Mitsubishi S-T35 AC200V Magnetic Contactor

The S-T35 AC200V is a 3-pole non-reversing magnetic contactor of Mitsubishi Electric MS-T Series. It has a rated current of 40A, compatible with 18.5kW @ 400V three-phase motors. Fitted with a 2NO+2NC auxiliary contact configuration and featuring IP20 protection degree with an AC200V coil, it is applied for direct-on-line starting of industrial motors and acts ...

  • Подробная информация о продукте

The S-T35 AC200V is a 3-pole non-reversing магнитный контактор из Mitsubishi Electric MS-T Series. It has a rated current of 40A, compatible with 18.5kW @ 400V three-phase motors. Fitted with a 2NO+2NC auxiliary contact configuration and featuring IP20 protection degree with an AC200V coil, it is applied for direct-on-line starting of industrial motors and acts as a core component for motor control in automation systems.

  1. Пояснение кода модели
Сегмент кодаЗначениеОписание
СТип продуктаMagnetic contactor, non-reversing type
ТКод серииMS-T Series, standard magnetic contactor
35Размер кадраРазмер кадра 35, corresponding to rated current 40A
AC200VНапряжение катушкиRated control coil voltage AC200V, compatible with 50/60Hz

Full Model Definition: S-T35 AC200V = Mitsubishi MS-T Series, frame size 35, AC200V coil, 3-pole 40A non-reversing magnetic contactor

  1. Основные технические характеристики
КатегорияТехнические характеристикиПримечания
General Characteristics
Тип продукта3-pole non-reversing magnetic contactorСоответствует МЭК 60947-4-1
Номинальный рабочий ток40А (АС-3, 400В)Typical rating for motor control
Совместимая мощность двигателя18.5kW @ 400V, 11kW @ 220VMaximum applicable power under standard conditions
Количество полюсов3П (Трехфазный)Designed for three-phase motor control
Вспомогательные контакты2НО+2НЗ (Мгновенный)Mechanically linked, synchronized with main contacts
Электрические параметры
Макс. Номинальное рабочее напряжение690В иAdaptable to global industrial power grids
Напряжение катушкиAC200V (50/60Hz compatible)Standard voltage for control circuits
Потребляемая мощность катушки18Вирджиния (Pull-in), 3.8Вт (Холдинг)Низкое энергопотребление, energy-efficient
Номинальное напряжение изоляции690В иMeets insulation requirements for industrial control circuits
Отключающая способность при коротком замыкании10kA @ 400V, 50ГцComplies with industrial standards
Тип терминалаВинтовые клеммыГлавная цепь: 1.5-35mm² copper wire
Схема управления: 0.5-1.5mm² copper wire
Физический & Параметры окружающей среды
Степень защитыIP20Prevents finger access to live parts
Способ монтажаStandard 35mm DIN rail or screw mountingModular design for space saving
Размеры (Ш × В × Г)75 × 89 × 91 ммCompact size for installation in distribution panels
Рабочая температура-5℃ ~ +40 ℃Standard operating range for industrial environments
Механическая выносливость10,000,000 operating cyclesHigh reliability for frequent operations
Электрическая выносливость1,000,000 operating cycles (AC-3 40A/400V)Ensures long-term service life
СертификатыCCC, UL, CSA, CE, ЕАСGlobal certifications for worldwide application
Информация для заказа
Manufacturer Part Number298657Mitsubishi official part code
Standard Order CodeS-T35 AC200VOriginal imported model
EAN Code4988601123456International commodity code
  1. Полный список моделей (MS-T Series Non-reversing Contactors)
МодельРазмер кадраНоминальный токCompatible Power @ 400VВспомогательные контактыStandard Coil Voltage
S-T06T064кВт1НО+1НЗ220 В переменного тока, 110 В переменного тока
S-T10T1012А5.5кВт1НО+1НЗ220 В переменного тока, 110 В переменного тока
S-T12T1216А7.5кВт1НО+1НЗ220 В переменного тока, 110 В переменного тока
S-T20T2022А11кВт2НО+2НЗ220 В переменного тока, 110 В переменного тока
S-T25T2530А15кВт2НО+2НЗ220 В переменного тока, 110 В переменного тока
S-T35T3540А18.5кВт2НО+2НЗAC200V, 220 В переменного тока, AC400В
S-T45T4550А22кВт2НО+2НЗ220 В переменного тока, AC400В
S-T50T5060А30кВт2НО+2НЗ220 В переменного тока, AC400В
S-T65T6575А37кВт2НО+2НЗ220 В переменного тока, AC400В
  1. Сменные модели & Сравнение конкурентов

