Basic Model Definition
Catalog Number: 440R-N23114
Internal Model Code: MSR126.1T
ماركة: Allen-Bradley (روكويل أتمتة), Guardmaster Minotaur Series
Lifecycle: Active production model, manufactured in Czech Republic, standard 1-year warranty
- Core Electrical Specifications
2.1 مزود الطاقة
الجهد المقنن: 24الخامس التيار المتناوب/تيار مستمر, operating range: 0.85~1.1× rated voltage (20.4~26.4V)
استهلاك الطاقة: 4دبليو, متوافق مع 50/60 هرتز
Terminals A1/A2: Power input
2.2 Safety Inputs (Dual-channel 4-wire with cross short-circuit detection)
2 مغلقة عادة (نورث كارولاينا) safety input paths (S11-S12 / S21-S22)
Supports dual-channel emergency stop, safety door switches and safety light curtains; built-in cross-channel short-circuit fault diagnosis
Maximum input loop resistance: ≤90Ω
2.3 Reset Circuit (S33-S34)
MSR126.1T supports automatic reset and manual reset dual modes
- إعادة الضبط التلقائي: Short S33 and S34; outputs close automatically after faults are cleared
- إعادة الضبط اليدوي: Connect an external normally open reset pushbutton to S33-S34; manual push is required to restore outputs
Difference from MSR126.1R: MSR126.1R only provides monitored manual reset without automatic reset function
2.4 Safety Output Contacts (Force-guided safety contacts complying with IEC 61810-3)
2 safety normally open (لا) اتصالات: 13-14, 23-24
Load Ratings:
دي سي-13: 6A/24V DC; 3A/24V DC (for frequent switching)
ايه سي-15: 5أ/250 فولت تيار متردد
وقت الاستجابة: تقريبا. 15آنسة; Recovery Time: 100آنسة
No auxiliary alarm contacts
- Safety Certification Ratings (Top Industry Standards)
ايزو 13849-1: فئة 4 / بل ه
اللجنة الانتخابية المستقلة 61508 / اللجنة الانتخابية المستقلة 61511: سيل 3
في 954-1: Safety Category 4, فئة 0 قف
الشهادات: م, cULus, سي سي سي, BG, C-Tick
- الأبعاد الميكانيكية & تصاعد
عرض: 22.5مم (compact DIN rail mounting)
البعد الشامل: 110مم (ح) × 75mm (د) × 22.5mm (دبليو)
وزن: 160ز
المحطات: Fixed screw terminals (non-pluggable), تصنيف الحماية IP20
درجة حرارة التشغيل: -25درجه مئوية ~ +70 درجه مئوية
- Front Panel LED Indicator Meanings
- PWR (أخضر): Steady on when power supply is normal
- CH1 (أخضر): Illuminated when Channel 1 input circuit is closed
- CH2 (أخضر): Illuminated when Channel 2 input circuit is closed
All three LEDs on → Safety output contacts closed; Any single channel open → Outputs cut off
- سيناريوهات التطبيق النموذجية
- Dual-channel emergency stop button circuit monitoring
- 4-wire safety door switches (with short-circuit detection)
- Safety light curtain / light screen safety circuits
- Safety cut-off for machine tools, automated production lines and packaging equipment
Suitable for equipment requiring high safety ratings of PL e / SIL3
- Series Model Comparison for Selection
| Catalog No. | Internal Code | وضع إعادة الضبط | مزود الطاقة | تكوين القناة |
| 440R‑N23114 | MSR126.1T | Selectable Auto/Manual Reset | 24الخامس التيار المتناوب/تيار مستمر | Dual-channel 4-wire |
| 440R‑N23113 | MSR126.1R | Monitored Manual Reset Only | 24الخامس التيار المتناوب/تيار مستمر | Dual-channel 4-wire |
| 440R‑N23112 | MSR126T | Auto/Manual Reset | 230الخامس و | Dual-channel 4-wire |
- Brief Wiring Logic
- Connect 24V AC/DC power to terminals A1/A2
- Wire two NC safety switches (توقف الطوارئ / door switches) in series to S11-S12 and S21-S22 respectively
- Short-circuit S33-S34 for automatic reset; connect an NO pushbutton in series for manual reset
- Wire the safety coil of main contactors in series across terminals 13-14 و 23-24
