Schneider GV2PM10C Motor Circuit Breaker

A classic motor protection series from Schneider Electric, designed for low-power motors rated 0.1-32A. It provides protection against short circuit, overload and phase loss. Equipped with a rotary knob for manual closing and tripping, and built-in thermal-magnetic trip unit to deliver delayed overload protection and instantaneous short-circuit protection. Der Code 10 represents an adjustable setting ...

  • Produktdetails

A classic motor protection series from Schneider Electric, designed for low-power motors rated 0.1-32A. It provides protection against short circuit, overload and phase loss. Equipped with a rotary knob for manual closing and tripping, and built-in thermal-magnetic trip unit to deliver delayed overload protection and instantaneous short-circuit protection. Der Code 10 represents an adjustable setting current range of 4-6.3A, compatible with 1.5-2.2kW three-phase motors at 400V. Models suffixed with C are domestic versions, while those without C are imported versions. Both share identical performance parameters and comply with IEC and GB standards.

  1. Erklärung des Modellcodes
SegmentGV2PN10C
BedeutungProduktserie: TeSys Deca GV2 MotorschutzschalterOperation type: Panel Mount Rotary Knob with thermal-magnetic protectionSetting current range code: 4-6.3AOrigin code: Manufactured in China
  1. Wichtigste technische Spezifikationen
KategorieTechnische DatenBemerkungen
Allgemeine Informationen
Product NameTeSys Deca GV2PM Motor Circuit BreakerSpecifically designed for motor control and protection
BestellcodeGV2PM10CStandard commercial model
ProduktstatusAktivStandard product of Schneider Electric
Elektrische Parameter
Polen3P (Dreiphasig)For three-phase asynchronous motors
Aktuellen Bereich einstellen4-6.3AAdjustable via rotary knob, for 1.5-2.2kW motors (400V)
Nennbetriebsstrom (Ith)6.3AMaximaler Dauerbetriebsstrom
Bemessungsisolationsspannung (Ui)690VWithstand voltage level of insulation system
Nennbetriebsspannung (Ue)400V und (50/60Hz)Standard industrial voltage
Bewertetes ultimatives Kurzschluss-Ausschaltvermögen (Icu)100kA @ 400VKonform mit IEC 60947-2
SchutzartThermisch-magnetischDelayed overload protection + sofortiger Kurzschlussschutz
Mechanische Parameter
Abmessungen (B×H×T)89mm×85mm×91mmCompact structure to save cabinet space
GewichtCa. 280GEasy for installation and maintenance
Montage35mm DIN-SchienenmontageKonform mit EN 60715
TerminalsSchraubklemmen, for 1.5-4mm² conductorsSuitable for solid and stranded wires
BetriebsmodusDrehknopf (OFF-ON-RESET)Manual reset required after tripping
Umgebungsparameter
Betriebstemperatur-20°C ~ +60°CAdaptable to industrial environments
Schutz vor EindringenIP20Prevents finger access to live parts
ZertifizierungenCE, CCC, UL, CSAKonform mit internationalen Sicherheitsstandards
  1. Full Range of GV2PM Rotary Knob Motor Circuit Breakers
ModellAktuellen Bereich einstellenPassende Motorleistung (400V)Bemerkungen
GV2PM01C0.1-0.16A0.025-0.04kWMinimum current rating
GV2PM02C0.16-0.25A0.04-0.06kW
GV2PM03C0.25-0.4A0.06-0.1kW
GV2PM04C0.4-0.63A0.1-0.16kW
GV2PM05C0.63-1A0.16-0.25kW
GV2PM06C1-1.6A0.25-0.4kW
GV2PM07C1.6-2.5A0.4-0.63kW
GV2PM08C2.5-4A0.63-1.1kW
GV2PM10C4-6.3A1.1-2.2kWAktuelles Modell
GV2PM14C6.3-10A2.2-3kW
GV2PM16C9-14A3-4kW
GV2PM20C13-18A4-5.5kW
GV2PM21C17-23A5.5-7.5kW
GV2PM22C23-32A7.5-11kWMaximum current rating
  1. Wettbewerber & Equivalent Models
MarkeModellAktuellen Bereich einstellenBetriebsmodusErsatzbeschreibung
Schneider ElectricGV2ME10C4-6.3APush-buttonAlternative with different operation mode within the same series
Siemens3RV2011-0JA104-6.3ADrehknopfCross-brand functional replacement
ABBMS116-6.34-6.3ADrehknopfCross-brand functional replacement
EatonDIL M9-104-6.3ADrehknopfCross-brand functional replacement
ChintNDM1-63/33004-6.3ADrehknopfEconomical domestic alternative
  1. Anwendungsumgebungen & Typische Fälle

5.1 Empfohlene Anwendungen

Industrielle Automatisierung: Protection for small pumps, fans and conveyor motors; compatible with PLC control circuits

Gebäudeeinrichtungen: Control and protection for air conditioning fans, Wasserpumpen, elevator door motors and fire linkage equipment

Essen & Getränkeindustrie: Motor protection for packaging machines, filling machines and small mixers; meets hygiene requirements

Medical Equipment: Safety protection for laboratory stirrers, centrifuges and small medical pumps

Agricultural Machinery: Protection for outdoor motors such as irrigation pumps, small harvesters and feed mixers

Rechenzentren: Protection for precision air conditioner fans, cooling water pumps and UPS cooling fans

5.2 Non-recommended Applications

Häufiges Starten: Not applicable for equipment starting more than 10 times per hour. GV3 series or soft starters are recommended instead.

Heavy-Duty-Start: Not suitable for motors with starting current over 8 mal dem Nennstrom. Additional overload protection is required.

Explosive hazardous areas: No explosion-proof certification. Do not use directly in Zone IIC explosive areas.

Gleichstrommotoren: The GV2 series is designed exclusively for AC motors. Use dedicated protective devices for DC motors.

5.3 Typische Anwendungsfälle

Fall 1: Mixing System in Pharmaceutical Factory

Anwendung: Überlast, short-circuit and phase loss protection for 1.5kW reactor stirring motors

Konfiguration: GV2PM10C + LC1D12 Contactor + Control Buttons

Vorteile: Prevents motor burnout caused by agitator jamming; complies with GMP standards and trips rapidly for equipment protection during faults.

Fall 2: Air Conditioning System in Commercial Buildings

Anwendung: Protection and control for 2.2kW fresh air handling units and water pump motors

Konfiguration: GV2PM10C + Gebäudeautomationssystem (BAS) + Temperatursensoren

Vorteile: Enables automatic start/stop of fans and pumps, protects motors against overload, reduces maintenance costs and improves energy efficiency by 12%.

Fall 3: Conveyors on Automated Production Lines

Anwendung: Protection and control for 1.1kW small conveyor motors

Konfiguration: GV2PM10C + SPS + Emergency Stop Buttons

Vorteile: Avoids motor damage from conveyor jamming, works with emergency stop system for safe shutdown, and shortens Mean Time To Repair (MTTR) to within 3 Minuten.

Fall 4: Aeration System in Wastewater Treatment Plant

Anwendung: Protection and control for 2.2kW small aeration fans

Konfiguration: GV2PM10C + Liquid Level Sensors + Automatic Control Cabinet

Vorteile: Performs reliably in humid environments, prevents fan burnout from overload, realizes unattended automatic operation and cuts operational costs by 30%.

  1. Auswahltipps & Quick Reference Rules

Selection Rhythm

Choose GV2PM10C,

Aktueller Bereich 4 to 6.3A,

Matches motors 1.5 to 2.2kW,

Drehknopfbedienung, IP20 rating,

35mm DIN-Schiene, 89mm Breite,

High breaking capacity with thermal-magnetic protection,

Safeguards motors from overload and short circuit,

Reliable for industrial and building applications.

Quick Reference Rules

  1. Aktuelle Übereinstimmung: 10 = 4-6.3A; 08 = 2.5-4A; 14 = 6.3-10A. Larger figure means wider current range.
  2. Betriebsmodus: PM = Rotary knob; ME = Push-button; LP = Magnetic-only type (short-circuit protection only).
  3. Leistungsanpassung: 4-6.3A corresponds to 1.5-2.2kW @ 400V. Approximate formula: Current × 0.5 ≈ Matched motor power (kW).
  4. Installation Features: 89mm Breite, 35mm DIN-Schienenmontage, Schutzart IP20, ideal for installation inside control cabinets.
  5. Fehlerbehebung
FehlerphänomenMögliche UrsachenLösungen
Häufiges StolpernSetting current too lowTurn the rotary knob clockwise to increase current within 4-6.3A
Motorüberlastung / blockierter RotorCheck for overloading and eliminate jamming
PhasenverlustbetriebInspect three-phase power supply and repair broken wires or poor contacts
Fehler beim SchließenKnob not resetTurn the knob to OFF position then back to ON after tripping
Mechanische BlockierungClear foreign objects or replace damaged components
Falsche VerkabelungRecheck three-phase wiring and eliminate short circuits
Overheated contactsLose KabelklemmenRetighten terminals for good contact
Excessive loadReduce load or replace with higher-rated circuit breaker if needed
Zu hohe UmgebungstemperaturImprove ventilation and keep temperature below 60°C
  1. Zusammenfassung der wichtigsten Funktionen
  2. Umfassender Schutz: Thermal-magnetic trip unit provides delayed overload, instantaneous short-circuit and phase loss protection, konform mit IEC 60947-4-1.
  3. Wide Compatibility: 4-6.3A adjustable current range for 1.5-2.2kW three-phase motors; easy operation via rotary knob.
  4. Kompakte Struktur: Dimension 89mm×85mm×91mm with 35mm DIN rail mounting to save cabinet space.
  5. Hohe Zuverlässigkeit: Wide operating temperature range (-20°C ~ +60°C) and IP20 rating for harsh industrial conditions.
  6. Einfache Installation & Wartung: Standard interface for seamless matching with contactors; simple knob reset after faults.

