CHINT NXC-65A AC Contactor

  Model Segment Description NXC Product series code: CHINT KunLun series AC contactor, upgraded replacement for traditional CJX2 series 65 Bemessungsbetriebsstrom: 65A (unter AC-3, 400V) A Configuration code: Standardtyp (no suffix = standard; suffix /N = reversing type) Common Suffix Coil voltage code: 220V / 380V / 110V / 24V, z.B. NXC-65 ...

  • Produktdetails

 

ModellsegmentBeschreibung
NXCProduct series code: CHINT KunLun series AC contactor, upgraded replacement for traditional CJX2 series
65Bemessungsbetriebsstrom: 65A (unter AC-3, 400V)
AConfiguration code: Standardtyp (no suffix = standard; suffix /N = reversing type)
Common SuffixCoil voltage code: 220V / 380V / 110V / 24V, z.B. NXC-65 220V

Full Model Example:

NXC-65 220V 50Hz = CHINT KunLun 65A AC contactor, coil voltage 220V, 50Hz, Standardkonfiguration

Typical Order No.: 710010100000281 (NXC-65 220V 50Hz, 1NO+1NC)

  1. Main Technical Data
KategorieSpezifikationenBemerkungen
Grundlegende Informationen
Marke / SerieCHINT Electric / KunLun NXC SeriesKompakte Struktur, direct replacement for CJX2-65
Produkttyp3-phase AC ContactorFor frequent motor starting & remote circuit switching
Compliance-StandardsGB/T 14048.1 / IEC 60947-1, GB/T 14048.4 / IEC 60947-4-1International certified, sicher und zuverlässig
Electrical Data
Nennbetriebsstrom (Dh)65A (AC-3, 400V)Main contact rated current
Nennbetriebsspannung (Ue)380V / 400V (50Hz)Standard industrial grid voltage
Bemessungsisolationsspannung (Ui)690VMax withstand voltage of insulation system
Bewertete Stoßspannungsfestigkeit (Ump)8kVOvervoltage protection capability
Control Coil VoltageOptional AC 24V / 36V / 110V / 220V / 380VSelected according to control system
Coil Frequency50 / 60HzGlobal grid compatibility
Rated Operating Frequency1200 cycles/h (AC-3)High frequent operation capability
Bruchkapazität10× NennstromShort-circuit withstand capability
Kontaktkonfiguration
Main Contacts3NEIN (3-Pol normalerweise offen)Standard for main power circuit
Hilfskontakte1NEIN + 1NCExpandable on request
Hilfskontaktbewertung5A / 220V undFor control signal circuits
Physikalische Eigenschaften
Abmessungen (B×H×T)90mm × 150mm × 105mmKompakt, platzsparend
GewichtCa. 0.8kgLightweight for easy installation
MontageStandard 35mm DIN rail / screw mountingSnap-on design, fast assembly
SchutzklasseIP20Suitable for cabinet installation
Betriebstemperatur-30℃ ~ +60℃Wide temperature range for harsh environments
Lagertemperatur-25℃ ~ +40℃Suitable for transportation & warehouse storage
Electromagnetic Performance
SpulenleistungCa. 180VA (pick-up) / 25VA (holding)Geringer Stromverbrauch, energy-saving
Abfallspannung30% ~ 70% of rated voltageReliable disconnection
Electromagnetic SystemOptimized silicon steel lamination (32-piece core)Smooth closure, geräuscharm & loss
Sicherheitsfunktionen
ZertifizierungenCE, CCCInländisch & international compliance
Arc ExtinctionMulti-channel magnetic blow-out arc suppressionHigh breaking performance
SchutzfunktionenÜberstrom, Überhitzung, undervoltage protectionComprehensive equipment & circuit protection
  1. Accessory List
ZubehörModellFunktionMounting Position
Auxiliary Contact BlockAX-3M/20 (2NEIN), AX-3M/02 (2NC), AX-3M/11 (1NO+1NC)Expand auxiliary contacts for complex logicTop front
Time Delay ModuleF5-08 (0.1~30s), F5-11 (0.1~180s)On-delay / off-delay controlTop
Surge SuppressorSR2-220, SR2-380Suppress coil surge voltageBottom
Mechanische VerriegelungNXC-ILPrevent phase short circuit for reversing contactor (NXC-65/N)Side
Mounting Rail35mm standard DIN railFixed installationInside control cabinet
Terminal Protection CoverStandard equippedAnti-touch protectionHauptsächlich & auxiliary terminals
Mounting ScrewsM4×12mmSchraubenbefestigungBase mounting holes
Operation ManualElektronisch / hard copyInstallation, commissioning & maintenance guide
Coil ConnectorOptionalFast coil wiring & ErsatzCoil terminal side
  1. Cross-Brand Equivalent & Ersatz
MarkeSerieModellNennstromUnterschiedeErsatzkompatibilität
CHINTCJX2CJX2-651165AOld generation; NXC is fully upgraded versionDirect full replacement (same mounting size)
SchneiderTeSys DLC1D65M7C65AImport brand, höhere Kosten, similar functionsHoch (verify mounting & Hilfskontakte)
Siemens3RT3RT2026-1BB4065AModularer Aufbau, hot-swap supportMedium (different dimension & Verdrahtung)
ABBVONAF65-30-1165AWide-voltage coil, global applicationMedium (needs position adjustment)
MitsubishiS-NS-N6565ACompact Japanese design, moderater PreisMedium (different terminal layout)
ChangshuCK3CK3-6565ADomestic equivalent, same performanceHoch (fully compatible size & Montage)
  1. Hauptfunktionen & Anwendungen