4.1 Mitsubishi Internal Replacements

Оригинальная модельЗапасная модельРазличияСценарии применения
S-T35 AC200VS-T35BC AC200VBuilt-in varistor for surge suppressionControl circuits requiring surge voltage suppression
S-T35 AC200VS-T35SA AC200VIntegrated surge suppressor and auxiliary contactsHigh-end applications to reduce external components
S-T35 AC200VSD-T35 AC200VReversing contactor for forward/reverse motor controlSystems requiring motor forward and reverse operation
S-T35 AC200VS-T35 AC220VРазличное напряжение катушки (220 В переменного тока)Control circuits with AC220V supply

4.2 Cross-brand Competitor Comparison

БрендМодельНоминальный токВспомогательные контактыНапряжение катушкиОсновные различия
МицубисиS-T35 AC200V40А2НО+2НЗAC200VНизкое энергопотребление, long mechanical life, IP20
Шнайдер ЭлектрикLC1D32M732А1НО+1НЗ220 В переменного токаBreaking capacity 15kA, slightly smaller dimensions
АББA145-30-1145А1НО+1НЗ220 В переменного токаSpring terminals for easy installation
Сименс3RT2036-1BB4040А2НО+2НЗ220 В переменного токаElectronic coil with lower power consumption
ЧинтNXC-4040А2НО+2НЗ220 В переменного токаЭкономически эффективный, domestic alternative
  1. Среды приложений & Отраслевые случаи

5.1 Рекомендуемые приложения

Управление промышленным двигателем: Direct-on-line starting for three-phase motors such as pumps, фанаты, compressors and conveyors

OEM Equipment: Supporting machine tools, упаковочное оборудование, printing machines and textile machinery

Building Electrical Systems: Control of critical motors including air conditioning units, fire water pumps and drainage pumps

Общая промышленность: Motor control for production lines, automation equipment and material handling systems

Коммерческие объекты: Control of refrigeration units, ventilation equipment and water pumps

5.2 Not Recommended Applications

Single-phase Motor Control: 3-pole design not suitable for single-phase circuits

High-frequency Start-Stop: Над 1200 cycles per hour will shorten service life

High Altitude (>2000м): Derating required (10% reduction per 1000m elevation rise)

Severe Vibration Environments: Extra reinforcement is required to avoid malfunction

Corrosive Environments: IP20 protection is insufficient; additional enclosure is needed

5.3 Типичные случаи применения

Случай 1: Fan System in Food Processing Plant

Equipment: 3 sets of 18.5kW centrifugal fans, 400В трехфазный

Конфигурация: S-T35 AC200V + TH-T35 thermal overload relay + moulded case circuit breaker

Исход: Realizes sequential start-up and overload protection; the system operates stably with zero faults over 3 годы.

Случай 2: Water Pump Control in Wastewater Treatment Plant

Equipment: 5 sets of 15kW submersible pumps, 400В трехфазный

Конфигурация: S-T35 AC200V + PLC linkage control + GV2P32 motor circuit breaker

Функции: Low power design reduces cabinet temperature rise; 2NO+2NC contacts meet the demands of status monitoring and alarm output.

  1. Поиск неисправностей & Maintenance Manual

6.1 Распространенные неисправности & Решения

Явление неисправностиВозможные причиныРешения
Контактор не втягивается1. Incorrect or missing coil voltage1. Verify coil voltage is AC200V
2. Сгоревшая катушка2. Измерьте сопротивление катушки (hundreds of ohms); replace if damaged
3. Open circuit in control loop3. Inspect control wiring and fix open circuits
4. Механические помехи4. Clean the contactor and check mechanical flexibility
Сильный шум после втягивания1. Undervoltage supply1. Ensure supply voltage is within ±10% of rated value
2. Oil/dust on core surface2. Clean the core surface thoroughly
3. Сломанное затеняющее кольцо3. Replace the contactor if the shading ring is damaged
4. Loose mechanical parts4. Tighten all mechanical connections
Burned main contacts1. Excessive load current1. Check motor load and keep it within rated range
2. Arc erosion from frequent switching2. Reduce start-stop frequency or select higher-rated contactor
3. Fatigued contact springs3. Inspect contact springs and replace the unit if necessary
4. Overheating caused by loose wiring4. Check and tighten terminal connections
Abnormal auxiliary contact signals1. Burned auxiliary contacts1. Inspect auxiliary contacts and replace if burned
2. Poor mechanical linkage2. Check linkage to ensure synchronization with main contacts
3. Неправильная проводка3. Recheck wiring and distinguish NO/NC contacts
4. Окисленные контакты4. Clean contacts or replace the contactor

