Danfoss MBS3000 060G1113 Pressure Transmitter

MBS 3000-1011-A1AB04-0 General industrial pressure transmitter, Gauge pressure, 4–20 mA output ✅ Key Specifications Measuring range: 0~1 bar (0~14.5 psi) Gauge Output signal: 4-20 مللي أمبير (2-wire) مزود الطاقة: 9~32 VDC, reverse polarity protection Pressure connection: G1/4 external thread Electrical connector: Angular DIN connector Wetted material: AISI 316L stainless steel Accuracy: Typical ±0.5%FS, max ±1%FS Response ...

  • تفاصيل المنتج

MBS 3000-1011-A1AB04-0

عام industrial pressure transmitter, Gauge pressure, 4–20 mA output

✅ Key Specifications

نطاق القياس: 0~1 bar (0~14.5 psi) Gauge

إشارة الإخراج: 4-20 مللي أمبير (2-wire)

مزود الطاقة: 9~32 VDC, حماية قطبية عكسية

Pressure connection: G1/4 external thread

Electrical connector: Angular DIN connector

مادة مبللة: AISI 316L stainless steel

دقة: Typical ±0.5%FS, max ±1%FS

وقت الاستجابة: ≤4 ms

Overpressure: 4 حاجِز; Burst pressure 6 times full scale

Medium temperature: -40~+85 ℃

درجة الحرارة المحيطة: -40~+85 ℃

No built-in pulse snubber (MBS3050 equipped with snubber)

📌 Pin Definition (Angular DIN plug)

  1. إمداد +
  2. شائع (إشارة / supply return for 4–20mA)

2-wire wiring: DC24V+ → Pin1; Pin2 → PLC AI module+; AI module→ DC24V-

🛠️ Typical Applications

التدفئة والتهوية وتكييف الهواء, ضواغط الهواء, معالجة المياه, light-duty hydraulics, low-pressure pipeline monitoring. Suitable for air, water and neutral media. Low range only, 0~1 bar, mainly used for micro / low pressure monitoring.

⚠️ Selection & ملاحظات التثبيت

  1. Medium must be compatible with 316L stainless steel; not suitable for strong corrosive media.
  2. Do not exceed 4 bar overpressure; pressure spikes may damage the diaphragm.
  3. Minimize pressure spikes during installation; MBS3050 with snubber is recommended for water hammer conditions.
  4. Check total loop resistance of the 4–20mA circuit to meet the minimum supply voltage requirement of transmitter.
  5. فئة الحماية: IP65 with connector properly tightened.

🧩 Alternative Reference

البديل المحلي: Diffused silicon pressure transmitter, G1/4, 0-1حاجِز, 4-20أماه, 316الحجاب الحاجز L

دانفوس same-series replacement: Verify range, thread and connector type. 060G1113 is 0~1 bar gauge, do not confuse with 0~4bar / 0~10bar models.

📎 Model Code Decoding (MBS3000-1011-A1AB04-0)

MBS3000: مسلسل, no pulse snubber

1: Range code 0~1 bar gauge pressure

0: Output 4–20mA

1: G1/4 pressure connection

1: Angular DIN electrical connector

A1AB04-0: بناء, seal and option codes

  1. Troubleshooting Checklist for MBS3000 060G1113 (2-wire 4-20mA)

Tools required: المتر الرقمي (أماه & V range), insulation tester; Do NOT plug/unplug DIN connector under power.

1) لا يوجد إخراج / 0mA current

  1. Power check: Measure voltage between Pin1-Pin2 of transmitter, normal operating voltage 9~32VDC. Output fails below 9V.
  2. Polarity verification: Pin1=24V+, Pin2=signal return. Reverse polarity is protected internally, transmitter will not be damaged but no output.
  3. Open circuit check: قطع الاتصال بلك جانب, insert multimeter in series to measure loop current. If still 0mA, inspect DIN connector crimping and wire breakage.
  4. Water ingress / oxidation at connector: Failed sealing of angular DIN plug causes terminal corrosion; check for water stains or green rust.
  5. Severe diaphragm damage from overpressure: Long-term pressure exceeding 4bar deforms diaphragm and damages internal sensing element.
  6. Fixed at 4mA (minimum reading, no response to pressure change)
  7. Open circuit in loop (الأكثر شيوعا): Broken wire, loose terminal or poor crimp in DIN plug.
  8. Diaphragm jammed: Medium crystallization, sludge or solid particles blocking diaphragm, pressure cannot be transferred.
  9. Internal hardware failure of transmitter, sensing element damaged.

