Anderson-Negele FMQ050SDMXX Electromagnetic Flow Meter - Contactor,circuit breaker,solar inverter,electric meter,solar batteries

Wechat: +86-13184948252  WhatsaApp: 0086-13811255435  E-mail:  kent@bestcontactor.com

About    Contact    |    

 Anderson-Negele FMQ050SDMXX Electromagnetic Flow Meter - Contactor,circuit breaker,solar inverter,electric meter,solar batteries

NewsTrade News

 Anderson-Negele FMQ050SDMXX Electromagnetic Flow Meter

 Anderson-Negele FMQ050SDMXX Electromagnetic Flow Meter

  1. Model Code Definition
Code SegmentDescription
FMQBasic series code: Sanitary electromagnetic flow meter, applicable to food, pharmaceutical and biotechnology industries
50Pipe size: DN50 (2 inch), inner diameter of measuring tube 50mm
SSensor type: Standard sensor with PFA liner for general sanitary applications
DDisplay option: Backlit graphic display with touch button operation, no need to open the housing
MCommunication interface: Standard IO-Link communication, supports simultaneous digital and analog output
XXProcess connection: Customizable connection types (clamp, thread, flange, etc.)
  1. Core Technical Specifications
CategoryDetailed SpecificationsRemarks
Basic Parameters
Brand / OriginAnderson-Negele / GermanySpecialized in sanitary process instruments, founded in 1947
Product TypeElectromagnetic inductive flow meterNo moving parts, low-maintenance design
Measuring PrincipleFaraday’s law of electromagnetic inductionInduced electromotive force generated by conductive fluid cutting magnetic field lines
Nominal DiameterDN50 (2 inch)Corresponding model: FMQ050
Measuring Performance
Measuring RangeFlow velocity: 0.1~10 m/sSuitable for various flow working conditions
Flow rate: 30~280,000 L/h (DN50)
Measuring Accuracy±0.5% of reading ±2 mm/sMaintains high accuracy at low flow velocity
Repeatability±0.15% of readingIdeal for filling and batching processes
Fluid Conductivity≥5 μS/cmCompatible with most liquids, pastes and creams
Solid Content≤5% solid particlesAble to measure media containing a small amount of solid particles
Fluid Compatibility
Wetted Materials1.4404 (316L) / 1.4435 stainless steel, Ra≤0.4 μm (electropolished)Compliant with 3-A sanitary standard, excellent corrosion resistance
Measuring tube liner: PFA
Fluid Temperature-10°C ~ +130°CResists CIP/SIP cleaning at 130°C for 30 minutes
Working PressureSubject to process connections and seals
Standard clamp connection: 16 bar (232 psi)
Electrical Parameters
Power Supply24V DC ±10%, Max. 4WLow power consumption design
Output Signals4~20 mA (Load ≤500 Ω), pulse output (Max. 1kHz)Dual analog and digital outputs operate simultaneously
IO-Link V1.1 communication
Switch Input1 channel for flow/volume counter reset (optional)Improve process control flexibility
Mechanical & Environmental
Protection ClassTransmitter: IP67Resists high-pressure washing and harsh industrial environments
Sensor: IP69K
Housing Material316L stainless steelCorrosion-resistant, suitable for sanitary areas
Installation ModeOmni-directional installation, full-pipe operation recommendedBuilt-in empty pipe detection to avoid false readings
Ambient Temperature-20°C ~ +60°CWide temperature range for extreme working environments
  1. Common Faults & Maintenance Solutions

