LANBAO PR18S-BC10DNO

PR18S-BC10DNO is an M18 cylindrical plastic housing diffuse-reflective photoelectric sensor from LANBAO (Shanghai Lanbao Sensing) PR18S Series. It adopts a dedicated control IC for stable performance and integrates multiple circuit protections. Rated IP67 for dust and water resistance, it is a general-purpose object detection component widely used in industrial automation. It comes standard with a ...

  • Produktdetails

PR18S-BC10DNO is an M18 cylindrical plastic housing diffuse-reflective photoelectric sensor from LANBAO (Shanghai Lanbao Sensing) PR18S Series. It adopts a dedicated control IC for stable performance and integrates multiple circuit protections. Rated IP67 for dust and water resistance, it is a general-purpose object detection component widely used in industrial automation. It comes standard with a 2-meter PVC cable (Suffix: -E2).

  1. Model Code Decoding

The full standard model is PR18S-BC10DNO-E2. The definition of each code is as follows:

PR18S: Produktserie, featuring M18×1 thread, PBT plastic housing and diffuse-reflective detection principle

BC10: Detection specification

BC: Diffus-reflektierend (direct reflection) detection mode

10: Rated sensing distance of 10cm (behoben, non-adjustable)

D: Power supply type, DC 10~30VDC

N: Ausgabetyp, NPN

O: Output logic, Normalerweise geöffnet (NEIN; output turns on when an object is detected)

-E2 (Default suffix): Cable outlet, standard 2m PVC cable; suffix -C stands for M12 4-pin connector type

  1. Wichtigste technische Spezifikationen
KategorieSpezifikation
Detection ModeDiffuse reflection (direct reflection)
Lichtquelle880nm Infrared LED
Rated Sensing Distance10cm (bezogen auf 90% Weiße Karte mit Reflexionsvermögen, non-adjustable)
Versorgungsspannung10 ~ 30 VDC
Ausgabetyp3-wire NPN Normally Open (NEIN)
Max Load Current≤300mA
Aktueller Verbrauch≤25mA
Ansprechzeit<8.2ms
Wiederholen Sie die Genauigkeit≤5% Sr
Hysteresis Range3% ~ 20% Sr
SchutzfunktionenVerpolungsschutz, Kurzschlussschutz, Überlastschutz, Überspannungsschutz
Status IndicatorYellow LED (lights up when object is detected)
GehäusematerialPBT Engineering Plastic
GesamtdimensionM18×1 thread × 53.5mm (body length)
SchutzklasseIP67 (Compliant with IEC Standard)
Betriebstemperatur-15℃ ~ +55℃
Umgebungsfeuchtigkeit35% ~ 95%RH (Nicht kondensierend)
ZertifizierungenCE, UL
  1. Full Model List of DC Diffuse-Reflective Sensors in the Same Series
ErfassungsabstandNPN NONPN NCPNP NOPNP NCNPN NO+NCPNP NO+NC
10cm (Non-adjustable)PR18S-BC10DNOPR18S-BC10DNCPR18S-BC10DPOPR18S-BC10DPCPR18S-BC10DNRPR18S-BC10DPR
40cm (Einstellbar)PR18S-BC40DNOPR18S-BC40DNCPR18S-BC40DPOPR18S-BC40DPCPR18S-BC40DNRPR18S-BC40DPR

Notiz: All models are equipped with -E2 (2m Kabel) standardmäßig; replace the suffix with -C for connector version.

  1. Verkabelungsdefinition (3-wire Cable Version)

Brown wire: Power positive (+10~30 VDC)

Blue wire: Power negative (0V / GND)

Black wire: Signal output (NPN NO; output conducts when object is detected, connect to the negative side of load)

