Siemens 3VA9267-0HA20 Molded Case Circuit Breaker - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

 Siemens 3VA9267-0HA20 Molded Case Circuit Breaker - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

Leistungsschalter/

Siemens 3VA9267-0HA20 Molded Case Circuit Breaker

Model Code Interpretation Segment 3VA 9 267 -0HA 20 Meaning Product series: SENTRON 3VA molded case circuit breaker system Accessory category: 3VA9 series accessories Accessory type: MO320 Front-mounted Motor Operator Control voltage code: 110-230V und / 110-250V DC Applicable breaker rating: 3VA2 100/160/250A Description Flagship low-voltage power distribution series of Siemens, covering MCCBs from 16A ...

  • Produktdetails

Interpretation des Modellcodes

Segment3VA9267-0HA20
BedeutungProduktserie: SENTRON 3VA molded case circuit breaker systemAccessory category: 3VA9 series accessoriesAccessory type: MO320 Front-mounted Motor OperatorControl voltage code: 110-230V und / 110-250In DCApplicable breaker rating: 3VA2 100/160/250A
BeschreibungFlagship low-voltage power distribution series of Siemens, covering MCCBs from 16A to 1600AAccessory system specially designed for 3VA series circuit breakersMO320 motor operator, supporting remote closing and trippingWeitspannungsdesign, compatible with various power supply systemsSuitable for 3VA2 circuit breakers rated at 100A, 160A and 250A
  1. Wichtigste technische Spezifikationen
ParameterkategorieTechnische DatenBemerkungen
Allgemeine Informationen
Product NameMO320 Front-mounted Motor OperatorFor 3VA2 series molded case circuit breakers
Bestell-Nr.3VA9267-0HA20Standard commercial model
ProduktstatusAktiv (PM300)Defined by Siemens Product Lifecycle Management System
Elektrische Parameter
Steuerspannung110-230V und (50/60Hz) / 110-250In DCBreite Spannungskompatibilität
Rated Apparent Power250VAPower consumption of the operator
Betriebszeit (Schließen & Stolpern)Typical 1 zweiteMechanical response time
Mechanische Parameter
Abmessungen (B×H×T)105mm×75mm×132mmCompact design to save cabinet space
GewichtCa. 846GEasy for installation and maintenance
Terminal CapacityFor 1.5-2.5mm² conductorsSolide, stranded and fine-stranded conductors applicable
Wire Stripping Length7mmCompliant with IEC standards
Anzugsdrehmoment0.36-0.44N·mEnsure reliable connection
Umgebungsparameter
Betriebstemperatur-25°C bis +70°CSuitable for industrial environments
Lagertemperatur-40°C bis +80°CWide temperature range for storage
Schutz vor EindringenIP30Konform mit IEC 60529
  1. Full Range of MO320 Motor Operators
ModellSteuerspannungApplicable Breaker SeriesBemerkungen
3VA9267-0HA1024-60In DC3VA2 100/160/250Low voltage DC type
3VA9267-0HA20110-230V und / 110-250In DC3VA2 100/160/250Universal wide voltage type (Current Model)
3VA9157-0HA1024-60In DC3VA1 100/160For 3VA1 series
3VA9157-0HA20110-230V und / 110-250In DC3VA1 100/160For 3VA1 series
3VA9467-0HA1024-60In DC3VA2 400/630For high-current 3VA2 breakers
3VA9467-0HA20110-230V und / 110-250In DC3VA2 400/630For high-current 3VA2 breakers
3VA9257-0HA1024-60In DC3VA2 100/160Side-mounted type
3VA9257-0HA20110-230V und / 110-250In DC3VA2 100/160Side-mounted type
  1. Wettbewerber & Equivalent Model List
MarkeModellApplicable BreakerSteuerspannungErsatzbeschreibung
Siemens3VA9267-0HA103VA2 100/160/25024-60In DCLow-voltage alternative within the same series
Schneider ElectricLV432642NSX 400-630380-415V undFunctional cross-brand replacement
ABBCD2-400T1-T6 Series220V AC/DCFunctional cross-brand replacement
ABBOTM-D250Tmax-Serie24-250V AC/DCFunctional cross-brand replacement
EatonNZM-E200NZM Series24-230V AC/DCFunctional cross-brand replacement
  1. Anwendungsumgebungen & Branchenfälle

