قاطع الدائرة الكهربائية شنايدر GV3P50

The Schneider GV3P50 motor circuit breaker is an ideal choice for protecting 22kW three-phase motors. Featuring thermal-magnetic tripping, an adjustable current range of 37–50A, a breaking capacity of 100kA and IP20 ingress protection rating, it is widely deployed in industrial automation, fluid conveyance, building facilities and other sectors. Key points: match breaker rating to motor ...

  • تفاصيل المنتج

The Schneider GV3P50 motor circuit breaker is an ideal choice for protecting 22kW three-phase motors. Featuring thermal-magnetic tripping, an adjustable current range of 37–50A, a breaking capacity of 100kA and IP20 ingress protection rating, it is widely deployed in industrial automation, fluid conveyance, building facilities and other sectors. Key points: match breaker rating to motor power and operating conditions; avoid non-recommended applications including DC circuits, high-frequency starting and high-altitude environments. Combined with contactors and auxiliary contacts, it forms a complete motor protection and control system.

مقطع الكودتعريفوصف تفصيلي
GV3سلسلة المنتجاتTeSys GV3 range motor circuit breakers for three-phase motor protection
صنوع المنتجStandard thermal-magnetic trip unit with rotary knob operation
50التصنيف الحاليMax adjustable trip current 50A; thermal trip setting range: 37–50A
النموذج الكاملGV3P503-pole thermal-magnetic motor breaker, 37–50A, EverLink BTR screw terminals, IP20
رمز الطلبFD6887Schneider official standard part number
  1. Core Technical Specification Table
فئة المعلمةالبيانات الفنيةملاحظات
المعلمات الأساسية
تكوين القطب3ص (3-القطب)For three-phase AC circuits
نوع الرحلةThermal-MagneticCombines thermal overload protection & magnetic short-circuit protection
وضع التشغيلRotary Knob ControlManual switching with ON/OFF marking
الإنهاءEverLink BTR screw-clamp terminalsFast wiring to reduce loose connection risks
المعلمات الكهربائية
Thermal Trip Adjustment37–50ACompatible with motors of different rated powers
تصنيف الجهد التشغيلي (واجهة المستخدم)690الخامس و50/60هرتز
تصنيف الجهد العزل (إي)690الخامس ومتوافق مع IEC 60947-2
تصنيف التشغيل الحالي (أي)50أMaximum continuous operating current
تيار الرحلة المغناطيسي700أShort-circuit instantaneous tripping value
Ultimate Breaking Capacity (وحدة العناية المركزة)100الAt 400V
Matched Motor Rating22كيلو واط @ 400 فولتFor three-phase asynchronous motors
ميكانيكية & Ambient Parameters
حماية الدخولIP20Finger-touch safe against live components
تصاعدتركيب السكك الحديدية DINStandard 35mm top-hat rail
وزنتقريبا. 0.45كجمتركيب سهل & transportation
درجة حرارة التشغيل-25درجة مئوية ~ +60 درجة مئويةSuitable for most industrial environments
درجة حرارة التخزين-40°C ~ +85°CWide storage temperature range
الشهادات
Main Approvalsم, أول, وكالة الفضاء الكندية, سي سي سي, مجموعة شرق أفريقياGlobally certified per international standards
Eco Certificationsبنفايات, REACHEU-compliant environmentally friendly design

