E-T-A 3600-P10-Si-8A Thermal-Magnetic Circuit-Breaker - Schütz,Leistungsschalter,Solarwechselrichter,Sensor,Encoder,SPS

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

 E-T-A 3600-P10-Si-8A Thermal-Magnetic Circuit-Breaker - Schütz,Leistungsschalter,Solarwechselrichter,Sensor,Encoder,SPS

elektrisch/Leistungsschalter/

E-T-A 3600-P10-Si-8A Thermal-Magnetic Circuit-Breaker

E-T-A (Eaton Acquired Brand) 3600-P10-Si-8A Thermal-Magnetic Circuit-Breaker for Equipment (CBE) Notiz: E-T-A is not an original Eaton brand; it is a German over-current-protection brand acquired by Eaton. CBE stands for Circuit-Breaker for Equipment. Model Decoding 3600-P10-Si-8A 3600: 3600 Serie, single-pole thermal-magnetic equipment circuit-breaker P10: Push-button reset, P-housing; 10 = M-type tripping characteristic (thermal overload delay ...

  • Produktdetails

E-T-A (Eaton Acquired Brand) 3600-P10-Si-8A Thermal-Magnetic Circuit-Breaker for Equipment (CBE)

Notiz: E-T-A is not an original Eaton brand; it is a German over-current-protection brand acquired by Eaton. CBE stands for Circuit-Breaker for Equipment.

Modelldekodierung

3600-P10-Si-8A

3600: 3600 Serie, single-pole thermal-magnetic equipment circuit-breaker

P10: Push-button reset, P-housing; 10 = M-type tripping characteristic (thermal overload delay + electromagnetic short-circuit instantaneous trip)

Si: 6.3×0.8 mm blade terminals, supports socket plug-in / panel snap-in mounting, with unprotected shunt tap terminal, keine Hilfskontakte (suffix Sia denotes auxiliary contacts fitted)

8A: Rated current In=8 A

Grundlegende elektrische Spezifikationen

ArtikelParameter
Polen1-Pole
AuslösemodusThermisch-magnetisch (delayed thermal overload + instantaneous electromagnetic short‑circuit)
Nenn-Wechselspannung250 VAC
Rated DC Voltage65 VDC
Unterbrechungskapazität1000 A
Terminals6.3×0.8 mm quick‑connect blade terminals
ZurücksetzenManual push‑button reset (Trip‑free mechanism)
MontagePanel snap‑in mounting / plug‑in with dedicated socket bases (17‑P10‑Si / 23‑P10‑Si)
Breite11.5 mm
ZertifizierungenUL, VDE, IEC/EN60934, CSA, CE, RoHS
Front‑face Ingress ProtectionIP40

Typische Anwendungen

Industrielle Steuerungsausrüstung, Eisenbahn & Transit, instrumentation, communication power supplies, 24-48 VDC circuit protection. It serves as a direct replacement for fuses; manual reset is available upon fault tripping with no fuse replacement required.

Bestellinformationen

Full order-part-number: 3600-P10-SI-020148-8A (industry-standard complete ordering code).

Available current ratings within series: 0.5 A / 1 A / 2 A / 4 A / 6 A / 8 A / 10 A / 16 A.

Suffix Sia: with auxiliary alarm contacts; Si: keine Hilfskontakte.

Compatible Socket Bases

Socket bases: 17-P10-Si, 23-P10-Si, 63-P10-Si

Panelmontage: install via ETA original metal mounting clips for cut-out panel assembly.

Ersatz & Alternative Auswahl

  1. OEM same-series alternative: 3600-P10-Sia-8A (for applications requiring auxiliary alarm contacts).
  2. Domestic compatible alternative prerequisites: 8 A rated current, M-type thermal-magnetic characteristic, 65 VDC / 250 VAC rating, 11.5 mm Breite, push-button reset, blade-terminal interface.

Erinnerungen: This device is an equipment-specific circuit-breaker, not a distribution-type MCB miniature circuit-breaker. Its tripping curve differs from domestic-use MCBs; direct interchange is prohibited.

Vergleich: E-T-A 3600-P10-Si-8A vs. Third-Party 1-Pole Thermal-Magnetic CBEs

Governing standard: EN 60934 (Circuit-Breakers for Equipment, CBE). Not compatible with DIN-rail-mounted MCB miniature circuit-breakers per EN 60898; direct swap-out is forbidden.

Key specs for 3600-P10-Si-8A: 11.5 mm Breite, 6.3×0.8 mm blade terminals, manual push-button reset, M-type thermal-magnetic trip, 250 VAC / 65 VDC, 1000 A interrupt rating, keine Hilfskontakte, panel snap-in or socket-plug-in installation.

