Это Шнайдер TeSys K series 3-pole miniature AC contactor. It has a rated operational current of 12A (АС-3, 440В), coil voltage of 110V AC, and is fitted with 1 Нормально открытый (1НЕТ) вспомогательный контакт. It adopts screw-clamp terminals. Designed for motor control, HVAC systems and small industrial equipment. Some legacy variants are discontinued, while this exact model remains in production. For performance upgrade, you may switch to the TeSys D series.
- Пояснение кода модели
| Сегмент кода | Определение | Подробное описание |
| LC1 | Категория продукта | Prefix for Schneider AC contactors; LC stands for contactor, 1 for standard type |
| К | Серия продуктов | TeSys K series, miniature compact contactors for low-power control |
| 12 | Номинальный рабочий ток | 12А (АС-3, 440В), suitable for motors up to 5.5kW @ 400V |
| 10 | Конфигурация вспомогательного контакта | 1НЕТ (1 Нормально открытый), 0Северная Каролина (0 Нормально закрытый) |
| Ф | Код напряжения катушки | 110Катушка переменного тока В (50/60Гц универсальный) |
| 7 | Wiring Type | Screw-clamp terminals, standard mounting |
- Основные технические характеристики
| Категория | Технические данные | Примечания |
| Основные характеристики | ||
| Тип продукта | 3-pole AC Contactor | For switching 3-phase circuits |
| Ряд | TeSys K | Schneider miniature contactor range |
| поляки | 3П (Л1, Л2, Л3) | 3-phase control |
| Номинальный рабочий ток (В) | 12А (АС-3, 440В) | Controls motors up to 5.5kW @ 400V |
| Номинальное рабочее напряжение (Уэ) | 690В и | Максимальное рабочее напряжение |
| Напряжение управляющей катушки (УК) | 110В и (50/60Гц) | Universal frequency design |
| Вспомогательный контакт | 1НЕТ (Нормально открытый) | For circuit latching or signal feedback |
| Параметры производительности | ||
| Rated Operating Frequency | 1200 cycles/hour (АС-3) | Standard duty for motor control |
| Механическая выносливость | 10,000,000 операции | No-load cycles |
| Электрическая выносливость | 1,000,000 операции (АС-3, номинальный ток) | On-load cycles |
| Потребляемая мощность катушки | Подобрать: 7Вирджиния, Холдинг: 2Вирджиния | Низкое энергопотребление, энергосберегающий |
| Pick-up Time | ≤ 60ms | Быстрый ответ |
| Drop-out Time | ≤ 40ms | Fast disconnection |
| Физические характеристики | ||
| Размеры (Ш × В × Г) | 45mm × 85mm × 57mm | Стандартная модульная конструкция, occupies 3 module units |
| Монтаж | 35мм DIN-рейка / Panel mounting | Compliant with EN 50022 |
| Терминалы | Винтовой зажим, max wire cross-section: 2.5мм² | Easy installation with reliable connection |
| Масса | Приблизительно. 180г | Weight per unit |
| Среда & Сертификаты | ||
| Рабочая температура | -25°C ~ +55°C | Performance may degrade beyond this range |
| Температура хранения | -40°С ~ +85°С | |
| Влажность | 5% ~ 95% (без конденсации) | |
| Защита от проникновения | IP20 | Finger-proof, not for outdoor use |
| Сертификаты | МЭК 60947-4-1, В 60947-4-1 | CE marked, complies with international safety standards |
| Lifecycle Status | ||
| Статус | Some old models updated; LC1K1210F7 is still in production | Obsolete legacy versions phased out; this model remains available |
- Полный список моделей (TeSys K Series 12A)
| Модель | Напряжение катушки | Вспомогательный контакт | Wiring Type | Order Reference | Приложение |
| LC1K1210F7 | 110В и | 1НЕТ | Винт | LC1K1210F7 | Общий производственный контроль, North American & Asian equipment |
| LC1K1210E7 | 48В и | 1НЕТ | Винт | LC1K1210E7 | Цепи управления безопасностью, low-voltage systems |
| LC1K1210G7 | 120В и | 1НЕТ | Винт | LC1K1210G7 | North American standard equipment |
| LC1K1210M7 | 220В и | 1НЕТ | Винт | LC1K1210M7 | Европейский & Asian standard equipment |
| LC1K1210Q7 | 24В Вашингтоне | 1НЕТ | Винт | LC1K1210Q7 | Цепи управления постоянным током, PLC systems |
| LC1K1201F7 | 110В и | 1Северная Каролина | Винт | LC1K1201F7 | Circuits requiring Normally Closed feedback |
| LC1K1210U7 | 240В и | 1НЕТ | Винт | LC1K1210U7 | Heavy-duty industrial equipment |
| LC1K1210V7 | 400В и | 1НЕТ | Винт | LC1K1210V7 | High-voltage control circuits |
- Замена & Cross-Brand Equivalents
4.1 Original Manufacturer Replacements
| Оригинальная модель | Запасная модель | Причина | Совместимость |
| LC1K1210F7 | LC1K1210F7 | Same model continuously produced | Fully compatible, прямая замена |
| LC1D1210F7 | Upgrade to TeSys D series with enhanced performance | Dimensionally compatible, improved functions | |
| LC1E1210F7 | Economy version for cost optimization | Similar performance, более низкая стоимость |
4.2 Cross-Brand Compatible Products
| Бренд | Модель | Соответствующий уровень | Примечания |
| АББ | A12-30-10*110V | 95% | Same dimensions and performance |
| Сименс | 3RT2015-1BB41 | 90% | Identical auxiliary contact configuration |
| Legrand | 8860 | 90% | Different terminal design |
| Чинт (Китай) | CJX2-1210*110V | 85% | Cost-effective with complete certifications |
- Приложение & Typical Cases
5.1 Recommended Applications
Управление двигателем: Direct start/stop for 3-phase asynchronous motors below 5.5kW
Системы отопления, вентиляции и кондиционирования: Control of air conditioning compressors, fans and water pumps, small central air-conditioning units
Промышленная автоматизация: PLC control circuits, конвейеры, packaging machinery and other small equipment
Коммерческие здания: Elevator door operators, fire safety equipment and lighting control
Agricultural Equipment: Irrigation pumps and greenhouse ventilation systems
5.2 Non-Recommended Applications
High-frequency cycling: Operating frequency over 1200 cycles/hour. TeSys D series is recommended.