Kernfunktionen

  1. High-efficiency Electromagnetic System: Optimized core structure for stable closure, low noise and low energy consumption.
  2. Highly Reliable Arc Suppression: Magnetic blow-out technology with 10× rated breaking capacity for higher safety.
  3. Flexible Expansion: Supports auxiliary contacts, timer modules and surge suppressors for customized control.
  4. Einfache Installation: Snap-on DIN rail mounting for fast assembly and maintenance.
  5. Wide Temperature Adaptation: Stable operation from -30℃ to +60℃ for various industrial environments.

Typische Anwendungen

  1. Motorsteuerung: Frequent start/stop/reverse of 3-phase asynchronous motors (ca. 30kW @ 400V).
  2. Industrielle Automatisierung: Production lines, Förderer, Fans, water pumps and general machinery.
  3. Gebäudeelektrik: HVAC-Systeme, fire water pumps, elevator auxiliary circuits.
  4. Machine Tools: Spindle control for milling machines, drilling machines and small machining centers.
  5. Stromverteilung: Kombiniert mit thermischen Überlastrelais (NR2 series) for complete motor protection starters.
  6. Ergänzende Hinweise
  7. Product Upgrade: The NXC KunLun series fully replaces the traditional CJX2 series with improved mechanical structure, electromagnetic performance and expandability.
  8. Auswahlrichtlinien:

Select current rating according to motor power (65A matches approx. 30kW motor).

Confirm coil voltage (220V / 380V most common).

Expand auxiliary contacts via AX series modules if signal points are insufficient.

  1. Wartungstipps:

Regularly check contact wear; replace contacts when excessive contact resistance occurs.

Keep the contactor clean from dust and moisture.

Apply periodic energization (1–2 times monthly) for long-term idle equipment to prevent coil dampness.

CHINT Contactor Full Series List

  1. Product Series Overview
SeriePositionierungAktueller BereichMerkmaleReplacement Relation
NXCKunLun Main Series6A ~ 630AKompakt, modular, high cost-performanceFull replacement for CJX2
NC5High-performance Intelligent Series9A ~ 630ASmart control, energy-saving, high stabilityHigh-end alternative to NXC
CJX2Classic Traditional Series9A ~ 95AMature model, kostengünstigGradually phased out by NXC
NXCFSlim Compact Series9A ~ 32AUltra-thin, platzsparendSmall cabinet & compact installation
NC8Heavy-duty Industrial Series9A ~ 500AHigh mechanical life, strong arc resistanceFrequent start-stop working conditions
NXCCKondensatorschaltschütz16A ~ 100AInrush current suppression, reactive power compensation dedicatedCapacitor bank control
NCH8Household & Building Series16A ~ 63AMiniature size, GebäudeautomationBeleuchtung, HVAC & residential control
CJ40 / CJ20High-power Heavy Series100A ~ 630AHeavy-load design for large motorsHeavy industrial equipment
  1. NXC KunLun Series Main Model List (AC-3 400V)
NennstromStandard ModelReversing ModelStandard Aux. KontaktMatched Motor PowerBestell-Nr.
6ANXC-06M1NO+1NC0.75kW710010100000276
9ANXC-09NXC-09/N1NO+1NC1.5kW710010100000277
12ANXC-12NXC-12/N1NO+1NC2.2kW710010100000278
18ANXC-18NXC-18/N1NO+1NC3kW710010100000279
25ANXC-25NXC-25/N1NO+1NC5.5kW710010100000280
32ANXC-32NXC-32/N1NO+1NC7.5kW710010100000281
40ANXC-40NXC-40/N1NO+1NC11kW710010100000282
50ANXC-50NXC-50/N1NO+1NC15kW710010100000283
65ANXC-65NXC-65/N1NO+1NC30kW710010100000284
80ANXC-80NXC-80/N1NO+1NC37kW710010100000285
95ANXC-95NXC-95/N1NO+1NC45kW710010100000286
100ANXC-100NXC-100/N2NO+2NC55kW710010100000287
120ANXC-120NXC-120/N2NO+2NC75kW710010100000288
160ANXC-160NXC-160/N2NO+2NC90kW710010100000289
200ANXC-200NXC-200/N2NO+2NC110kW710010100000290
250ANXC-250NXC-250/N2NO+2NC132kW710010100000291
315ANXC-315NXC-315/N2NO+2NC160kW710010100000292
400ANXC-400NXC-400/N2NO+2NC200kW710010100000293
500ANXC-500NXC-500/N2NO+2NC250kW710010100000294
630ANXC-630ANXC-630A/N2NO+2NC315kW710010100000295
  1. NC5 High-performance Series