Quick test: Disconnect transmitter, short the loop. If PLC reads ~20mA, PLC module and wiring are good, fault lies in transmitter.

  1. Fixed at 20mA (full scale reading, no response to pressure change)
  2. Short circuit in loop: Cable insulation damage causing short between positive and negative cores, shorted terminals inside DIN plug.
  3. Permanent damage caused by sustained overpressure; bulged diaphragm locks sensor output at full scale.
  4. Strongly corrosive medium penetrates 316L diaphragm and causes internal leakage.

Quick test: Remove transmitter, if PLC reading drops back, module is healthy, fault in transmitter or field wiring.

  1. انحراف الإشارة (zero offset, reading slowly fluctuates while pressure remains stable)
  2. Thermal drift: Medium temperature out of range -40~85℃ or drastic temperature cycling. MBS3000 has no high-grade temperature compensation chip, drift occurs under extreme temperature.
  3. Residual stress on diaphragm: Excessive tightening torque transfers stress to diaphragm; Recommended max torque ≤25 Nm for MBS3000.
  4. Medium deposit: Oil scale or limescale adheres to diaphragm and gradually shifts zero point.
  5. Unstable power supply: High ripple on switching power supply causes voltage fluctuation.
  6. Aging drift: Degradation of sensing element after long service time.

معايرة: Vent to atmospheric pressure to check if reading returns to 0bar (4أماه). Large deviation requires zero correction, MBS3000 has no local zero adjustment knob, correction can only be done via controller software.

  1. تقلب الإشارة / noisy reading
  2. Electromagnetic interference (top reason)

Ground loop caused by shield grounding at both ends. Correct practice: Shield grounded only at control cabinet end, shield at transmitter end kept floating.

Signal cable routed together with power cables (المقاولين, motor cables). Separate routing with minimum distance ≥30cm; cross cables perpendicularly, avoid parallel laying.

  1. Pressure shock / water hammer: Instant pressure spikes vibrate diaphragm even for 0~1bar range; switch to MBS3050 with built-in snubber if water hammer exists.
  2. محطات الأسلاك فضفاضة: Poor crimp of DIN terminals, contact resistance varies under vibration.
  3. Insufficient filtering on PLC module: Short filter time on AI channel amplifies noise. Increase channel filtering time.
  4. Air bubbles in medium: Bubbles hitting diaphragm cause signal jitter for liquid pipelines.
  5. Intermittent fault (reading unstable, works occasionally)

Vibration loosens connector or causes internal wire break at bending points.

Insulation expansion/contraction with temperature change leads to intermittent short/open circuit.

Condensation inside plug under high humidity, intermittent connection.

  1. Danfoss Same Series Comparison (MBS3000 / MBS3050 / MBS3100)
نموذجسماتطلبDifference vs MBS3000 060G1113
MBS3000General economy type, no snubber, fast response ≤4ms, 316الحجاب الحاجز L, 4-20mA/0-10V optionalالتدفئة والتهوية وتكييف الهواء, ضاغط الهواء, clean water, stable pressure without spikesالنموذج المرجعي, no pulse snubber, low range 0~1bar
MBS3050MBS3000 base with built-in pulse snubber, suppress water hammer and pressure spikesPump outlet, pipeline with pressure shock / water hammerIdentical mechanical dimension, built-in snubber slows response; direct mechanical replacement available
MBS3100حجم صغير, stainless housing, IP67, better vibration resistanceمساحة التثبيت محدودة, mobile equipment, high vibration environmentSmaller body; خيط & connector vary for some versions; not mechanically interchangeable without verification

Other Danfoss Pressure Transmitter Series (البدائل)

  1. MBS4500: High accuracy version, ±0.25%FS, high EMC immunity; precision process and lab use; higher price than MBS3000.
  2. MBS5100: Heavy-duty industrial, high overpressure rating for heavy hydraulics and high-pressure systems; thick diaphragm, not suitable for 0~1bar micro pressure measurement.
  3. MBS9200: Differential pressure transmitter for measuring pressure difference between two points, cannot replace gauge pressure MBS3000.