Application Scenarios of Schneider GV2PM10C (4~6,3A)

This is a 3-pole rotary-knob motor circuit breaker with thermal-magnetic protection. It is suitable for 1.1~2.2kW three-phase asynchronous motors at 400V. Adopting DIN rail mounting, it integrates overload, short-circuit and phase loss protection, and is widely used in industrial, Gebäude, light industry and municipal fields.

  1. Hauptanwendungsszenarien

1.1 Industrial Automated Production Lines

Small belt conveyors and roller motors

Workshop auxiliary fans and dust extraction fans

Auxiliary power motors for manipulators and small positioners

Machine tool cooling pumps and lubrication pumps

Combined with PLC and relay circuits for local and remote control & Schutz

1.2 HVAC & Building Electromechanical Systems

Terminal fans, fresh air fans and exhaust fans of central air conditioning

Small circulating water pumps and make-up water pumps for building water supply & Drainage

Cooling fans for computer room precision air conditioners

Auxiliary fans and door drive motors in elevator rooms

Fire exhaust fans and damper linkage motors (meeting fire power distribution standards)

1.3 Leichtindustrie, Essen & Packaging Industry

Small mixers, blenders and feeding machines

Verpackungsmaschinen, labelers and conveyor drive motors

Filling equipment and small roller conveyors

Ventilation fans and washing pumps for food workshops

(Compact body and qualified protection level, suitable for dusty and humid workshop conditions)

1.4 Wasseraufbereitung & Municipal Engineering

Small aeration fans, dosing pumps and reflux pumps in sewage treatment plants

Booster pumps for landscape pools and residential water supply

Small power motors inside on-site control boxes of pumping stations

Fans and water pumps supporting river and pipeline monitoring equipment

1.5 Laboratory & Medical Supporting Equipment

Laboratory stirrers, centrifuges and circulating water pumps

Exhaust and fresh air system motors for medical clean rooms

Medical water purifiers and small delivery pumps

(Sensitive protection effectively prevents equipment stalling and motor burnout)

1.6 Lagerung, Logistik & Supermarkets

Warehouse ventilation fans and dust removal equipment

Condenser fans and fresh air systems for supermarket refrigeration units

Motors for light sorting lines and small roller conveyors

1.7 Agricultural Machinery & Outdoor Light-duty Equipment

Small irrigation pumps and spray devices for farmland

Feed mixers and small agricultural ventilation equipment

(Wide temperature adaptability for outdoor simple electrical control boxes)

  1. Nicht empfohlene Szenarien
  2. High-frequency starting equipment: Mehr als 10 starts per hour may cause false tripping. Dedicated starting solutions are recommended.
  3. Heavy-load motors with high starting current: Starting current far exceeds normal level; match with thermal relays and contactors additionally.
  4. Explosive hazardous areas: Without explosion-proof certification, not allowed for direct use in explosive zones.
  5. DC motors and high-power single-phase motors: Designed for three-phase AC motors only.
  6. Environments with long-term temperature above +60°C or strong corrosive gas: Protection accuracy and service life will be reduced.
  7. Common Matching Solutions for On-site Use
  8. Standard motor circuit: GV2PM10C + LC1D Contactor + Push Buttons (Local start & stoppen)
  9. Automatic control circuit: GV2PM10C + Schütz + SPS (Remote automatic control)
  10. Fire linkage circuit: GV2PM10C + Fire Module + Schütz (Fire forced start / forced trip)