T6V 800 PR221DS|ABB Tmax T6 Series High Performance Moulded Case Circuit Breaker (MCCB)

Полная модель: T6V 800 PR221DS-LS/I In=800 (Common Order Codes: 1SDA069432R1, 1SDA069429R1, 3P/4P selectable)

Бренд: АББ (SACE Tmax Series)

  1. Detailed Model Interpretation
Модельный сегментЗначениеКлюч Описание
T6Series DesignationTmax T6 series, frame current 800A, suitable for medium and high voltage power distribution systems
ВКласс отключающей способностиClass V, ultra-high breaking capacity: 120kA at 400V, 200kA at 220V
800Номинальный ток800А (same as frame current)
PR221DSTrip Unit TypeElectronic intelligent trip unit with LS/I protection (Long-time delay L, Short-time delay S, Instantaneous I)
LS/IКонфигурация защитыStandard three-stage protection; earth fault protection optional (extra configuration required)
F FМонтаж / СвязьFirst F: Фиксированный монтаж; Second F: Front connection
  1. Основные технические параметры
ЭлементСпецификацияПримечания
Номинальное напряжение (Уэ)690В иSuitable for industrial high-voltage power distribution systems
Номинальное напряжение изоляции (Уи)1000В иHigher than rated operating voltage, large safety margin
Максимальная отключающая способность (Ику)120кА при 400 В, 200kA@220VHighest Class V, подходит для суровых промышленных условий
Номинальный рабочий ток (В)800АMaximum continuous operating current
поляки3P/4P selectable3P for three-phase circuits, 4P includes neutral protection
Характеристика отключенияLS/I three-stage protectionLong-time delay inverse time, short-time / instantaneous definite time
Тип монтажаЗафиксированныйDraw-out type also available (special model required)
Тип подключенияFront connectionCompatible with cables or busbars
Degree of ProtectionIP30Standard switchgear installation protection
Применимый стандартМЭК 60947-2International standard for low-voltage switchgear
  1. Ключевые особенности & Приложения

Основные преимущества

  1. Ultra-high breaking capacity: Class V can withstand severe short-circuit faults and ensure system safety
  2. Intelligent protection: PR221DS trip unit provides accurate overload and short-circuit protection with adjustable parameters
  3. Reliable and durable: ABB Tmax series design, suitable for frequent operation and harsh industrial environments
  4. Flexible extension: Supports various accessories (вспомогательные контакты, контакты сигнализации, расцепитель минимального напряжения, и т. д.)

Типичные применения

Main power distribution systems in large industrial plants

690V high-voltage Motor Control Centers (МСС)

Power supply for data centers and critical infrastructure

Combiner box protection for new energy power systems (PV, wind power)

Marine and offshore platform power distribution systems

  1. Reference Replacement Models

Same-brand Upgrades / Замены

МодельРазрывная способностьTrip TypeПриложение
T6V 800 PR222DS-LSIG120кА при 400 ВWith earth fault protection (Г)Systems requiring earth fault detection
T6V 800 PR223DS120кА при 400 ВAdvanced intelligent trip unitApplications requiring remote monitoring and communication
T6S 800 PR221DS70кА при 400 ВStandard breaking capacityGeneral industrial power distribution, более низкая стоимость

Кросс-брендовые альтернативы

БрендМодельКлючевые параметры соответствия
ШнайдерMasterpact MT25H1 800A800А, 120kA breaking, three-stage protection
Сименс3WL1210-3BB36-4GA4800А, 100kA breaking, intelligent trip unit
MitsubishiNF800-SEW800А, 100kA breaking, electronic trip unit
  1. Примечания к выбору
  2. Breaking capacity matching: Select V/S/H/N/L classes based on system short-circuit current calculation
  3. Protection function selection: Basic LS/I meets most needs; choose LSIG for earth fault protection
  4. Mounting type: Fixed for standard switchgear, draw-out for easy maintenance and replacement
  5. Accessory configuration: Select auxiliary contacts, контакты сигнализации, motor operators, и т. д., according to control requirements
  6. Voltage compatibility: T6V suitable for systems up to 690V; use dedicated 1000V series (например, T6L) for higher voltages