GVAE11 is a 1NO + 1NC instantaneous Hilfskontaktblock of Schneider TeSys GV series. It is front-mounted and compatible with GV2/GV3 series motor circuit breakers. With a rated current of 2.5A and IP20 protection degree, it is used for status monitoring and signal feedback of motor control circuits, serving as a standard accessory for motor control in industrial automation systems.
| Codesegment | Bedeutung | Beschreibung |
| GVA | Produktkategorie | Auxiliary contact block for GV series |
| E | Montageposition | Front mounting, different from side-mounted models |
| 11 | Kontaktkonfiguration | 1 Normalerweise geöffnet (NEIN) + 1 Normalerweise geschlossen (NC) instantaneous contacts with mechanical linkage |
Vollständige Modelldefinition: GVAE11 = Schneider GV series, front-mounted, 1NO+1NC instantaneous auxiliary contact block
- Grundlegende technische Spezifikationen
| Kategorie | Spezifikationen | Bemerkungen |
| General Characteristics | ||
| Produkttyp | Instantaneous auxiliary contact block | Mechanically linked, operates synchronously with main contacts of circuit breaker |
| Kontaktkonfiguration | 1NEIN + 1NC (Sofort) | NO/NC status switches in sync with the main circuit of the circuit breaker |
| Compatible Devices | Schneider TeSys GV2/GV3 series motor circuit breakers | Compatible with GV2L, GV2LE, GV2ME, GV2P, GV2RT, GV3L, GV3P and other models |
| Montagemethode | Front snap-on installation | Tool-free assembly & quick removal with precise positioning |
| Elektrische Parameter | ||
| Nennbetriebsspannung | 24–240 V Wechselstrom, 24–60V DC | Suitable for standard voltages of control circuits |
| Nennbetriebsstrom | 2.5A (Ith) | Continuous current carrying capacity |
| Bemessungsisolationsspannung | 690V und | Complies with insulation requirements for industrial control circuits |
| Mechanische Ausdauer | 100,000 Betriebszyklen | High reliability for frequent operations |
| Elektrische Ausdauer | 100,000 Betriebszyklen (AC-15 2.5A/240V) | Meets long-term service requirements of control circuits |
| Terminaltyp | Schraubklemmen | Copper wire cross-section: 0.5–1.5mm²; Anzugsdrehmoment: 0.8–1.2Nm |
| Körperlich & Umgebungsparameter | ||
| Schutzgrad | IP20 | Verhindert den Zugriff von Fingern auf spannungsführende Teile |
| Abmessungen (B × H × T) | 45 × 20 × 15mm | Kompakte Struktur, no extra installation space required for circuit breakers |
| Betriebstemperatur | -25℃ ~ +60℃ | Großer Temperaturbereich für Industrieumgebungen |
| Farbe | Grau | Matches the appearance of GV series circuit breakers |
| Zertifizierungen | CCC, UL, CSA, EAC | Multi-standard certifications for global application |
| Bestellinformationen | ||
| Manufacturer Part No. | GVAE11 | Official Schneider model |
| Standard-Bestellcode | GVAE11 | Original imported version |
| EAN-Code | 3.38911E+12 | International universal commodity code |
- Vollständige Modellliste (GVAE Series Auxiliary Contacts)
| Modell | Kontaktkonfiguration | Montageposition | Compatible Devices | Hauptanwendung |
| GVAE1 | 1NO or 1NC (Optional) | Front | GV2/GV3 Series | Simple status indication, single signal output |
| GVAE11 | 1NEIN + 1NC | Front | GV2/GV3 Series | Standard status monitoring, output open/close signals simultaneously |
| GVAE20 | 2NEIN | Front | GV2/GV3 Series | Control circuits requiring multiple NO signals |
| GVAE02 | 2NC | Front | GV2/GV3 Series | Control circuits requiring multiple NC signals |
| GVAE14 | 1NEIN + 1NC | Side | GV2/GV3 Series | Side mounting for space-limited installations |
| GVAE24 | 2NEIN | Side | GV2/GV3 Series | Side mounting for multiple NO signal demands |
| GVAE04 | 2NC | Side | GV2/GV3 Series | Side mounting for multiple NC signal demands |
- Ersatzmodelle & Konkurrenzvergleich
4.1 Internal Schneider Replacements
| Originalmodell | Ersatzmodell | Unterschiede | Anwendungsszenarien |
| GVAE11 | GVAE14 | Different mounting position (side mounting) | Insufficient front space, side mounting required |
| GVAE11 | GV2ME + Integrierte Kontakte | Integriertes Design, no extra assembly needed | New equipment selection for integrated layout |
| GVAE11 | GV3P + Integrierte Kontakte | Upgraded series with enhanced functions | High-standard applications requiring advanced protection |
4.2 Markenübergreifender Wettbewerbervergleich
| Marke | Modell | Kontaktkonfiguration | Compatible Devices | Hauptunterschiede |
| Schneider | GVAE11 | 1NEIN + 1NC | GV2/GV3 Series | Precise mechanical linkage, Schutzart IP20, high compatibility |
| ABB | MS132-01 | 1NEIN + 1NC | MS132 Series | Side mounting, rated current 3A, ähnlicher Preis |
| Siemens | 3RV2091-1A | 1NEIN + 1NC | 3RV20 Series | Steckmontage, rated current 2A, complete certifications |
| Eaton | PKZM0-AUX11 | 1NEIN + 1NC | PKZM0 Series | Front mounting, rated current 2.5A, spring terminals |
| Chint | NXC-A11 | 1NEIN + 1NC | NXC-Serie | Kostengünstig, reliable domestic alternative |
- Anwendungsumgebungen & Typische Fälle
5.1 Empfohlene Anwendungen
Motor Control Circuit: Feedback circuit breaker ON/OFF status for PLC/DCS system monitoring
