Schneider EGR-20UFCM Protection Relay

Schneider EGR-20UFCM Digital Earth Leakage Fault Protection Relay (Exclusive for EOCR) Schneider EGR-20UFCM is a dual-signal embedded relay designed for earth leakage fault protection. It features a wide measuring range of 0.03~20A, built-in filter and Modbus communication. Widely applied in low-voltage power distribution and motor protection. Match current range, detection type and mounting mode during ...

  • Подробная информация о продукте

Schneider EGR-20UFCM Digital Earth Leakage Fault Protection Relay (Exclusive for EOCR)

Schneider EGR-20UFCM is a dual-signal embedded relay designed for earth leakage fault protection. It features a wide measuring range of 0.03~20A, built-in filter and Modbus communication. Widely applied in low-voltage power distribution and motor protection. Match current range, detection type and mounting mode during selection. Strictly follow ZCT polarity and earthing specifications for reliable system operation.

  1. Model Code Definition
Сегмент кодаЗначениеОписание
EGRСерия продуктовDigital earth leakage & fault protection relay, Schneider EOCR series, manufactured by SAMWHA Korea
20Текущий диапазонMax detection current 20A, coverage 0.03~20A
UFDetection TypeDual-signal mode: U=Voltage(mV), F=Current(мА), compatible with ZCT zero-sequence current transformer
СМТип монтажаConsole panel mounting, equipped with digital display and protective cover

Quick Recognition: EGR-20UFCM = 20A range dual-signal embedded earth leakage protection relay, exclusive for EOCR

  1. Основные технические параметры
ПараметрСпецификацияRemark
Detection TypeТекущий(мА) + Напряжение(mV)Dual input, compatible with ZCT
Measuring Current Range0.03~20АWide coverage for diverse applications
Instant Fault Protection30мА, 30РСFast response for personal safety
Operating CharacteristicInverse / Definite time optionalFlexible for various protection demands
Источник питанияAC/DC 24V or 100~240VШирокое напряжение, global power grid adaptation
ОтображатьLED digital displayReal-time leakage current indication
Fault Record5 historical faults + RTC clockConvenient fault analysis and tracing
КоммуникацияМодбус РТУ (RS-485)Удаленный мониторинг и сбор данных
Вспомогательный контактSPDT (1C/O)Rated load AC 250V/3A resistive
защита от помехBuilt-in noise filterSuitable for high harmonic environment like inverter & UPS
Класс защитыIP52Dustproof and splash-proof
МонтажPanel embeddedСовместим со стандартной DIN-рейкой 35 мм.
ИзмерениеW45×H90×D110mmКомпактный размер, компактный
Рабочая температура-20~60℃Stable operation under harsh industrial conditions
Температура хранения-30~80℃Adapt to extreme storage environment
СертификацияCE, UL508, EN61010Comply with international safety standards
Номер заказаEGR-20UFCMOfficial unique part number
  1. Full EGR Series Models
МодельDetection TypeТекущий диапазонМонтажКлючевые особенности
EGR-20UFCMDual current & Напряжение0.03~20АPanel embeddedDigital display, harmonic resistance
EGR-20USAMCurrent signal0.03~20АБазовый монтажStandard base, easy wiring
EGR-10USVMVoltage signal0.03~10АБазовый монтажВходное напряжение, fit dedicated ZCT
EGR-20RY7MCurrent signal0.05~20АPanel embeddedСвязь RS-485, wide range
EGR-05UFCMDual current & Напряжение0.03~5АPanel embeddedSmall range, высокая точность
  1. Cross-brand Replacement Comparison
БрендМодельDetection TypeТекущий диапазонКоммуникацияСовместимость
Шнайдер

(SAMWHA)

EGR-20UFCMDual signal0.03~20АМодбус РТУPerfect match with EOCR and ZCT
Сименс3UG4615-1CR20Текущий0.03~30AМодбус РТУGeneral type, adaptation test required
АББCM-IW20Текущий0.05~20АNo communicationHigh load capacity, compatible with standard ZCT
ЧинтND-63Текущий0.03~30AOptional RS-485Cost-effective alternative
ВкусныйDZL-20Текущий0.05~20АNo communicationВнутренняя замена, slight dimension difference

Примечания по замене

  1. Confirm ZCT compatibility for third-party products to guarantee detection accuracy
  2. Dual U+F signal is exclusive to EGR-20UFCM, evaluate working condition before replacement
  3. Select filtered model for high harmonic occasions to avoid false tripping
  4. Поиск неисправностей & Обслуживание
Явление неисправностиВозможные причиныInspection StepsРешения
Frequent false trippingHarmonic interference, excessive earthing resistance, низкое значение настройкиCheck interference sources; measure earthing resistance ≤4Ω; verify parameter settingActivate filter; optimize earthing system; adjust protection threshold
No display under normal statusPower failure, wrong wiring, display damageTest power voltage; inspect ZCT wiring; check LED statusRestore power circuit; correct S1/S2 polarity; replace display module
No response upon faultExcessive setting value, defective auxiliary contact, damaged ZCTCheck action parameter; test contact continuity; measure ZCT secondary resistanceLower protection setting; replace contact parts; renew ZCT transformer
Communication failureMismatched parameters, wrong wiring, faulty moduleVerify baud rate, адрес и паритет; check A/B wire connection; test port voltageUnify communication parameters; correct wiring; replace communication module

Troubleshooting Rules

  1. Conduct leakage simulation test after installation to verify performance
  2. Enable filter function to reduce false action in high harmonic environment
  3. F01=Earth fault, F02=Overcurrent fault for quick positioning
  4. Приложение & Cases

Применимые сценарии

Распределение электроэнергии низкого напряжения: Earth fault protection for circuits below AC 600V

Центр управления двигателем: Combined leakage and overload protection with EOCR relay

Automatic production line: Inverter-driven motors and UPS power supply equipment

Химическая & petroleum industry: Safety protection for flammable and explosive sites, meet ATEX standard

Data center: Precision equipment protection to ensure power continuity

Building electrical system: Civil leakage protection complying with GB 13955

Неподходящие сценарии

High voltage system above 1kV without step-down transformer

Pure DC circuit with declined detection accuracy

Strong electromagnetic field without shielding measures

Operation without matched ZCT zero-sequence transformer

Typical Cases

Случай 1: Inverter Motor Protection in Automobile Workshop

10 sets of 75kW variable frequency motors equipped with ZCT-120. EGR-20UFCM adopts dual signal detection and filter design. It realizes 300mA/500ms leakage protection and fault record, improving system reliability by 50%.

Случай 2: Operating Room Power Renovation in Hospital

Meet IEC 61557-8 medical leakage protection standard. Combine EGR-20UFCM and ZCT-35 with 30mA instant protection setting, reaching Class B protection level and securing personnel safety.

  1. Выбор & Рекомендации по установке

Three-step Selection

  1. Confirm measuring range based on maximum system leakage current (0.03~20А)
  2. Choose dual UF signal for inverter occasions, single US signal for general use
  3. Select CM panel mounting for cabinet installation, SA base type for fast wiring

Меры предосторожности при установке

Thread three-phase four-wire cable through ZCT, neutral wire shall not be omitted

Connect ZCT S1 to EGR I+, S2 to I-, reversed connection causes detection failure

Single-point earthing for relay and ZCT, earthing resistance ≤4Ω

Turn on filter function under variable frequency working condition

Use shielded twisted pair for RS-485, avoid reversed A/B wiring

График технического обслуживания

ЭлементCycleСтандартный
Визуальный осмотрЕжемесячноNo crack, looseness or overheating
Functional testЕжеквартальныйNormal action via leakage simulation
Earthing resistance testSemi-annuallyResistance ≤4Ω
Тест связиSemi-annuallyStable data transmission without packet loss
Parameter verificationYearlySettings conform to site safety requirements

Application Scenarios of EGR-20UFCM

Applicable Fields

  1. Industrial Motor Protection

Suitable for variable frequency motors and heavy-duty three-phase motors. Cooperate with EOCR relay for comprehensive leakage and fault protection on production lines, фанаты, water pumps and air compressors.

  1. Low-voltage Distribution Circuit

Monitor earth fault of factory power cabinets, MCC control cabinets and branch circuits below AC 600V, prevent fire risks caused by leakage.

  1. Special Industry Power Consumption

Safety protection for flammable and explosive sites in chemical, oil and mining industry; electric control protection for port cranes and construction machinery.

  1. Medical Building Power Supply

Precise power distribution for operating rooms and diagnosis rooms, satisfy medical leakage safety standards.

  1. Data Center Room

Monitor feeder lines of UPS and server cabinets, avoid power outage induced by earth fault.

  1. ОВК & Water Treatment Equipment

Leakage protection for central air conditioning, circulating water pumps and sewage treatment control systems.

  1. Intelligent Monitoring Power Distribution

Connect to industrial control system via Modbus RTU, remotely check leakage data and trace fault history.

Inapplicable Fields

  1. Cannot be directly used on circuits over 1kV without step-down transformer
  2. Poor detection performance on pure DC power loop
  3. Prone to false tripping without shielding in strong electromagnetic environment
  4. Unable to work normally without matched ZCT zero-sequence transformer