) for leak-tight installation to maintain IP67 protection
  4. Earthing Requirement: Conductive tank body can serve as common electrode; non-conductive tanks require separate common electrode grounding
  5. Spacing Requirement: Keep ≥50mm between electrodes and between electrodes and tank wall to avoid signal interference

Core Terminal Definition

Терминал №.ФункцияТипПримечания
E1/E2/E3/E4Electrode 1–4Signal InputCorrespond to four level detection points; freely assign high/medium/low functions
КОМCommon TerminalSignal ReferenceConnect to tank wall or separate common electrode to complete circuit
+V/-VИсточник питания24В постоянного токаRequires matching amplifier relay; sensor itself needs no independent power supply
NO/NC/COMРелейный выходSwitch ContactProvided by amplifier relay for valve control or alarm output

Ключевые моменты ввода в эксплуатацию

  1. Electrode Setting: Define corresponding level heights for each electrode (например. E1=Low, E2=Medium, E3=High, E4=Ultra-high)
  2. Sensitivity Adjustment: Adjust amplifier relay sensitivity to avoid false triggering caused by foam or clinging liquid
  3. Функциональный тест: Simulate level changes to verify accurate switching action and response time
  4. Insulation Check: For non-insulated type, ensure no short circuit between electrodes and tank wall; check insulation integrity for insulated type
  5. Environmental Adaptation Test: Verify long-term stability within rated temperature and pressure range
  6. Правила выбора & Quick Reference

Рекомендации по выбору

  1. Liquid Type: Choose VNY series for conductive liquids; use capacitive or ultrasonic sensors for non-conductive liquids
  2. Electrode Quantity: 1=single point, 2=high/low, 3=high/medium/low, 4=four-point full control
  3. Electrode Insulation: NS for normal liquids; IS insulated type for viscous wall-adhering media
  4. Тип подключения: NT screw terminal for vibration environments; CB cable type for long-distance installation
  5. Mounting Thread: 1 1/2″ for large tanks, 1″ for medium, 1/2″ for small containers
  6. Температура & Pressure: VNY for 0–90°C / 10 бар; VPP for higher temperature; special models for higher pressure
  7. Соблюдение требований в области авиаперевозок & Сертификаты

Соблюдение требований в области авиаперевозок: No lithium battery / supercapacitor. Pure mechanical and metallic structure, compliant with IATA DGR Class 9, shippable as standard general cargo.

Сертификаты:

– CE: Соответствует МЭК 529 ingress protection standard

– РоХС: EU RoHS compliant, free of hazardous heavy metals

Material Certification: AISI316 stainless steel electrodes meet food-contact grade requirements for food & beverage industry

Environmental Compliance: Compliant with REACH regulations for global market access

  1. Покупка & Logistics Information
Purchase ItemПодробности
минимальный заказ1 единица
Время выполненияStandard 5–7 days; Express 2–3 days
УпаковкаIndividual carton with installation manual, sealing gasket and mounting nut
Гарантия12 months from commissioning acceptance
Recommended SparesSame model sensor, electrode extension joint (VD1), mounting nut (VM15)
Matching AccessoriesCarlo Gavazzi ELA/ELC/ELD amplifier relay, ПЛК, HMI touch screen