TE Connectivity RAYCHEM POLT 3XIH1-L12A - Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи

Вичат: +86-13184948252 WhatsApp: 0086-13811255435 Электронная почта: kent@bestcontactor.com

О Контакт |

TE Connectivity RAYCHEM POLT 3XIH1-L12A

3XIH1-L12A is the specification code of TE Connectivity RAYCHEM brand POLT series ≤12kV 3-core heat-shrink power cable terminal. The complete model is usually marked as POLT-12D/3XIH1-L12A. It is suitable for outdoor terminal installation of polymer insulated power cables such as Cross-Linked Polyethylene (XLPE) and Polyethylene (ЧП), providing reliable electrical insulation and environmental protection.

TE Connectivity RAYCHEM POLT 3XIH1-L12A Heat-Shrink Power Cable Terminal

3XIH1-L12A is the specification code of TE Connectivity RAYCHEM brand POLT series ≤12kV 3-core heat-shrink power cable terminal. The complete model is usually marked as POLT-12D/3XIH1-L12A. It is suitable for outdoor terminal installation of polymer insulated power cables such as Cross-Linked Polyethylene (XLPE) and Polyethylene (ЧП), providing reliable electrical insulation and environmental protection.

  1. Определение сегмента модели
СегментЗначениеОписание
3Cable Core NumberSpecially for 3-core cables
ХInsulation TypeSuitable for polymer insulated cables (XLPE/PE/EPR)
IH1Тип щита & Size SpecificationIH = Copper Wire Shield; 1 = Conductor cross-section 70-120mm²
L12AКласс напряжения & Тип монтажаL12 = Rated voltage ≤12kV; A = Standard outdoor terminal
POLT-12DСерия продуктовPOLT = RAYCHEM heat-shrink power cable terminal series; 12D = 12kV outdoor type
  1. Основные параметры спецификации
Категория параметраТехнический индексПримечания
Основные характеристики
Тип продуктаHeat-shrink Power Cable TerminalOutdoor installation, polymer insulation system
БрендTE Connectivity RAYCHEMPOLT series, industry standard product
Применимый тип кабеля3-core polymer insulated power cableИзоляционный материал: XLPE, ЧП, ЭПР, и т. д..
Номинальное напряжение≤12kV (U0/U=8.7/15kV)Соответствует МЭК 60502-2
Cable Shield TypeCopper Wire ShieldNot applicable for copper tape shielded cables
Conductor Specification
Applicable Conductor Section70-120мм²Copper conductor
Conductor Outer Diameter14.0-22.0ммSingle core conductor diameter
Insulation Outer Diameter25.0-35.0ммSingle core insulation diameter
Overall Cable Outer Diameter55.0-75.0ммOuter diameter of complete 3-core cable
Физические характеристики
Total Terminal Length450ммStandard outdoor type length
Material CompositionCross-linked Polyolefin Heat-shrink MaterialWeather resistance, устойчивость к ультрафиолетовому излучению, aging resistance
ЦветЧерныйIndustrial standard color, anti-UV
Способ установкиHeat shrink installationSpecial heating tool required (≥300℃)
Условия окружающей среды
Рабочая температура-40°C ~ +90°CШирокий температурный диапазон, подходит для суровых условий
Защита от проникновенияIP68Полностью пыленепроницаемый и водонепроницаемый, operable under immersion
Weather ResistanceСоответствует МЭК 60811-3-1устойчивость к ультрафиолетовому излучению, ozone resistance, chemical corrosion resistance
Электрические характеристики
Сопротивление изоляции≥10¹⁴ΩNormal condition, ensure excellent insulation performance
Диэлектрическая прочность≥45kV/1minBreakdown strength of terminal insulation layer
Частичный разряд≤10pCUnder 1.73U0 voltage, maintain low partial discharge level
Creepage Distance630ммMeet pollution level requirements for 12kV class
  1. Список аксессуаров & Монтажные детали
Номер детали.ИмяФункцияQ’ty
3XIH1-L12A Main KitHeat-shrink Tube AssemblyProvide insulation, sealing and stress control1 Набор
Stress Control TubeNon-linear Heat-shrink TubeUniform electric field distribution, eliminate electric stress concentration3 шт. (1 per core)
Insulation TubeMain Insulation Heat-shrink TubeMain insulation protection1 ПК (для 3 cores)
Sealing TubeWaterproof Sealing Heat-shrink TubeSeal the joint between cable outer sheath and terminal1 ПК
ShedAnti-pollution Flashover Heat-shrink ShedIncrease creepage distance and anti-fouling performance3 шт.
Copper Mesh / Grounding WireShield Grounding WireGround connection for cable shielding layer1 Набор
Filling MasticInsulation Filling MaterialFill gaps between cores, improve insulation performance1 ПК
Cleaning Cloth / SandpaperSurface Treatment ToolsClean cable insulation surface, improve adhesion1 Набор
Руководство по установкеРуководство по эксплуатацииDetailed installation steps and precautions1 Copy
  1. Конкурент & Межбрендовый эквивалент
БрендЗапасная модельПохожие функцииРазличия
АББAPIT-12/3-70-12012kV 3-core, 70-120мм, copper wire shieldCold-shrink technology, не требуется подогрев, более высокая стоимость
5623P-1212kV 3-core, 70-120мм, copper wire shieldCold-shrink type, простая установка, permanent elasticity
ЧангюаньWS-12/3.212kV 3-core, 70-120мм, copper wire shieldHeat-shrink type, экономически эффективный, high domestic market share
WalsinWRS-12/3-70-12012kV 3-core, 70-120мм, copper wire shieldHeat-shrink type, material performance close to RAYCHEM
RAYCHEM Internal Replacement3XIH4-L12A12kV 3-core, 150-240мм, copper wire shieldFor larger conductor section, same terminal length
  1. Рекомендации по выбору & Решения по замене