✅ Replacement Selection Checklist (for 060G1113)

يؤكد 4 parameters at the same time:

  1. Pressure type: Gauge, measuring range 0~1 bar
  2. الإخراج: 2-wire 4-20mA
  3. Pressure connection: G1/4 external thread
  4. Electrical connector: Angular DIN connector

Danfoss MBS3000 060G1113 Installation Instructions (0~1bar, G1/4, Angular DIN)

Divided into mechanical installation, التركيبات الكهربائية, واسطة & operating condition, pre-commissioning check and prohibited operations, tailored for this low-range gauge transmitter.

  1. التركيب الميكانيكي (G1/4 external thread)
  2. تشديد عزم الدوران: Recommended ≤25 N·m. Never use wrench on black plastic DIN connector; only clamp the metal hexagon for tightening. Excessive torque creates residual stress on diaphragm, zero drift and permanent sensor damage.
  3. Thread sealing: G1/4 is non-sealing cylindrical pipe thread. PTFE tape or thread sealant is recommended. Wrap PTFE tape on external thread, do not wrap tape to thread tip to prevent debris entering pressure cavity and blocking diaphragm. Thick gaskets for lifting transmitter are prohibited.
  4. اتجاه التركيب

Liquid pipeline: Mount diaphragm horizontally or facing downward to avoid air bubbles trapped on diaphragm surface causing signal noise.

Gas pipeline: Mount diaphragm upward to prevent condensate accumulating on diaphragm.

Cable entry of angular DIN plug points downward, preventing rainwater / condensate flowing into plug and breaking IP65 protection.

  1. Pressure tap selection

Tap hole on side of pipeline, avoid bottom (sediment accumulation blocking diaphragm) or top (تراكم الغاز).

Add short nipple and support bracket for high vibration pipeline to reduce vibration transfer to transmitter.

  1. Pressure protection (this model only 0~1bar range)

Max continuous overpressure 4 حاجِز. Burst pressure is much higher, but instantaneous water hammer spike can easily rupture diaphragm. MBS3000 has no built-in snubber, switch to MBS3050 if pressure spike / water hammer exists.

Remove transmitter or isolate with shut-off valve before pipeline hydro test. Never perform pipeline purging with transmitter mounted, high-speed particles scratch 316L diaphragm.

  1. Thermal isolation: Fit cooling nipple / heat dissipation sleeve when medium temperature approaches upper limit 85℃, reduce heat conduction to transmitter body and avoid thermal drift.
  2. التركيبات الكهربائية (Angular DIN EN175301-803-A, 2-wire 4-20mA)
  3. Power-off wiring rule: Disconnect 24V power before wiring or plug/unplug DIN connector. Arcing under live condition may damage internal circuit.
  4. تعيين الدبوس: Pin1 = 24V+; Pin2 = signal return (-); Pin3 unused. Polarity must be correct. Reverse polarity protected but no output.
  5. Cable selection & shielding

مُستَحسَن: 0.5~0.75mm² shielded twisted pair cable; use 0.75mm² for distance >100م.

درع: Ground shield only at control cabinet end, leave shield floating at transmitter DIN plug side. Grounding at both ends creates ground loop and signal noise.

Separate signal cables from power cables, minimum distance ≥30cm; cross perpendicularly, avoid parallel routing.

  1. Loop load: Max allowable loop resistance approx. 600Ω at DC24V supply; PLC AI module internal resistance ≤250Ω normally, meets requirement.
  2. فئة الحماية: IP65 only when DIN plug fully tightened and intact sealing gasket fitted. مفتقد / damaged gasket causes water ingress and terminal corrosion.
  3. واسطة & Ambient Requirements
  4. Wetted material AISI316L stainless steel: Medium must be compatible with 316L. Clean water and compressed air are acceptable. Not suitable for strong acid, strong alkali or high chloride corrosive medium. Medium cannot contain large solid particles to avoid diaphragm scratch.
  5. نطاق درجة الحرارة

Medium temperature: -40 ~ +85℃

درجة الحرارة المحيطة: -40 ~ +85℃

Temperature out of range increases thermal drift significantly or permanently damages sensing element.