ثالثا. Full GV3P Series Model List

نموذجThermal Trip RangeMatched Motor Power @400Vتيار الرحلة المغناطيسيرمز الطلب
GV3P4025–40A18.5كيلوواط600أFD6886
GV3P5037–50A22كيلوواط700أFD6887
GV3P6548–65A30كيلوواط800أFD6888
GV3ME5037–50A22كيلوواط700أFD6890
GV3ME6548–65A30كيلوواط800أFD6891
GV3ME8056–80A37كيلوواط1000أFD6892
GV3ME10070–100A45كيلوواط1200أFD6893
  1. Alternative Cross Reference (نماذج الاستبدال)
  2. In-house Schneider Replacement
النموذج الأصلياستبدالوصف
GV3P50GV3ME50Identical performance; ME is enhanced version with better accessory compatibility
GV3P50New production GV3P50No functional change, only production batch update
  1. Cross-Brand Equivalents
ماركةالنموذج المعادلMatching Gradeالمزايا
ايه بي بيMS132-50★★★★★Same current rating, interchangeable mounting dimension
سيمنز3RV2031-4KA10★★★★☆رحلة حرارية مغناطيسية, fits 22kW motors
إيتونPKZM0-50★★★★☆3-تصميم القطب, 100كا كسر القدرة
شينتNDM2-63M/3300★★★☆☆Cost-effective for bulk replacement
لذيذCDM1-63M/3300★★★☆☆Well-known domestic brand with high cost-performance
  1. Application Environments & Field Cases
  2. Recommended Applications

الأتمتة الصناعية: الزائد & short-circuit protection for 3-phase asynchronous pumps, fans and compressors

تصنيع: Production line motor control & machine tool protection

كهرباء البناء: Central air-conditioning & fire-fighting pump control

Energy Sector: Front-end protection for small generator sets and inverters

بنية تحتية: Wastewater treatment equipment & bulk material conveying systems

  1. Non-Recommended Applications

DC Circuits: Designed exclusively for AC; abnormal tripping characteristics under DC supply

Ultra-Frequent Cycling: Not applicable for >30 starts per hour (accelerates trip unit aging)

High Altitude: Derating mandatory above 2000m elevation

Corrosive Atmosphere: No anti-corrosion coating; unsuitable for strong acid/alkali surroundings

  1. حالات التطبيق النموذجية

قضية 1: Fan System Protection for Food Processing Plant

معدات: 3×22kW centrifugal fans, 380V/50Hz

حل: GV3P50 + LC1D65 contactor combination

حصيلة: Triple protection against overload, ماس كهربائى & خسارة المرحلة; equipment failure rate reduced by 40%

قضية 2: Submersible Sewage Pump Control at Wastewater Plant

معدات: 4×22kW submersible sewage pumps, 380V/50Hz

حل: GV3P50 + اتصالات مساعدة + PLC interlock control

حصيلة: Full motor protection plus remote monitoring, lower maintenance expense

  1. Air Shipment Compliance & شهادة CE
  2. الامتثال للشحن الجوي

UN38.3: غير مطلوب; no built-in lithium battery or supercapacitor inside

فئة الشحن: General commodity without special transport restriction

Packing: Standard industrial carton to avoid transit damage

Shipping Document: Copy of CE certificate + RoHS compliance declaration available

  1. CE Certification Details

المعايير المعمول بها: اللجنة الانتخابية المستقلة 60947-2 (LV switchgear) & اللجنة الانتخابية المستقلة 60947-4-1 (motor control equipment)

Valid Region: European Economic Area (EEA) & global territories accepting CE marking

Validity: Permanently valid complying with current normative requirements

سؤال: Check Schneider official website product page or certification database

سابعا. استكشاف أخطاء الأخطاء الشائعة وإصلاحها

Fault SymptomProbable CausesRemedial Actions
Frequent thermal tripping1. الزائد للمحرك1. Inspect motor load
2. Underset trip current2. Adjust rotary knob to correct setting
3. Excess ambient temperature3. Improve ventilation or derate operating current
Unable to close1. Tripping latch not reset1. Toggle knob OFF then ON to reset
2. Short circuit in wiring2. Troubleshoot short-circuit faults
3. التشويش الميكانيكي3. Clean or replace breaker
No protection upon phase loss1. الأسلاك الخاطئة1. Recheck three-phase cabling
2. Damaged trip unit2. Replace trip component
3. Severe 3-phase unbalance3. Balance connected loads
Overheated terminals1. Loose terminals1. Retighten terminal screws
2. Undersized cable2. Upgrade to proper wire gauge
3. Terminal oxidation3. Clean terminals or replace unit

ثامنا. Sizing Guidelines & Quick Selection Rules

Quick Selection Formula Summary

> GV3P series 3-pole thermal-magnetic breakers;

> Suffix number denotes upper current limit;

> 40 = 25–40A, 50 =37–50A, 65 max at 65A;

> Power matching rule: 40 for 18.5kW, 50 for 22kW, 65 for 30kW.