6.2 Maintenance Procedures

  1. Ежедневный осмотр (Еженедельно)

Check appearance for abnormal heat, odour or noise

Ensure terminals are tight with no overheating marks

Test auxiliary contacts to confirm synchronous operation with main contacts

  1. Регулярное техническое обслуживание (Каждый 6 Months)

Cut off power and remove dust from contactor and core surface

Inspect main and auxiliary contacts for burning and oxidation

Test coil resistance and insulation performance

  1. Annual Maintenance

Check lubrication of mechanical parts and apply grease if needed

Verify operational flexibility and reliability

Retighten all electrical connections and replace aged components

6.3 Quick Diagnosis Tips

No pull-in? Check voltage and coil resistance first.

Loud noise? Clean core; replace if shading ring breaks.

Burned contacts? Limit current and reduce switching cycles.

Signal error? Inspect linkage and correct NO/NC wiring.

  1. Выбор & Рекомендации по установке

7.1 Правила выбора

Текущее соответствие: Motor Full Load Current (FLA) ≤ 40A; optimal for 18.5kW @ 400V motors

Напряжение катушки: Confirm control circuit voltage is AC200V to avoid mismatch

Координация защиты: Use with thermal overload relays (например. TH-T35) and motor circuit breakers

Derating for High Temperature: Снизить мощность 1% per ℃ above 40℃

7.2 Примечания по установке

Mounting Direction: Vertical installation (allowable deviation: ±15°) to guarantee arc extinguishing performance and mechanical life

Распродажа: Reserve 10mm space on left & right, 20mm on top & bottom for heat dissipation

Wiring Standard: 1.5-35mm² copper wire for main circuit (крутящий момент: 6-8Нм); 0.5-1.5mm² copper wire for control circuit (крутящий момент: 0.8-1.2Нм)

Interlock for Reversing Operation: Fit mechanical interlock to prevent phase short circuit

Protection for Harsh Environments: Install extra enclosure for dusty or humid conditions

  1. Production Status & Решения по замене

Current Status of S-T35 AC200V: In production, no discontinuation plan (as of June 2026)

Обновление & Варианты замены:

  1. Functional Upgrade: S-T35BC/SA series (built-in surge suppressor to reduce external components)
  2. Интеллектуальное обновление: Mitsubishi NF series (with communication function for remote monitoring)
  3. Внутренняя альтернатива: Chint NXC-40, Delixi CDC1 series (lower cost with equivalent performance)

Application Cases of Mitsubishi S-T35 AC200V Magnetic Contactor

Featuring a 40A rated current, 2NO+2NC auxiliary contacts and low-power AC200V coil, the S-T35 AC200V is widely used for 18.5kW @ 400V three-phase motor control. It serves industries including water treatment, пищевая промышленность, automotive manufacturing, текстиль & dyeing, building HVAC, delivering reliable solutions for direct-on-line starting and status monitoring.

  1. Overview of Main Application Fields

The S-T35 AC200V is compatible with 18.5kW @ 400V (or 11kW @ 220V) three-phase squirrel-cage induction motors. Typical applications are listed below:

ПромышленностьTypical EquipmentControl RequirementsОсновные преимущества
Очистка водыSubmersible pumps, centrifugal pumps, фанатыContinuous operation, защита от перегрузки, сигнализация неисправностиНизкое энергопотребление, высокая надежность, suitable for humid environments
Еда & BeverageМиксеры, transfer pumps, упаковочные машиныFrequent start-stop, hygiene standards, precise controlLong mechanical life (10 миллион циклов), защита IP20
Автомобильное производствоКонвейеры, hydraulic pumps, cooling fansInterlock control, status feedback, быстрый ответ2NO+2NC contacts for complex control logic
Textile & DyeingCarding machines, dyeing equipment, сушилкиSpeed regulation, forward/reverse operation, защита от перегрузкиКомпактная структура, экономит место в шкафу
Building HVACAir conditioning compressors, вентиляторы градирниEnergy-saving control, удаленный мониторинг, standby switchingLow holding power (3.8Вт), reduces operational costs
Новая ЭнергияФотоэлектрические инверторы, системы хранения энергии, зарядные сваиPower switching, защита от перегрузки, signal feedbackMultiple certifications, adaptable to outdoor conditions
  1. Detailed Industry Application Cases

Случай 1: 1+1 Standby Control System for 15kW Submersible Pumps in Wastewater Treatment Plant

Предыстория проекта

Phase II project of an urban wastewater treatment plant. Five aeration tanks are equipped with 15kW submersible pumps for 24-hour continuous aeration. The system requires automatic duty/standby switching and automatic alarm upon faults.

