Siemens 3RT2026-1AP00 AC Contactor - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

Siemens 3RT2026-1AP00 AC Contactor - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

Schütz/

Siemens 3RT2026-1AP00 AC Contactor

Model Code Breakdown Code Segment Code Definition 3RT2 3RT2 New-generation AC contactor of Siemens SIRIUS series, replacement for legacy 3RT1 series 26 26 Size S0, rated AC-3 current: 25A, compatible with 11kW motor at 400V 1 1 Spulentyp: AC-operated coil AP AP Coil voltage: 230V und, 50Hz standard mains supply 0 0 Standardkonfiguration: ...

  • Produktdetails

Aufschlüsselung des Modellcodes

CodesegmentCodeDefinition
3RT23RT2Neue Generation AC-Schütz von Siemens SIRIUS series, replacement for legacy 3RT1 series
2626Size S0, rated AC-3 current: 25A, compatible with 11kW motor at 400V
11Spulentyp: AC-operated coil
APAPSpulenspannung: 230V und, 50Hz standard mains supply
00Standardkonfiguration: Schraubklemmen, 1Hilfskontakte NO+1NC, no special options
  1. Grundlegende technische Spezifikationen
KategorieParameterBemerkung
Grundlegende Spezifikationen
Produkttyp3-pole AC power contactorSIRIUS range, Schutzart IP20
NennbetriebsstromAC-3: 25A @400V; AC-1:40A @400VAC-4:15.5A @400V
Nennleistung11kW under AC-3 at 400VFor standard 3-phase asynchronous motors
Polkonfiguration3 main poles + 1Hilfskontakte NO+1NCEingebaute Hilfskontakte, no extra accessory required
Coil Data
Spulenspannung230V und, 50HzGlobal standard industrial mains voltage
SpulenstromverbrauchAbholen:105VA; Sealed holding:12VALow-power design for energy saving
Mechanisch & Environmental Data
Gesamtdimension(L×B×H)85mm×45mm×86mmCompact footprint for cabinet space saving
MontageStandard-DIN-SchienenmontageKonform mit EN 50022
Ambient Operating Temp.-25°C ~ +60°CWide temperature tolerance for harsh industrial environments
BeendigungSchraubklemmenSecure connection suitable for repeated wiring
Elektrische Ausdauer1,000,000 Operationen(AC-3); 10,000,000 Operationen(AC-1)Long service life to cut maintenance cost
ZulassungenCE, UL, CSAGlobally accepted international safety certifications

III. Full 3RT2026 Series Model List (S0 frame, 25A bewertet)

Sorted by coil voltage:

Teile-Nr.SpulenspannungHilfskontakteBeendigungBesonderheit
3RT2026-1AP00230V und1NO+1NCSchraubenStandardversion
3RT2026-1AP60230V und1NO+1NCSpring-cageSchnelle Verkabelung
3RT2026-1AQ00110V und1NO+1NCSchraubenStandardversion
3RT2026-1AQ60110V und1NO+1NCSpring-cageSchnelle Verkabelung
3RT2026-1BB4024In DC1NO+1NCSchraubenStandardversion
3RT2026-1BB6024In DC1NO+1NCSpring-cageSchnelle Verkabelung
3RT2026-1BG4048In DC1NO+1NCSchraubenStandardversion
3RT2026-1BH40110In DC1NO+1NCSchraubenStandardversion
3RT2026-1BJ40220In DC1NO+1NCSchraubenStandardversion
3RT2026-1AP00-1AA0230V und1NO+1NCSchraubenVertikale Montage
  1. Querverweis & Ersatzliste
  2. Siemens Internal Obsolete Replacement
Obsolete PartReplacement PartErsatzgrundKompatibilität
3RT1026-1AP003RT2026-1AP003RT1 discontinued; 3RT2 upgraded generationFull interchangeability, identical mounting dimension
3RT1026-1AP00-1AA03RT2026-1AP00-1AA0Same-series product upgradeFull interchangeability
3TF4322-0AP03RT2026-1AP00Outdated 3TF series, superior performance of 3RT2Minor cabinet modification needed for mounting
  1. Cross-Brand Equivalent Options
MarkeModellMatching ScoreUnterschiede
ABBA16-30-01★★★★☆Rated 16A < 25A, derated operation required
Schneider ElectricLC1D25M7C★★★★★Full equivalent:25A,230V und,1NO+1NC
Allen-Bradley100-C25D*00★★★★☆Slightly larger dimension, identische Funktionen
EatonDILM25-10★★★★☆Only 1NO auxiliary contact; extra NC contact needed separately
  1. Anwendungsumgebung & Branchenfälle
  2. Recommended Application Fields