3.1 Fault Diagnosis Table

Fault PhenomenonPossible CausesTroubleshooting Steps
No flow display / no output1. Insufficient fluid conductivity1. Confirm fluid conductivity ≥5 μS/cm
2. Sensor not fully filled with liquid2. Ensure full pipe flow and eliminate air bubbles
3. Power supply failure3. Verify input voltage 24V DC±10%
4. Incorrect wiring4. Check wiring diagram and correct wiring errors
Unstable measured values1. Excessive air bubbles in fluid1. Optimize pipeline venting to remove bubbles
2. Flow velocity below 0.1 m/s2. Keep flow velocity within measuring range
3. Electrode contamination3. Clean electrode surface after power cut-off
4. Poor grounding4. Control grounding resistance ≤10 Ω
Large measuring error1. Incorrect sensor calibration1. Re-calibrate the sensor
2. Electrode scaling2. Chemically clean electrodes following CIP/SIP procedures
3. Massive air bubbles inside fluid3. Optimize pipeline layout to reduce bubbles
4. Improper installation position4. Install sensor on straight pipe section (10D upstream, 5D downstream)
Communication failure1. Damaged IO-Link cable1. Inspect cable connection and integrity
2. Mismatched communication parameters2. Confirm IO-Link baud rate and address
3. Internal module failure3. Replace communication module or contact supplier for repair

3.2 Maintenance Recommendations

  1. Daily Inspection

Check display status and reading stability weekly

Inspect terminal tightness and cable integrity monthly

Verify sensor installation tightness and pipeline sealing quarterly

  1. Periodic Maintenance

Perform CIP/SIP cleaning at 130°C for 30 minutes every 6 months to keep sensor clean

Inspect electrode condition annually; clean or replace electrodes if necessary

Complete sensor calibration every 2 years to guarantee measuring accuracy

Check liner integrity every 3 years to prevent liquid leakage

  1. Service Life Replacement Cycle

Normal working condition: PFA liner service life 5-8 years, electrode service life 3-5 years

Severe working condition (corrosive fluid / frequent CIP cleaning): shorten service life by 30%

  1. Full Series Model List

Basic FMQ Series Models (By Nominal Diameter)

ModelDN SizeFlow Range (L/h)Core FeaturesTypical Application
FMQ010DN10 (1/2″)30~16,000Mini size, high precisionMicro-flow batching, laboratory use
FMQ015DN15 (3/4″)30~36,000Compact structureSmall-batch food & beverage production
FMQ025DN25 (1″)30~100,000Standard universal typePharmaceutical batching system
FMQ040DN40 (1.5″)30~200,000High flow rate, high accuracyDairy production line
FMQ050DN50 (2″)30~280,000Mainstream size, standard IO-LinkBrewery industry, beverage filling
FMQ065DN65 (2.5″)30~450,000Large flow rate, high stabilityJuice production line
FMQ080DN80 (3″)30~580,000Extra large flow rate, pressure-resistantEdible oil production
FMQ100DN100 (4″)30~640,000Max pipe size, industrial gradeBulk liquid transportation

Complete Naming Rule

FMQ[Size][Sensor Type][Display Type][Communication][Process Connection]

Size: 010~100 corresponding to DN10~DN100

Sensor Type: S=Standard, H=High Temperature, E=Explosion-proof

Display Type: D=With display, N=No display

Communication: M=IO-Link, A=Analog output, P=Pulse output

Connection Type: T=Clamp, R=Thread, F=Flange

  1. Cross-brand Product Comparison
BrandModelDN SizeMeasuring AccuracyCore DifferencesApplication Scenarios
Anderson-NegeleFMQ050SDMXXDN50±0.5% ±2 mm/sStandard IO-Link, PFA liner, IP69K protectionSanitary food & pharmaceutical industry with frequent CIP cleaning
Endress+HauserPromag 50PDN50±0.3% ±1 mm/sHigher precision, multiple communication protocolsHigh-precision pharmaceutical and biotechnology industry
KROHNEOPTIFLUX 1050DN50±0.5% ±2 mm/sCost-effective, modular designMass production of food and beverage
ABBAquaMaster 3DN50±0.5% ±2 mm/sSelf-cleaning electrode, suitable for particle-containing mediaWastewater treatment, papermaking industry
E+HProline Promag HDN50±0.5% ±2 mm/sHigh temperature & pressure resistance up to 180°CHigh-temperature disinfection process, chemical industry