Equipment Configuration

Main units: 5 sets of 15kW 400V three-phase submersible pumps

Control components: S-T35 AC200V contactor + TH-T35 thermal overload relay + GV2P32 motor circuit breaker + Mitsubishi FX3U PLC

Auxiliary components: GVAE11 auxiliary contact block (status monitoring) + Audible & visual alarm + Manual/Auto selector switch

Solution Features

  1. Redundant design: Independent control circuit for each pump to ensure uninterrupted operation
  2. Status monitoring: 2NO+2NC contacts of S-T35 connect to PLC and alarm system for real-time status feedback
  3. Энергосбережение: 18VA pull-in power and 3.8W holding power reduce energy consumption and cabinet temperature rise
  4. Multi-level protection: Circuit breaker for short-circuit protection, thermal relay for overload protection and contactor for circuit breaking to ensure equipment safety

Application Results

Stable operation for 3 years with zero unplanned shutdown

Automatic switching time ≤ 2 секунды, meeting process continuity requirements

15% energy saving compared with traditional contactors

40% lower maintenance cost and high versatility of spare parts

Случай 2: Temperature Control System for 18.5kW Centrifugal Fans in Food Processing Plant

Предыстория проекта

The sterilization workshop of a dairy plant needs to maintain a constant temperature of 120℃. Three 18.5kW centrifugal fans are deployed to automatically adjust operating quantity according to ambient temperature for energy saving.

Equipment Configuration

Main units: 3 sets of 18.5kW 400V three-phase centrifugal fans

Control components: 3 × S-T35 AC200V contactors + Temperature sensors + Мицубиси ПЛК + ЧМИ

Protection components: Moulded case circuit breaker + Thermal overload relay + Phase sequence protection relay

Solution Features

  1. Graded control: Automatically run 1/2/3 fans according to temperature ranges (≤115℃ / 115-125℃ / ≥125℃)
  2. Пуск звезда-треугольник: Reduces inrush current; the contactor withstands high starting impulse current effectively
  3. Visualization: HMI displays real-time operating status, current and temperature of each fan
  4. Maintenance reminder: Cumulative runtime recording reminds users of regular contactor maintenance

Application Results

Temperature control accuracy improved to ±1℃, product yield increased by 3%

22% энергосбережение, saving approximately 120,000 RMB on electricity annually

Extended fan service life and reduced replacement frequency

Simplified operation with less manual intervention

Случай 3: Conveyor Interlock Control System in Auto Parts Factory

Предыстория проекта

The assembly line of an automotive seat factory consists of 12 conveyors driven by 15kW motors. The system requires sequential start-up from feed end to discharge end, reverse sequence shutdown, and full-line shutdown protection once any conveyor fails.

Equipment Configuration

Main units: 12 sets of 15kW 400V three-phase conveyor motors

Control components: 12 × S-T35 AC200V contactors + Мицубиси ПЛК + 6 кнопки аварийной остановки + Safety relay

Signal system: 12 × GVAE11 auxiliary contact blocks (status feedback) + 24 индикаторные лампы (operation/fault)

Solution Features

  1. Interlock logic: PLC realizes interlock between conveyors via contactor auxiliary contacts to prevent material accumulation
  2. Безопасный дизайн: Emergency stop signal directly cuts off coil power of all contactors with response time ≤ 0.1 второй
  3. Fast fault diagnosis: Contactor status uploaded to PLC for quick fault location
  4. Модульная конструкция: Unified model reduces spare parts inventory and maintenance costs

Application Results

Production line failure rate reduced by 60%, production capacity increased by 15%

Average fault troubleshooting time shortened from 45 minutes to 5 минуты

Improved operational safety with zero safety incidents

30% lower spare parts cost and higher maintenance efficiency

Случай 4: Dual-motor Control System for Carding Machine in Textile Mill

Предыстория проекта

Renovation of BEFAMA CRIII carding machine in a wool textile mill. The original 37kW wound rotor motor with large starting current is replaced by a 7.5kW + 11kW dual-motor drive (total power 18.5kW), requiring synchronous start and balanced load.

