| Modellsegment | Beschreibung |
| FR | General prefix for Mitsubishi inverters (Frequency Inverter) |
| A840 | Standard model of A800 series for 400V class, high-performance vector control for general industrial use |
| 2600 | Capacity code, corresponding to Normal Duty (ND) 90kW/180A, Super Light Duty (SLD) 132kW/260A |
| 2 | CA type (current control, standard 0–20mA analog input) |
| 60 | Conformal coating on circuit boards, non-plated conductors, enhanced environmental resistance |
- Core Electrical Specifications
| Artikel | Normal Duty (ND) | Super Light Duty (SLD) | Light Duty (LD) |
| Anwendbare Motorleistung | 90kW (150HP) | 132kW (177HP) | 110kW (147HP) |
| Rated Output Current | 180A | 260A | 216A |
| Input Power | 3-phase AC 380–480V, 50/60Hz (±10% tolerance) | ||
| Ausgangsspannung | 3-phase AC 0–input voltage, proportional to input voltage | ||
| Output Frequency | 0.2–590Hz (max 400Hz in vector control mode) | ||
| Control Method | Sensorless Vector Control (RSV), V/F-Steuerung, PM Sensorless Vector Control, compatible with Induction Motors (IM) and Permanent Magnet Motors (IPM) | ||
- Hauptmerkmale
- High‑Performance Control
Universal vector control, high torque at low speed; 150% rated torque at 0.5Hz
Built-in PID controller for various closed-loop applications
Automatic energy-saving operation, adjusts output voltage according to load to reduce power consumption
- Struktur & Schutz
Protection class IP00 (open type), suitable for cabinet mounting
Circuit boards with conformal coating (konform mit IEC 60721-3-3), resistant to dust, Öl, and humidity
Umfassender Schutz: Überstrom, Überspannung, Unterspannung, Überhitzung, Erdschluss, motor overload, phase loss protection, usw.
- Built-in Interfaces & Expandability
Standard RS-485 communication (Modbus RTU protocol)
Supports various fieldbus extensions: PROFIBUS-DP, DeviceNet, EtherNet/IP, usw.
Analog inputs: 2 Kanäle (0–10V / 0–20mA, 1 channel dedicated for CA-type 0–20mA)
Digitale I/O: 5 inputs, 2 outputs (expandable)
- Überlastfähigkeit & Environmental Parameters
| Lasttyp | Überlastfähigkeit | Umgebungsbedingungen |
| Normal Duty (ND) | 150% Nennstrom für 60s, 200% rated current for 3s (inverse-time characteristic) | Operating temp: -10℃to 50℃C (derating above 40℃C) |
| Super Light Duty (SLD) | 110% Nennstrom für 60s, 120% rated current for 3s | Storage temp: -20℃ to 65℃ |
| Light Duty (LD) | 120% Nennstrom für 60s, 150% rated current for 3s | Relative humidity: 5% Zu 95% (nicht kondensierend) |
- Typische Anwendungen
General industrial machinery: Kompressoren, Pumps, Fans, Förderer, Mischer, usw.
Metal processing: Werkzeugmaschinenspindeln, winding equipment, wire drawing machines
Heben & conveying: Kräne, Aufzüge, automated storage systems
Chemisch & pharmaceutical: mixing, reaction, and conveying equipment in process industries
Building & HVAC: air conditioning systems, Pumps, fan energy-saving control
- Installation & Selection Guidelines
- Installationsanforderungen
Forced-air cooling; ensure sufficient ventilation (≥100mm clearance on all sides)
Vertikal montieren, avoid direct sunlight and corrosive gas environments
Recommended input reactor and EMC filter for improved stability and EMC performance
- Auswahlnotizen
Select load rating based on actual load type (constant torque / variable torque)
For frequent starting/stopping or heavy starting, select one frame size larger than motor power
For long cable runs, consider voltage drop and dv/dt effects; install output reactor if necessary
- Ersatzmodelle & Bestellinformationen
Direkter Ersatz: FR-A840-02600-E2-60 (European version, no built-in DC reactor)
Verbessertes Modell: FR-A840-02600-E2-60CRN (with Ethernet interface)
Official order number: 297582 (base model)
The Mitsubishi FR-A840-02600-2-60 is a high-performance, high-reliability 400V-class vector inverter, ideal for driving medium-to-high power motors and providing precise speed and torque control in various industrial automation scenarios. Its CA-type control and conformal coating ensure excellent performance in harsh industrial environments.