Selection Key Points

  1. Sanitary Grade: Anderson-Negele FMQ complies with 3-A standard with Ra≤0.4 μm electropolished surface
  2. Communication Performance: Built-in IO-Link facilitates Industry 4.0 system integration
  3. Maintenance Cost: No moving parts plus empty pipe detection reduce maintenance workload
  4. Cleaning Compatibility: Stable performance under 130°C CIP/SIP sanitary cleaning
  5. Cost Performance: Moderate price and stable performance for mid-to-high end applications
  6. Air Freight Compliance & Certification Information

6.1 Air Freight Compliance

Compliance ItemDetailed DescriptionOfficial Basis
Hazardous Goods ClassificationNon-hazardous goods, no built-in lithium battery or super capacitorIATA DGR 2026 Special Provision 9
Shipping PackageStandard industrial shockproof and moisture-proof packageIATA DGR 8.1.6
Shipping RestrictionsNo special restrictions, deliverable as general cargoIATA DGR 1.1.3.2
UN NumberUN number is not requiredNot classified as dangerous goods

6.2 Certifications

Certificate TypeExecutive StandardApplicable Scope
3-A Certificate3-A Sanitary Standard 74-05Food, beverage and pharmaceutical industry
CE CertificateEN 61326-1, EN 61010-1EU and European Economic Area
ATEX CertificateII 3G Ex nA IIC T4 Gc (Optional)Explosion hazardous area application
FDA Certificate21 CFR Part 177Food contact material safety certification
EHEDG CertificateEHEDG Type EL Class ISanitary equipment design standard
IO-Link CertificateIO-Link V1.1Industrial fieldbus communication protocol
  1. Application Scenarios & Selection Guide

Applicable Scenarios

  1. Food & Beverage Industry

Dairy industry: Flow measurement and batching control for milk, yogurt, cream

Brewery industry: Precise metering for wort, beer and cleaning solution

Juice industry: Concentration juice and syrup conveying & proportion control

  1. Pharmaceutical & Biotechnology Industry

Injection production: Accurate filling and conveying of medical liquid

Fermentation process: Flow control of culture medium and additives

Aseptic production: GMP-compliant sanitary flow measurement

  1. Chemical & Cosmetic Industry

Cosmetic production: Process control for emulsion, cream and paste products

Fine chemical industry: Precise metering of high-purity chemicals

Coating industry: Ratio control of pigment and resin

Non-recommended Scenarios

  1. Measuring non-conductive fluid (conductivity<5 μS/cm), ultrasonic flow meter is recommended
  2. Measuring fluid with solid particle content over 5%, Coriolis mass flow meter is recommended
  3. Working pressure over 40 bar, special high-pressure flow meter is required
  4. Working temperature below -10°C or above 130°C, customized model is required
  5. Ordering Information

Product Model: FMQ050SDMXX (XX stands for process connection type)

Minimum Order Quantity: 1 unit

Lead Time: 10-15 working days for standard models; 20-25 working days for customized models

Packaging Specification: Industrial anti-static package equipped with installation manual and calibration certificate

Warranty Period: 2 years under normal operating conditions

Full Introduction of Domestic Replacement Models for Anderson-Negele FMQ050SDMXX

  1. Recommended Core Replacement Models (Sorted by Matching Degree)

All below models meet core requirements: DN50 sanitary type, PFA liner, backlit display, IO-Link communication (customizable), food & pharmaceutical grade certification, compatible with CIP/SIP process, available for direct replacement.

