Bently Nevada 3500/42M-A09-B00 Proximitor/Seismic Monitor (Dynamic Data Acquisition Module)
ยี่ห้อ: Bently Nevada (Baker Hughes), part of the 3500 Series TSI Machinery Protection System. Official Name: Proximitor/Seismic Monitor. Base Order Part Number: 143694-01. It is a 4-channel programmable card supporting both protection alarming and dynamic waveform acquisition, serving as the core monitoring card for steam turbine units.
- คำอธิบายรหัสรุ่น: 3500/42M-A09-B00
3500: 3500 TSI Machinery Protection System
/42ม: 4-channel Proximitor/Seismic Monitor card. คำต่อท้าย “ม” means dynamic waveform acquisition is supported. The legacy 3500/42 does not support dynamic data acquisition.
A09: Segment A = Sensor Input Option. 09 = Supports both Proximitor (Eddy Current) and Seismic sensors (velocity / การเร่งความเร็ว).
B00: Segment B = Certification Option. 00 = Without CSA NRTL/C certification; B01 is the version with CSA certification.
Distinction Notes
A01: Eddy current input only; A02: Seismic sensor input only; A09 hybrid type can connect to 3300XL eddy current probes for shaft vibration / axial displacement measurement, and also piezoelectric velocity sensors for bearing housing vibration measurement.
3500/40ม: Speed and keyphase only; 3500/45: Temperature card; 3500/42M is the primary monitoring card for vibration and displacement.
- ข้อมูลจำเพาะทางเทคนิคหลัก
| รายการ | ข้อมูลจำเพาะ |
| จำนวนช่อง | 4 ช่องทางอิสระ. Channels are configured in pairs (1&2 as one group, 3&4 as another group). Each group can be set for one measurement type. |
| Sensor Input (A09) | Eddy current Proximitor (3300XL series) + Seismic sensors (velocity / การเร่งความเร็ว) |
| Measurable Parameters | Radial shaft vibration, axial thrust displacement, differential expansion, eccentricity, REBAM, bearing housing velocity/acceleration, shaft absolute vibration, CAA (Circular Acceptance Area) |
| Signal Frequency Range | Eddy current: 10Hz~10kHz; Seismic:1Hz~10kHz |
| Static Measurement Accuracy | ±0.5%เอฟเอส; Dynamic waveform acquisition for System1 spectrum analysis |
| การกำหนดค่าสัญญาณเตือน | Alert warning available per channel; Each group supports 2 Danger trip setpoints to drive hardwired protection relays via 3500/33 card |
| อุณหภูมิในการทำงาน | -30℃ ~ +65 ℃ (inside cabinet) |
| การใช้พลังงาน | Max 10W, powered by rack backplane |
| Indicators | ตกลง, TX/RX backplane communication LEDs, independent status LED for each of 4 ช่อง |
| ซิล | The complete system meets SIL2 (subject to full loop assessment); Compliant with API670 machinery protection standard |
| การติดตั้ง | Full-height card, fits any monitoring slot in 3500 แร็ค; hot-swappable (interlock must be removed before operation) |
III. ฟังก์ชั่นหลัก
- Paired channel configuration: Channels 1&2 can be configured for shaft vibration while channels 3&4 for bearing housing vibration. The same card can mix eddy current and seismic sensors.
- Static protection measurement: Calculate vibration amplitude and displacement values in real time, compare with setpoints to trigger Alert / Danger alarms, and send signals to 3500/33 relay card for hardwired unit trip protection.
- Dynamic waveform acquisition (core feature of M version): Capture raw vibration waveforms, 1X/2X amplitude and phase, upload to System1 for spectrum and orbit analysis to diagnose faults such as rotor unbalance, misalignment and rub.
- Sensor self-diagnosis: Detect probe open circuit, short circuit and excessive gap deviation; sensor faults are directly logged into rack event history.
- REBAM® Bearing Condition Monitoring: Bently patented algorithm to evaluate bearing oil film stability.
- การบันทึกเหตุการณ์: Alarms and sensor faults are recorded with timestamps, which can be uploaded to DCS through 3500/92 communication gateway card.
- สถานการณ์การใช้งานทั่วไป
Steam turbines, centrifugal compressors, แฟนแกน, มอเตอร์ขนาดใหญ่; TSI systems in thermal power, coal chemical and oil & gas refining industries.