5.1 Empfohlene Anwendungsszenarien

Industrielle Automatisierungssysteme: Remote closing and tripping of motor circuits for production line automatic control

Rechenzentren: Remote operation of breakers for UPS systems to improve power supply reliability

Gewerbebauten: Remote control of breakers for emergency lighting and fire protection systems, complying with safety regulations

Energy Infrastructure: Remote monitoring of breakers for photovoltaic inverters and energy storage systems to boost operation efficiency

Water Treatment Facilities: Automatic switching of pump circuits to realize unattended operation

5.2 Nicht empfohlene Szenarien

Explosive Hazardous Areas: Additional explosion-proof certification is required; not suitable for direct use in IIC explosive zones

High Electromagnetic Interference Environments: Extra electromagnetic shielding is needed; not recommended near unshielded high-frequency equipment

Severe Vibration Environments: Not applicable where vibration acceleration exceeds 5g, which may impair mechanical reliability

5.3 Typische Anwendungsfälle

Fall 1: Automobile Manufacturing Plant

Anwendung: Remote control of power circuits for welding robots

Konfiguration: 3VA2 250A MCCB + 3VA9267-0HA20 Motor Operator + PLC Control System

Vorteile: Realize automatic power-off protection for production lines, reduce manual operation and increase productivity by 15%

Fall 2: Large-scale Data Center

Anwendung: Remote management of Power Distribution Units (PDU) in server cabinets

Konfiguration: 3VA2 160A MCCB + 3VA9267-0HA20 + Building Management System (BMS)

Vorteile: Remote monitoring and circuit switching, quick fault isolation; Mean Time To Repair (MTTR) reduced to less than 5 Minuten

Fall 3: Hospital Operating Room

Anwendung: Emergency control of dedicated power circuits for medical equipment

Konfiguration: 3VA2 100A MCCB + 3VA9267-0HA20 + Emergency Control System

Vorteile: Fast power switching for operating rooms, ensure safe operation of medical devices; konform mit IEC 60601 medical standards

  1. Auswahltipps & Quick Reference Rules

Selection Rhythm (For Reference)

Model 3VA9267-0HA20,

Abdeckungen 110 to 230V AC/DC,

Matches 3VA2 100/160/250A breakers,

Front-mounted MO320 design,

One second for remote switch action,

Rated power at 250VA,

Dimension 105×75×132mm,

Ideal for industrial and building applications.

Quick Reference Rules

  1. Spannungsanpassung: HA20 = Wide voltage (110-230V und / 110-250In DC); HA10 = Low voltage (24-60In DC)
  2. Anwendbare Serie: 9267 = 3VA2 100/160/250A; 9157 = 3VA1 100/160A; 9467 = 3VA2 400/630A
  3. Montageart: 9267 = Front-mounted; 9257 = Side-mounted
  4. Kernparameter: 1-second operating time, 250VA power rating, compatible with 1.5-2.5mm² conductors
  5. Fehlerbehebung & Lösungen
FehlerphänomenMögliche UrsachenLösungen
Failure to close or tripAbnormale SteuerspannungVerify the voltage is within 110-230V AC / 110-250In DC
Lose KabelklemmenRetighten terminals with torque of 0.36-0.44N·m
Mechanische BlockierungCheck connection between operator and breaker, Fremdkörper entfernen
Slow closing/trippingInsufficient power supply capacityEnsure control circuit power ≥ 250VA
Excessively low ambient temperatureApply heating measures when temperature is below -25°C
Excessive operating noiseMechanical wearInspect transmission parts and replace grease if necessary
Unstable installationRe-fix the operator and ensure flat mounting surface
  1. Zusammenfassung der wichtigsten Funktionen
  2. Wide Voltage Compatibility: 110-230V und / 110-250In DC, reducing spare parts stock and procurement costs
  3. Schnelle Reaktion: Typical 1-second operating time, meeting emergency control requirements
  4. Kompakte Struktur: Dimension 105×75×132mm, saving space inside switchgear cabinets
  5. Hohe Zuverlässigkeit: Operating temperature range from -25°C to +70°C, adaptable to harsh industrial conditions
  6. Einfache Installation & Wartung: Standard interface for perfect matching with 3VA2 series breakers

