Eaton PKZM0-16 Motor-Protective Circuit Breaker

Bestell-Nr.: 046938 Part of Moeller PKZM0 series; 3-pole rotary-knob motor circuit breaker integrating overload & Kurzschlussschutz, Klasse 10 trip characteristic, with built-in phase-failure protection. ✅ Core Technical Parameters Poles: 3P Adjustable current setting range: 10~16 A Rated operational voltage Ue: Max. Wechselstrom 690 V Matched motor power (AC-3, 50 Hz): 230 V: 4 ...

  • Produktdetails

Bestell-Nr.: 046938

Part of Moeller PKZM0 series; 3-pole rotary-knob Motorschutzschalter integrating overload & Kurzschlussschutz, Klasse 10 trip characteristic, with built-in phase-failure protection.

✅ Core Technical Parameters

Polen: 3P

Adjustable current setting range: 10~16 A

Bemessungsbetriebsspannung Ue: Max. Wechselstrom 690 V

Passende Motorleistung (AC-3, 50 Hz):

230 V: 4 kW

400 V: 7.5 kW

440 V: 9 kW

Instantaneous short-circuit trip current: Behoben bei 248 A

Reiseklasse: Klasse 10

Beendigung: Schraubklemmen

Schutzklasse: IP20 (front touch-safe)

Gesamtabmessungen: W45 mm × H93 mm × D76 mm

Elektrische Ausdauer: 100,000 Operationen

Standards: IEC/EN 60947-4-1, VDE, UL508, CE, CSA-zertifiziert

✅ Hauptmerkmale

  1. Sensitive phase-failure protection; trips rapidly on single phasing to prevent motor burnout.
  2. Rotary knob with padlock provision for lockout/tagout (HERZ) safety isolation.
  3. Built-in TEST pushbutton for manual mechanical trip testing.
  4. Wide range of add-on accessories: Hilfskontakte, fault trip contacts, Unterspannungsauslöser, Rangierfahrt, side busbars.
  5. DIN-Schienenmontage; modularer Aufbau, directly combinable with DILM contactors to form MSC motor starter units.

✅ Variants with Suffixes (Same Current Rating)

PKZM0-16: Standard-Schraubklemmen (Bestell-Nr. 046938)

PKZM0-16-EA: EA export version

PKZM0-16-SPI32: Screw terminals on line side, push-in spring terminals on load side

PKZM0-16-GVP2: Bulk packaging version

✅ Selection & Equivalent Cross Reference

Domestic equivalents: Delixi CDP6-16, Chint NS2-25 (10–16 A)

Next higher rating in series: PKZM0-20 (16~20 A)

Notiz: PKZM0 is an integrated breaker; it cannot be used solely as an overload relay. Use ZB series if only thermal overload protection is required.

✅ Leitfaden zur Fehlerbehebung

  1. Trips immediately with no load: Check if current setting is too low, Phasenverlust, or mechanical trip mechanism jamming.
  2. Instant trip on motor startup: Short-circuit protection triggered; inspect motor winding short-circuit or cable fault.
  3. Slow trip under sustained overload: Normal Class 10 inverse-time behaviour; if tripping frequently under heavy load, increase the current setting or upgrade to a higher-rated model.

Full Accessory List for PKZM0 Series (Applicable to PKZM0-16)

Installationsregel: NHI-E = front-mounted; NHI = side-mounted; AGM = fault trip contact; U-PKZ0 = undervoltage release; A-PKZ0 = shunt trip. Suffix -PI = push-in spring terminals; no suffix = screw terminals.

  1. Standard-Hilfskontakte (Main contact status feedback: closed/open signal)
  2. NHI-E-10-PKZ0|1NO, front-mounted
  3. NHI-E-01-PKZ0|1NC, front-mounted
  4. NHI-E-11-PKZ0|1NO+1NC (am häufigsten), front-mounted
  5. NHI11-PKZ0|1NO+1NC, seitlich montiert
  6. NHI21-PKZ0|2NO+1NC, seitlich montiert
  7. NHI12-PKZ0|1NO+2NC, seitlich montiert

PI version available: NHI-E-11-PKZ0-PI (Federklemmen)

Bewertung: AC-15 230 V 0.5 A, DC-13 24 V; used for PLC feedback and status indication lamps.

  1. Fault Trip Contacts (Only actuated on protective trip – critical distinction!) AGM Series

Only changes state when tripped by overload / Kurzschluss / Phasenverlust; remains inactive during manual ON/OFF operations, used exclusively for fault alarm signals.