  1. بيئة: Avoid direct long-time sunlight, اهتزاز قوي, strong electromagnetic equipment (العاكس, قواطع) installed nearby. Transmitter housing can connect protective earth.
  2. Pre-commissioning Check List
  3. ميكانيكية: Confirm thread leak-free, correct tightening torque, pressure shut-off valve closed.
  4. كهربائي: Verify wiring with multimeter, no short / دائرة مفتوحة; double check Pin1/Pin2 polarity before power-up.
  5. No-load calibration after power on: Vent to atmospheric pressure (0حاجِز), loop current should read 4mA.
  6. Slowly open pressure valve and pressurize gradually, sudden full opening causing pressure shock is prohibited. Check current 20mA at full scale 1bar.
  7. Monitor reading for 5~10 minutes, confirm stable reading without drift or noise.
  8. العمليات المحظورة

❌ Do NOT tighten transmitter by clamping black plastic DIN connector with wrench

❌ Do NOT perform pipeline purging or pressure test with transmitter mounted

❌ Do NOT subject to sustained pressure over 4 bar or instantaneous water hammer shock

❌ Do NOT ground cable shield at both ends

❌ Do NOT exceed medium temperature limit 85℃

❌ Do NOT touch diaphragm with hard objects; scratched or dented diaphragm is permanently damaged

❌ MBS3000 has no local zero adjustment knob, do NOT disassemble transmitter for calibration

  1. Recommended Accessories for Installation

Pressure shut-off valve (for isolation and transmitter replacement online)

Cooling nipple (high temperature medium)

PTFE thread tape

Shielded twisted pair cable

Spare sealing gasket for DIN plug

Danfoss Industrial Pressure Transmitter Product List (MBS / DST / AKS)

Grouped by application, highlight difference vs MBS3000 (060G1113) for model selection & استبدال

  1. Main MBS Industrial Series
  2. MBS1200 / MBS1250|Compact OEM for mobile hydraulics

MBS1200: No pulse snubber; MBS1250: Built-in pulse snubber

طلب: Construction machinery, mobile hydraulics, on-board equipment; high vibration & shock resistance

الإخراج: Mostly ratiometric voltage output, few 4-20mA types; Max medium temp 125℃

يتراوح: 0~10bar to 0~600bar

  1. MBS1700 / MBS1750|Economical general transmitter

MBS1700: No snubber; MBS1750: With pulse snubber

طلب: التدفئة والتهوية وتكييف الهواء, ضاغط الهواء, معالجة المياه, low-cost alternative for MBS3000

دقة: ± 0.5% فس; 316الحجاب الحاجز L; angular DIN plug, similar outline to MBS3000

  1. MBS3000 / MBS3050【Your reference series】

MBS3000: No pulse snubber, fast response ≤4ms; reference model 060G1113 (0~1bar gauge, G1/4, angular DIN, 4-20أماه)

MBS3050: Same outline, built-in pulse snubber, suppress water hammer and pressure spikes; preferred for pump outlet

الإخراج: 4-20أماه, 0-10V; gauge / absolute pressure optional; range 0~1bar~0~600bar; wetted AISI316L

Typical industry: التدفئة والتهوية وتكييف الهواء, ضاغط الهواء, clean water, low-pressure process

  1. MBS3100 / MBS3150|Compact small size

MBS3100 no snubber, MBS3150 with snubber; compact footprint for limited mounting space

حماية IP67; better vibration resistance than MBS3000; multiple thread options; different housing, cannot mechanically replace MBS3000 without verification

  1. MBS3200 / MBS3250|High temperature type

MBS3200 no snubber, MBS3250 with snubber; high medium temperature version

Suitable for hot water, heat traced pipeline, high temperature process medium

  1. MBS3300 / MBS3350|Compact high temperature

Dedicated high temperature application; withstand higher medium temperature; 316L wetted part; الماء الساخن & hot oil circuit

  1. MBS33 / MBS33M|Marine high accuracy

MBS33M: Marine certified version, high vibration & EMC immunity, class certification; range 0~1bar~600bar