Eddy current channels: Rotor radial vibration, axial displacement, differential expansion
Seismic channels: Bearing housing casing vibration (velocity / การเร่งความเร็ว)
- การติดตั้ง & Configuration Guidelines
- สายไฟ: Eddy current probe extension cable + proximitor. Cable length must be matched (3300XL system uses fixed-length cables, must not be arbitrarily cut). Seismic sensor shielded cable with single-point grounding.
- Configuration Procedure
Connect rack via Rack Configuration software and add 3500/42M card.
Channel grouping: Set channel1/2 to eddy current radial vibration; channel3/4 to seismic velocity.
Set sensor sensitivity, measurement range, Alert warning value and Danger trip setpoint.
Enable dynamic acquisition and configure waveform sampling parameters.
Download configuration to rack; confirm channel OK LED steady on, perform probe gap verification and simulate alarms to test relay operation.
- การว่าจ้าง: Verify eddy current probe gap voltage (around -10V DC); calibrate seismic sensor sensitivity.
- Common Troubleshooting Checklist
- OK LED flashing: หายไป / invalid card configuration, re-download rack configuration.
- Channel reports sensor fault: Abnormal proximitor power supply, open/short circuit of cable, worn probe or out-of-range gap; check gap voltage output from proximitor.
- Fluctuating vibration readings: Multi-point grounding of proximitor shield, cable routed near power cables causing interference; loose probe mounting.
- Normal static value but no dynamic waveform in System1: Dynamic acquisition not enabled in configuration, or missing 3500/22M transient interface module.
- Danger alarm fails to trigger relay: Verify alarm voting logic and configuration mapping between 3500/33 relay card.
ปกเกล้าเจ้าอยู่หัว. การเปรียบเทียบซีรี่ส์ & การเลือกรุ่น
| แบบอย่าง | ประเภทอินพุต | Dynamic Acquisition | การรับรอง |
| 3500/42M-A09-B00 | Hybrid Eddy Current + Seismic | รองรับ | No CSA |
| 3500/42M-A09-B01 | Hybrid Eddy Current + Seismic | รองรับ | With CSA |
| 3500/42M-A01-B00 | Eddy Current Only | รองรับ | No CSA |
| 3500/42-A01-B00 | Eddy Current Only | No dynamic acquisition | No CSA (มรดก, ค่อย ๆ หมดไป) |
Metrix ST5484E-123-434-22 Seismic Velocity Vibration Transmitter
ยี่ห้อ: Metrix (สหรัฐอเมริกา). ST5484E is an integrated 2-wire loop-powered velocity vibration transmitter. It adopts built-in piezoelectric accelerometer core, integrating circuit and true RMS processing, directly outputs 4–20mA signal for bearing housing casing vibration monitoring. Different from Bently eddy current probes which measure shaft vibration.
- คำอธิบายรหัสรุ่น: ST5484E-123-434-22
Model format: ST5484E AAA BBCC EF
123: Range code, 2.0 in/s (50.8 mm/s RMS), 4mA=0; 20mA=full scale 50.8mm/s
434: กรอง, mounting thread, วัสดุที่อยู่อาศัย
4: Filter option
3: ด้ายยึด 1/4-28 UNF stud mounting
4: 316 ตัวเรือนสแตนเลส
22: การเชื่อมต่อไฟฟ้า + การรับรองการป้องกันการระเบิด
2: 2-terminal block wiring
2: Ex ia IIC T4 intrinsically safe version
Distinction Notes
ST5484E: Casing vibration velocity transmitter; ST5491E with local display; SW5484E with built-in relay vibration switch.