  1. Typische Anwendungen

Workpiece presence detection and counting on automated production lines

Material detection for packaging and printing industries

Object recognition and sorting trigger on warehouse conveyor lines

Limit positioning and home position detection for equipment stations

Missing part and falling part detection for small components

  1. Troubleshooting Matrix for Common Faults
FehlerphänomenGrundursacheStep-by-Step Solutions
Indicator off and no output after power-on1. Reverse power polarity1. Check brown and blue wires and rewire correctly
2. Supply voltage out of 10~30VDC range2. Measure supply voltage with multimeter to ensure it is within rated range
3. Internal cable breakage3. Replace cable or conduct cross test with spare sensor
No signal output even when object is detected1. Object beyond effective sensing distance1. Reduce the distance between sensor and object with proper margin
2. Low reflectivity of measured object (pure black / light-absorbing material)2. Use high-reflective surface or select 40cm long-distance model
3. Wrong wiring of output circuit3. Verify complete connection of black output wire and load circuit
Falsche Auslösung & continuous output with no object1. Highly reflective objects in background1. Adjust mounting angle to avoid reflective background
2. Strong ambient light directly irradiating the receiver lens2. Install light shield to block strong direct light
3. Schwere elektromagnetische Störungen3. Route sensor cables away from power cables and ensure proper grounding
Fluctuating and unstable output signal1. Object stays at the detection boundary1. Fine-tune mounting distance to stay away from critical zone
2. Dust or dirt covering the lens2. Clean the lens with a soft dry cloth
  1. Alternative Modelle

Upgraded model of the same brand: PR18-BC10DNO (Nickel-copper alloy metal housing with higher mechanical strength, identical electrical parameters)

Cross-brand equivalent alternatives: OMRON E3Z-D61, Schneider XUB5BNANL2

PR18S-BC10DNO is a standard M18 plastic housing diffuse-reflective photoelectric sensor manufactured by LANBAO. See physical specifications below:

  1. Detailed Mounting Dimensions

This sensor adopts threaded cylindrical mounting. Dimensions and mounting regulations are specified as follows:

ArtikelSpezifikation
Main ThreadM18 × 1mm (Metric fine thread)
Effective Thread Length30mm
Sensor Body Length (Excluding cable/connector)Ca. 53.5mm (cable version)
Sensing Face DiameterΦ18mm
Standardzubehör2 pcs M18 lock nuts, 1 pc anti-loose washer
Recommended Mounting HoleΦ18.5mm through hole
Minimum Spacing for Side-by-Side Installation≥40mm (to prevent optical crosstalk)

Mounting Instructions

  1. Fix the sensor on cabinet panels, brackets and other mounting positions via two lock nuts; the extension length is adjustable.
  2. Align the sensing face towards the moving direction of measured objects. The tilt angle is recommended ≤15°, otherwise the effective sensing distance will be reduced.
  3. This is a non-flush mount sensor. Do not embed the sensing face into metal mounting surface; keep the sensing face fully exposed.
  4. Verkabelungsdefinition & Connection Instructions

9.1 Standard Cable Version (Suffix -E2, 2m PVC Cable, 3-wire)

DrahtfarbeFunktionBeschreibung
BraunPower Positive (V+)Connect to 10~30VDC positive terminal
BlauPower Negative (GND)Connect to power 0V / negative terminal
SchwarzSignalausgang (AUS)NPN Normally Open (NEIN) Ausgabe

9.2 Wiring Principle of NPN NO Output

This model is NPN sinking output:

When no object is detected: Output terminal is floating, internal transistor cuts off with no signal output.

When object is detected: Internal transistor turns on, black output wire connects to blue power negative terminal and outputs low level (0V).

Typische Verkabelung (Connect to PLC Sinking Input)

Brown wire → 24V+ of switching power supply

Blue wire → 0V of switching power supply & PLC common terminal (COM)

Black wire → PLC digital input terminal

Wiring for Relay / Indicator Load

One end of load connects to 24V+, the other end connects to sensor black output wire.

Sensor blue wire connects to 24V-.

Single-channel load current shall not exceed 300mA. Für induktive Lasten, connect a freewheeling diode in reverse parallel.

9.3 M12 Connector Version (Suffix -C, 4-pin Male Connector)

Pinbelegung (View from sensing face, numbered clockwise):

  1. Stift 1: Braun (Leistung +)
  2. Stift 3: Blau (Leistung -)
  3. Stift 4: Schwarz (Signalausgang)
  4. Stift 2: Ersatzteil (Unused)
  5. Montage & Vorsichtsmaßnahmen bei der Verkabelung
  6. Polarity Protection: Do not reverse power polarity. The built-in reverse polarity protection prevents burnout, but the sensor will not work normally under reversed connection.
  7. Load Limit: Maximum output load current is 300mA. Do not drive high-power loads directly; use intermediate relays for transition.
  8. Umweltanforderungen: Avoid direct sunlight or strong LED light on the sensing window, and keep away from mirror or polished metal reflective surfaces in the background.
  9. EMC Requirements: Separate sensor cables from power cables (Wechselrichter, servo cables) with a distance of ≥20cm. Do not lay them in the same conduit.