Factory Automation: 3-phase asynchronous motor control ≤11kW@400V for pumps, Fans & Förderanlagen

Gebäudeelektrik & HVAC: Air-conditioning units, ventilation blowers, fire fighting pumps

Wasseraufbereitung & Wastewater: Abwasserpumpen, chemical dosing systems, filter equipment

Essen & Getränk: Production line motors, mixing machinery, Verpackungsmaschinen

OEM Machinery: Werkzeugmaschinen, Drucken & packaging equipment OEM matching

  1. Not Recommended Application Conditions

Heavy shock & vibration sites (shipboard, Bergbaumaschinen): Anti-vibration base required if mandatory use

Umgebungen mit korrosiven Gasen (electroplating, chemical plant): Sealed anti-corrosion contactor required

Ultra-frequent cycling loads (welding machine, rapid start-stop equipment): Select dedicated AC-4 rated contactor

High DC loads (Gleichstrommotoren, electrolysis equipment): Use dedicated DC-coil DC contactors

  1. Typische Anwendungsbeispiele

Fall 1: Blower Control for Small Sewage Treatment Plant

Ausrüstung: 3 sets of 5.5kW aeration blowers, 3-phase 400V

Control configuration: 3RT2026-1AP00 + 3RU2016-1CB00 thermal overload relay + Siemens-SPS

Vorteile: Kompakte Größe, integrated auxiliary contacts, simplified cabinet layout & geringer Stromverbrauch

Fall 2: Food Packaging Conveyor Line

Ausrüstung: Multiple 3kW conveyor motors with 230V AC control circuit

Control configuration:3RT2026-1AP00 + 3RH2111-1AP00 auxiliary contact block

Vorteile: Fast installation, high reliability for humid food workshop environment

  1. Auswahlrichtlinien & Quick Coding Rules

Quick Selection Mnemonic

3RT2026 defined by 25A rated current

AP stands for 230V AC coil voltage

Standard 1NO+1NC with screw terminal wiring

Direct upgrade substitute for old 3RT1026

Perfect match for 11kW motor at 400V supply

Quick Coding Rules

  1. Model breakdown:3RT2(Serie)+026(25A)+1(AC coil)+AP(230V)+00(Standard build)
  2. Aktuelle Übereinstimmung:25A AC-3 =11kW@400V;40A AC-1 for resistive heating loads
  3. Replacement rule:Direct drop-in swap from 3RT1026-1AP00 without mounting hole modification
  4. Terminal option:00=Screw terminal;60=Spring-cage terminal per site requirement

VII. Leitfaden zur Fehlerbehebung

FehlersymptomGrundursacheRemedy
Schütz zieht nicht anNo/low coil supply voltageCheck control circuit & measure coil input voltage
Excessive operating humDust/oil contamination on core pole faceClean core surface, inspect short-circuit ring
Severe contact erosionOverload or frequent switchingUpgrade to higher rating contactor & optimize control logic
Overheated coilOvervoltage or high ambient temperatureStabilize input voltage & improve cabinet ventilation
Poor auxiliary contact conductionContact oxidation or mechanical wearKontakte reinigen; replace contactor if heavily worn

VIII. Compliance bei Lufttransporten & Zertifizierungen

Shipping Classification: Ungefährliche Güter, keine eingebaute Lithiumbatterie, compliant with IATA DGR

