Aufschlüsselung des Modellcodes
MY2N-GS DC24V
- MEIN: Miniature General-Purpose Leistungsrelais Serie
- 2: 2 Stangen (DPDT, 2NEIN + 2NC, 2 Form C contacts)
- N: Equipped with built-in LED operation indicator and mechanical status window (green LED for DC coils)
- GS: Upgraded new generation; direct drop-in replacement for discontinued MY2N-J
- DC24V: Rated coil voltage DC 24 V
Extended variants:
MY2N-D2-GS DC24V: Built-in freewheeling diode (suppresses coil back EMF, ideal for direct SPS-Antrieb)
MY2IN-GS: Equipped with locking test lever for circuit inspection; Suffix -R denotes export version with fully compatible pin layout
- Grundlegende elektrische Spezifikationen
2.1 Spulenparameter (DC24V)
Nennspannung: Gleichstrom 24 V
Stromverbrauch der Spule: 0.7 W
Coil resistance (@23℃): ≈662 Ω
Operate voltage: ≤80% of rated voltage (≤19.2 VDC)
Spannung freigeben: ≥10% of rated voltage (≥2.4 VDC)
Allowable voltage fluctuation range: 21.6~26.4 VDC
2.2 Kontaktbewertungen (Widerstandslast, Nominal 5A)
Kontaktkonfiguration: 2 sets of Form C changeover contacts (DPDT)
Kontaktmaterial: Silver (Ag)
Rated switching capacity:
✅ 5A / 250V und
✅ 5A / 30In DC
Maximum continuous carry current: 10A (static steady-state conduction; frequent switching not recommended)
Minimum applicable load: 1mA / 5VDC (suitable for low-level signal circuits)
Maximum switching capacity: 1100VA (Wechselstrom); 120W (Gleichstrom)
2.3 Lebensdauer
Mechanisches Leben: 50 Millionen Operationen (18,000 Zyklen/Stunde)
Elektrisches Leben (@5A resistive load): ≥500,000 operations (2,400 Zyklen/Stunde)
Operate time ≤15ms; Release time ≤5ms
2.4 Spannungsfestigkeit & Isolierung
Coil ↔ Contacts: 2000V und / 1 min
Contacts of different poles: 2000V und /1 min
NO and NC contacts within the same pole: 1000V und /1 min
Insulation resistance ≥1000 MΩ (measured at 500VDC)
- Pin-Definition (Standard 8-pin plug-in layout)
Compatible sockets: PYF08A-E / PYFZ-08-E
Stift 13, 14: Coil terminals (non-polarized for standard MY2N-GS; Polarity required for D2 version: Pin14=Positive, Pin13=Negative)
1st contact set: 9 (COM common), 1 (NC, normalerweise geschlossen), 5 (NEIN Normalerweise geöffnet)
2nd contact set: 12 (COM common), 4 (NC, normalerweise geschlossen), 8 (NEIN Normalerweise geöffnet)
Wiring principle: Energize coil pins 13-14 → 9-5 & 12-8 schließen; Power off → restore NC path 1-9 & 4-12
- Compatible Socket List
| Socket Model | Terminaltyp | Montagemethode | Bemerkungen |
| PYF08A-E | M3 screw terminals | DIN-Schiene / Schraubmontage | Most widely used standard domestic socket |
| PYFZ-08-E | Finger-safe screw terminals | DIN-Schiene | Preferred for control cabinet safety design |
| PYF-08-PU | Spring push-in terminals (Werkzeuglos) | DIN-Schiene | Improves wiring efficiency |
Optional accessory: PYC-A1 locking clip (prevents relay loosening under vibration)
- Ambient Operating Limits
Betriebstemperatur: -40℃ ~ +70℃ (Keine Kondensation, no icing)
Lagertemperatur: -55℃~+70℃
Humidity range: 5%~95 % relative Luftfeuchtigkeit; condensation and long-term moisture ingress prohibited
Unsuitable environments: Starker Staub, ätzendes Gas, sustained severe vibration
- Auswahlrichtlinien & Kritische Einschränkungen
- Induktive Lasten (Magnetventile, Schützspulen)
Standard MY2N-GS has no built-in surge suppression. For DC inductive loads, select MY2N-D2-GS with integrated diode. Fit external RC snubber circuits for AC inductive loads, otherwise rapid contact erosion will occur.