Typical Application Cases of Siemens 3VA9267-0HA20 (MO320 Motor Operator)

This accessory is designed for 3VA2 100/160/250A molded case circuit breakers to realize remote motorized closing and tripping. With control voltage of 110–230V AC / 110–250V DC, it is widely applied in industrial, Rechenzentrum, building and energy sectors.

  1. Automobile Welding Workshop (Industrielle Automatisierung)

Konfiguration: 3VA2 250A + 3VA9267-0HA20 + SPS / Fieldbus System

Anwendung: Remote switching and automatic fault isolation for power circuits of welding robots and welders

Vorteile: Minimize manual work, improve workshop safety; cut downtime via remote power-off during faults

  1. Large-scale Data Center (Infrastruktur)

Konfiguration: 3VA2 160A + 3VA9267-0HA20 + BMS / EMS

Anwendung: Centralized remote control for cabinet PDUs, UPS outputs and precision air conditioners

Vorteile: Remote inspection and circuit operation, rapid fault location and isolation; wide voltage design compatible with global mains power

  1. Commercial Complex & Hochhäuser (Smart Power Distribution)

Konfiguration: 3VA2 100–250A + 3VA9267-0HA20 + Fire Alarm / BAS System

Anwendung: Interlocked control for emergency lighting, fire pumps and exhaust fans; remote power cut for energy saving during off-hours

Vorteile: Comply with mandatory fire power cut regulations; lower operation costs and improve energy efficiency

  1. Photovoltaik & Energy Storage Power Stations (Neue Energie)

Konfiguration: 3VA2 250A + 3VA9267-0HA20 + Power Station Monitoring System

Anwendung: Remote grid connection/disconnection and fault protection for AC sides of inverters and energy storage cabinets

Vorteile: Adapt to wide outdoor temperature (-25°C bis +70°C); realize remote operation and reduce on-site inspection work

  1. Hospital Operating Room & Intensivstation (Medical Power Supply)

Konfiguration: 3VA2 100A + 3VA9267-0HA20 + Medical Isolated Power System

Anwendung: Emergency switching and protection for surgical equipment and life support systems

Vorteile: Fast switching (ca. 1 zweite), high operational reliability and compliance with medical power supply standards

  1. Wasseraufbereitung & Pumping Stations (Municipal Engineering)

Konfiguration: 3VA2 160–250A + 3VA9267-0HA20 + Pump Station PLC

Anwendung: Remote start/stop and overload protection for submersible pumps, blowers and chemical dosing equipment

Vorteile: Suitable for humid and dusty environments; unattended remote control to reduce operation costs

Kern-Matching-Punkte

Applicable Breakers: 3VA2 100/160/250A (3-Pole / 4-Pole)

Steuerspannung: 110–230V AC / 110–250V DC (Universal wide voltage)

Montageart: Front-mounted (MO320), Dimension: 105×75×132mm

Key Functions: Remote closing & Stolpern, fault isolation; geeignet für Industrie, building and new energy applications

Vorher:

Nächste:

Hinterlasse eine Antwort

Eine Nachricht hinterlassen