5.1 Ключевые параметры выбора

ПараметрКлючевые моменты выбораРекомендуемый стандарт
Согласование напряженияMust match cable rated voltage12kV terminal for 8.7/15kV cable; not for higher voltage class
Основной номерTerminal core number shall be consistent with cable3-core terminal only for 3-core cable, not for single-core or 4-core
Conductor SectionTerminal range must cover cable conductor section70-120mm² terminal applicable to 70、95、120mm² cables
Тип щитаTerminal must match cable shield typeIH for copper wire shield; OH for copper tape shield
Среда установкиL type for outdoor; I type for indoorOutdoor site must adopt L type with sheds

5.2 Рекомендации по замене

Mismatched conductor section: Select corresponding range model, например. 150-240mm² use 3XIH4-L12A

Different shield type: Copper tape shield cable adopt 3XOH1-L12A

Внутренняя установка: Choose 3XIH1-I12A (without sheds)

Easier installation requirement: Adopt RAYCHEM cold-shrink terminal (RST series), no heating tool needed

5.3 Меры предосторожности при применении

  1. Check cable insulation condition before installation to ensure no damage and no moisture.
  2. Strictly follow installation manual; control heating temperature at 300-350℃ and heating time.
  3. Clean and polish core insulation surface tightly to ensure close fitting of heat-shrink tube.
  4. Reliably connect shielding grounding wire to guarantee electrical safety.
  5. Perform insulation test and partial discharge test after installation; put into operation only after qualified.
  6. Applicable for overhead, tunnel, cable trench and other outdoor / semi-outdoor occasions; not suitable for underwater use.
  7. Типичные сценарии применения

10kV/12kV distribution line outdoor cable terminals

12kV cable outgoing terminals of substation & switch station

12kV internal power distribution cable terminals for industrial enterprises

12kV cable terminals for new energy projects such as wind power & photovoltaic power generation

12kV cable terminal replacement & renovation of urban power grid

Предыдущий:

Следующий:

Оставить ответ