Mitsubishi FR Series Inverter Model List & Cross-Brand Comparison
- Classification & Model Meaning of Mitsubishi FR Series
1.1 Series Overview
| Serie | Spannungsklasse | Power Range | Core Position | Typische Anwendungen |
| FR-A800 | 200V (FR-A820) / 400V (FR-A840) | 0.4kW–500kW | Flagship high-performance vector control | Schwerindustrie, high-precision torque control, komplexe Bewegungssteuerung |
| FR-F800 | 200V (FR-F820) / 400V (FR-F840) | 0.4kW–400kW | Energy-saving for fans & Pumps | HVAC, water treatment, Gebäudeautomation |
| FR-E800/FR-E700 | 200V/400V | 0.1kW–22kW | Compact general-purpose | Verpackungsmaschinen, food & beverage, small production lines |
| FR-D800/FR-D700 | 200V/400V | 0.1kW–75kW | Easy-to-use economy type | Small fans/pumps, Förderer, general machinery |
| FR-CS80 | 200V/400V | 0.4kW–315kW | Heavy-duty special type | Cranes, winders, metallurgical equipment |
| FR-B | 200V/400V | 0.4kW–75kW | Explosion-proof special type | Hazardous areas such as chemical, petroleum, Kohlebergwerke |
1.2 Full Model Format Explanation
Standard format: FR-XXX-YYYYY-Z-W
| Field | Bedeutung | Beispiel |
| FR | General prefix for Mitsubishi inverters (Frequency Inverter) | – |
| XXX | Seriencode + Spannungsklasse | A840 (400V high-performance), F820 (200V fan/pump) |
| YYYYY | Capacity code/power identifier | 02600 (90kW/180A), 15K (15kW) |
| Z | Control type | 1 (Standard, 0–10V), 2 (CA type, 0–20mA), E2 (European version, no built-in DC reactor) |
| W | Special functions | 60 (conformal coating), CRN (Ethernet), R2R (winding dedicated) |
- Complete Model List of Mitsubishi FR Series Inverters
2.1 FR-A840 (400V High-Performance Vector Control) Core Models
| Anwendbare Motorleistung | ND Current | SLD Current | Base Model | Special Model |
| 0.75kW | 2.1A | 3.0A | FR-A840-00038-2-60 | FR-A840-00038-E2-60 |
| 1.5kW | 3.7A | 5.3A | FR-A840-00052-2-60 | – |
| 2.2kW | 5.0A | 7.2A | FR-A840-00072-2-60 | – |
| 5.5kW | 11.5A | 16.5A | FR-A840-00170-2-60 | – |
| 11kW | 23A | 33A | FR-A840-00330-2-60 | – |
| 15kW | 30A | 43A | FR-A840-00430-2-60 | – |
| 30kW | 60A | 86A | FR-A840-00860-2-60 | FR-A840-00860-E2-60 |
| 90kW | 180A | 260A | FR-A840-02600-2-60 | FR-A840-02600-E2-60 |
| 132kW | 240A | 345A | FR-A840-03450-2-60 | – |
| 280kW | 500A | 720A | FR-A840-07200-2-60 | – |
2.2 Representative Models of Other Main Series
| Serie | Representative Model | Leistung | Hauptmerkmale |
| FR-F840 | FR-F840-5.5K-2 | 5.5kW | Fan/pump dedicated, built-in PID, energy-saving control |
| FR-E740 | FR-E740-1.5K-CHT | 1.5kW | Kompakt, eingebauter EMV-Filter |
| FR-D740 | FR-D740-7.5K-CHT | 7.5kW | Simple operation, kostengünstig |
| FR-A820 | FR-A820-37K-1 | 37kW | 200V high-performance, suitable for light industry |
- Cross-Brand Inverter Comparison Table
Below shows functional and power matching between Mitsubishi FR series and major brands including Siemens, Schneider, ABB. Precise selection should consider actual load characteristics and control requirements.
| Mitsubishi Model | Siemens Equivalent | Schneider Equivalent | ABB Equivalent | Functional Match |
| FR-A840-02600-2-60 (90kW) | SINAMICS G120C 90kW | ATV630D11N4 | ACS580-01-180A-4 | Hochleistungs-Vektorregelung, suitable for heavy-duty applications |
| FR-F840-5.5K-2 (5.5kW) | SINAMICS G120X 5.5kW | ATV610U75N4 | ACS580-01-015A-4 | Fan/pump dedicated, energy-saving control |
| FR-E740-1.5K (1.5kW) | SINAMICS V20 1.5kW | ATV320U15N4 | ACS180-04-03A3-4 | Compact general-purpose |
| FR-A820-37K-1 (37kW, 200V) | SINAMICS G120 37kW 200V | ATV630D45N2 | ACS580-04-075A-2 | Medium-power vector control for 200V systems |
| FR-CS840-110K (110kW) | SINAMICS S120 110kW | ATV930D160N4 | ACS880-01-246A-3 | Heavy-duty, four-quadrant operation |
- Wichtige Auswahlpunkte & Notizen
- Load Matching Principles
Constant torque loads (Förderer, Mischer): select FR-A800 series, rated by ND current
Variable torque loads (Fans, Pumps): select FR-F800 series, rated by SLD current
Frequent start/stop or heavy starting: select one size larger than motor power
- Special Environment Adaptation
Harsh industrial environments: prefer models with “60” suffix (conformal coating: FR-A840-XXXXX-2-60)
Explosive/flammable environments: select FR-B series explosion-proof inverters
Ethernet-Kommunikation: select models with “CRN” suffix
- Installation & Wartungstipps
Vertical mounting, ≥100mm clearance on all sides for ventilation
For long cables, recommend output reactor to reduce dv/dt influence
Regular inspection of cooling fans and capacitors for long-term stable operation
Mitsubishi FR series inverters cover a full power range from 0.1kW to 500kW, meeting diverse needs from basic control to high-precision motion control via differentiated series positioning. For cross-brand selection, focus on core parameters including control method, Überlastfähigkeit, communication protocol, and environmental resistance to ensure system compatibility and stability.
Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien