Positionierung: 23.1-inch IMO-compliant marine radar dedicated display unit (CR = Radar version). It is the matching display for FAR-28X7 radar and is now End of Life (EOL).
Unterscheidung: MU-231 is a universal multi-input marine display; MU-231CR is a radar-customized version with interfaces and firmware specially adapted for FURUNO black-box radar systems. It is NOT a general-purpose monitor.
Wichtige Spezifikationen
Bildschirm: 23.1″ color LCD, UXGA 1600 × 1200
Brightness: 400 cd/m², built-in light sensor for automatic dimming
Contrast Ratio: 600:1
Signaleingang: Single dedicated DVI-D radar port, no RGB / composite video input, PIP (Picture-in-Picture) nicht unterstützt (main difference from MU-231)
Stromversorgung: 100–230 VAC, single-phase 50/60Hz (Nur Wechselstrom)
Zertifizierung: IMO Wheel Mark, compliant with marine radar regulations for seagoing vessels
Power-on Logic: Auto power on/off triggered by DVI signal; no physical control buttons on the unit itself
Montage: Unterputzmontage / cantilever bracket mount (bracket sold separately)
Gewicht: 16.6 kg (Panelmontage); 23.5 kg (bracket mount)
Compatible Radar Systems
✅ FAR-2807 / FAR-2817 / FAR-2827 (FAR-28X7 series, paired with RPU-013 radar processor)
✅ FAR-2107, FAR-2127 (black-box radar with dedicated DVI-D radar video output)
⚠️ Wichtige Einschränkung: Cannot connect directly to standard PC DVI outputs. It only recognizes proprietary radar DVI video signals from FURUNO radar processors.
System Components for Complete FAR28X7 Radar
MU-231CR: Radar display unit
RPU-013: Radar processor unit
RCU-014: Full keyboard control unit / RCU-015: Trackball control unit / RCU-016: Remote control unit
XN-12AF / XN-20AF / XN-24AF: Radar antenna units
Ersatz & Spare Part Information
- Original new units are no longer available on the market; supplies are mainly used pull-outs and refurbished units.
- Replacement options: New-generation FURUNO radar displays (processor protocol and panel cutout dimensions must be evaluated together).
- Häufige Fehlerquellen: Backlight board, DVI interface board, power supply board, ambient light sensor assembly.
- Document Part Number: OMC-44690 (shares base manual with MU-231; separate schematic drawings apply for CR variant).
Vergleichstabelle: MU-231CR vs MU-231
| Artikel | MU-231CR (Radar Version) | MU-231 (Universal Marine Version) |
| Eingang | Dedicated radar-only DVI-D port only | Dual DVI + RGB + composite video |
| PIP Picture-in-Picture | ❌ Nicht unterstützt | ✅ Unterstützt |
| Anwendung | Exclusive for FAR-series radar | Radar, ECDIS, echo sounder, sonar, camera multi-source switching |
| Auto Power Control | DVI signal triggered | DVI signal triggered |
FURUNO MU-231CR Supporting Manual List
Wichtiger Hinweis: FURUNO does not release a standalone manual for MU-231CR. The MU-231CR is a dedicated display bundled with FAR-28X7 radar systems. The base hardware documentation is shared with MU-231. CR-specific differences, radar linkage logic and proprietary DVI protocol details are documented within the FAR-28X7 radar system manuals.
- Main Display Operation Manual (Obligatorisch, OMC-44690)
Title: MU-231 Operator’s Manual
Document No.: OMC-44690, Revision D2 (latest revision)
Inhalt: Installation cutout dimensions, Verdrahtung, Stromversorgung, auto brightness adjustment, menu configuration, basic maintenance, outline drawings, Terminaldefinitionen, basic troubleshooting
Anwendbar: MU-231 / MU-231CR (CR variant only differs in firmware and input lockout; mechanisch, power and hardware circuits are identical)
Sprache: Bilingual English + japanisch
Einschränkung: This manual does not cover proprietary radar DVI protocol or RPU-013 interworking logic, only the display hardware itself.
- Quick Reference Guide (for on-site commissioning)
Title: MU-190 / MU-231 Operator’s Guide
Compact quick-start booklet for vessel crews and field technicians: brightness adjustment, auto dimming, access to installation menu, menu unlock
No schematics or spare part BOM; for daily onboard operation only.