- Overload forbidden
5A is the rated switching current. Avoid switching loads exceeding 6A continuously. Derate for motors and lighting loads with high inrush current.
- Do not drive coil via high-frequency PWM
Continuous PWM switching causes contact chatter and burnout. Select SSR solid-state relays for high-frequency control scenarios.
- Never mix AC & DC coil models
Powering DC coil relays with AC voltage leads to overheating and permanent damage; AC coil relays fail to pull in under DC supply.
- Not applicable for safety circuits
No forced guided contacts. Use dedicated safety relays such as G9SX for emergency stop and safety interlock loops.
- Typische Anwendungsszenarien
PLC signal expansion, pneumatic solenoid valve control, small contactor driving, control cabinet logic interlock, lighting circuit switching, signal transfer on automated production lines.
- Drop-In & Upgrade Alternatives
- Direct replacement for legacy model: MY2N-J DC24V (identical pin layout and compatible sockets)
- Built-in freewheeling diode upgrade: MY2N-D2-GS DC24V
- 4-contact variant within the same series: MY4N-GS DC24V (14-pin socket PYF14A-E required)
Application Industry & Scenario Overview: OMRON MY2N-GS DC24V 5A
Core positioning: DC24V controlled intermediate relay with 2 Wechslerkontakte (DPDT). Mainly used for signal transfer after PLC outputs and low-power load switching; rated 5A/250VAC contacts, suitable for low-voltage control of high-voltage circuits.
Limitation reminder: Cannot be used as safety relay; not fit for high-frequency switching, high-inrush loads, explosive or heavily corrosive environments.
- Industrielle Automatisierung (Largest Application Field)
- Custom automation equipment
Fördersysteme, transfer modules, stop cylinder control, directional switching for small pneumatic solenoids; signal interlock for photoelectric and proximity sensors, indicator light control.
- Werkzeugmaschinen
CNC auxiliary indicator lamps, lubrication pump on/off, door limit signal transfer, cooling fan control, auxiliary loops for tool changers.
⚠ Machine tools contain many inductive loads (Magnetventile). MY2N-D2-GS (eingebaute Diode) is recommended to protect contacts and PLC modules.
- Verpackung & Druckmaschinen
Case sealers, Etikettierer, film winding mechanisms, small actuator switching, alarm buzzers and signal light circuits.
- Gummi & Plastic Injection Auxiliary Equipment
Hopper heating fans, material level alarm, signal transfer for conveyor start/stop control.
- HVAC & Gebäudeautomation
Central air-conditioning control cabinets: Air damper actuators, differential pressure alarms, auxiliary fan control, anti-freeze protection signal interlock
Fresh air systems, Abluftventilatoren, cooling tower auxiliary circuits
Zone lighting control; fire alarm signal transfer (only signal relay, NOT main fire protection circuit)
- Logistik & Lagerausrüstung
Automatisierte Lager, Sortierförderstrecken, peripheral control cabinets for AGVs
Förderer, sorting baffle cylinder control, logic expansion for photoelectric sensors
Indicator lights and alarm driver for warehouse access control
- Wasseraufbereitung & Umweltausrüstung
Dosiersysteme, auxiliary control of small water pumps, high/low level signal transfer, aeration fan auxiliary circuits, signal switching for online water quality monitoring cabinets.
Environmental note: Anti-condensation treatment is mandatory inside humid cabinets to prevent contact oxidation and poor connectivity.
- Energie, EV Charging & PV Auxiliary Cabinets
- Auxiliary fault alarm and cooling fan control for small PV combiner boxes
- Signal transfer inside AC charging station control boards, fault indicator lights and auxiliary contactor coil driving
Forbidden: Do NOT switch high-voltage DC main circuits; only permitted for low-voltage control loops.