Alarm System: Trigger audible and visual alarms via NC contacts when the circuit breaker trips
Interlock Control: Prevent simultaneous startup of multiple motors and realize sequence control
Fernüberwachung: Transmit status signals to SCADA system for remote diagnosis
Safety Circuit: Form safety protection circuits together with emergency stop buttons
5.2 Nicht empfohlene Anwendungen
Main Circuit Usage: Rated current is only 2.5A, not applicable for motor main circuits
High-frequency Switching: Über 1000 switching cycles per hour will shorten service life
Severe Electromagnetic Interference Environment: Additional shielding is required to avoid malfunction
Humid/Corrosive Environment: IP20 protection is insufficient; install extra enclosure or select higher protection grade products
5.3 Typische Anwendungsfälle
Fall 1: Pump Unit Control in Wastewater Treatment Plant
Ausrüstung: 15kW submersible pump, GV2P32 circuit breaker + GVAE11 auxiliary contact
Konfiguration: NO contact of GVAE11 connected to PLC digital input module; NC contact connected to alarm circuit
Ergebnis: Real-time monitoring of pump operating status, automatic alarm and event recording upon faults
Fall 2: Conveyor System in Automotive Production Line
Ausrüstung: 12 conveyor lines, each equipped with GV2P32 + GVAE11
Konfiguration: GVAE11 contacts linked with PLC to realize sequential startup and interlock protection for conveyors
Merkmale: Mechanical linkage ensures accurate status feedback and reduces misjudgment of control systems
- Fehlerbehebung & Maintenance Manual
6.1 Häufige Fehler & Lösungen
| Fehlerphänomen | Mögliche Ursachen | Lösungen |
| No change of contact signals | 1. Improper installation of contact block | 1. Reinstall the block and ensure the clip is fully engaged |
| 2. Damaged mechanical linkage | 2. Inspect linkage mechanism and replace damaged unit | |
| 3. Burned or oxidized contacts | 3. Clean or replace the contact block | |
| 4. Falsche Verkabelung | 4. Check wiring and confirm correct connection of NO/NC contacts | |
| Kontaktschweißen | 1. Excessive current in control circuit | 1. Ensure control circuit current ≤ 2.5A |
| 2. Overheating caused by frequent switching | 2. Reduce switching frequency or select higher-rated contacts | |
| 3. Arc erosion | 3. Replace with a new contact block | |
| Signal interference | 1. Control wires not separated from main wires | 1. Separate control wires from main wires (spacing ≥ 100mm) |
| 2. No shielded cable used | 2. Use shielded cable with single-end grounding | |
| 3. Schlechte Erdung | 3. Inspect and ensure reliable grounding | |
| Loose installation | 1. Clip not fully locked | 1. Reinstall until a click sound is heard |
| 2. Loosening caused by vibration | 2. Fit shock-absorbing pads or reinforce installation |
6.2 Maintenance Procedures
- Tägliche Inspektion (Wöchentlich)
Check installation condition and ensure no looseness
Inspect terminals for overheating and looseness
Test contact switching to confirm synchronization with circuit breaker
- Routinewartung (Jeder 6 Monate)
Power off and remove dust on the contact block
Kontaktwiderstand messen (shall be ≤ 50mΩ)
Check flexibility of mechanical linkage
- Jährliche Wartung
Replace frequently used contact blocks
Test insulation performance of control circuits
Retighten all electrical connections
6.3 Quick Diagnosis Tips
No signal? Check installation and linkage first.
Contact welded? Limit current and cut switching times.
Signal interference? Separate wires, apply shielding and good grounding.
Loose fitting? Re-clip firmly and add shockproof measures for vibrating sites.
- Auswahl & Installationsrichtlinien
7.1 Auswahlregeln
Kompatibilität: Confirm matching with GV2/GV3 series circuit breakers; not applicable for other series
Kontaktkonfiguration: Select 1NO+1NC (GVAE11), 2NEIN (GVAE20) or 2NC (GVAE02) according to control demands
Montageposition: Choose GVAE11 for front mounting, GVAE14 for side mounting
Aktuelle Übereinstimmung: Control circuit current shall not exceed 2.5A; select higher-specification products if overloaded
7.2 Installationshinweise
Installation Sequence: Install circuit breaker first, then attach the contact block and fully lock the clip
Verkabelungsstandard: Use 0.5–1.5mm² copper wires with tightening torque of 0.8–1.2Nm; avoid over-tightening
Clear Marking: Label NO/NC contacts to prevent wiring errors
Linkage Test: Manually operate the circuit breaker after installation to verify synchronous contact action
Protection Measures: Install extra enclosures for dusty or humid environments
- Production Status & Ersatzlösungen
Current Status of GVAE11: In production, no discontinuation plan (as of June 2026)
Upgrade & Ersatzoptionen:
- Funktionserweiterung: GV3 series models with built-in contacts (no extra assembly, fewer fault points)
- Intelligent Upgrade: TeSys T series (with communication function for network-based status transmission)
- Inländische Alternative: Compatible domestic GVAE11 models (lower cost with equivalent performance)