Schneider LC1D115M7C Contactor - Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи

Вичат: +86-13184948252 WhatsApp: 0086-13811255435 Электронная почта: kent@bestcontactor.com

О Контакт |

Schneider LC1D115M7C Contactor - Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи

контактор/

Schneider LC1D115M7C Contactor

3-pole AC contactor, rated current 115A (АС-3), 220VAC coil, 1NO+1NC auxiliary contacts, screw terminals Order Number: LC1D11500M7C (full model), LC1D115M7C (abbreviated model) Domestic TeSys D series, phased out (launched in July 2025). Recommended replacements: LC1D115KUEC or LC1E120M5N Complete certifications: UL, CSA, МЭК, CCC, ЕАС, и т. д.. Compliant with RoHS/REACh standards Model Code Explanation Segment Code Description ...

  • Подробная информация о продукте

3-pole AC contactor, rated current 115A (АС-3), 220VAC coil, 1NO+1NC auxiliary contacts, винтовые клеммы

Номер заказа: LC1D11500M7C (full model), LC1D115M7C (abbreviated model)

Domestic TeSys D series, phased out (launched in July 2025). Recommended replacements: LC1D115KUEC or LC1E120M5N

Complete certifications: UL, CSA, МЭК, CCC, ЕАС, и т. д.. Compliant with RoHS/REACh standards

  1. Пояснение кода модели
СегментКодОписание
Категория продуктаLC1Contactor series
Construction TypeДTeSys D Series (Domestic high-current type)
Номинальный ток115Rated operational current 115A (АС-3, ≤440 В)
Вспомогательные контакты0Стандартная конфигурация: 1НЕТ + 1Вспомогательные контакты НЗ
Coil RatingМ220VAC coil voltage
Frequency Code7Universal coil for 50/60Hz
Manufacturing CodeСManufactured by SSIC (диапазон: 9~620A)

Полная модель: LC1D11500M7C (official standard model), Abbreviated Model: LC1D115M7C

  1. Основные характеристики
КатегорияПодробности
Основные параметры3-столб (3П), 3НЕТ главных контактов, 1NO+1NC auxiliary contacts, screw terminal connection
Номинальный токАС-1: 200А (≤440 В, ≤60°C); АС-3: 115А (≤440 В, ≤60°C)
Номинальное напряжениеГлавная цепь: ≤1000VAC; Схема управления: 220ВАК, 50/60Гц
Motor Control Rating30кВт (220~230V), 55кВт (380~400V), 75кВт (500В)
Механическая жизнь10 миллион операций (АС-3), 10 миллион операций (АС-1)
Электрическая жизнь1 million operations at rated current (АС-3), 1 million operations at rated current (АС-1)
Характеристики катушкиPick-up power: 1200Вирджиния; Holding power: 120Вирджиния; Impedance: 0.6МОм
Монтаж35mm DIN rail mounting or direct panel mounting
Размеры & МассаВысота: 158мм; Ширина: 120мм; Глубина: 136мм; Масса: приблизительно. 2.5кг
Класс защитыIP20 (per IEC 60529)
СертификатыUL, CSA, МЭК, CCC, ЕАС, Морской, RINA, ДНВ, и т. д..
  1. Полный список моделей (LC1D Series 115A)
МодельНапряжение катушкиТип терминалаПримечания
LC1D11500M7C220ВАКВинтСтандартный тип (original model)
LC1D11500P7C380ВАКВинтCommon alternative voltage
LC1D11500F7C110ВАКВинтLow voltage control
LC1D11500B7C24ВАКВинтSafety extra-low voltage control
LC1D115006M7C220ВАКRing terminalFor special wiring requirements
LC1D115KUEC100~250VAC/DCВинтUniversal voltage, replacement model
LC1D115ABD24В постоянного токаВинтDC coil version
LC1D115ALBD24В постоянного токаВинтLow-power DC coil

 

  1. Cross & Replacement Model List

4.1 Schneider Original Replacements

Оригинальная модельЗапасная модельПричина заменыСовместимость
LC1D115M7CLC1D115KUECUniversal voltage coil (100~250VAC/DC), higher flexibilityFully compatible, identical mounting dimensions
LC1D115M7CLC1E120M5NUpgraded TeSys E Series with improved performanceIdentical mounting dimensions; verify auxiliary contact configuration
LC1D115M7CLC1D11500M7CFull official model, identical to abbreviated version100% совместимый

4.2 Межбрендовые замены

БрендЗапасная модельОсновные различияApplicability
АББA145-30-11Rated current 145A with larger marginDifferent mounting dimensions; layout adjustment required
Сименс3RT2036-1BB40125А, АС-3, 220V coilSame auxiliary contact layout, прямая замена
Переключатель ЧаншуCJX2-1210Отечественная альтернатива, экономически эффективныйSlightly lower performance, for general working conditions
ЧинтNC1-1210Отечественная альтернатива, высокая стоимость исполненияMeets basic requirements, shorter service life
  1. Приложение & Отраслевые случаи

5.1 Применимые сценарии

Управление двигателем: Начинать, stop and reverse control for 30~75kW three-phase squirrel-cage motors

Промышленная автоматизация: Control circuits for production lines, конвейеры, compressors and pumps