- Lebensmittelmaschinen & Central Kitchen Equipment (Key Target Segment)
Vegetable washing equipment, Förderer, small exhaust fans, warning lights
Smart Canteen & Central Kitchen Electrical Cabinets: Alarm signal for transparent kitchen monitoring, automatic door control, auxiliary ventilation control, solenoid valve drive for cleaning machines
✅ Vorteil: DC24V is standard industrial voltage, unified with HMI, PLC and sensor power supply, supporting standardized cabinet wiring.
- Rail Support & Off-Highway Mobile Equipment
Onboard control cabinets for construction machinery, small tunnel ventilation control boxes, barrier and gate control cabinets; access control lock and traffic light drivers.
Vibration warning: Fit PYC-A1 locking clip to avoid relay disconnection.
- Labor & Testing Instruments
Aging test equipment, thermostats, small test fixtures; Magnetventile, low-power heating loads and alarm signal switching.
Compatible Load Classification
✅ Recommended Loads
- DC24V miniature solenoid valves, Anzeigelampen, buzzers
- 220VAC small fans, lighting loads, AC-Schützspulen
- Passive dry contact signal transmission
❌ Nicht empfohlen / Strictly Forbidden Loads
- High-power motors and heating elements (inrush current far exceeds 5A rating)
- Loads with switching frequency >10 cycles/minute (accelerates contact wear)
- Hazardous explosive zones (keine explosionsgeschützte Zertifizierung)
- Safety interlock and emergency stop circuits (use dedicated safety relays e.g. G9SX)
Selection Matching Advice
- Driven by PLC transistor outputs → Priority: MY2N-D2-GS (eingebaute Diode, prevents back EMF damage to PLC)
- Driven by relay-output PLC → Standard MY2N-GS directly applicable
- If driving inductive loads such as contactors and solenoids without diode version, fit external surge absorption components.
Montagemaße: OMRON MY2N-GS DC24V (5A) Official Standard Values
- Relay Body (without socket, 8-Pin-Plug-in)
Maximum overall dimension (L × W × H): 28.0 × 21.5 × 36.0 mm
Tiefe (front-back): ≤28 mm
Breite (links rechts): ≤21.5 mm
Höhe (excluding pins): ≤36 mm
Stifte: 8 cylindrical plug pins, standard 8-pin layout for MY2 series.
- Dimensions of Common DIN-mount Sockets
1) PYF08A-E (Standard widely used socket)
Gesamtdimension: 72 (D) ×22 (W) ×30 (H) mm
Montage: 35mm standard DIN rail or screw fixing
Screw mounting holes: 2 Stk, Φ4.2×5 slotted hole, center distance 44 mm
Terminal screw specification: M3
2) PYFZ-08-E (Finger-safe safety socket)
Gesamtdimension: 72 (D) ×23 (W) ×31 (H) mm
3) PYF-08-PU (Push-in spring terminal socket)
Gesamtdimension: 72 ×23 ×31 mm
Reference total height: Relay fully inserted into socket ≈64 mm (for cabinet layout reservation)
- PCB Mount Alternative (Optional PY08-02 soldering socket)
For PCB soldering installation: PY08-02 PCB socket, fully pin-compatible with MY2N-GS.
- Practical Layout Parameters for Control Cabinet Design
- Minimum side-by-side mounting clearance: Can be installed adjacently; single unit occupied width 22 mm. Total width for N units ≈ 22 × N mm
- Vertical cooling clearance recommendation: ≥8mm top & unten; ≥10mm for densely packed arrangements
- Cabinet depth reservation: ≥75mm for socket + relay assembly (avoid interference with cabinet door)
- Vibration-prone applications: Install PYC-A1 locking clip to prevent dislodging.
- Wichtige Bemerkungen
- MY2N-GS shares identical outline dimensions and fully compatible sockets with legacy MY2N-J; direct field replacement supported.
- Narrow width of only 21.5mm, ideal for space-restricted control cabinets.
- Avoid mounting adjacent to contactors and high-power power supplies; elevated ambient temperature shortens contact service life.