- Radar System Master Manual (Core Reference for MU-231CR, Highly Recommended)
The MU-231CR cannot operate independently without the FAR-28X7 radar processor. Radar linkage, signal timing, power-up sequence and RCU control integration are all covered in this set of documents
- FAR-2807 / FAR-2817 / FAR-2827 Operator’s Manual (Radar Operation Manual)
For RPU-013 processor, covers radar video output to MU-231CR, trackball/keyboard control, ARPA target tracking
- FAR-28X7 Installation & Service Manual
Contains complete system interconnection wiring diagrams, RPU-013 ↔ MU-231CR dedicated DVI link description, fault isolation, spare parts list and system commissioning procedures
- Supplementary control unit manuals: RCU-014 / RCU-015 / RCU-016 Operator Manuals
- Service-Level Manuals (Reparatur auf Platinenebene, for agents & service workshops)
MU-231 Service Manual: Schematics, Leistungsplatine / backlight board / driver board disassembly, voltage test points, spare part BOM
⚠️ This document is not available for public download; access restricted to FURUNO authorized service channels, public resources are scarce.
- Multilingual Versions (Optional)
MU-190/MU-231 French Quick Guide, Spanish Quick Guide (for foreign vessel crews)
Reading Priority Recommendation
✅ On-site installation & Verdrahtung: OMC-44690 (MU-231 Operator Manual) + FAR-28X7 Installation Manual
✅ Daily radar operation by crew: FAR-28X7 Radar Operator Manual (Do not rely only on the display manual; the CR model has no independent radar picture menus)
✅ Board replacement & schwarzer Bildschirm / no radar signal troubleshooting: FAR-28X7 Service Manual + MU-231 Service Manual
Common Pitfall Reminders
- Do not commission MU-231CR using only the MU-231 universal manual: universal MU-231 supports multi-DVI and PIP, while MU-231CR firmware disables these functions. CR-specific notes inside the FAR radar manual must be referenced.
- Searching “MU-231CR manual” online will almost never return standalone documents. Industry standard practice: use OMC-44690 together with FAR28X7 system manuals.
FURUNO MU-231CR Black Screen / No Radar Image Troubleshooting Checklist
Voraussetzung: MU-231CR is a dedicated radar display and only accepts proprietary DVI signals from RPU-013 radar processors. Troubleshooting logic differs from standard monitors. Three symptom categories: [Complete black screen, Betriebsanzeige aus], [Power indicator ON but screen black / backlight on, no radar picture], [Backlight ON, schwarzer Bildschirm, No Signal prompt]
- Initial Status Verification (Onboard Priority Checks)
- Verify power supply for the whole system: MU-231CR runs on AC 100–230V. Leistungsschalter prüfen, internal fuses, shipboard voltage, Phasenverlust, voltage drop and transient power loss.
- Confirm matched equipment: This display must work with RPU-013 radar processor. Antenna unit and RCU control unit also need power supply.
- Observe front indicator lamp:
Power lamp OFF: Fault in power circuit or display power supply board
Power lamp steady ON, no picture: Fault in signal link, RPU processor, dedicated DVI cable or backlight/driver board
- Follow regulated power-up sequence: Power on RPU-013 radar processor first, then MU-231CR. MU-231CR wakes up only upon valid radar DVI signal; standalone power-up will result in black screen (not a hardware fault).
Häufiges Missverständnis: Powering MU-231CR alone without RPU signal output → black screen, this is normal behaviour.
- Symptom A: Fully Black Screen, Power Indicator OFF
- Measure AC input voltage at the socket to confirm within rated range.
- Check internal input fuse on display power board. Replace with same specification if blown. Never use a higher-rated fuse.
- Disconnect DVI cable and power the display separately to check whether downstream short circuit pulls down power rail.
- If input voltage is normal and fuse intact but lamp remains off: fault points to MU-231CR power supply board.
- Measure power board output rails against service manual: 24V, 5V and backlight supply.
- Symptom B: Power Lamp ON, No Backlight (Screen Completely Dark)
- Open cover slightly and listen for faint high-frequency hum from backlight inverter; no hum = backlight circuit failure.
- Troubleshoot: backlight inverter / backlight panel, backlight power harness, loose LVDS screen cable.