- ข้อมูลจำเพาะทางเทคนิคหลัก
| รายการ | ข้อมูลจำเพาะ |
| หลักการวัด | Piezoelectric acceleration + บูรณาการ, outputs vibration velocity RMS value |
| ช่วงการวัด | 0~2.0 in/s (0~50.8 mm/s RMS) |
| สัญญาณเอาท์พุต | 2-wire 4–20mA, loop powered; Metrix patented IPT non-polar wiring |
| แรงดันไฟฟ้า | 11~29.6 VDC (24แนะนำให้ใช้ VDC) |
| การตอบสนองความถี่ | 2Hz ~ 1kHz, suitable for casing vibration monitoring of pumps, แฟน ๆ, motors and compressors |
| วัสดุที่อยู่อาศัย | 316 สแตนเลส |
| การติดตั้ง | 1/4-28 UNF stud, directly fastened onto bearing housing surface |
| Explosion-proof Rating | ATEX/IECEx Ex ia IIC T4 Ga (ปลอดภัยอย่างแท้จริง, safety barrier required) |
| การป้องกันทางเข้า | IP67 |
| อุณหภูมิในการทำงาน | -40℃ ~ +85 ℃ |
| การแยกตัว | 500Vrms isolation between loop and housing |
| น้ำหนัก | ประมาณ. 170ก |
| ลักษณะเฉพาะ | Factory calibrated, no zero/range potentiometer for field adjustment; 4-wire version optional with raw acceleration dynamic output |
III. ฟังก์ชั่นหลัก
- Integrated RMS processing: Built-in integration and true RMS circuit, directly output 4-20mA proportional to vibration velocity. Can be connected to DCS/PLC directly without extra proximitor.
- IPT non-polar loop: Wiring without positive/negative polarity distinction to reduce field wiring errors.
- Intrinsically safe explosion protection: โซน 0 ปลอดภัยอย่างแท้จริง, applicable for hazardous areas in chemical and petrochemical industries.
- Optional narrowband filter to suppress high-frequency interference, fit for rolling bearing equipment monitoring.
- Single-direction measurement: Measures along sensor axial direction; align monitoring direction (แนวนอน / แนวตั้ง) during installation.
- สถานการณ์การใช้งานทั่วไป
Bearing housing casing vibration monitoring for centrifugal pumps, แฟน ๆ, มอเตอร์, gearboxes and small compressors; ปิโตรเคมี, coal chemical and power plants.
>Comparison with Bently 3500/42M: ST5484E outputs standard 4-20mA to DCS and cannot provide raw dynamic waveform for spectrum analysis. Bently 42M can capture raw waveforms for fault diagnosis.
- การติดตั้ง & Commissioning Guidelines
- การติดตั้ง: Stud must be tightened on flat metal surface of bearing housing, polish and remove rust on contact surface. Sensor axial direction must align with measured vibration direction. Avoid installation on thin wall or stiffener (resonance interference).
- สายไฟ: 2-wire intrinsically safe loop, intrinsically safe safety barrier is mandatory. Shielded cable single-point grounding; do not route together with power cables in the same cable tray.
- Loop calculation: Maximum allowable loop resistance depends on supply voltage. Max loop resistance ≈650Ω under 24VDC supply.
- การสอบเทียบ: Full-unit calibration on vibration shaker table. No zero or span adjustment knobs inside sensor; range cannot be modified on site.
- การกำหนดค่า: Set in DCS: 4mA=0 mm/s, 20mA=50.8 mm/s, configure high vibration alarm and high-high interlock setpoints.
- Common Troubleshooting Checklist
- Fixed 4mA output: Broken loop, faulty safety barrier, loss of sensor power supply; damaged internal sensing element.
- เอาต์พุตคงที่ 20mA: Short circuit in loop, damaged internal circuit of sensor, vibration exceeds full scale.
- Fluctuating readings: การติดตั้งแบบหลวม, resonance on contact surface; multi-point grounding of shield; cable interference from inverter power lines.
- Low vibration readings: Wrong installation direction; paint/gasket on contact surface leading to weakened vibration transmission.
ปกเกล้าเจ้าอยู่หัว. การเปรียบเทียบซีรี่ส์ & การเลือกรุ่น
| แบบอย่าง | พิสัย | สายไฟ | ป้องกันการระเบิด | Dynamic Output |
| ST5484E-123-434-22 | 50.8mm/s RMS | 2-core terminal | Intrinsically safe Ex ia | เลขที่ (4-20mA only) |
| ST5484E-124 | 125มิลลิเมตร/วินาที | Lead wire | ไม่จำเป็น | เลขที่ |
| ST5484E 4-wire version | On demand | 4-แกนกลาง | ไม่จำเป็น | With raw acceleration dynamic signal |
| ST5491E | Same as ST5484E | ไม่จำเป็น | ไม่จำเป็น | With local digital display |
คอนแทคเตอร์,เบรกเกอร์,เซ็นเซอร์,ตัวเข้ารหัส,บมจ,ตัวแปลง