CE Approval: Complies with EN 60947-4-1, Cert No.:CE 0123

UL Approval: Complies with UL 508, File No.:E249461

RoHS Compliance: Conforms to Directive 2011/65/EU, restricted hazardous substance free

  1. Bestellinformationen

Bestellcode:3RT2026-1AP00

Minimum Pack Quantity:1 unit per carton

Garantiezeitraum:12 Monate

Recommended Spare Parts:3RU2016-1CB00(thermisches Überlastrelais),3RH2111-1AP00(auxiliary contact block)

Application Scope of Siemens 3RT2026-1AP00 (AC-3 25A@400V, 11kW, 230V AC Coil, 1NO+1NC Aux. Kontakte)

Rated Application: 3-phase motor ≤11kW@400V; Resistive load max.40A(AC-1), DIN rail mount, 230VAC control circuit as standard.

  1. Priority Application Industries & Segments

1.1 HVAC & Klimaanlage (Largest consumption volume)

  1. Cabinet air-conditioner & condenser fans:2.2~7.5kW centrifugal blowers
  2. Fresh air handlers, smoke exhaust & fire supplementary fans:3~11kW 3-phase fans
  3. Cooling tower & chilled water circulation pumps (4kW/5.5kW/7.5kW)

Matching: Paired with 3RU2016 thermal relay for motor overload protection, cabinet built-in installation.

1.2 Wasserversorgung & Abwasserbehandlung

  1. Abwasserhebepumpen, self-priming pumps & chemical dosing agitator pumps (1.5~11 kW)
  2. Raw water booster pumps & filter backwash pumps for water purification plants
  3. Residential secondary water supply booster pumps, duty-standby start-stop control(single pump ≤11kW)

1.3 Food Packaging & Light Industry Automation

  1. Packaging machine belt & film winding motors (0.75~5,5 kW)
  2. Dough mixers & filling agitator motors
  3. Roller drive motors for filling production line & conveyor start-stop control

1.4 Holzbearbeitung & Small Machine Tools

  1. Sanders, bench saws & drill spindle motors (3~7,5 kW)
  2. Air compressor host control for 7.5kW/11kW screw & piston compressors

1.5 Logistik & Warehouse Conveying Equipment

  1. Belt & roller conveyor drive motors (1.5~7,5 kW)
  2. Small lifting equipment drive motors (motor load ≤11kW)
  3. Power control for mini shuttle machines in automated warehouses

1.6 Gebäude & Civil Electrical Works

  1. Basement drainage pumps, civil defense ventilation fans, fire damper linked blowers
  2. Temporary site concrete mixers & construction dust extraction fans

1.7 Cold Chain Refrigeration

Start-stop control for cold room evaporator fans & chiller circulation pumps (3~7,5 kW)

  1. Resistive Load Applications (AC-1:40A Max.)

Direct usage for heating tubes, drying oven heating circuits, incandescent lamp banks & cabinet space heaters; total single/3-phase resistive load ≤40A.

  1. Non-Recommended Operating Conditions
  2. High-frequency jogging (>60 cycles/min): Welders & frequent forward/reverse machines lead to rapid contact burnout; adopt dedicated AC-4 contactor instead
  3. Motors over 11kW@400V: Upgrade to higher rating 3RT2035/3RT2045 series
  4. Severe corrosive atmosphere (electroplating, strong acid chemical workshop): Sealed anti-corrosion type required
  5. Heavy vibration environment(Bergbau, vehicle-mounted construction machinery): Anti-vibration base or vehicle-specific contactor needed to avoid accidental coil dropout
  6. High-power DC loads (DC motor & battery circuit): Specially designed DC-coil DC contactor required
  7. Standard Matching Control Schemes
  8. Basic motor control circuit: 3RT2026-1AP00 + 3RU2016 thermal relay + 230VAC pushbutton start-stop
  9. Star-Delta starter: Same model contactor for main & star-point connections (star-delta startup for motor ≤11kW)

Vorher:

Hinterlassen Sie eine Antwort

Eine Nachricht hinterlassen