القواعد السريعة

  1. المطابقة الحالية: Motor rated current ×1.1 ≤ breaker setting ≤ motor rated current ×1.3
  2. Power Reference: At 400V, GV3P50 matches 22kW motor (~44A nominal)
  3. Accessory Option: الاتصال المساعد: GV3AE11 (1لا + 1NC) / GV3AE20 (2لا)
  4. Mounting Spacing: DIN rail install; ≥10mm clearance for heat dissipation, away from heat-generating devices
  5. تثبيت & Wiring Instruction
  6. خطوات التثبيت

Confirm standard 35mm DIN rail

Snap breaker firmly onto rail

Incoming power: top-feed or bottom-feed acceptable

Motor cable connection: terminal tightening torque 2.5Nm recommended

  1. مواصفات الأسلاك

Wire cross-section range: 1.5mm² min ~35mm² max

صالة: EverLink BTR screw terminal compatible with copper/aluminum conductors

Phase marking: R/S/T corresponds to L1/L2/L3; no neutral connection (3P without N pole)

  1. EMC Protection

Maintain ≥50mm clearance between breaker and contactors

Separate control wiring from power cables to avoid cross-interference

Install EMC filter if needed for EMI suppression

Full Application Overview for Schneider GV3P50 Motor Circuit Breaker

  1. Core Application Summary

Schneider GV3P50 is a 3-pole thermal-magnetic motor circuit breaker with adjustable trip 37–50A, rated for 22kW three-phase asynchronous motors @400V. Its core functions: motor overload, ماس كهربائى & phase-loss protection plus manual switching, widely used in below industries:

  1. Detailed Application Classification
  2. الأتمتة الصناعية & تصنيع
طلبمعداتProtection RequirementApplication Benefit
Production Line Controlالناقلون, sorters, packaging machinesContinuous running protection against overload shutdownImprove line stability & reduce breakdown loss
أدوات الآلةMilling, lathe & grinder spindle motorsProtection for frequent start-stop & instant short-circuit breakingProtect costly equipment and extend service life
Bulk HandlingBucket elevators, screw conveyorsStall & phase-loss protectionPrevent burnout & cut maintenance cost
الآلات العامةPrinting, textile & plastic processing machinesحماية الزائد + emergency manual cut-offSimplify control circuit & enhance operational safety
  1. Fluid Conveyance Systems
طلبمعداتProtection FeatureTypical Parameter
Pump SetIndustrial pump, fire pump, مضخة مياه الصرف الصحيDual overload + phase-loss protection, moisture-resistant22كيلوواط/380 فولت,50هرتز, setting 37–50A
Fan UnitCentrifugal/axial/induced draft fansLight-load startup protection against impeller jammingAdapt to current fluctuation from variable duct resistance
CompressorAir & ضواغط التبريدHeavy-start & overheat protectionTolerate frequent loading/unloading cycles
Vacuum Pumpصناعي & water-ring vacuum pumpsLow-current idle-running damage preventionAdjustable setting for light-load operation
  1. مبنى & Municipal Infrastructure
SectorنظامKey Demandطريقة التركيب
التدفئة والتهوية وتكييف الهواءCentral air-con, air handler, cooling towerStable continuous-duty protectionDIN rail mounted with contactor interlock
أتمتة البناءFire control, security & elevator room equipmentEmergency cut-off safetyRemote monitoring via PLC
WastewaterAerator & sludge processing unitsتراب & moisture resistanceCabinet installation with IP20 protection
الطاقة الجديدةSmall gen-set & PV inverterالتيار الزائد & grid-fault isolationRated up to 690V high-voltage system
  1. Other Industrial Sectors
صناعةمعداتSpecial RequirementMatching Advantage
زراعةIrrigation pump & feed processorOutdoor installation against grid voltage swingWide operating temp: -25درجة مئوية~+60 درجة مئوية
MiningSmall conveyor & mine ventilation fanHeavy startup + high short-circuit withstand100kA high breaking capacity
طعام & BeverageMixer & معدات التعقيمSanitary & easy-clean layoutNo exposed live parts for hygiene compliance
PharmaPharmaceutical & cleanroom machineryتحكم دقيق & معدل فشل منخفضHigh accuracy thermal-magnetic trip characteristic