- Disconnection of any safety input or cross-channel short-circuit will simultaneously open both NO outputs to cut power supply
- Troubleshooting Guidelines
- PWR LED off: Power phase loss, insufficient voltage or loose wiring
- Single CH1/CH2 LED off: Corresponding channel switch open or circuit wire breakage
- Both CH1 and CH2 LEDs lit but outputs fail to close: Cross-channel short-circuit fault; power cycle to reset, or reset circuit not shorted / reset button not pressed
- الاتصال باللحام: تحميل الإخراج المفرط; replace contactors with higher capacity
Full Specifications of Safety Output Contacts for Allen-Bradley 440R-N23114
- Basic Contact Structure
- كمية & يكتب: 2 independent redundant safety normally open (لا) contacts at terminals 13-14 و 23-24; no auxiliary alarm contacts or delayed outputs
- Contact Construction: Force-guided safety contacts (اللجنة الانتخابية المستقلة 61810-3), dual-channel redundant mechanical interlock. Single contact welding cannot maintain circuit conduction, fulfilling Category 4 / بل ه / SIL3 safety architecture
- مواد الاتصال: AgSnO₂ silver tin oxide, مقاومة للقوس ومضادة للحام
- Minimum Conducting Current: 10أماه (ensures reliable circuit detection by contacts)
- Rated Load Currents (Official Standard Load Categories)
2.1 AC Load (ايه سي-15, standard load for electromagnetic contactors)
250الخامس و: 6أ (inductive-resistive load, cosφ=0.35)
UL B300 certified rating: 5أ / 250الخامس و
2.2 DC Load (دي سي-13, صمامات الملف اللولبي / DC coils)
Frequent switching at 24V DC: 3أ (standard switching rating)
Low-frequency light load (0.1هرتز) at 24V DC: الأعلى. 6A for short-term use (long-term high-frequency operation not recommended)
2.3 Continuous Thermal Current Ith (static carrying current without switching)
Maximum static continuous current per single contact: 6أ (only for permanent conduction with rare break operations)
- التحمل الكهربائي & Operating Timing
- التحمل الكهربائي (220الخامس و / 4أ / cosφ=0.35)
6A breaking capacity: 100,000 العمليات
4A light load: 500,000 العمليات
- Safety Operation Timing
Response time from safety input open to contact break: ≥15 مللي ثانية
Contact pull-in recovery time after fault clearance: تقريبا. 100آنسة
- Dielectric Withstand Voltage
Withstand voltage across open contacts: AC750V for 1 دقيقة
مقاومة العزل (DC500V test): ≥1000MΩ
- External Protection & Wiring Limitations
- Recommended Fuse for Output Circuit
Slow-blow fuse: 6أ; Fast-acting fuse: 10أ. Over-rated fuses are prohibited to prevent contact ablation and welding
- Applicable Wire Gauge: 0.2~2.5mm² solid / stranded copper wires; fixed non-pluggable screw terminals
- Maximum Operating Voltage: 250الخامس و / 30في العاصمة; overvoltage is strictly forbidden
- Contact Performance Matching Safety Ratings
ايزو 13849-1: فئة 4, بل ه (independent cut-off via dual redundant contacts)
اللجنة الانتخابية المستقلة 61508: SIL3; single contact failure will not disable safety cut-off function
إيقاف الفئة: في 60204-1 فئة 0 hard cut-off stop
- Quick Load Selection Table
| نوع التحميل | الجهد االكهربى | التصنيف الحالي | سيناريوهات التطبيق |
| ايه سي-15 | 250الخامس و | 6أ | AC contactor coils |
| دي سي-13 | 24في العاصمة | 3أ | DC solenoid valves, المقاولين العاصمة |
| Static Continuous | ≤250VAC / 30VDC | 6أ | Circuits with permanent conduction and minimal breaking operations |
tic Continuous | ≤250VAC / 30VDC | 6أ | Circuits with permanent conduction and minimal breaking operations |
المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية


















NH42-63-318x560.png)