(Varispeed P7 Inverter Specialized for Fans & Насосы)
- Разбивка кода модели
CIMR-P7U4160 (Full name on nameplate: CIMR-P7U41600 PDF)
CIMR: Universal prefix for Яскава инверторы
P7: P7 series, energy-saving V/F inverter dedicated to fans and pumps
ты: 400V three-phase high-voltage model (380~480V)
4160: Power rating code, corresponding to 250HP / 160kW class
- Core Electrical Rated Specifications
2.1 Main Circuit Power Ratings
| Элемент | Ценить |
| Input Specification | 3-фаза переменного тока 380~480В, 50/60Гц |
| Rated Input Current | 334 А |
| Rated Output Capacity | 230 кВА |
| Номинальный выходной ток | 304 А (ND Normal Duty) |
| Matching Motor Power | 250HP / 160kW 3-phase induction motor |
| Max Output Voltage | 3-фаза 0 ~ input voltage (Макс. 480В) |
| Maximum Output Frequency | 120 Гц |
| Несущая частота | Adjustable from 2kHz to 10kHz |
| Accel/Decel Time Range | 0.0~6000s, two independent accel/decel groups |
2.2 Allowable Power Supply Fluctuation
Напряжение: +10% / -15%
Частота: ±5%
2.3 Контроль производительности
Speed Adjustment Range: 40:1 (V/F control)
Точность контроля скорости: ±2%~±3%
Режимы управления: Standard V/F, Energy-saving Square V/F (for fans & насосы), Multi-point V/F curve
- Механический & Экологические характеристики
- Рейтинг корпуса: NEMA1 wall-mounted closed cabinet
- Overall Weight: Приблизительно. 170кг
- Рабочая температура окружающей среды: 0℃ ~ +40 ℃ (требуется снижение номинальных характеристик при температуре выше 40 ℃)
- Влажность: ≤80%RH, нет конденсата
- Высота: No derating below 1000m; снижать номинальные характеристики 1% per additional 100m above 1000m
- Метод охлаждения: Built-in high-power cooling fan (individually replaceable)
- Braking Mode: Built-in DC dynamic braking; external braking unit/resistor required for high-power regenerative energy
- Hardware Interface Configuration
4.1 Main Circuit Terminals (R/S/T Input; U/V/W Motor Terminals; +/Тормозной блок; PE Earth)
Р, С, Т: 3-phase 380~480V power input
ты, В, Вт: Connection to 3-phase induction motor
+, -: External braking resistor / regenerative unit connection
ЧП: Protective earth (common ground for cabinet and main circuit)
4.2 Standard Control Circuit Configuration
Цифровые входы: 8 каналы, switchable between NPN and PNP
Digital Relay Outputs: 2 нормально открытые контакты (fault signal, run status signal)
Аналоговые входы: 2 каналы (0~10 В / 4~20mA frequency reference)
Аналоговые выходы: 2 каналы (monitor frequency, текущий, Напряжение)
Коммуникация: Стандартный Modbus-RTU; optional Profibus & DeviceNet communication cards
Digital Operator: 5-line 16-character LCD, supports parameter upload, download and copy
- Типичные сценарии применения
The P7 series is designed specifically for square-torque loads. The high-power CIMR-P7U4160 model applies to:
- Large cooling water circulation pumps, municipal water supply booster pumps
- Factory centrifugal fans, вытяжные вентиляторы котла, main dust removal fans
- Central air-conditioning chiller units, large cooling tower water pumps
- Горное дело & metallurgy dust exhaust fans, wastewater treatment aeration pumps
Преимущества: Built-in energy-saving square torque curve, sleep function, multi-pump rotation switching, constant pressure PID control
- Решение для замены, снятое с производства (P7 series fully discontinued)
Direct Drop-in Upgrade: Yaskawa P1000 Series
Equivalent replacement model: CIMR-PU4A0415ABA
- Fully matched power rating: 304Выход, compatible with 160kW motors
- Full function coverage: Retains all fan & pump dedicated functions of P7 (multi-pump control, ПИД, спящий режим)
- Highly compatible communication protocols, terminal logic and parameter sets, low renovation workload
- Merits: Higher energy efficiency, встроенный фильтр ЭМС, enhanced fault diagnosis, abundant spare parts
Alternative General Heavy-Duty Option: A1000 Series
(Vector type, selected for heavy-duty or closed-loop control demands)
- Распространенные коды неисправностей & Матрица устранения неполадок (Universal for P7 Series)
| Код неисправности | Описание неисправности | Первопричина | Remedial Actions |
| OC/OC1/OC2/OC3 | Overcurrent during Accel / Decel / Constant Speed | Короткое замыкание двигателя, cable earth fault, mechanical stall, overly short accel/decel time | Test motor insulation; extend accel/decel time; inspect mechanical jamming |
| подруга | Output Ground Fault | Damaged insulation on U/V/W cables, motor winding breakdown to earth | Disconnect motor cables section by section and test insulation separately |
| УФ | Пониженное напряжение шины постоянного тока | Mains phase loss, excessive voltage drop, poor contact of contactor | Measure three-phase voltage of R/S/T; fasten main circuit terminals |
| ОВ | Перенапряжение на шине постоянного тока | Excessively fast deceleration, no braking resistor, high mains voltage | Lengthen deceleration time; install external braking unit |
| OL1 | Motor Overload | Чрезмерная нагрузка, long-time low-speed operation, incorrect motor current parameter | Verify rated motor current parameter E2-01; уменьшить нагрузку |
| OL2 | Inverter Overload | Sustained 150% номинальный ток для 1 минута | Уменьшите нагрузку, upgrade inverter size, lower carrier frequency |
| СПИ | Потеря входной фазы | Broken wire on one R/S/T phase, перегоревший предохранитель | Inspect input circuit breaker, terminals and three-phase voltage balance |
| SPO | Output Phase Loss | Disconnection of one U/V/W phase, burnt single-phase motor contact | Tighten motor terminals; test cable continuity |
| OH1/OH2 | Overheat (Радиатор) | Dust-clogged air duct, damaged cooling fan, ambient temperature over 40℃ | Clean air filter; replace cooling fan; улучшить вентиляцию |
| LF | Output Three-Phase Imbalance | Damaged motor winding, loose wiring terminals | Measure three-phase output current; fasten all terminals |
- Strict Wiring & Installation Prohibitions
- Main power cables and control signal wires must be routed in separate cable trays with a minimum spacing of 30cm; long parallel laying is forbidden.