  1. Comparison with European-brand Thermal-Magnetic CBEs (Phoenix Contact, Weidmüller, Schurter)
VergleichsartikelETA 3600‑P10‑Si‑8APhoenix Contact Thermal‑Magnetic CBE (CB TM1 series)Weidmüller Thermal‑Magnetic Equipment Circuit‑BreakerSchurter Thermal‑Magnetic CBE
MontageartBlade plug‑in, panel snap‑in / dedicated socket base; NOT DIN‑railPrimarily DIN‑rail mount; limited plug‑in variantsPrimarily DIN‑rail mountPlug-in / Leiterplatte / DIN‑rail multi‑form‑factor
Beendigung6.3×0.8 mm blade terminals for direct socket matingSchrauben / spring‑cage terminalsSpring‑cage terminalsQuick‑disconnect blades, solder pins
AuslösecharakteristikM‑type equipment‑protection curve; magnetic instantaneous trip ≈8‑12×InM‑type CBE curveM‑type CBE curveM‑type CBE curve
DC Voltage Rating65 VDC (UL rating 80 VDC)65 VDC60‑65 VDCUp to 80 VDC
Unterbrechungskapazität1000 A1500 A1000‑1500 A1500 A
Reset ActuatorFront‑panel push‑button reset (Trip‑free mechanism)Rocker‑switch resetRocker‑switch resetPush‑button / rocker optional
HilfskontakteNone for Si version; Sia variant adds alarm auxiliary contactsAuxiliary contacts integrated on selected modelsAuxiliary contacts as optionAuxiliary contacts as option
Device Width11.5 mm compact footprint12.5 mm12.5 mm12.7 mm
Core Application StrengthRailway transit, instrumentation, Kommunikationsausrüstung; front‑panel embedded equipment‑level protectionDIN‑rail cabinet‑internal circuit protectionControl cabinet system‑level protectionStromversorgung, medizinische Ausrüstung

Critical Distinction: The ETA 3600 is designed for equipment front-panel mounting or socket plug-in, not DIN-rail installation. Most Phoenix / Weidmüller thermal-magnetic CBEs are DIN-rail cabinet-mounted with spring-cage / Schraubklemmen, lacking 6.3 mm blade socket interface; mechanical fit is incompatible, direct replacement is impossible.

  1. Fundamental Differences vs. DIN-Rail MCB Miniature Circuit-Breakers (C / D-Kurve) — Common Pitfall

MCB complies with EN 60898 for power-distribution purposes. ETA 3600 complies with EN 60934 for equipment-protection CBE. Different standards; direct interchange strictly prohibited.

  1. Tripping Curve Difference

ETA 3600-P10-Si: M-type CBE characteristic, optimized for industrial devices, coils and power supplies; tolerates moderate inrush surge current with mild thermal tripping behaviour.

MCB C-curve: instantaneous trip 5-10 × In; D-Kurve: instantaneous trip 10-20 × In, designed for wiring distribution protection. Risk of nuisance tripping or failure-to-trip when protecting electronic equipment.

  1. DC Performance Gap

UND: 65 VDC rating, validated DC arc-extinguishing for 24-48 V industrial DC loops.

Conventional 1-pole MCB: most rated ≤48 VDC; many variants have no DC rating at all. Arc-extinguishing failure risk exists under higher DC voltage.

  1. Unterbrechungskapazität

UND: 1000 A (equipment-protection rating). Standard miniature MCBs advertise 6 kA AC interrupt rating, which applies for AC distribution short-circuit conditions; performance differs substantially for low-voltage DC short-circuit events.

  1. Installation Form Factor

UND: blade-socket / panel-clip mounting, fitted onto equipment chassis front-panel. MCB clamps to DIN-rail inside control cabinets.

  1. Comparison with Domestic Clone-Compatible CBE Products

Domestic drop-in alternatives for 3600-P10-Si replicate: 6.3×0.8 mm blade terminals, 11.5 mm Breite, push-button reset; physically fit original ETA sockets 17-P10-Si / 23-P10-Si.

Major performance gaps:

Tripping consistency: Bimetallic element dispersion for M-curve; significant tripping-point drift across wide temperature range (−40 ~ +85 °C), which is critical for railway-transit deployments.

Trip-free safety mechanism: Some low-cost domestic copies omit this feature; the breaker can be forced closed manually even under fault conditions, a major safety hazard.

Certification coverage: Original carries full VDE/UL/CSA approvals; many domestic alternatives only carry self-declared CE, disqualifying them for export-grade equipment.

Internal contact resistance: Original 3600 series typical resistance 12-18 mΩ; some domestic units exhibit higher resistance and excessive heating under full-load current.

  1. Practical Replacement Prerequisites

All criteria must be satisfied for direct drop-in replacement:

✅ Complies with EN 60934 CBE standard, M-type tripping characteristic

✅ Rated 250 VAC, DC rating ≥65 V

✅ 6.3×0.8 mm blade terminals, 11.5 mm device width

✅ Manual push-button reset + Trip-free mechanism

✅ Interrupting capacity ≥1000 A

❌ DIN-rail MCBs and electronic PTCB circuit-breakers cannot substitute directly. PTCB uses electronic current-limiting, while thermal-magnetic breakers rely on physical bimetallic actuation; fault-response behaviour is fundamentally different.