- Distinguish LCD panel damage vs backlight driver failure.
- Quick test: Shine a flashlight obliquely onto the screen. Faint radar menu characters visible → backlight failure; nothing visible → signal / Mainboardfehler.
- Symptom C: Backlight ON, Black Screen, “No Signal” Prompt (Am häufigsten)
Kritisch: MU-231CR runs dedicated firmware, standard PC DVI signals are rejected and trigger No Signal.
- Check RPU-013 radar processor status: Power and RUN indicators, active fault codes.
- Reboot sequence: Full power cut for 3 Minuten (Kondensatorentladung) → power RPU-013, wait 2–3 minutes for full self-test completion → then power MU-231CR.
- Inspect dedicated DVI cable: This is FURUNO radar-specific DVI cable; standard DVI cables are not compatible. Gebogen, oxidized or loose pins at connectors are frequent failure points.
- Re-seat DVI connectors at both ends: RPU-013 rear DVI port ↔ MU-231CR DVI input port, clean pin contacts.
- Cross-test if spare parts available:
Swap with a confirmed good original radar DVI cable
Wenn möglich, connect MU-231CR to a known working RPU-013 from another FAR-28X7 system to isolate failure between display and processor
- Inspect RPU-013 internals: RPU mainboard, video output board; faulty RPU will not transmit proprietary radar DVI stream.
- Notiz: Faulty RCU control box will not cause black screen / no image, only loss of radar control.
- Symptom D: Backlight ON, Screen Black, No “No Signal” Pop-up
- Loose LVDS/eDP screen cable: Power off and re-seat harness between screen driver board and LCD panel.
- Display main signal board failure: Receives DVI clock but cannot decode FURUNO proprietary radar video.
- Firmware-Beschädigung: CR firmware is locked in radar-only mode. Corrupted firmware can only be reflashed by FURUNO service; field reflashing is not possible.
- Umweltfreundlich & Interference Checks (Often Overlooked Onboard)
- Ship power harmonic distortion / inverter noise: If radar shares supply with heavy loads (Kräne, große Motoren), temporarily connect to isolated clean power supply for testing.
- Erdung: RPU, display and antenna protective earth must connect reliably to ship ground. Poor grounding causes intermittent video dropout and black screen.
- Temperatur: Overheat inside cabinet triggers thermal protection on power board and DVI chipset; function resumes after cooling. Recurring issue indicates poor ventilation.
- Isolation Logic for Rapid Fault Localization
Normale Leistung + RPU self-test OK + good dedicated DVI cable → Fault inside MU-231CR (Leistungsplatine / backlight board / main control board / LCD panel)
Normale Leistung + replacement good MU-231CR still shows no signal → Fault in RPU-013 radar processor or antenna link
Intermittent black screen, recovered after tapping connector → DVI cable or contact pin failure
- Repair Prohibitions & Sicherheitshinweise
- Never substitute MU-231CR with a standard commercial DVI monitor; protocol incompatibility means no radar picture.
- Do not flash universal MU-231 firmware onto MU-231CR; radar-specific functions will be lost and the unit bricked.
- Always cut power before opening enclosure; power board capacitors hold high residual voltage, allow sufficient discharge time.
- Ersatzteilbeschaffung: Complete pull-out kits (RPU + DVI cable + MU-231CR) werden bevorzugt; individual boards are scarce in supply.
- Post-repair commissioning: Re-integrate with FAR-28X7 radar; verify radar range scales and ARPA output parameters.
- Quick Fault Reference Table
| Symptom | Highest Probable Failure Point |
| Lamp off, no unit response | Input power supply, interne Sicherung, power supply board |
| Lamp on, faint menu visible with flashlight | Backlight panel / backlight inverter |
| Lamp on, backlight on, No Signal message | RPU not ready, dedicated DVI cable damaged, RPU video output board |
| Intermittent black screen, recovers with vibration | DVI connector or loose screen cable |
| Black screen when cold, works after warming up | Ageing electrolytic capacitors on power board |
FURUNO MU-231CR Supporting Equipment Status Check (RPU-013, XN-12AF/20AF/24AF Antenna, RCU-014/015/016)
Systemkette: Antenna Unit → RPU-013 Radar Processor → Dedicated DVI Cable → MU-231CR. RCU is only for control and does not generate radar video.