- Shielded motor cables are recommended; shield shall be grounded only at the control cabinet end.
- Main circuit copper busbars of high-power models shall be tinned and tightened with specified torque to avoid overheating and arcing.
- For multi-pump linked systems, AC contactors shall not be installed on the inverter output side for frequent switching.
- For sites with heavy dust and moisture, clean air duct filters regularly to prevent overheat alarms.
- If long motor cables (>50м) необходимы, an output du/dt filter must be installed to suppress peak voltage and protect motor insulation.
- Key Basic Commissioning Parameters (Standard for Fan & Pump Applications)
- E1-06 Base Frequency: Rated 50/60Hz as marked on motor nameplate
- E1-13 Square V/F (Fan Energy Saving): Установить на 2 to enable square torque curve
- b5 PID Pressure Closed-Loop: Set target pressure and P/I/D gains
- b5-17 Sleep Function: Low-frequency energy-saving sleep, auto-stop during idle periods
- C1-01~C1-04 Accel & Decel Time: ≥15s recommended for pumps, ≥30s for fans to avoid overcurrent
- E2-01 Motor Rated Current: Enter value per motor nameplate, baseline for overload protection
Complete Model List of Yaskawa Varispeed P7 Series (CIMR-P7U□4□□□) 400V Series
Примечания
- Series Naming Rule: `CIMR-P7U4XXX0`. The full code printed on the nameplate ends with digit 0, which is omitted as the short model number for selection (например, CIMR-P7U4160).
- U = Dedicated 3-phase 380~480V model for fans and pumps; ND Normal Duty (square-torque loads for fans & насосы).
- Power correspondence unit: кВт / HP / Номинальный выходной ток (А).
- The entire series adopts V/F control, built-in square torque curve and PID multi-pump control. This series has been fully discontinued, with replacement models CIMR-PU4A□□□□ (P1000 series).
- Низкий & Medium Power Range (7.5kW ~ 132kW)
| Full Model No. | Matching Motor Power | Номинальный выходной ток (А) |
| CIMR-P7U40070 | 7.5кВт / 10HP | 18 |
| CIMR-P7U40110 | 11кВт / 15HP | 24 |
| CIMR-P7U40150 | 15кВт / 20HP | 30 |
| CIMR-P7U40180 | 18.5кВт / 25HP | 37 |
| CIMR-P7U40220 | 22кВт / 30HP | 43 |
| CIMR-P7U40300 | 30кВт / 40HP | 57 |
| CIMR-P7U40370 | 37кВт / 50HP | 69 |
| CIMR-P7U40450 | 45кВт / 60HP | 83 |
| CIMR-P7U40550 | 55кВт / 75HP | 106 |
| CIMR-P7U40750 | 75кВт / 100HP | 130 |
| CIMR-P7U40900 | 90кВт / 125HP | 160 |
| CIMR-P7U41100 | 110кВт / 150HP | 192 |
| CIMR-P7U41320 | 132кВт / 175HP | 232 |
- High Power Range (160kW ~ 400kW, including CIMR-P7U4160 you inquired)
| Full Model No. | Matching Motor Power | Номинальный выходной ток (А) |
| CIMR-P7U41600 | 160кВт / 250HP | 304 |
| CIMR-P7U42000 | 200кВт / 300HP | 370 |
| CIMR-P7U42200 | 220кВт / 330HP | 415 |
| CIMR-P7U42500 | 250кВт / 375HP | 460 |
| CIMR-P7U43150 | 315кВт / 450HP | 580 |
| CIMR-P7U43750 | 375кВт / 500HP | 690 |
| CIMR-P7U44000 | 400кВт / 540HP | 730 |
Supplementary Key Remarks
- 200V single/3-phase P7 models (P7E / P72 series) are excluded from the above table. This list only covers mainstream industrial 400V 3-phase fan & pump models P7U.
- Model Abbreviation Rule: The trailing digit 0 is often omitted in engineering drawings and procurement documents. Например, CIMR-P7U41600 is abbreviated as CIMR-P7U4160.
- Cabinet Classification: Models ≤132kW adopt standard wall-mounted cabinets; models ≥160kW (4160 и выше) are large floor-standing cabinets equipped with independent high-power cooling fans.
- Distinction of output versions at the same power rating:
Standard built-in braking transistor; high-power models 4160 and above require an external braking unit + braking resistor to implement dynamic braking during deceleration.
- Discontinued Model Replacement Mapping (P7U4XXXX → P1000 PU4AXXXX)
CIMR-P7U41600 (160кВт) → CIMR-PU4A0415ABA
CIMR-P7U42000 (200кВт) → CIMR-PU4A0475ABA
CIMR-P7U42500 (250кВт) → CIMR-PU4A0605ABA
Контактор,автоматический выключатель,солнечный инвертор,электрический счетчик,солнечные батареи