  1. Select suffix -Sia variant if fault-alarm signalling is required; -Si has no auxiliary contacts.
  2. Low-resistance sibling series: 3900-P10-Si-8A, lower internal resistance for circuits sensitive to voltage drop.
  3. Typical Selection Misconceptions
  4. “Same 8 A rating means interchangeable”: Auslösekurve, DC voltage rating, Trip-free safety mechanism and mechanical mounting interface are all mandatory matching criteria.
  5. Substituting thermal-magnetic CBE with Phoenix PTCB electronic circuit-breaker: PTCB implements electronic current-limiting, not thermal-magnetic actuation; overload response differs, cannot be swapped directly.
  6. Direct substitution with standard C-curve MCB: risk of DC arc-extinguishing failure on 24-48 V DC loops and mismatched equipment-protection tripping thresholds.

E-T-A 3600-P10-Si-8A Application Scenarios

This device is an EN 60934 thermal-magnetic Circuit-Breaker for Equipment (CBE). Its intended use is circuit-protection inside end-equipment, not cabinet-level power-distribution. Key features: panel-clip / socket-plug-in mounting, 250 VAC / 65 VDC rating, M-type thermal-magnetic trip, manual push-button reset. No fuse replacement needed after tripping.

Notiz: -Si variant has no auxiliary alarm contacts. Choose the -Sia suffix model if fault-status output signal is needed.

🔌 DC Circuit Applications (Most Common for 24 V / 48 V Industrial DC)

  1. Internal supply sub-circuits for industrial control hardware

Power feeds for PLC peripherals, IO modules, collective sensor loops, servo auxiliary power supplies, 24 V solenoid-valve banks. The 8 A rating suits clustered banks of sensors and solenoid valves. Replaces fuses, delivers short-circuit & Überlastschutz. On-site push-button reset without chassis disassembly and fuse swap.

  1. Telecom & industrial power hardware

Internal power branches for industrial switches, gateways, DTUs, edge-computing hardware; 48 V telecom equipment for board-card output-circuit protection.

  1. Battery-powered equipment

Secondary-side circuit-protection for lithium-ion / lead-acid battery-operated devices. 65 VDC rating covers nearly all 24-48 V battery-based systems.

🚆 Railway & Transit (ETA Traditional Strength Domain)

On-board equipment boxes, metro vehicle control units, door-control modules, cabin lighting, on-board instrumentation.

Operates over wide temperature range −40 °C ~ +85 °C, high vibration-shock resistance. Front-panel installation allows maintenance-staff reset without cabinet opening.

Railway projects normally specify -Sia auxiliary-contact variant, to report fault events to vehicle control systems.

🧪 Instrumentation & Non-Life-Support Medical Auxiliary Equipment

Test-and-measurement hardware, laboratory analytical instruments, production test fixtures, non-life-support medical auxiliary devices.

Fuse-replacement with resettable protection, reduces spare-part inventory; full UL/VDE certification satisfies equipment safety requirements.

Not recommended for direct deployment on life-critical medical primary circuits without full assessment.

📟 Industrial Chassis & Embedded Equipment

  1. Card-cage chassis hardware: deploy with socket bases 17-P10-Si / 23-P10-Si; breaker plugs into socket for quick hot-swap replacement.
  2. Panel-cutout clip-mount installation: reset push-button protrudes through equipment front-panel for easy operator access.

This is the primary differentiator vs DIN-rail breakers: it mounts to the end-equipment itself, not inside control-cabinet DIN-rail infrastructure.

⚙️ Construction Machinery & Off-Highway Vehicle Electronics

Construction-vehicle / special-vehicle on-board electrical enclosures, portable field-test gear. 24 V vehicle-system operation; M-type characteristic tolerates motor / coil inrush transients without nuisance tripping; high vibration immunity.

❌ Non-Suitable Use-Cases

  1. Inländisch / building power-distribution circuits: Cannot replace MCB miniature breakers; it is equipment-internal protection, not wiring-distribution protection.
  2. DC voltages exceeding 65 V: Maximum DC rating is 65 V; forbidden for 72 V, 110 V DC systems.
  3. Remote electrical-trip requirement: No shunt-trip coil available; only manual push-button reset.
  4. Fault-alarm signal requirement: -Si has no auxiliary contacts; order -Sia instead.

✅ Selection Tips

  1. Circuits containing motors or inductive coils: M-type tripping withstands motor startup surges and prevents nuisance tripping.
  2. Equipment requiring fault-status acquisition: Specify 3600-P10-Sia-8A.
  3. Voltage-drop-sensitive circuits: Upgrade to low-resistance variant 3900-P10-Si-8A.

Vorher:

Nächste:

Hinterlassen Sie eine Antwort

Eine Nachricht hinterlassen