High-power motors: Motors exceeding 5.5kW @ 400V. Select higher-rated contactors.
Outdoor humid environments: IP20 protection is insufficient; additional enclosure protection required.
Explosive hazardous areas: Explosion-proof contactors must be used.
5.3 Типичные случаи применения
Случай 1: Small Injection Molding Machine
Equipment: 3kW hydraulic pump motor for injection molding machine
Проблема: Original contactor was bulky and limited cabinet space
Решение: Install LC1K1210F7 together with overload relay
Результат: 50% space saving, simpler control circuit and lower failure rate
Случай 2: Hospital Central Air-Conditioning System
Equipment: 4kW fan motors in parallel operation
Requirements: Low noise, low power consumption and high reliability
Решение: Adopt LC1K1210F7 with Schneider EOCR overload protection
Результат: 15% энергосбережение, stable operation and reduced maintenance cost
- Поиск неисправностей & Руководство по техническому обслуживанию
6.1 Распространенные неисправности & Решения
| Явление неисправности | Возможные причины | Remedial Actions |
| Coil fails to pull in | 1. No voltage or incorrect coil voltage | 1. Verify power voltage matches coil rating |
| 2. Сгоревшая катушка | 2. Измерьте сопротивление катушки; replace if open-circuited | |
| 3. Open control circuit | 3. Check wiring and components in control circuit | |
| 4. Механические помехи | 4. Clean iron core, inspect springs and sliding parts | |
| Сильный шум после втягивания | 1. Broken shading coil | 1. Replace core assembly |
| 2. Dust/rust on core surface | 2. Clean core contact surface | |
| 3. Uneven mounting | 3. Reinstall and level the unit | |
| 4. Undervoltage supply | 4. Ensure supply voltage within 卤10% tolerance | |
| Main contacts burned | 1. Overload current | 1. Replace with higher-rated contactor |
| 2. Frequent cycling | 2. Optimize control logic to reduce switching frequency | |
| 3. Poor arc suppression | 3. Install surge suppressor | |
| 4. Fatigued contact springs | 4. Заменить контактный узел | |
| Auxiliary contact malfunction | 1. Burned contacts | 1. Replace auxiliary contact module |
| 2. Ослабленная проводка | 2. Retighten terminal screws | |
| 3. Linkage mechanism fault | 3. Inspect linkage; replace if necessary |
6.2 Maintenance Procedures
- Monthly Routine Inspection
Check appearance for damage or discoloration
Inspect terminals for looseness and overheating signs
Test pull-in and drop-out action for smooth operation and abnormal noise
- Annual Preventive Maintenance
Power off and clean surface with dry soft cloth
Inspect contact wear; replace if wear depth exceeds 1mm
Measure coil resistance to confirm normal status
Lubricate moving parts with small amount of silicone-based grease
- Replacement Cycle
Standard operating conditions: 5 ~ 8 годы
High-frequency cycling: 2 ~ 3 годы
Harsh environment (высокая температура / высокая влажность): 1 ~ 2 годы
6.3 Quick Troubleshooting Tips
For LC1K miniature contactors rated 12A for motor control
Check voltage first if coil fails to energize; check core for abnormal noise
Replace unit when contacts burn or auxiliary contacts fail
Regular inspection ensures safety; replace after 5 years service life
- Рекомендации по выбору
- Текущий рейтинг: Select current ≥ 1.2 раз номинальный ток двигателя. 12A is suitable for motors below 5.5kW.
- Напряжение катушки: Match coil voltage with control circuit voltage. Common ratings: 24В Вашингтоне, 110В и, 220В и.
- Вспомогательные контакты: 1NO for latching; 1NC for interlock; 1NO+1NC for complex control.
- Wiring Type: Screw terminals for fixed installation; spring terminals for frequent rewiring.
- Replacement Rule: Prioritize same-series products; verify dimensions and mounting when switching to other series.