Accuracy ±0.3%FS; 4-20أماه; gauge / absolute pressure; seawater and marine pipeline pressure monitoring

  1. MBS4000 / MBS4050|High accuracy general industrial

MBS4000 no snubber; MBS4050 with snubber; accuracy ±0.3%FS; support field zero & span adjustment

Industrial process, precision pressure monitoring; higher accuracy than MBS3000

  1. MBS4201 / MBS4251|Explosion-proof (Ex)

MBS4201 no snubber; MBS4251 with snubber; intrinsically safe certified for hazardous area (كيميائية, غاز)

4-20mA 2-wire; 316الحجاب الحاجز L; 普通MBS3000 cannot be used in explosion hazardous area

  1. MBS4500 / MBS4510|High accuracy field calibratable

MBS4500: Basic high accuracy; MBS4510: With flush diaphragm; accuracy ±0.25%FS

Built-in zero and span adjustment; lab & precision process; تكلفة أعلى

  1. MBS4701 / MBS4751|Explosion-proof high accuracy

MBS4701 no snubber; MBS4751 with snubber; مقاومة للانفجار + دقة عالية; chemical hazardous process

  1. MBS5100 / MBS5150|Heavy-duty industrial / heavy hydraulics

MBS5100 no snubber; MBS5150 with snubber; thick diaphragm, high overpressure rating; heavy hydraulics, التعدين, high pressure pump station

Range starts from high pressure, not suitable for 0~1bar micro pressure measurement

  1. MBS8200 / MBS8250|New generation heavy-duty high performance

MBS8200 no snubber; MBS8250 with snubber; superior EMC immunity (100V/m); max medium temp 125℃; functional safety available

Mobile hydraulics, high pressure shock application

  1. MBS9200 / MBS9300|Differential pressure transmitter

Differential pressure measurement (pressure difference between two points), not gauge pressure; تدفق & level DP measurement; cannot replace gauge pressure MBS3000

  1. DST Series New Generation Digital / Corrosion Resistant Transmitter
  2. DST P300 / DST P30M: General digital pressure sensor, 4-20أماه / digital signal, compact form
  3. DST P40M: Stainless steel general model
  4. DST P40I: Titanium wetted part, for corrosive medium (seawater, chemical brine), corrosion upgrade alternative for 316L
  5. AKS Series (التدفئة والتهوية وتكييف الهواء & Refrigeration dedicated Danfoss product line)

Mainly for chiller, التخزين البارد, refrigerant pressure monitoring, not recommended for general water / compressed air process

AKS 32: Refrigeration pressure transmitter, 4-20أماه

AKS 33: Refrigeration high/low pressure, dedicated for R-series refrigerant

AKS 4100: Refrigerant pressure sensor

EMP2 Embedded Pressure Sensor

OEM miniature pressure sensor, built-in equipment installation, rarely used as standalone field transmitter

📋 Quick Selection Comparison Table

مسلسلSnubberدقةالتطبيق الرئيسيReplace MBS3000 060G1113?
MBS3000لا± 0.5% فسالتدفئة والتهوية وتكييف الهواء, ضاغط الهواء, clean water low pressure✅ Direct mechanical replacement if parameters match
MBS3050Built-in pulse snubber± 0.5% فسPipeline with water hammer & pressure spike✅ Same mechanical interface, signal unchanged, استجابة أبطأ
MBS1700لا± 0.5% فسEconomical HVAC & ضاغط الهواء✅ Similar outline, verify thread & connector
MBS4500لا±0.25%FSPrecision process❌ Different outline, دقة أعلى & يكلف
MBS5100خياري± 0.5% فسHeavy-duty high pressure hydraulics❌ Diaphragm design unsuitable for 0~1bar micro pressure
MBS4201خياري± 0.5% فسExplosion hazardous area❌ Explosion-proof model, unnecessary for normal area
MBS9200Differential pressure± 0.3% فسDP measurement❌ Different measuring principle, cannot replace gauge pressure

✅ 4 Parameters to Verify for MBS3000 060G1113 Replacement

  1. Pressure type: Gauge, measuring range 0~1 bar
  2. الإخراج: 2-wire 4-20mA
  3. Pressure connection: G1/4 external thread
  4. Electrical connector: Angular DIN connector

 