Распределение мощности: Switching control for non-inductive or weakly inductive loads such as resistance furnaces and heaters (АС-1)

Системы отопления, вентиляции и кондиционирования: Control of large air conditioning compressors and ventilation fans

Морской & Offshore Engineering: Certified by marine classification societies for offshore equipment

5.2 Нерекомендуемые сценарии

High-Frequency Operation: Больше, чем 120 starts/stops per minute (use LC1D170 series or dedicated contactors)

Суровые условия: Heavy dust, corrosive gas or severe vibration (additional protection required)

DC Loads: Use dedicated DC contactors (например. LC1D115ABD)

High Altitude: Derating required above 2000m (10% derating per additional 1000m)

5.3 Типичные случаи применения

Случай 1: Fan Control in Steel Plant

Operating conditions: 380В, 55kW fan, АС-3, 10 starts per day, 20-hour continuous operation

Решение: LC1D115M7C + LRD3365 thermal overload relay

Преимущества: 3 years of stable operation without failure, low maintenance cost

Случай 2: HVAC System in Pharmaceutical Factory

Operating conditions: 400В, 45kW compressor, АС-3, 24-hour continuous operation and frequent cycling

Решение: LC1D115M7C + PLC control + surge suppressor

Преимущества: Low noise and power consumption, compliant with GMP standards

  1. Поиск неисправностей & Maintenance Manual

6.1 Common Fault Diagnosis

Явление неисправностиВозможные причиныРешения
Contactor fails to close1. No voltage on coil; 2. Burnt coil; 3. Mechanical jam1. Measure voltage across terminal A1/A2; 2. Check coil resistance (normal: приблизительно. 320Ой); 3. Power off, inspect mechanism and remove foreign objects
Loud noise after closing1. Пониженное напряжение; 2. Oil contamination on core contact surface; 3. Сломанное затеняющее кольцо1. Ensure voltage within ±10% of rated value; 2. Clean core surface; 3. Replace coil assembly
Overheated / burnt main contacts1. Overload current; 2. Плохой контакт; 3. Failed arc suppression1. Check for load overload; 2. Очистите или замените контакты; 3. Inspect arc chute integrity
Auxiliary contact malfunction1. Контактное окисление; 2. Ослабленная проводка; 3. Mechanical wear1. Очистите контакты; 2. Retighten terminals; 3. Replace auxiliary contact block
Repeated coil burnout1. Severe voltage fluctuation; 2. Frequent cycling; 3. Excess ambient temperature1. Install voltage stabilizer; 2. Replace with high-cycle model; 3. Improve heat dissipation

6.2 График технического обслуживания & Procedures

Предмет обслуживанияИнтервалОперация
Визуальный осмотрЕжемесячноCheck for overheating marks, abnormal odors and loose parts
Contact InspectionЕжеквартальныйИзмерьте контактное сопротивление (<50m惟), check for ablation
Coil InspectionРаз в полгодаMeasure coil resistance and insulation performance
Mechanical LubricationЕжегодноLightly lubricate moving parts (silicone grease recommended)
OverhaulКаждый 2 годыDisassemble for full inspection, replace worn parts and clean interior
  1. Phase-Out & Migration Guide

7.1 Phase-Out Information

Phase-out Plan: Schneider launched the phase-out of domestic high-current TeSys D series (115-170А) in July 2025

Transition Period: July 2025 – December 2026. Production will cease after the period

Inventory: Stock is still available via some distributors. Procurement or model replacement is recommended as soon as possible.

7.2 Migration Solutions

Migration TypeРекомендуемая модельПреимуществаПримечания
In-Series UpgradeLC1D115KUECUniversal voltage coil for wider applicationIdentical mounting size, no cabinet modification needed
Cross-Series UpgradeLC1E120M5NTeSys E Series with enhanced performance and longer service lifeAuxiliary contact layout may differ; verify control circuit
Cost-Saving ReplacementChangshu CJX2-1210 / Chint NC1-121030-50% снижение затратSlight performance difference; for non-critical applications

7.3 Migration Steps

  1. Confirm voltage and current requirements of the original control circuit
  2. Select suitable replacement model (LC1D115KUEC recommended)
  3. Verify compatibility of mounting dimensions and fixtures
  4. Confirm quantity and type of auxiliary contacts
  5. Replace contactor and conduct commissioning test
  6. Keep spare parts of the original model until the end of transition period
  7. Рекомендации по выбору

Краткий справочник правил

  1. LC1D: Schneider TeSys D series contactor
  2. 115: 115Номинальный ток (АС-3), matches 55kW motor at 400V
  3. M7C: 220VAC 50/60Hz coil, manufactured by SSIC
  4. 00: Standard 1NO+1NC auxiliary contacts
  5. Phase-out Notice: Prioritize LC1D115KUEC for replacement since July 2025
  6. Соблюдение требований в области авиаперевозок & Сертификаты

Классификация транспорта: Неопасные грузы. Нет встроенной литиевой батареи / supercapacitor, compliant with IATA regulations

Сертификация CE: Compliant with EN 60947-4-1, CE marked

Environmental Certification: Compliant with RoHS/REACh directives, Green Premium product

Упаковка: Individual packaging to prevent damage during transit. Original packaging is recommended.

Предыдущий:

Следующий:

Оставить ответ

Оставить сообщение