1.1 Hangzhou Meiyi LDG-SUP-050SDM (First Choice)

ItemDetailed SpecificationsMatching Explanation
Model Code RuleLDG-SUP-050SDMHighly consistent naming rules and functional modules with original model
LDG=Electromagnetic flow meter series
SUP=Sanitary series
050=DN50
S=Standard PFA liner sensor
D=Backlit graphic display
M=IO-Link communication module
Core ParametersAccuracy: ±0.5% of reading ±2mm/sFully consistent performance parameters and sanitary standards
Flow velocity range: 0.1~10m/s
Fluid conductivity ≥5μS/cm
Wetted part: 316L electropolished stainless steel + PFA liner
Working temperature: -10°C~+130°C (30min CIP/SIP)
Protection class: Sensor IP69K, Transmitter IP67
Communication FunctionStandard IO-Link V1.1, 4~20mA analog output, 1kHz pulse output, dual signal simultaneous output100% compatible with original IO-Link functions
Qualifications & Certifications3-A, NSF/ANSI 61, FDA 21 CFR Part 177, EHEDG Type EL Class IMeet strict sanitary requirements of food and pharmaceutical industry
Cost Advantage40%~50% price of imported original productsGreatly reduce procurement cost

1.2 Chongqing Chuanyi MFS-050SDM (Leading Domestic Replacement)

ItemDetailed SpecificationsMatching Explanation
ModelMFS-050SDMFlagship sanitary model for high-end replacement
MFS=Sanitary electromagnetic flow meter series
Core ParametersAccuracy: ±0.5% of reading ±2mm/sEquivalent performance with reliable state-owned enterprise quality
Repeatability: ±0.15% of reading
Working pressure: 16bar (clamp connection)
Optional electrode: 316L / Titanium / Hastelloy
Omni-directional installation & automatic empty pipe detection
Featured FunctionsMulti-frequency excitation technology with strong anti-interference abilityMore extended functions than original model
Intelligent self-diagnosis for electrode contamination
Optional PROFIBUS / Modbus communication
Certifications3-A, CE, Optional ATEX, EHEDGMeet mainstream international sanitary standards
Service Advantage24-hour nationwide after-sales support with sufficient spare partsBetter local service than imported brands

1.3 Liance Instrument LDGW-SIN-050SDM (Cost-effective Replacement)

ItemDetailed SpecificationsMatching Explanation
ModelLDGW-SIN-050SDMSpecialized in food and pharmaceutical industry with high cost performance
LDGW=Sanitary electromagnetic flow meter
SIN=Liance brand mark
Core ParametersAccuracy: ±0.5% of readingBasic parameters fully consistent with FMQ050
Flow velocity range: 0.1~10m/s
Fluid temperature: -10°C~+130°C
Protection class: Sensor IP69K, Transmitter IP67
Communication & OutputIO-Link V1.1, 4~20mA, pulse outputIdentical functional configuration with FMQ050SDM
Support flow/volume counter reset switch input
Certifications3-A, FDA, CE, RoHSComply with international food contact safety standards
Price Level35%~45% of imported original priceOptimal choice for budget-limited projects
  1. Detailed Technical Parameter Comparison Table
Parameter CategoryAnderson-Negele FMQ050SDMXXHangzhou Meiyi LDG-SUP-050SDMChongqing Chuanyi MFS-050SDMLiance LDGW-SIN-050SDM
Measuring Performance
Accuracy±0.5% of reading ±2mm/s±0.5% of reading ±2mm/s±0.5% of reading ±2mm/s±0.5% of reading
Repeatability±0.15% of reading±0.15% of reading±0.15% of reading±0.15% of reading
Flow Velocity Range0.1~10m/s0.1~10m/s0.1~10m/s0.1~10m/s
DN50 Flow Range30~280,000L/h30~280,000L/h30~280,000L/h30~280,000L/h
Fluid Compatibility
Wetted Material316L(Ra≤0.4μm)+PFA linerSameSameSame
Fluid Temperature-10°C~+130°CSameSameSame
Working Pressure16bar (clamp)SameSameSame
Fluid Conductivity≥5μS/cmSameSameSame
Electrical & Communication
Power Supply24VDC±10%, 4WSameSameSame
Output Signals4~20mA / Pulse / IO-LinkSameSameSame
Protection ClassSensor IP69K, Transmitter IP67SameSameSame
Main Certifications3-A/FDA/EHEDG/IO-Link3-A/NSF/FDA/EHEDG/IO-Link3-A/FDA/EHEDG/CE3-A/FDA/CE/RoHS
Price Ratio100%40%~50%45%~55%35%~45%
  1. Key Points for Replacement Selection