ثالثا. Non-Recommended Applications (Avoidance Guide)

Unsuitable Conditionسببالحل البديل
DC CircuitAbnormal tripping characteristic under DC (rated only AC 50/60Hz)Dedicated DC-rated Schneider circuit breakers
>30 Starts/HourAccelerated trip unit ageing & shortened service lifeGV3ME enhanced series or match with soft starter
Altitude>2000mPerformance derating requiredHigh-altitude specified breaker or add upstream protection
Strong Corrosive AtmosphereUncoated terminals prone to oxidationAnti-corrosion coated model or protective enclosure
Explosion Hazard ZonesStandard version without ATEX certificationATEX certified explosion-proof breakers
Single-Phase Motors3-pole structure cannot provide single-phase protectionGV2 single-phase motor breaker series
  1. Detailed Field Application Cases

Case1: 22kW Fan Protection in Food Factory

Setup: 3×22kW centrifugal fans 380V/50Hz, independent control per unit

مخطط: GV3P50 + LC1D65 contactor + GV3AE11 auxiliary contact

Logic: Manual/Auto switch; auto stop & alarm upon overload

Result: Triple protection realized; failure rate -40%, maintenance cost -30%

Case2: Submersible Sewage Pump Control at WWTP

Setup: 4×22kW submersible sewage pumps 380V/50Hz, alternating operation

مخطط: GV3P50 + PLC interlock + level transducer

Condition: بيئة رطبة, 10~15 starts/hour frequent cycling

Result: Anti-stall burnout + remote auto-switching, improved system reliability

Case3: Central Air-conditioning for Shopping Mall

Setup: 3×22kW chilled water pumps with VFD control 380V/50Hz

مخطط: GV3P50 + inverter + temperature sensor

ميزة: Speed auto-adjust by return water temp; coordinated protection by inverter + breaker under overload

Result: ≥30% energy saving, service life doubled, superior system stability

  1. Recommended Matching Components & نصائح الاختيار
  2. Recommended Matching List
ملحقرقم الجزء.وظيفةقيمة
موصل التيار المترددLC1D65Remote control for frequent start-stopEnable automatic control & reduce manual operation
الاتصال المساعدGV3AE111NO+1NC signal outputAlarm feedback or PLC interlock
مرحل الحمل الزائد الحراريLRD4363Optional secondary overload protectionDouble motor protection for enhanced safety
Control PushbuttonXB4 SeriesManual start/stopواجهة المستخدم البشرية & emergency shutdown function
  1. Sizing Rules
  2. Power Match: 22كيلوواط (~44A @400V) optimally paired with GV3P50 (37–50A)
  3. Trip Setting: Motor rated current ×1.1 ≤ breaker setting ≤ motor rated current ×1.3
  4. Mount Clearance: ≥50mm gap to adjacent contactors; ≥10mm free space for heat dissipation
  5. Wiring Torque: Cable terminal tightening torque fixed at 2.5Nm
  6. Ambient Derate: ديراتي 1% rated current per every 1°C rise above +40°C ambient temperature