Grundprinzip: MU-231CR itself does not generate radar signals. Radar image presence ultimately depends on whether RPU-013 outputs valid proprietary radar DVI video stream.
- RPU-013 Radar Processor (Höchste Priorität)
1.1 Front Panel Indicator Interpretation
POWER LED: Steady green = Input power normal; OFF → Check RPU supply, internal fuse and power module.
RUN-LED: Steady green after self-test completion = Normal operation;
Blinkt: Self-test in progress, firmware loading or active fault alarm
Rot konstant / blinkt: Fehlfunktion, read fault code
ALARM LED: Red illuminated = active fault (antenna communication, transceiver, Übertemperatur, video output, Lüfter, ADC fault etc.)
✅ Normal healthy state: POWER steady green + RUN steady green + ALARM off. Allow 2–3 minutes post power-up for self-test before radar DVI output activates.
1.2 Two Methods to Retrieve RPU Fault Codes
- Methode A (MU-231CR can display, only missing radar echo): Enter radar menu →【Alarm / Fault Log】to review fault history
- Methode B (MU-231CR no signal / schwarzer Bildschirm): Read 7-segment display or status LEDs on RPU mainboard, cross-reference FAR-28X7 service manual for fault definitions
Common alarm categories: antenna communication error, transceiver fault, over-temperature, Lüfterausfall, DVI video output fault, ADC fault.
1.3 Verify RPU DVI Radar Output (Field Test)
Notiz: Standard PC DVI monitor cannot decode this proprietary signal.
Zustand 1: Confirmed good MU-231CR spare unit: swap in spare display. If spare shows radar picture → original MU-231CR faulty; spare still No Signal → RPU no video output.
Zustand 2: Oszilloskop (professional service): Measure DVI differential clock and data waveform at RPU port. Clock present but no valid image data → RPU internal video board failure.
Zustand 3: RPU internal fan observation: Fan should rotate smoothly after power-up. Stopped fan triggers over-temperature protection and cuts video output.
1.4 RPU Power Supply Check
RPU supply is typically AC100–230V. Klemmenspannung messen, check loose terminals, voltage drop and ship power harmonic noise.
RPU has separate internal fuse. Never short-circuit blown fuse; investigate downstream short circuit (antenna coaxial cable or transceiver assembly).
- XN-12AF / XN-20AF / XN-24AF Antenna Unit (Antenna + Transceiver)
Antenna faults fall into two categories: Antenna not rotating, Antenna rotates but no echo / communication loss
2.1 Mechanical Rotation Check
After RPU self-test completes, antenna should rotate at constant smooth speed (nominal ~24 rpm).
No rotation at all: Motor power supply, slip ring, drive circuit or RPU antenna communication fault.
Kleben, ungewöhnliches Geräusch, intermittent rotation: Bearing seizure, slip ring oxidation and wear, motor failure.
⚠️ Sicherheitswarnung: Rotating radar antenna presents mechanical hazard; do not approach. X-band radar transmits RF energy; avoid standing close and facing antenna front during transmission.
2.2 Kommunikation & RF Status
Antenna to RPU link: RF coaxial cable + multi-core control cable (slip ring harness).
RPU reports【Antenna Comm Error】: Control wire, slip ring and connector oxidation / open circuit are top causes.
Antenna rotates but no echo: Magnetron, transceiver module or modulator failure; magnetron degradation is a common consumable failure.
Basic judgement: Smooth rotation + no antenna communication alarm on RPU ≠ RF transmission is healthy. Communication link OK only; RF output power needs verification with RF power meter.
2.3 Antenna Temperature & Waterproof Inspection
Water ingress and condensation inside antenna housing cause RF short and slip ring corrosion. Check drain holes are clear. High internal temperature triggers antenna over-temperature protection and RPU transmission shutdown.
- RCU Control Unit: RCU-014 / RCU-015 / RCU-016 (Tastatur / Trackball)
Kritisch: RCU failure will NOT cause black screen or missing radar image!
RCU is human-machine interface only, communicating with RPU over RS485 / proprietary serial bus. It does not carry radar video.
✅ Normal status indicators:
- RCU power indicator illuminates
- When MU-231CR displays radar picture, keys and trackball operate radar menu, change range scale and adjust gain.