3.1 Core Matching Requirements

Consistent Sanitary Standard: Must adopt products certified by 3-A and EHEDG, ensure Ra≤0.4 μm electropolished surface and dead-space-free design

Communication Protocol Compatibility: Confirm IO-Link V1.1 version to realize seamless system connection

Equivalent Measuring Performance: Reach standard accuracy, repeatability and low flow measuring capability

Cleaning Resistance: Stable operation under 130°C/30min CIP/SIP cleaning without liner aging

3.2 Differentiated Advantage Comparison

BrandCore AdvantagesApplicable Scenarios
Hangzhou MeiyiModerate price, complete IO-Link functions, full certificationsMid-to-high end food & beverage production line, full function compatibility required
Chongqing ChuanyiReliable quality, strong anti-interference, intelligent diagnosis functionGMP pharmaceutical workshop, high stability and long service life required
Liance InstrumentLowest price, high cost performance, fast after-sales responseSmall and medium-sized food enterprises with limited budget

3.3 Replacement Implementation Notes

  1. Installation Compatibility: All three replacement models adopt standard clamp connection with identical installation dimensions for direct replacement
  2. Wiring Matching: Consistent IO-Link pin definition, no need to modify control cabinet wiring
  3. Parameter Migration: Directly import original range, unit and alarm parameters for quick commissioning
  4. Calibration Verification: On-site calibration is recommended after replacement to meet process precision requirements
  5. Full Series Domestic Replacement Model List

Hangzhou Meiyi LDG-SUP Sanitary Series

ModelDN SizeCore ConfigurationApplication
LDG-SUP-010SDMDN10Standard, PFA liner, display, IO-LinkMicro-flow batching, laboratory
LDG-SUP-025SDMDN25Standard, PFA liner, display, IO-LinkPharmaceutical batching system
LDG-SUP-050SDMDN50Standard, PFA liner, display, IO-LinkBrewery & beverage filling (replace FMQ050)
LDG-SUP-080SDMDN80Standard, PFA liner, display, IO-LinkEdible oil production
LDG-SUP-100SDMDN100Standard, PFA liner, display, IO-LinkBulk liquid delivery

Chongqing Chuanyi MFS Sanitary Series

ModelDN SizeCore ConfigurationApplication
MFS-015SDMDN15Standard, PFA liner, display, IO-LinkSmall-batch food production
MFS-040SDMDN40Standard, PFA liner, display, IO-LinkDairy production line
MFS-050SDMDN50Standard, PFA liner, display, IO-LinkJuice production line (replace FMQ050)
MFS-065SDMDN65Standard, PFA liner, display, IO-LinkLarge-flow food production

Liance LDGW-SIN Sanitary Series

ModelDN SizeCore ConfigurationApplication
LDGW-SIN-025SDMDN25Standard, PFA liner, display, IO-LinkCosmetic production
LDGW-SIN-050SDMDN50Standard, PFA liner, display, IO-LinkFine chemical & pharmaceutical industry
LDGW-SIN-080SDMDN80Standard, PFA liner, display, IO-LinkCoating industry
  1. Quick Selection Reference Table
Demand OrientationRecommended ModelSelection Reason
Full function 100% matchingLDG-SUP-050SDMBest IO-Link compatibility and identical model definition
Highest operational reliabilityMFS-050SDMStrong anti-interference, suitable for core pharmaceutical processes
Strict budget controlLDGW-SIN-050SDMLowest cost, ideal for batch replacement
Pharmaceutical GMP workshopMFS-050SDMComplete sanitary certifications and intelligent diagnosis
Food & beverage production lineLDG-SUP-050SDMBalanced cost performance and efficient after-sales service

Prev:

Leave a Reply

Leave a message