  1. AGM2-01-PKZ0|2NC (standard for engineering projects)

PKZM0 Full Model List

1) Standard Screw Terminal Models (Base Version, No Suffix)

ModellAdjustment Range IrPassender Motor (400 V)Eaton Bestell-Nr.
PKZM0-0,160.10~0.16 A0.04 kW72730
PKZM0-0,250.16~0.25 A0.06 kW72731
PKZM0-0,40.25~0.40 A0.09 kW72732
PKZM0-0,630.40~0.63 A0.18 kW72733
PKZM0-10.63~1.00 A0.25 kW72734
PKZM0-1,61.00~1.60 A0.37 kW72735
PKZM0-2,51.60~2.50 A0.55 kW72736
PKZM0-42.50~4.00 A1.1 kW72737
PKZM0-6,34.00~6.30 A2.2 kW72738
PKZM0-106.30~10.0 A4.0 kW46937
PKZM0-128.00~12.0 A5.5 kW278486
PKZM0-1610.0~16.0 A7.5 kW46938
PKZM0-2016.0~20.0 A9.0 kW46988
PKZM0-2520.0~25.0 A11 kW46989
PKZM0-3225.0~32.0 A15 kW278489

Suffixdefinition (Gleiche aktuelle Bewertung, only terminal/function differs)

  1. -PI: Push-in spring terminals (Werkzeuglose Verkabelung); Beispiel: PKZM0-16-PI
  2. -C: Older spring clamp version (same function as PI)
  3. -EA: Export overseas standard model (identical construction to domestic standard version)
  4. -T: Transformer protection variant (NO phase-failure protection, only thermal + short-circuit trip); Beispiel: PKZM0-0,63-T
  5. /UND: Thumb-lock rotary handle, field padlockable
  6. -SPI32: Mixed terminals: line-side screw, load-side push-in

2) PKZM01 Compact Series (Kipphebel, NO phase-failure protection; only overload + short-circuit trip)

Notiz: PKZM01 has no phase-loss protection; only for small motors without single-phasing risk.

ModellAdjustment Current Range
PKZM01-0.40.25~0.4 A
PKZM01-0.630.4~0.63 A
PKZM01-10.63~1 A
PKZM01-1.61~1.6 A
PKZM01-2.51.6~2.5 A
PKZM01-42.5~4 A
PKZM01-6.34~6.3 A
PKZM01-106.3~10 A
PKZM01-128~12 A
PKZM01-1610~16 A
PKZM01-2016~20 A
PKZM01-2520~25 A

3) Higher-Current PKZM4 Series (16~63 A, fully interchangeable accessories with PKZM0)

PKZM4-16 / PKZM4-20 / PKZM4-25 / PKZM4-32 / PKZM4-40 / PKZM4-50 / PKZM4-63

4) Modellbenennungsregel (Quick Selection)

PKZM0 16 PI

  1. PKZM0 = Motor-protective circuit breaker (with phase-failure protection, Drehgriff)
  2. Numeric value = Maximum adjustable current (16 = 10~16 A)
  3. Suffix = Terminal type / special function

5) Standardzubehörliste (Fits all PKZM0 variants)

1) Hilfskontakte (Positionsrückmeldung)

NHI-E-11-PKZ0 (Front-mounted: 1NO+1NC)

NHI11-PKZ0 (Seitlich montiert: 1NO+1NC)

2) Fault Trip Contacts (Only triggered by overload/phase loss/short-circuit)

AGM2-01-PKZ0 (2NC, standard for site engineering)

3) Voltage Releases (Only one can be fitted at a time, not both together)

U-PKZ0 Undervoltage release (24VDC / 110V / 230V / 400V)

A-PKZ0 Shunt trip release (24VDC / 110V / 230V / 400V)

4) Mechanical Accessories

PKZ0-XRH: Extended rotary handle for cabinet door mounting (padlockable)

CL-PKZ0: Phase barrier

B-PKZ0: Parallel busbar for multiple units

6) Auswahlrichtlinien

  1. Require phase-failure protection → Choose PKZM0; No phase-loss risk & cost-sensitive → Choose PKZM01.
  2. Remote tripping → Select A-PKZ0 shunt trip; Anti-restart on power failure → Select U-PKZ0 undervoltage release (cannot mount both).
  3. Frequent on-site wiring → Prefer -PI push-in terminal version; General installation → Standard screw terminal model.