❌ Fault symptoms: Picture normal, but keys unresponsive, trackball drift, menu cannot be controlled.
Fehlerbehebung: RCU power, serial communication cable, Abschlusswiderstand, address setting. Multiple parallel RCU units with conflicting addresses will cause loss of control.
- Cable Link Inspection (Frequently Overlooked)
- RPU ↔ MU-231CR dedicated DVI cable: FURUNO custom radar cable; pin definition and timing differ from standard DVI. Visual check for bent pins, oxidation and jacket damage. Vibration test to reproduce intermittent dropout.
- RPU ↔ Antenna: Steuerkabel + RF coaxial: Water ingress and poor contact at coaxial connectors cause echo loss and antenna alarms. Perform VSWR standing wave ratio test; excessive VSWR indicates RF link fault.
- RPU ↔ RCU communication cable: Geschirmtes Twisted-Pair, Schirm einseitig geerdet; incorrect grounding causes unstable communication.
- Standard Fast Diagnostic Workflow (Field Engineer Sequence)
- Full power cut for all equipment, rest 3 Minuten für die Kondensatorentladung.
- Power sequence: Antenna unit → RPU-013. Wait 2–3 minutes for self-test completion, confirm RUN steady green, ALARM off and antenna starts rotation.
- Power MU-231CR and observe screen behaviour.
- Cross-test with spare MU-231CR to separate faults between【RPU no video output】and【display hardware failure】.
- If RPU persistently raises antenna alarm: Inspect antenna control wiring, slip ring and coaxial cable, antenna motor.
- Radar picture present but no control: Troubleshoot RCU communication circuit separately.
- Key Summary Table
| Komponente | Failure can cause black screen / no radar image | Typical Healthy Status |
| RPU-013 | ✅ Ja (Highest frequency) | POWER green, RUN steady green, ALARM off, fan running, proprietary radar DVI output active |
| XN Antenna Unit | ✅ Ja (No echo, RPU alarm may cut video) | Smooth constant rotation, no antenna communication alarm on RPU |
| Dedicated DVI Cable | ✅ Ja | Connector intact, no bent pins, picture restored after swapping known good cable |
| RCU Control Unit | ❌ Nein | Indicator lit; keys and trackball operate radar menu when picture is present |
- Supplementary Reminders
- Do not measure DVI differential signals with a multimeter; risk of burning driver chip. Cross-replacement test is preferred for qualitative diagnosis.
- Many RPU faults are intermittent: works cold, drops signal under navigation vibration. Focus inspection on slip ring, coaxial connectors and DVI interfaces.
- RF power and VSWR are metrology-grade tests requiring marine RF power meter / SWR bridge; standard multimeter cannot verify RF performance.
FURUNO MU Series Marine Radar Dedicated Display Unit List
Key Classification Rule:
MU-xxxCR = Radar-locked dedicated version (only accepts proprietary DVI signals from matched black-box radar RPU, no PIP, incompatible with standard PC / ECDIS multi-source inputs)
MU-xxx (without CR suffix) = Universal marine display, supports radar, ECDIS, echo sounder, camera inputs and PIP picture-in-picture
All models carry IMO Wheel Mark certification, designed for FAR-28X7 / FAR-21X7 / FAR-15X3 black-box radar systems. CR variants are factory-bundled with radar sets and not sold as standalone original spare units, circulated in used/refurbished spare markets.
Integrated radar (FR series, FAR all-in-one units with built-in screen) are excluded; these are not independent MU display units.
- Radar-Locked Dedicated CR Models (Primary Category for Your Application)
| Modell | Bildschirmgröße | Auflösung | Matched Radar Processor | Notizen | Lebenszyklusstatus |
| MU-231CR | 23.1″ | UXGA 1600×1200 | RPU-013 (FAR-2807/2817/2827, FAR-2107/2127) | Single dedicated radar DVI only, no PIP, no composite / RGB input, auto light sensor | EOL, used/refurbished spare only |
| MU-201CR | 20.1″ | SXGA 1280×1024 | RPU-011 / Early FAR21XX black-box radar | Older 20-inch radar dedicated display, proprietary DVI interface | EOL, very limited stock |
| MU-190CR | 19″ | SXGA 1280×1024 | RPU-024 / FAR-1513-BB / FAR-1523-BB | 19-inch radar dedicated variant, multi-input locked by firmware | EOL, common on fishing / inland vessels |
| MU-170CR | 17″ | SXGA 1280×1024 | Early low-power black-box radar | Older 17-inch model, extremely scarce supply | EOL |
| MU-151CR | 15″ | XGA 1024×768 | Small fishing vessel black-box radar | Early compact radar dedicated display | EOL |
Ergänzen: CR variants share identical mainboard hardware with same-number universal MU models. Difference is firmware input lock and proprietary protocol validation, only accepting matched RPU radar stream. Firmware cross-flash is prohibited and will brick the unit.