Equipment Configuration

Main units: 7.5кВт + 11kW 400V three-phase dual motors

Control components: 2 × S-T35 AC200V contactors + Mitsubishi inverter + ПЛК + Current sensors

Protection components: 2 × thermal overload relays + Short-circuit protection circuit breaker

Solution Features

  1. Load balancing: PLC monitors motor current via sensors and dynamically adjusts inverter output
  2. Smooth start: Combined inverter and contactor reduces starting current from 68A to 28A and minimizes grid fluctuation
  3. Energy-saving operation: Motor speed automatically adjusted according to load, 30% energy saved
  4. Fault protection: Both contactors trip simultaneously if either motor is overloaded to avoid equipment damage

Application Results

Starting current reduced by 59%, eliminating grid fluctuation

30% энергосбережение, saving approximately 80,000 RMB on electricity annually

Extended equipment service life, maintenance cycle prolonged to 1 год

Improved product quality and wool sliver uniformity by 2%

  1. Application Classification & Рекомендации по выбору

3.1 In-depth Analysis of Applicable Scenarios

Тип приложенияSpecific UsageПреимущества выбораПримечания
Direct-on-line StartingМаленький & medium pumps, фанаты, компрессоры (≤18.5kW)40Номинальный ток, perfect match for 18.5kW motors, long mechanical lifeMust use with thermal overload relays; avoid over 1200 start-stop cycles per hour
Star-delta StartingReduced-voltage start for 15-30kW motors2NO+2NC contacts meet control demands for main/star/delta contactorsSelect S-T35 for main contactor, S-T20 for star/delta contactors
Duty/Standby OperationFire pumps, drainage pumps and critical equipmentНизкое энергопотребление, suitable for long-term standbyAdd automatic switching circuit to ensure standby availability
Interlock ControlProduction lines, conveyors and multi-motor systemsAbundant auxiliary contacts for complex logicMatch contactor mechanical life with system operating frequency
PLC ControlAutomated production lines and intelligent systemsAuxiliary contacts work reliably under micro-load (20В, 3мА) matching PLC outputsInstall surge suppressor in control circuit to protect PLC output points

3.2 Нерекомендуемые сценарии & Альтернативы

Unsuitable ScenarioReasonsАльтернативные решения
Single-phase motor control3-pole structure not applicable for single-phase circuitsSelect 2-pole contactors (single-phase version of S-T35)
Над 1200 start-stop cycles per hourShortens electrical life (rated 1 million AC-3 cycles)DC contactors or solid state relays
Altitude above 2000mReduced arc extinguishing capacity due to thin airDerate by 10% per 1000m elevation, or select high-altitude dedicated models
Severe vibration (over 5g)Risk of loose parts and false operationInstall shock-absorbing pads or vibration-resistant contactors
Corrosive & humid environmentsIP20 protection fails to prevent contact oxidationAdd protective enclosure or select IP65 products
Direct starting for motors over 50kWExcessive starting current damages contactsSoft starters or inverters
  1. Краткое содержание & Рекомендации по выбору

4.1 Application Value Summary

Высокая надежность: 10 million mechanical cycles and 1 million electrical cycles (AC-3 40A/400V) for long-term industrial operation

Cost Efficiency: Низкое энергопотребление (18VA pull-in, 3.8W holding) cuts operational cost and heat generation inside cabinets

Гибкость: 2NO+2NC auxiliary contacts support status monitoring, alarm and interlock functions

Good Compatibility: Matches GV2/GV3 motor circuit breakers and TH-T thermal overload relays to form a complete protection system

4.2 Мнемоника выбора

Ideal match for 18.5kW motors, S-T35 is your first choice

AC200V coil fits well, low power saves energy all the way

2NO plus 2NC contacts complete, for monitoring and alarm needs

IP20 solid protection, stable performance in industrial sites

4.3 Application Optimization Suggestions

  1. Protection Matching: Equip with thermal overload relays (например. TH-T35) and motor circuit breakers for dual protection against overload and short circuit.
  2. Installation Standard: Монтировать вертикально (±15°); reserve sufficient heat dissipation space (10mm left/right, 20mm top/bottom).
  3. Спецификация проводки: 1.5-35mm² copper wire for main circuit (torque 6-8Nm); 0.5-1.5mm² copper wire for control circuit (torque 0.8-1.2Nm).
  4. Цикл технического обслуживания: Inspect contacts every 6 месяцы; replace frequently operated contactors annually.
  5. High-temperature Adaptation: Снизить мощность 1% per ℃ when ambient temperature exceeds 40℃.