Model Rule

NC5-[Aktuell][Typ][Spulenspannung]

– Typ: Standard / E=Economy / NE=Intelligent / F=Reversing

Aktueller BereichStandardIntelligentReversingAux. KontaktIsolationsspannung
9A~38ANC5-09~38NC5NE-09~38NC5F-09~381NO+1NC690V
40A~100ANC5-40~100NC5NE-40~100NC5F-40~1001NO+1NC690V
115A~250ANC5-115~250NC5NE-115~250NC5F-115~2502NO+2NC1000V
315A~630ANC5-315~630NC5NE-315~630NC5F-315~6302NO+2NC1000V
  1. Classic CJX2 Series
AktuellModellAux. KontaktMatched Motor
9ACJX2-0910 / 0901 / 09111NEIN / 1NC / 1NO+1NC1.5kW
12ACJX2-1210 / 1201 / 12111NEIN / 1NC / 1NO+1NC2.2kW
18ACJX2-1810 / 1801 / 18111NEIN / 1NC / 1NO+1NC3kW
25ACJX2-2510 / 2501 / 25111NEIN / 1NC / 1NO+1NC5.5kW
32ACJX2-3210 / 3201 / 32111NEIN / 1NC / 1NO+1NC7.5kW
40ACJX2-4010 / 4001 / 40111NEIN / 1NC / 1NO+1NC11kW
50ACJX2-5010 / 5001 / 50111NEIN / 1NC / 1NO+1NC15kW
65ACJX2-6510 / 6501 / 65111NEIN / 1NC / 1NO+1NC30kW
80ACJX2-8010 / 8001 / 80111NEIN / 1NC / 1NO+1NC37kW
95ACJX2-9510 / 9501 / 95111NEIN / 1NC / 1NO+1NC45kW
  1. Other Special Series

NXCF Slim Series

AktuellModellBreiteAux. Kontakt
9ANXCF-0922.5mm1NO+1NC
12ANXCF-1222.5mm1NO+1NC
16ANXCF-1622.5mm1NO+1NC
25ANXCF-2536mm1NO+1NC
32ANXCF-3236mm1NO+1NC

NC8 Heavy-duty Series

AktuellModellPolenMechanisches Leben
9A~38ANC8-09~383P10 million cycles
40A~100ANC8-40~1003P10 million cycles
115A~500ANC8-115~5003P/4P8 million cycles

NXCC Capacitor Contactor

AktuellModellSuppression TypeCapacitor Rating
16ANXCC-16Series resistor10kvar
25ANXCC-25Series resistor15kvar
32ANXCC-32Series resistor20kvar
40ANXCC-40Series resistor25kvar
50ANXCC-50Series resistor30kvar
63ANXCC-63Series resistor40kvar
80ANXCC-80Series resistor50kvar
100ANXCC-100Series resistor60kvar

NCH8 Building / Household Contactor

ModellPolenAktuellAnwendung
NCH8-16M2P16ASmart home control
NCH8-25M2P25AAir conditioning control
NCH8-32M2P32ASmall water pump
NCH8-40M2P40AFloor heating system
NCH8-63M2P63ABuilding lighting
  1. Universal Accessories
ZubehörModellApplicable Series
Auxiliary Contact BlockAX-3M SeriesNXC / NC5 / CJX2
Time Delay ModuleF5 SeriesFull series
Coil Surge SuppressorSR2 SeriesFull series
Mechanische VerriegelungNXC-IL / NC5-ILReversing contactor
Thermisches ÜberlastrelaisNR2 / NR5 SeriesMotor protection combination
35mm DIN-SchieneStandardtypFull cabinet-mounted contactors
  1. Auswahl & Replacement Guide
  2. Series Selection

New project: Adopt NXC KunLun series as priority.

Intelligent control: Choose NC5NE intelligent contactor.

Compact cabinet: Use ultra-thin NXCF.

Reactive power compensation: Special NXCC capacitor contactor.

  1. Aktuelle Auswahl

Rated current ≥ motor rated current × 1.1 (normal duty).

Frequent operation ≥ motor current × 1.25.

  1. Spulenspannung

Match control circuit voltage: AC220V / AC380V most common; safety low-voltage 24V/36V optional.

  1. Hilfskontakte

Expandable via external auxiliary blocks when signal points are insufficient.

Reversing circuit must adopt mechanical interlock type.