- Universal Marine Displays (MU non-CR suffix, compatible with radar, ECDIS etc.)
Universal models: Dual DVI, RGB, CVBS composite video, PIP, multi-source switching. Can connect to same RPU radar (but not recommended as direct drop-in replacement for CR on original FAR28X7 radar; timing and ARPA compatibility issues may arise).
| MU-152 | 15″ | XGA 1024×768 | AC100–230V | FR-CAR1/2, FAR-1513-BB, FAR-1523-BB | Aktiver Verkauf |
| MU-152HD | 15″ | XGA 1024×768 | AC/DC | High brightness sunlight-readable, fishing vessel black-box radar | Aktiver Verkauf |
| MU-190 | 19″ | SXGA 1280×1024 | AC100–230V | FAR-1513/1523, FAR-2258, FR-CAR | EOL, large installed base |
| MU-190HD | 19″ | SXGA 1280×1024 | AC/DC | High brightness, flybridge open-air installation | Aktiver Verkauf |
| MU-192 | 19″ | SXGA 1280×1024 | AC100–230V | Successor replacing MU-190, IMO certified | Aktiver Verkauf |
| MU-192HD | 19″ | SXGA 1280×1024 | AC/DC | Ultra-high brightness 1000 cd/m² | Aktiver Verkauf |
| MU-231 | 23.1″ | UXGA 1600×1200 | AC100–230V | FAR-28X7, FAR-21X7 (universal version) | EOL |
| MU-270W | 27″ Widescreen | WUXGA 1920×1200 | AC100–230V | FAR-2xx8-NXT new-generation black-box radar, chart radar | Flagship Active Sales |
| MU-170C | 17″ | SXGA 1280×1024 | Wechselstrom | Older 17-inch universal display | EOL |
| MU-201C | 20.1″ | SXGA 1280×1024 | Wechselstrom | Older 20.1-inch universal display | EOL |
- MU-T Touch Series (New Bridge Integrated Displays, Not Direct MU-CR Replacement)
MU-170T: 17″ Berühren
MU-190T: 19″ Berühren
MU-240T: 24″ Berühren
Designed for integrated bridge systems, Ethernet MFD architecture. Not traditional DVI proprietary radar displays, cannot directly replace MU-231CR.
- Matched Radar Processor Cross Reference Table (Ersatzteil & Sourcing Reference)
RPU-013 → MU-231CR / MU-231 (FAR2807/2817/2827)
RPU-024 → MU-190CR / MU-190 (FAR1513-BB / FAR1523-BB)
RPU-011 → MU-201CR (Legacy FAR2106 series)
SPU (FAR-2xx8-NXT new generation) → MU-270W
- Spare Replacement & Selection Critical Notes
- Original factory FAR28X7 radar ships with MU-231CR as standard. Do not directly substitute with universal MU-231; radar timing and ARPA compatibility risks exist, some radar revisions will reject the display.
- CR models reject PC and standard camera DVI sources and return No Signal; universal MU accepts multiple signal sources.
- Sourcing for discontinued CR models: Used pull-outs, refurbished units, old stock. New upgrade path is full radar system upgrade to FAR2xx8-NXT + MU-270W.
- Panel cutout dimensions: MU-231 and MU-231CR share identical cutout; MU-190 and MU-190CR share identical cutout.
- Excluded Models (Not Independent MU Radar Displays)
TZT Series (TZtouch): NavNet network MFD multifunction navigation terminal, not MU display
FR Series: Integrated radar (Bildschirm + transceiver built together), not standalone MU display
FMD Series: ECDIS chart plotters, not radar display units